Boeing DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20090724TUL22Longeron · crackedTUL - LONGERON 2L IS CRACKED AT FRAME STATION 160 ATTACH POINT. REPLACED LONGERON AT L2L UNDER SRM 53-02-00.SDR AALA20090724TUL18Attach Angle · corrodedTUL - CORROSION ON INTERCOSTAL LOWER ATTACH ANGLE STATION 1212-1220 BETWEEN L30 AND L29R. REPLACED LOWER ATTACH ANGLE UNDER SRM 51-00-00-12.SDR AALA20090724TUL13Casting · crackedTUL - RIGHT OUTBOARD FLIGHT SPOILER PANEL CENTER HINGE CASTING IS CRACKED AT INBOARD RADIUS. REPLACED FLIGHT SPOILER.SDR AALA20090724TUL11Cusp Web · corrodedTUL - CORROSION ON CUSP RIGHT STATION 988-991. CUT OUT DAMAGE AND INSTALLED DOUBLER PER AARD 53-20-00-16.SDR AALA20090723TUL41Pan · crackedCRACK IN WINDOW PAN AT STATION 1022L. INSTALLED DOUBLER PER AARD 53-10-00-25.SDR AALA20090723TUL40Pan · crackedWINDOW PAN CRACKED AT STATION 1041. INSTALLED DOUBLER PER AARD 53-10-00-25.SDR AALA20090723TUL39Pan · crackedWINDOW PAN CRACKED AT STATION1060L. INSTALLED DOUBLER AS PER AARD 53-10-00-75.SDR AALA20090723TUL33Skin · dentedDENT IN FUSELAGE AT STATION 218 AND JUST ABOVE LONGERON 19L. DENT COLD WORKED AND DYE CHECKED. INSTALLED DOUBLER PER AARD 53-30-00-9.SDR AALA20090723TUL32Angle · crackedLEFT STUB WING TO FUSE TOP ANGLE AFT END CRACKED STATION 1446. STOP DRILLED CRACKS AND INSTALLED DOUBLER PER AARD 54-20-00-1.SDR AALA20090723TUL31Skin · damagedHOLE DRILLED THROUGH FUSELAGE SKIN ABOVE LEFT PYLON ON STUB WING ABOVE UPPER ATTACH ANGLE STATION 1464. INSTALLED REPAIR DOUBLER PER AARD 53-30-00-02.SDR AALA20090723TUL30Skin · damagedDAMAGE TO FUSELAGE SKIN RIGHT SIDE BETWEEN L22R AND L23R STATION 218. INSTALLED DOUBLER PER AARD 53-30-00-9.SDR AALA20090723TUL29Strap · corrodedSTRAP CORRODED IN AFT CARGO AT L28R STATION 1212. REMOVED CORROSION AND INSTALLED DOUBLER PER EA MD 80-53-006855.SDR AALA20090723LGA04Strap · brokenFORWARD LOWER FLASHLIGHT STRAP BROKEN. REPLACED STRAP.SDR AALA20090723LGA03Battery Pack · dischargedCEILING EMERGENCY LIGHTS AT 17DEF INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY CEILING LIGHTS AT SEAT 17. OPS CHECK NORMAL.SDR AALA20090723LGA02Battery · not seatedCEILING EMERGENCY LIGHTS AT 11DEF-10DEF INOPERATIVE. RESEATED BATTERIES AT BIN 9DEF. OPS CHECK GOOD.SDR AALA20090723LGA01Battery Pack · dischargedAFT STAIRWAY EMERGENCY LIGHTS INOP. RESEATED BATTERY PACK IN AFT LAVATORY CEILING. EMERGENCY LIGHTS OPS CHECK NORMAL.SDR AALA20090722TUL02Beam · bentNUMBER 8 BEAM ON FORWARD ENTRY DOOR BENT. REPLACED NUMBER 8 BEAM ON FORWARD ENTRY DOOR IN ACCORDANCE WITH ESO 80172.SDR AALA20090804TUL04Skin · corrodedCORROSION FOUND UNDER MID CARGO DRAIN AT STATION 655 BETWEEN L29R-L30. CUT OUT BLENDED AREA AND DYE CHECKED, NO CRACKS FOUND. INSTALLED DOUBLER, FILLER, AND NEW DRAIN