SDR CA111025004Line · punctured(CAN) HYD LEAK FOUND ON OTBD NR 2 NACELLE. FOUND TO BE COMING FROM A PIN HOLE IN THE EMERGENCY BRAKE PRESSURE HYD LINE. LINE REPLACED AND SYSTEM TESTED. ACFT RETURNED TO SERVICE.SDR CA111024004Generator · burned(CAN) THE ACFT WAS STRUCK BY LIGHTNING INBOUND. AT THE TIME OF THE STRIKE THE NR 1 DC GENERATOR WENT OFF LINE BUT WAS RESET SUCCESSFULLY. DURING THE LIGHTNING STRIKE INSP DAMAGE WAS FOUND AT THE FOLLOWING LOCATIONS ON THE ACFT: THE LT AILERON TIP HAD A HOLE SDR V0XR2011102000002Angle · corrodedCORROSION FOUND ON CLIP ANGLES THAT TIE FRAME X = 488.5 TO STRINGER 23L, FWD AND AFT SIDE. AFTER FURTHER INVESTIGATION FOUND CLIP ANGLES THAT TIE FRAME X = 488.5 TO STRINGER 23L FWD AND AFT SIDE TO BE OUT OF LIMITS. FABRICATED NEW ANGLES OF 0.032 IN 2024-T3,SDR V0XR201110200001Doubler · corrodedAIRSTAIR DOUBLER AT THE FWD SIDE OF TOP STEP IS CORRODED. R & R DOUBLER IAW AMM 52-10-00-02 AND SRM 51-10-00.SDR CA111021007Wire · shorted(CAN) DURING TAXI OUT, THE CREW NOTICED A STRONG BURNING ODOR IN THE CABIN AND COCKPIT. THE CREW ELECTED TO STOP IN THE CENTRAL DEICE FACILITY AND EVACUATE THE ACFT. DURING MX T/S THE FOLLOWING ADDITIONAL DEFECTS WERE NOTED: THE NR 2 CARGO SMOKE DETECTOR FAISDR HNAA2011102700340Connector · dirtyRIGHT AC BUSS CAUTION LIGHT ILLUMINATED ALONG WITH STALL WARNING AND RT TRU CAUTION LIGHT. CHECKED NR 2 ENGINE BRUSH BLOCK AND CLEANED. CHECKED WIRING IN NR 2 NACELLE AND CLEANED CONNECTOR ON AC GENERATOR. CHECKED AC CONTACTOR BOX. NO DEFECTS NOTED. RAN ASDR CA111019016Wire · chafed(CAN) THE NR 1 ENGINE OIL PRESSURE WARNING LIGHT CAME ON DURING ROTATION AND CONTINUED TO FLICKER DURING THE INITIAL CLIMB. THE OIL PRESSURE ON THE GAUGE WAS STEADY AND NORMAL. ONCE THE ACFT HAD CLIMBED TO A SAFE ALTITUDE THE ENGINE WAS SHUTDOWN IAW THE QRH SDR HNAA2011102700339Bulb · burned outROW 1 RED FLOOR EMERGENCY LIGHT IS BURNED OUT. R & R ROW 1 FLOOR EMEERGENCY LIGHT BULB AS REQUIRED. OPS CHECKED GOOD.SDR HNAA2011102700338Smoke Detector · failedDURING TAXI OUT, BAG BAY SMOKE WARNING ILLUMINATED INTERMITTENTLY. F/A CONFIRMED NO SMOKE OR FUMES IN BAG BAY.