Boeing DC-9-83

Service difficulty reports · 16,530

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC983'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASAA0380825Skin · crackedOKC - DURING C-CHECK, FOUND FUSELAGE SKIN IS CRACKED AT LEFT AFT NLG DOOR CUTOUT. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 53-05. (M)Dec 12, 2003 · N964AS · Doug DC983 · Fuselage Main, Plate/SkinSDR ASAA0380824Web · corrodedOKC - DURING C-CHECK, FOUND CUSP WEB CORRODED ON RIGHT SIDE FS 1250. REMOVED DAMAGED AREA. INSTALLED DOUBLER PER SRM 51-70-4. (M)Dec 12, 2003 · N964AS · Doug DC983 · Fuselage Miscellaneous StructureSDR ASAA0380826Skin · dentedOKC - DURING C-CHECK, FOUND FUSELAGE SKIN IS DENTED AT FS 360. RECONTOURED/COLD-WORKED SKIN. INSTALLED DOUBLER PER SRM 53-04. (M)Dec 12, 2003 · N964AS · Doug DC983 · Fuselage Main, Plate/SkinSDR ASAA0380823Connector · disconnectedSEA PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE NEAR AFT GALLEY. RECONNECTED MODULE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)Dec 11, 2003 · N961AS · Doug DC983 · Light System WiringSDR ASAA0380822Skin · dentedSEA PREFLIGHT CHECK, FOUND FORWARD PAX DOOR DENTED, CAUSING DOOR TO BE DIFFICULT TO OPEN. REPAIRED DENT PER SRM 52-05. RERIGGED DOOR. DOOR THEN OPERATED PROPERLY. (M)Dec 10, 2003 · N958AS · Doug DC983 · Passenger/Crew DoorsSDR AALA20031415Battery Pack · not seatedORD) OVERWING LOWER SIDE WALL EMERGENCY LIGHT AT ROW 2 INOPERATIVE. RESEATED BATTERY PACK FOR OVERWING LOWER SIDE WALL EMERGENCY LIGHT AT ROW 2. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDDec 10, 2003 · N591AA · Doug DC983 · Emergency LightingSDR ASAA0380821Module · disconnectedSEA - PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 6-10. RECONNECTED MODULE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)Dec 9, 2003 · N962AS · Doug DC983 · Emergency LightingSDR GTIA031043Floorboard · damagedFOUND CABIN CENTER FLOORBOARD STATION 270 IS SPONGY. REMOVED CABIN CENTER FLOORBOARD. FABRICATED NEW CABIN CENTER FLOORBOARD. INSTALLED FS 270 FLOORBOARD. (M)Dec 9, 2003 · N831NK · Doug DC983 · Fuselage Floor PanelSDR AALA20031400Battery Pack · dischargedDFW OVERWING EXIT LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR OVERWING EXIT LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Dec 8, 2003 · N9617R · Doug DC983 · Emergency LightingSDR AALA20031395Battery Pack · dischargedDFW FORWARD GALLEY OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD GALLEY OVERHEAD EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Dec 7, 2003 · N439AA · Doug DC983 · Emergency LightingSDR ZW0A0306501Connector · looseTHE EGRESS LIGHTS WERE INOPERATIVE BETWEEN CABIN ROWS 27 AND 30. SECURED LOOSE CONNECTOR AT ROW 30. CHECK-C 11-23-03 STL. --CLOSED---Dec 7, 2003 · N939AS · Doug DC983 · Emergency LightingSDR WX0300027Windshield · crackedEN ROUTE FROM LAS TO DSM, THE FO'S WINDSHIELD CRACKED AFTER TAKEOFF. THE FLIGHT RETURNED TO LAS AND PERFORMED AN OVERWEIGHT LANDING. MAINTENANCE REMOVED AND REPLACED THE WINDSHIELD AND PERFORMED AN OVERWEIGHT LANDING INSPECTION. NO DISCREPANCIES WERE NOTED.Dec 4, 2003 · N891GA · Doug DC983 · Flight Compartment WindowsSDR GTIA031037Wire · crossedFOUND LT FORWARD LOWER AIRSTAIR EMERGENCY LIGHT INOPERATIVE, BAD SOCKET. TROUBLESHOT SYSTEM FOUND WIRES CROSSED AT POWER SUPPLY. REWIRED POWER SUPPLY AND LIGHT SOCKETS. (M)Dec 4, 2003 · N832NK · Doug DC983 · Light System WiringSDR ASAA0380820Door · out of rigSEA PREFLIGHT CHECK, FORWARD PAX DOOR DIFFICULT TO OPEN. RERIGGED DOOR. DOOR THEN OPERATED PROPERLY. (M)Dec 3, 2003 · N958AS · Doug DC983 · Passenger/Crew DoorsSDR ASAA0380819Skin · dentedPREFLT CHECK, FORWARD PAX DOOR SKIN IS DENTED CAUSING DOOR TO BE HARD TO OPEN. REPAIRED DENT PER SRM 52-05 AND 51-10-03. DOOR THEN OPERATED PROPERLY. (M)Dec 3, 2003 · N958AS · Doug DC983 · Passenger/Crew DoorsSDR AALA20031369Charger · inoperativeDFW AFT LAV AREA CEILING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY/CHARGER ASSEMBLY FOR AFT LAV AREA CEILING EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Dec 3, 2003 · N76200 · Doug DC983 · Emergency LightingSDR ZW0A0306401Connector · damagedTHE AFT CABIN EGRESS LIGHTING WAS INOPERATIVE. REPAIRED DAMAGED FLOOR CONNECTION AND RESEATED BATTERIES IN THE POWER SUPPLY. CHECK-C 9-15-03 MCI.Dec 3, 2003 · N9404V · Doug DC983 · Emergency LightingSDR AALA20031363Battery · looseRDU AFT VENTRAL STAIR AREA OVERHEAD EMERGENCY LIGHTS INOPERATIVE. RESEATED BATTERIES FOR AFT VENTRAL STAIR AREA. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDDec 2, 2003 · N976TW · Doug DC983 · Emergency LightingSDR ASAA0380818Floor Panel · crackedOAK - FOUND 15K CHECK, FOUND FLOOR PANEL CRACKED AT FS 1287-1309. INSTALLED DOUBLER PER SRM 53-05. (M)Dec 1, 2003 · N950AS · Doug DC983 · Fuselage Floor PanelSDR ASAA0380817Shear Tie · corrodedOAK - DURING 15K CHECK, FOUND SHEAR TIE CORRODED AT FS 1257. REPLACED SHEAR TIE PER SRM 51-30-2. (M)Dec 1, 2003 · N950AS · Doug DC983 · Fuselage Main, StructureSDR GTIA030958Switch · inoperativeFLL - FORWARD EMERGENCY EXIT ILGHT ASSEMBLY HAS BAD ON/OFF SWITCH. REMOVED AND REPLACED FORWARD EMERGENCY EXIT LIGHT ASSEMBLY, OPS CHECK NORMAL. (M)Dec 1, 2003 · N824NK · Doug DC983 · Emergency LightingSDR AALA20031361Control Unit · faultyPDX T1010/01 EN ROUTE PDX-DFW RIGHT HAND BUS FAULT AND POPPING CIRCUIT BREAKERS. RETURNED PDX AND LANDED WITHOUT INCIDENT. REMOVED AND REPLACED AIRCRAFT BUS CONTROL UNIT AND R2-36 RELAY SYSTEM PER MM 24-20-08-4. SYSTEM GROUND CHECKED NORMAL OPERATION.Dec 1, 2003 · N965TW · Doug DC983 · AC Power Distribution SystemSDR AALA20031356Battery Pack · dischargedBOS LT AFT STAIRWELL EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR LEFT AFT STAIRWELL EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDNov 30, 2003 · N570AA · Doug DC983 · Emergency LightingSDR AALA20031345Battery Pack · dischargedDFW OVERHEAD EMERGENCY EXIT LIGHT BETWEEN ROWS 18-20 INOPERATIVE. REPLACED BATTERY PACK FOR OVERHEAD EMERGENCY EXIT LIGHT BETWEEN ROWS 18-20. SYSTEM GROUND CHECKED NORMAL OPERATION.