Boeing DHC-8-102
Service difficulty reports · 9,272
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA130508010Actuator · cracked(CAN) DURING TAXI FOR FLIGHT, THE CREW RECEIVED THE NR 1 ISO CAUTION LIGHT, ROLL INBD HYD CAUTION LIGHT RESULTING IN FLUID QUANTITY AT .5. ACFT RETURNED. MAINTENANCE ACTION FOUND THAT THE RT OTBD, SPOILER ACTUATOR LEAKING HEAVILY AND FOUND TO BE CRACKED. THSDR CA130508008Connector · failed(CAN) DURING CLIMB, FLIGHT CREW RECEIVED A, FLAP POWER, CAUTION MESSAGE AFTER SELECTING FLAP, FROM 5. FLIGHT CREW TRIED TO MOVE THE FLAPS BACK TO 5 DEGREES WITH NO SUCCESS, FLAPS REMAINED AT 3. THE AIRCRAFT RETURNED AND LANDED WITHOUT FURTHER INCIDENT. MAINSDR HNAA2013050600257Battery Pack · dischargedTOP EMERGENCY SIGNS FOR RT FWD EXIT AND TOP SIGH NEAR F/A PANEL, AND EXTERIOR RT FWD EMERGENCY LIGHTS ARE INOP. FOUND EMERGENCY BATTERY TO BE DEAD. R & R BATTERY PACK, OPS CHECK GOOD.SDR HNAA2013050600256Bulb · burned outF/A EMERGENCY SWITCH "GREEN" LIGHT IS INOPERATIVE. R & R F/A EMERGENCY SWITCH GREEN LIGHT. RE-SECURED LENS, OPS CHECKED GOOD.SDR HNAA2013050600255Bulb · burned outGREEN "NORM" EMERGENCY LIGHT AT SWITCH ABOVE WARDROBE DOES NOT ILLUMINATE. R & R LIGHT BULB, OPS CHECK GOOD.SDR HNAA2013050600254Actuator · inoperativeAFTER TAKE OFF, DURING GEAR RETRACTION, NLG INDICATED UNSAFE AND ALL GEAR DOORS STAYED OPEN. R & R NLG RETRACT ACTUATOR. OPS CHECKED GOOD ON GROUND IAW AMM 32-30-31. OK FOR SERVICE AT THIS TIME.SDR CA130506007Line · chafed(CAN) CREW ADVISED LOW NR 1 HYDRAULIC QTY AND WHEN THEY SELECTED FLAPS DOWN, THEY RECEIVED A NR 1 HYD ISO VALVE CAUTION AND THE FLAPS STAYED AT 0. CREW CONDUCTED A FLAPLESS LANDING. MAINTENANCE FOUND THE NR 1 ENGINE EDP PRESSURE LINE, PN 82970410-119, AND CSDR HNAA2013050300251Connector · dirtyFLAP DRIVE CAUTION LIGHT FLICKERING DURING CRUISE FLIGHT. ON CONTINUOUSLY FOR APPROX 30 MINUTES. STAYED OUT AFTER LANDING. FLAP OPS NORMAL. INSPECTED AND CLEANED CONNECTOR ON TORQUE SENSOR. GROUND RAN AIRCRAFT. FLAPS OPS CHECKED NORMAL AT THIS TIME. LIGSDR HNAA2013050300250Bulb · failedLEFT AFT FUSELAGE EMERGENCY LIGHT IS INOPERATIVE. R & R BULB IAW AMM 33-51-00.SDR HNAA2013050300249Bulb · failedEMERGENCY SIDEWALL LIGHTS ARE INOP AT ROW 4AC. REMOVED LENS. R & R ONE BULB. OPS CHECKED GOOD. REINSTALLED LENS.SDR CA130513002Engine · leaking(CAN) THE PILOT REPORTED OIL ODOR IN THE CABIN DURING TRANSITIONING TO FLIGHT IDLE AS THEY WERE ABOUT TO TAXI. INSPECTION REVEALED OIL WETNESS AT THE HIGH PRESSURE IMPELLER AREA OF ENGINE NR 2. TROUBLESHOOTING IS ONGOING AND FOCUSING ON A POSSIBLE FAULTY HANDSDR CA130507011Ahrs · failed(CAN) ON ARRIVAL INTO THE NR 1 AHRS TOPPLED AND LOST THE FLIGHT DIRECTOR. FAULTY AHRS PN:7003360-941, SN: 88071070. REPLACED AND GROUND CHECKS CARRIED OUT AND CHECKED SERVICEABLE. ACFT RETURNED