( BOTH TEST NORMAL). R & R FORWRD NR 2 BAG BAY SMOKE DETECTOR IAW 26-12-01. OPS CHECKED GOOD. OK FOR SERVICE.SDR CA111018006Acm · inoperative(CAN) AFTER ENGINE START, BOTH BLEEDS WERE SELECTED ON AND THE CABIN AND FLIGHT DECK FILLED WITH A SMOKE HAZE. ENGINES WERE SHUTDOWN AND A RAPID DEPLANEMENT WAS CARRIED OUT. AFTER MX T/S WAS CARRIED OUT THE AIR CYCLE MACHINE AND THE HEAT EXCHANGER WERE REPLASDR CA111012004Bearing Race · damaged(CAN) DURING THE ACCOMPLISHMENT OF TASK DH1-61-10-00-RR-801-0, WHEN THE RT PROP HUB WAS REMOVED, IT WAS FOUND THAT THE NR 2 BLADE BEARING RACE INSIDE THE HUB WAS DAMAGED AND CRACKED. THE BEARING, BEARING RETAINER AND BLADE RACE WERE INSPECTED AND NO DAMAGE WASDR CA111011010Acm · seized(CAN) AFTER PUSHBACK THE CREW NOTED A HAZE IN THE CABIN AND A BURNING ODOR. A RAPID DEPLANEMENT WAS CARRIED OUT ON THE RAMP. MX FOUND THE ACM SEIZED. THE ACM WAS REPLACED.SDR CA111024005Fuel Filter · malfunctioned(CAN) HAD SEVERAL OCCURENCES OF FUEL FILTER BY PASS LIGHT COMING ON IN FLIGHT ON OUR -8 ACFT. WE WERE USING PMA, PN 5905587, HP FUEL FILTER, HAVE NOW STOPPED USING THE FILTER AND ARE USING FILTER, PN 3070542-01. HAD NO OCCURENCES ON AN ACFT WITH THE OEM FILSDR CA111004003Actuator · cracked(CAN) THE ACFT LOST ALL OF THEIR NR 1 HYD SYS FLUID IN THE CLIMB, THEY RETURNED TO THE DEPARTURE AIRPORT. MX INVESTIGATION FOUND THAT THE HOUSING OF THE RT INBD ROLL SPOILER ACTUATOR WAS FRACTURED AND WAS THE CAUSE OF THE LOSS OF FLUID. THE ROLL SPOILER ACTUASDR HNAA2011100700Bulb · failedPAX DOOR EMERGENCY EXIT BULB NOT WORKING. R & R PAX DOOR EMERGENCY EXIT BULB AS REQUIRED.SDR HNAA2011100700321Bulb · failed1 AFT AND 1 FORWARD EMERGENCY FLOOR LIGHT IS NOT WORKING. R & R LAMP.SDR HNAA2011101300336Structure · corrodedLIGHT CORROSION AT STA X202 STR 31P. POLISHED AREA, INSPECTED AND FOUND NO CORROSION. ALODINED AND PRIMED IAW AMM 20-34-08.SDR HNAA2011101300335Skin · corrodedRT SIDE COCKPIT UNDERFLOOR AT STA X175 HAS SKIN CORROSION INBD OF STR 32S. CLEANED AND BLENDED AREA IAW SRM 51-20-16 AND 51-20-36. ALODINED AND EPOXY PRIMED AREA.SDR HNAA2011100600318Threshold · corrodedCORROSION UNDER TEFLON STRIP AT PAX DOOR THRESHOLD. BLENDED THRESHOLD ASSY. INSTALLED NEW THRESHOLD ASSY IAW ENG DWG 85321241.SDR HNAA2011100600317Transceiver · failedWEATHER RADAR INOP. NOT PAINTING GROUND OR WEATHER. R & R WEATHER RADAR RT IAW 34-41-04. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2011100600316Battery · overheatedHOT AUX BATTERY LIGHT ILLUMINATED. R & R AUX BATTERY IAW WORK CARD 24-30-12R. OK FOR SERVICE.SDR HNAA2011100600315Bulb · burned outROW 4DF EMERGENCY SIDEWALL LIGHT IS NOT WORKING. REMOVED LENS, R & R BULB, REINSTALLED LENS. OPS CHECKED GOOD.SDR HNAA2011100600314Warning Light · malfunctionedNR 1 AMBER ADVISORY