--CLOSED--Nov 30, 2003 · N9625W · Doug DC983 · Emergency LightingSDR GTIA030956Burner Can · damagedFOUND CREW MENTIONED STRONG FUEL ODOR IN CABIN DURING APU OPERATION. STRONG FUEL ODOR IN CABIN. FUEL LEAKING FROM FUEL ATOMIZER. FOUND A.N. FITTING FROM FUEL LINE TO FUEL ATOMIZER LOOSE. TIGHTEN JAM NUT ON A.N. FITTING. LEAK CHECK GOOD, NO FUEL ODOR NOTEDNov 28, 2003 · N815NK · Doug DC983 · APU Core EngineSDR CA031208007Augment Valve · failed(CAN) RT ICE PROTECTION TEMPERATURE HIGH ILLUMINATED IN CLIMB. AIRCRAFT LANDED. MAINTENANCE REPLACED THE RT AUGMENTATION VALVE P/N 392710-2, S/N 3798 AND THE RT ICE ANTICIPATORS P/N 129110-2-1, S/N P118 AND P/N 129112-1-1, S/N N4216. SYSTEM WAS SERVICEABLE FOLNov 28, 2003 · Doug DC983 · Ice DetectionSDR MEX2003540Pump · failedAIRCRAFT RETURNED TO GATE DUE TO THE LT ENGINE HYDRAULIC PUMP DID NOT SHUTOFF IN THE 'OFF' SWITCH POSITION. THE HYDRAULIC PUMP WAS REPLACED AND THE SYSTEM WAS TESTED IAW MM 29-10-01. (M)Nov 28, 2003 · N838AM · Doug DC983 · Hydraulic Pump (Electric/Engine), MainSDR GTIA030954Light · inoperativeMCO - EMERGENCY EXIT IDENTIFIER LIGHT FOR AFT CABIN DOOR INOPERATIVE. REPAIRED WIRES FOR EMERGENCY EXIT IDENTIFIER AT AFT CABIN DOORS, OPS CHECK OK. (M)Nov 27, 2003 · N827NK · Doug DC983 · Cargo Compartment LightingSDR AALA20031337Battery Pack · dischargedTUL LEFT AND RIGHT OVERWING ESCAPE HATCH EXIT SIGN LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR LEFT AND RIGHT OVERWING ESCAPE HATCH EXIT SIGN LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Nov 27, 2003 · N9625W · Doug DC983 · Emergency LightingSDR ASAA0380813Floorboard · puncturedOKC - DURING 15K CHECK, FOUND CABIN FLOORBOARD HAS PUNCTURE AT FS 920-1003. BOND-REPAIRED PER SRM 51-70-3. (M)Nov 26, 2003 · N960AS · Doug DC983 · Fuselage Floor PanelSDR ASAA0380812Frame · corrodedOKC - DURING 15K CHECK, FOUND FRAME CORRODED AT FS 1309. REMOVED DAMAGED SECTION. INSTALLED ANGLE, PLATE, AND SPLICES PER SRM 53-03. (M)Nov 26, 2003 · N960AS · Doug DC983 · Fuselage Main, FrameSDR ASAA0380815Frame · chafedOKC - DURNG 15K CHECK, FOUND FRAME CHAFED AT FS 1418. REMOVED DAMAGE. INSTALLED ANGLE, PLATE, AND FILLER PER SRM 53-03 AND 51-10-3. (M)Nov 26, 2003 · N960AS · Doug DC983 · Fuselage Main, FrameSDR ASAA0380814Floorboard · delaminatedOKC - DURING 15K CHECK, FOUND CABIN FLOORBOARD IS DELAMINATED AT FS 808-823. BOND-REPAIRED PER SRM 51-70-3. (M)Nov 26, 2003 · N960AS · Doug DC983 · Fuselage Floor PanelSDR ASAA0380811Skin · crackedOKC - DURING 15K CHECK, FOUND RIGHT WING LEADING EDGE CRACKED. INSTALLED DOUBLER AND FILLER PER SRM 57-06 AND 51-10-3. (M)Nov 26, 2003 · N960AS · Doug DC983 · Wing, Plate/SkinSDR CA040107001Ball Joint · worn(CAN) THRUST REVERSER FOLLOW-UP CABLE FOUND DETACHED. BALL JOINT CONNECTED TO ROD FOUND DISMANTLED FROM ITS JOINT SHELL.Nov 26, 2003 · Doug DC983 · Engine Thrust ReverserSDR ASAA0380816Web · corrodedOAK - DURING 15K CHECK, FOUND FLOOR MEMBRANE CORRODED AT FS 763. REMOVED DAMAGED AREA. INSTALLED DOUBLER. (M)Nov 26, 2003 · N950AS · Doug DC983 · Fuselage Miscellaneous StructureSDR AALA20031355Engine · malfunctionedDFW T1357/26 EN ROUTE DFW-TUS LEFT HAND ENGINE LOW OIL PRESSURE. CREW REDUCED POWER OF ENGINE TO IDLE. LANDED ELP WITHOUT INCIDENT. REPLACED LEFT HAND ENGINE. SYSTEM GROUND CHECKED NORMAL OPERATION.Nov 