TO SERVICE. ON THE CLIMBOUT RT AFTER REPLACING THE AHRS, NR 1 SDR HNAA2013050100247Tru · failedRIGHT AC BUSS CAUTION LIGHT ILLUMINATED IN FLIGHT WITH NO LOOSE ON BUSS. GROUND RAN ACFT AND FOUND RT TRU LOAD AT .07. R & R RT TRU IAW MM 24-31-00. OPS CHECKED GOOD.SDR HNAA2013050100246Warning Light · false activationNR 2 ENGINE DRIVEN PUMP CAUTION LIGHT ILLUMINATED WITH POWER LEVERS ABOVE FLIGHT IDLE. NR 2 HYD PUMP CAUTION LIGHT WAS DEACTIVATED IAW SP 29.2.SDR HNAA2013050100245Hose · disconnectedBOTH LT AND RT DEICE BOOTS WILL NOT INFLATE IN NR 5 POSITION. FOUND DEICE HOSE DISCONNECTED AT TAIL RT INBD BOOT. RESECURED HOSE AS REQUIRED. OPS CHECKED GOOD.SDR HNAA2013050100244Wheel · misinstalledBRAKES APPEAR TO BE NOT OPERATING AFTER LANDING. FOUND NR 4 MAIN WHEEL ASSY LOOSE AND INCORRECTLY INSTALLED. FOUND DAMAGE ON NR 4 AXLE. R & R SHOCK STRUT IAW WC 32-20-06F. PERFORMED HIGH SPEED TAXI. OPS CHECKED GOOD.SDR HNAA2013050100243Wire · damagedRT MLG ALTERNATE INDICATION IS INOPERATIVE. FOUND BROKEN WIRE. INSTALLED ENVIRONMENTAL SPLICE IAW STANDARD PRACTICE. OPS CHECKED GOOD. OK FOR SERVICE. LAST NIGHT, MX R & R SPLICES 3261-E1, 3262-E2. REPLACED LED 3262-CR1 AND 3262-CR2. NO FIX. CHECKED RESISTASDR CA130429001Flap System · malfunctioned(CAN) UPON FLAPS RETRACTION FROM 5" FLIGHT CREW RECEIVED A "FLAP POWER" CAUTION MESSAGE AND FLAPS REMAINED AT 5". WEATHER CONDITION/FUEL CONSUMPTION WAS ASSESSED AND FLIGHT CONTINUED TO DESTINATION, ACFT LANDED WITHOUT FURTHER INCIDENT. DECISION WAS LATER TAKSDR CA130507010Hinge · damaged(CAN) WHILE COMPLETING A C-CHECK, INSPECTION FOUND THE ELEVATOR CENTER HINGE ARM ASSY ATTACH BOLTS TO HORIZONTAL STABILIZER ELONGATED. THIS ALLOWED FOR EXCESSIVE HORIZONTAL PLAY IN THE CENTER HINGE ATTACH POINT. ELEVATOR CENTER HINGE ARM REPLACED.SDR HNAA2013042600238Bearing · corrodedRT ELEVATOR ANCHOR SPRING BEARING CORRODED. REMOVED SOME CORROSION ON INBD SIDE . R & R INBD AND OTBD BEARING IN RT ELEVATOR ANCHOR SPRING ASSY IAW DWR 82760113.SDR HNAA2013042600237Floor Support · corrodedLOWER CARGO BAY FLOOR SUPPORT ANGLE CORRODED. LT SIDE ANGLE OUT OF LIMITS. REMOVED LT AND RT ANGLES. BLENDED LIGHT CORROSION ON RT ANGLE, ALODINED AND PRIMED. REINSTALLED IAW DWG NR 85330112. INSTALLED NEW ANGLE ON LT SIDE IAW DWG 85330112.SDR HNAA2013042600236Seal · leakingWITH APU RUNNING, WITHOUT GROUND POWER UNIT, ELECTRICAL BURNING ODOR AND SMOKE COMING FROM CARGO BAY / APU AREA. INSPECTED AND FOUND APU STARTEF GENERATOR TO BE THE CAUSE OF SMOKE AND FUMES. NO DAMAGE NOTED. REMOVED APU STARTER GENERATOR AND FOUND OIL SOAKESDR HNAA2013042400233Bulb · failedEMERGENCY FLOOR PATH LIGHT HAS VERY DIM LIGHT AT ROW 8. R & R BULB IAW MM 33-51-00.SDR HNAA2013042200231Bulb · inoperativeEMERGENCY LIGHTS ARE NOT WORKING. R & R BULBS. OPS CHECKED GOOD.SDR HNAA201304220023Connector · corrodedRADAR DOES NOT PAINT WEATHER OR GROUND. RADAR DISPLAY SPOKES, FOUND CORROSION IN CONNECTOR 3441-P1001. R & R CONNECTOR IAW MM 20-45-06SDR CA130423003Acm · failed(CAN) IN CRUISE FLIGHT AT FL 190, THE CABIN TEMP WENT UP TO 28 DEGREES AND WAS NOT CONTROLLABLE IN AUTO OR MANUAL. SHORTLY AFTER THE CABIN PRESSURE WARNING LIGHT CAME ON, THE CREW CARRIED OUT A RAPID DESCENT TO 8000 FT. MAINTENANCE INVESTIGATION FOUND THE AISDR HNAA2013041700223Hose · detachedCREW REPORTS SMOKE FROM TAILCONE AND APU DOOR VENT. APU OPS OK WITH NO FIRE INDICATIONS. INSPECTION APU COMPARTMENT, ATTACHED HOSE AT APU EXHAUST.SDR HNAA2013041700222Bulb · burned outROW 7 EMERGENCY LIGHT INOPERATIVE. R & R BULB.SDR HNAA2013041700227Lamp · burned outEMERGENCY EXIT CEILING LIGHT AT ROW 7 IS INOPERATIVE. RELAMPED EMERGENCY CEILING LIGHT AT ROW 7 SECURED COVER USING ATTACHED HARDWARE, OPS CHECK GOOD.SDR HNAA2013041700226Unknown · smokeF/A REPORTS SMOKE FROM NR 2 NACELLE. OPENED NR 2 NACELLE AND INSPECTED. NO LEAKS OR SMOKE NOTED. GROUND RAN ENG AND OPS NORMAL W/ NO DISCREPANCIES.SDR HNAA2013041500221Bulb · burned out1ST RED FLOOR EMERGENCY LIGHT INOPERATIVE. R & R BULB FOR 1ST RED FLOOR EMERGENCY LIGHT RESECURED FLOOR TRIM.SDR HNAA2013041500220Brush Block · malfunctionedEMERGENCY LIGHTS FLICKERING IN FLT (PROP HEAT OFF) F/A PANEL LIGHTING INTERMITTENT IN FLT ALSO, CLEANED AND RESEATED BRUSH BLOCKS ON NR 1 AND NR 2 ENGINES. UPPER FWD COWLING ON BOTH ENGINES REMOVED AND REINSTALLED GROUND RUN CHECK GOOD.SDR HNAA2013041500219Brush Block · malfunctionedAFTER TAKEOFF, EMERGENCY LIGHTS FLICKERED ON AND OFF FOR FIVE SECONDS FOR SEVERAL MINUTES. OPERATED NORMALLY FOR DURATION OF FLIGHT. INSPECTED NR 2 ENGINE AND PROP FOR POSSIBLE DEFECTS NONE FOUND. R & R NR 2 ENGINE DE-ICE BRUSH BLOCK IAW 61-10-11. GROUND SDR HNAA2013041500218Brush Block · damagedAFTER TAKE OFF, EMERGENCY LIGHTS FLICKERED ON AND OFF FOR 5 SECONDS FOR A DURATION OF SEVERAL MINUTES. OPS NORMAL THEREAFTER FOR DURATION OF FLIGHT. INSPECTED BOTH PROP ASSEMBLIES AND BRUSH BLOCKS, NO DEFECTS NOTED. CREW GROUND RAN ACFT, OPS CHECK GOOD AT THSDR HNAA2013041000216Selector Valve · malfunctionedSELECTED GEAR DOWN ON APPROACH. LT MAIN UNSAFE LIGHT ILLUMINATED AND PASSENGER REPORTED LT GEAR NOT EXTENDED. EXECUTED GO AROUND AND GEAR EXTENDED ON ITS OWN AFTER APPROX 5 MINUTES. R & R GEAR SELECTOR VALVE WC 32-30-41. NO FIX. R & R UPLOCK ACTUATOR AND SSDR HNAA2013041000215Connector · contaminatedLOST BRAKES DURING TAXI. FOUND NR 1 S/B HYD PUMP CIRCUIT BREAKER OUT. INSPECTED AND FOUND CONNECTOR PLUG CONTAMINATED WITH OIL FROM ENGINE BREATHER. CLEANED AND RESEATED CONNECTOR PLUG. RESET CIRCUIT BREAKER AND GROUND RAN AIRCRAFT. NR 1 HYD PRESSURE NORMSDR HNAA2013040800214Skin · corrodedRT SIDE OF FUSELAGE HAS RIVETS PULLING THROUGH