COVER UNDER SRM 53-04 FIGURE 38 SHEET 23 VIEW H.SDR AALA20090804TUL03Cusp Web · crackedCRACK IN LEFT CUSP AT STATION 810 UNDER HORSE COLLAR. INSTALLED DOUBLER UNDER AARD 53-20-00-16.SDR AALA20090730TUL04Frame · damagedTUL - GUSSET AT G5 GALLEY UPPER BAYONET STATION 1287 LEFT SIDE BELOW LONG NUMBER FIVE L HAS FOUR MISDRILLED HOLES. INSTALLED NEW GUSSET AT G5 GALLEY UPPER / BAYONET STATION 1287 LEFT SIDE BELOW LONG NUMBER FIVE L UNDER SRM 51-30-05.SDR AALA20090724TUL32Shear Tie · corrodedTUL - AFT CARGO HAS CORROSION ON SHEAR TIE AT STATION 1231 BETWEEN L28R-29R. INSTALLED NEW SHEAR TIE UNDER SRM 51-30-00.SDR AALA20090730TUL12Cusp Web · damagedTUL - HOLE IN CUSP MEMBRANE JUST INBOARD OF FORWARD ENTRY DOOR AT STATION 185. INSTALLED REPAIR DOUBLER PER AARD 53-20-00-16.SDR AALA20090724TUL24Shear Tie · crackedAFT ACCESS SHEAR TIE CRACKED AT 1401 BELOW LONG 15L. REPLACED CRACKED SHEAR TIE UNDER SRM 51-01.SDR AALA20090724TUL23Frame · crackedAFT ACCESS 1497 CANT FRAME CRACKED BELOW RIGHT LOUVER BOX. INSTALLED DOUBLER AND FILLER UNDER AARD 53-10-00-17.SDR AALA20090724TUL21Skin · dentedTUL - SKIN DENTED STATION 228 L18L. INSTALLED EXTERNAL DOUBLER UNDER SRM 53-04 FIGURE 12B.SDR AALA20090724TUL20Frame · damagedTUL - UNUSED RIVET HOLES IN FRAME STATION 1287 BETWEEN L4R AND L5R. INSTALLED DOUBLER UNDER SRM 53-03-00.SDR AALA20090723TUL38Beam · corrodedHEAVY CARGO/AFT CORROSION ON DOOR CUTOUT BEAM HORIZONTAL LEG OUTBOARD EDGE STATION 1155 TO STATION 1212. INSTALLED DOOR BEAM DOUBLER PER AARD 53-10-00-3.SDR AALA20090723TUL36Longeron · corrodedLONGERON 29 CORRODED BETWEEN STATION 1285-1288. CUT OUT CORRODED SECTION OF L29 BETWEEN STATION 1277-1295 AND INSTALLED NEW LONGERON EXTRUSION AND REPAIR SPLICE PER SRM 53-02-00 FIG 18 AND AARD 53-00-00-5.SDR AALA20090721DFW01Pump · failedDFW - ON DESCENT PASSING ABOUT FL310 RUDDER CONTROL MANUAL LIGHT ILLUMINATED FOLLOWED BY RIGHT HYDRAULIC PRESS LOW LIGHT. RIGHT HYDRAULIC PRESSURE INDICATED 500 PSI, FOLLOWED CHECKLIST RIGHT PRESS REMAINED AT 500 PSI, LEFT PRESS WAS NORMAL. AT APPROX 10,000 SDR AALA20090721TUL18Stop Fitting · crackedFORWARD CARGO DOOR HAS CRACKED FORWARD CENTER STOP BRACKET. REMOVED AND REPLACED FORWARD CENTER STOP BRACKET PER ESO 80174.SDR AALA20090724TUL06Cusp Web · corrodedTUL - CARGO HAS CORROSION ON BOTTOM SURFACE OF RIGHT CUSP BETWEEN STATION 1022-1041 AFT. REPAIRED UNDER AARD 53-20-00-16.SDR AALA20090724TUL01Mount · corrodedTUL - CORROSION ON OUTBOARD GALLEY MOUNT AT STATION 160. INSTALLED G-1 TIE DOWN MOUNT FITTING PER SRM 51-01.SDR AALA20090723TUL34Angle · corrodedCORROSION ON AFT SIDE OF DOUBLER / STIFFENER (PLOW ANGLE) AT STATION 1338 L29R. REPLACED PLOW ANGLE PER SRM 51-30-05.SDR AALA20090721MCI01Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK WILL NOT HOLD CHARGE. REPLACED BATTERY PACK.SDR AALA20090721LGA08Battery Pack · dischargedLEFT FORWARD OVERWING DOOR LOWER EXIT SIGN INOPERATIVE. REMOVED AND REPLACED BATTERY AT BIN 20DEF EXIT SIGN, OPS CHECK GOOD.SDR AALA20090721LGA07Battery · dischargedRIGHT FORWARD OVERWING DOOR LOWER EXIT SIGN INOPERATIVE. REMOVED AND REPLACED BATTERY AT BIN 20DEF. EXIT SIGN OPS CHECK GOOD.SDR AALA20090721LGA06Battery Pack · dischargedCEILING EMERGENCY LIGHTS INOPERATIVE FROM ROW 23-27. REMOVED AND REPLACED BATTERY PACK AT BIN 25DEF CEILING, OPS CHECK GOOD.SDR AALA20090721LGA05Battery Pack · failedEMERGENCY LIGHT BATTERY PACK IN CABIN FAILED TEST. REPLACED BATTERY PACK IN CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20090721LGA04Battery Pack · failedEMERGENCY LIGHT BATTERY PACK FOR OVERHEAD LIGHTS FAILED TEST. REPLACED EMERGENCY LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20090721LGA03Battery Pack · dischargedSEAT MOUNTED EMERGENCY LIGHTS INOPERATIVE FROM ROW 3 TO ROW 20. REMOVED AND REPLACED BATTERY AT FORWARD LAVATORY DOOR DROP DOWN. SEAT EMERGENCY LIGHTS OPS CHECK GOOD.SDR AALA20090720TUL02Pan · gougedAFT CARGO DOOR 2492, GOUGE IN PAN ON AFT SIDE OF DOOR BY NR 5 STOP PAD FITTING. INSTALLED DOUBLER PER ESO 80174 AND AARD 52-30-00-1 PAGE 2 1/5/94.SDR AALA20090723TUL19Frame · corrodedCORROSION ON AFT SIDE OF FRAME 1250 L27L-L28R. REMOVED CORROSION AND INSTALLED J-ANGLE. REPAIRED UNDER AARD 53-10-00-14.SDR AALA20090730TUL15Cusp Web · crackedTUL - LEFT CUSP IS CRACKED BETWEEN STATION 218 AND 237. REPLACED SECTION OF CUSP UNDER AARD 53-20-00-16.SDR AALA20090724TUL03Mount · corrodedTUL - CORROSION ON NUMBER TWO GALLEY MOUNT END OF SEAT TRACK NUMBER SIX. REMOVED AND REPLACED GALLEY MOUNT PER SRM 51-01.SDR AALA20090724TUL02Mount · corrodedTUL - CORROSION ON GALLEY MOUNT AT STATION 218. REMOVED AND REPLACED GALLEY MOUNT PER SRM 51-01.SDR AALA20090723TUL21Skin · corrodedCORROSION UNDER PLASTIC DRAIN COVER ON FUSELAGE SKIN STATION 731 BETWEEN L29R AND L30. REMOVED CORROSION PER SRM 51-10-03 AND REPAIRED PER AARD 53-30-00-9.SDR AALA20090723TUL20Intercostal · crackedINTERCOSTAL CRACKED AT AFT END BELOW CABIN FLOOR AT CENTERLINE STATION 1309. REPLACED INTERCOSTAL PER SRM 51-30-5.SDR AALA20090720SFO01Battery Pack · dischargedSFO - OVERHEAD EMERGENCY LIGHTS IN CABIN INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS IN CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20090724TUL19Stiffener · crackedTUL - CRACK IN RADIUS AT UPPER END OF STIFFENER ON FORWARD SIDE OF STATION 1338 BULKHEAD ABOVE CENTER OF VAULT DOOR JAMB. INSTALLED DOUBLER UNDER AARD 53-10-00-15.SDR AALA20090730TUL01Cargo Track · corrodedTUL - CORROSION IN AFT CARGO TIE DOWN TRACK. INSTALLED NEW TIE DOWN TRACK.
Back to Boeing DC-9-83