26, 2003 · N9621A · Doug DC983 · Engine (Turbine/Turboprop)SDR ASAA0380810Floor Support · corrodedOAK - DURING 15K CHECK, FOUND FLOOR SUPPORT CORRODED AT FS 1099 TO 1212. REPLACED FLOOR SUPPORT PER SRM 51-10-4. (M)Nov 25, 2003 · N950AS · Doug DC983 · Fuselage Miscellaneous StructureSDR GTIA031022Floorbeam · crackedFOUND PAX CABIN FLOORBEAM WEB CRACKED AT STATION 120 LBL 6. CUT OUT DAMAGED AREA. FABRICATED NEW WEB SECTION AND DOUBLER. INSTALLED NEW WEB SECTION AND DOUBLER. (M)Nov 25, 2003 · N831NK · Doug DC983 · Fuselage Main, Floor BeamSDR CA031202001Washer · failed(CAN) DURING ENGINE INSTALLATION, COULD NOT TORQUE ENGINE MOUNT YOKE BOLT P/N 3935739-1 IAW MM SECTION 20-10-14 PAGE 201. UNABLE TO COMPRESS, THE INNER PLI WASHER RING OF PLI WASHER SET P/N PL120-117-8. THESE PLI WASHERS WERE PROVIDED FROM FOLLOWING SUPPLIERS:Nov 25, 2003 · Doug DC983 · Engine Mount SectionSDR ASAA0380803Connector · looseSEA PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 23. RECONNECTED MODULE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)Nov 24, 2003 · N948AS · Doug DC983 · Emergency LightingSDR GTIA031033Floor Panel · crackedFTW - FOUND COCKPIT RUDDER PEDAL FLOOR PANEL CRACKED. REPAIRED COCKPIT RUDDER PEDAL FLOOR PANEL. (M)Nov 24, 2003 · N832NK · Doug DC983 · Fuselage Floor PanelSDR AALA20031318Battery Pack · dischargedORD CEILING EMERGENCY LIGHTS OVER ROWS 29D AND 28D INOPERATIVE. REPLACED BATTERY PACK FOR CEILING EMERGENCY LIGHTS OVER ROWS 29D AND 28D. SYSTEM GROUND CHECKED NORMAL OPERATION.Nov 24, 2003 · N567AM · Doug DC983 · Emergency LightingSDR ASAA0380809Skin · dentedOKC - DURING C-CHECK, FOUND SKIN DAMAGED, DENTED, AT FS 229. COLD-WORKED DENT AND INSTALLED DOUBLER PER SRM 53-04. (M)Nov 23, 2003 · N962AS · Doug DC983 · Fuselage Main, Plate/SkinSDR ASAA0380808Web · gougedOKC - DURING C-CHECK, FOUND FLOOR CUSP WEB IS GOUGED AT FS 180. REMOVED DAMAGED SECTION AND INSTALLED DOUBLER PER SRM 53-01. (M)Nov 23, 2003 · N962AS · Doug DC983 · Fuselage Miscellaneous StructureSDR ASAA0380807Skin · dentedOKC - DURING C-CHECK FOUND DAMAGED, DENTED, AT FS 229-245. REMOVED DAMAGED SECTION AND INSTALLED DOUBLER AND STRAPS PER SRM 53-04. (M)Nov 23, 2003 · N962AS · Doug DC983 · Fuselage Main, Plate/SkinSDR ASAA0380806Floorboard · corrodedOKC - DURING C-CHECK, FOUND CABIN FLOORBOARD CORRODED FS 180-200. REPLACED FLOORBOARD PER SRM 53-05. (M)Nov 23, 2003 · N962AS · Doug DC983 · Fuselage Floor PanelSDR ASAA0380805Floorboard · corrodedOKC - DURING C-CHECK, FOUND CABIN FLOORBOARD HAS CORRODED INSERTS AT FS 200-256. REPLACED FLOORBOARD PER SRM 53-05. (M)Nov 23, 2003 · N962AS · Doug DC983 · Fuselage Floor PanelSDR ASAA0380804Floorboard · corrodedOKC - DURING C-CHECK, FOUND CABIN FLOORBOARD HAS CORRODED INSERTS AT FS 160-200. REPLACED FLOORBOARD PER SRM 53-05. (M)Nov 23, 2003 · N962AS · Doug DC983 · Fuselage Floor PanelSDR ASAA0380802Spring · brokenLAX PREFLIGHT CHECK, LEFT CAPTAINS SLIDING CLEARVIEW WINDOW WOULD NOT OPEN. REPLACED UPPER LOCK BAR SPRING. WINDOW THE OPERATED PROPERLY. (M)Nov 23, 2003 · N958AS · Doug DC983 · Flight Compartment Windows
Back to Boeing DC-9-83