SKIN IN LAVATORY SERVICE AREA. REMOVED CORRODED SKIN AND INSTALLED REPAIRED IAW EA05-2013-011 AND EO8-53-13-0176.SDR HNAA2013040800213Door Frame · corrodedLAVATORY SERVICE DOOR FRAME IS CORRODED AT LOWER SECTION. REMOVED LAV BOX CUT OUT DAMAGE IAW RD8-53-2103. R & R LAV SERVICE DOOR FRAME MACHINED DOUBLER IAW DWG 85320983 AND EA09-2013-011 AND EO8-53-13-0176.SDR HNAA2013040800212Skin · corrodedSMALL AREA OF SKIN SURFACE CORROSION FOUND AT RT CABIN UNDER FLOOR. REMOVED CORRODED SKIN AND INSTALLED REPAIRED PATCH IAW EA05-2013-011 AND EO8-53-13-0176.SDR HNAA2013040500211Frame · corrodedFRAME CORRODED IN FORWARD CABIN UNDERFLOOR RT SIDE AT BS 201, S31S. CUT FRAME AT STR 33 AND REMOVED FRAME SPLICE AT STR 28. FABRICATED NEW SPLICE IAW EA12-2013-122. INSTALLED FRAME IAW EO8-53-13-0138.SDR HNAA2013040500209Wheel · damagedDURING WALK AROUND, CREW FOUND NR 4 WHEEL ASSY DAMAGED. R & R NR 3 AND 4 MAIN WHEEL ASSEMBLIES IAW MM 32-41-11. OK FOR SERVICE.SDR HNAA2013040400208Seat Track · corrodedRT CENTER SEAT TRACK HAS CORROSION, FWD OF BS 600. BLENDED, ALODINED AND PRIMED SEAT TRACK IAW RD8-53-4936. PERFORMED HFEC INSPECTION. NO DEFECTS NOTED.SDR HNAA2013040400207Bracket · corrodedCARGO BAY COVE AREA BRACKET AT BS 591 TO 597 IS CORRODED. BLENDED LIGHT CORROSION FROM BRACKET IAW 51-20-11. INSTALLED BRACKET IAW DWG 85320112. ALODINED AND PRIMED IAW 51-20-16 AND 51-20-36.SDR HNAA2013040400205Threshold · corrodedCARGO BAY THRESHOLD AREA HAS SURFACE CORROSION. CLEANED AND BLENDED MINOR SURFACE CORROSION, ALODINE AND PRIMED SURFACE AREA IAW 51-20-11, 51-20-16 AND 51-20-36.SDR HNAA2013040400206Bracket · corrodedBAG BAY COVE AREA BRACKET IS CORRODED. REMOVED FASTENERS FROM COVE AREA, REMOVED COVER AND BRACKET. INSTALLED NEW BRACKET IAW DWG 85330119. INSTALLED COVE PANEL.SDR HNAA2013040400204Strut · crackedAFT HANDRAIL UPPER SUPPORT STRUT IS CRACKED AT UPPER ATTACHMENT END. R & R HANDRAIL UPPER STRUT AND INSTALLED ORIGINAL HARDWARE.SDR HNAA2013040300196Connector · damagedNR 2 ENGINE FUEL TEMP ERRATIC AND READING HIGHER THAN NORMAL (ABOVE LIMITS). R & R FUEL TEMP BULB AND 2 FUEL TEMP BULB CONNECTOR PLUGS IAW BUILD UP MANUAL 71-00-02. OPS CHECKED GOOD.SDR HNAA2013040300200Bulb · failedROW 4AC AND 4DF EMERGENCY SIDEWALL LIGHTS ARE INOP. REMOVED LENS, REMOVED AND REPLACED BULBS. REINSTALLED LENS. OPS CHECKED GOOD.SDR HNAA2013040300198Socket · damagedSMOKE NOTED FROM OVERHEAD LIGHTS AT ROW 1AC. INSPECTED AND FOUND DAMAGE SOCKET. OVERHEAD LIGHT CIRCUIT BREAKERS S1, S2 AND R2 ARE DEACTIVATED. R & R BALLAST AND LIGHT SOCKET. REACTIVATED OVERHEAD LIGHTS. OPS CHECKED GOOD.SDR HNAA2013040300197Starter Gen · malfunctionedNR 1 DEC GENERATOR HOT CAUTION LIGHT ILLUMINATED IN FLIGHT. R & R NR 1 DC STARTER GENERATOR. OPS CHECKED GOOD IAW 24-30-02R. OK FOR SERVICE.
Back to Boeing DHC-8-102