LIGHT ON LT GEAR, STAYS ILLUMINATED FOR APPROX 50 SECONDS AFTER GEAR RETRACTION. ADJUSTED FORWARD NR 1 MLG DOOR MECHANISM IAW MM 32-10-21. CYCLED LANDING GEAR SEVERAL TIMES. NO DEFECTS NOTED AT THIS TIME. OK FOR SERVICE.SDR HNAA2011100600313Line · failedAFTER TAKEOFF, NR 2 HYD SYS WENT TO ISO, NR 2 HYD SYS DROPPED TO 1 QUART. RETURN TO FIELD. NR 2 QUANTY DOWN TO ZERO. R & R NOSE GEAR STAY ACTUATOR HYD LINE. BLED AND SERVICED NR 2 HYD SYS AND LEAKED CHECKED GOOD.SDR HNAA2011100600312Ahrs · failedAHRS DATA INVALID MESSAGE ON TAKEOFF WITH ASSOCIATED FD AND YD FAILURE. (NR 1 AHRS ALREADY ON MEL). R & R NR 2 AHRS COMPUTER IAW MM 34-20-06. OPS CHECKED GOOD.SDR CA110927005Actuator · inoperative(CAN) REF: DEFECT-1013434, LT OTBD ROLL SPOILER WAS NOT MOVING ON THE PFCS AND CONFIRM VISUALLY NOT TO BE MOVING. LP 624597, DURING PRE FLIGHT CHECK, THE LT OTBD SPOILER WAS NOTED AS NOT MOVING ON PFCS AND VISUALLY CONFIRMED. ALL OTHER FLT CONTROLS NORMAL. HSDR HNAA2011101300334Channel · crackedLT INBD SEAT TRACK DRAIN CHANNEL CRACKED AT RIVET HOLE AT STA X226. REMOVED DAMAGED DRAIN CHANNEL SECTION. INSTALLED FABRICATED DRAIN CHANNEL SECTION.SDR HNAA2011101300333Seat Track · corrodedCORROSION AT RT INBD SEAT RAIL AT STA X185.00(IN FRONT OF LAV). REMOVED SECTION OF SEAT RAIL, INSTALLED NEW IAW RD8-53-3074.SDR HNAA2011101300332Seat Track · corrodedCORROSION AT RT INBD SEAT TRACK AT STA.X215.5 THRU X222.7 (IN FRONT OF LAV). FOUND CORROSION TO BE OUT OF LIMITS. REMOVED CORRODED SECTION OF SEAT TRACK, INSTALLED NEW SEAT TRACK ASSY IAW RD8-53-3074.SDR HNAA2011101300330Stop · corrodedAIRSTAIR DOOR BOTTOM STEP AFT L BRACKET IS CORRODED. R & R AIRSTAIR DOOR STOP ASSY IAW AMM 52-10-00.SDR HNAA2011101300329Seat Track · corrodedCORROSION AT LT INBD SEAT TRACK FROM STA X253 THRU X259. REPAIRED IAW RD8-53-4698. COMPLIED WITH HFEC INSPECTION. NO DEFECTS NOTED.SDR HNAA2011101300328Seat Track · corrodedSUSPECT CORROSION AT LT INBD SEAT TRACK, STA X253 UNDER WATER DRAIN BRACKET. MARKED WITH ORANGE MARKER. REPAIRED IAW RD8-53-4698. COMPLIED WITH HFEC INSPECTION. NO DEFECTS NOTED.SDR HNAA201101300327Seat Track · corrodedCORROSION AT LT OTBD SEAT TRACK STA X310. REPAIRED IAW RD8-53-1342. COMPLIED WITH EDDY CURRENT INSP. NO CRACKS NOTED.SDR HNAA20111300326Seat Track · corrodedCORROSION AT LT OTBD SEAT TRACK AT STA X282. REPAIRED IAW RD8-53-2342. COMPLIED WITH EDDY CURRENT INSP. NO CRACKS NOTED.SDR HNAA201113000325Seat Track · corrodedCORROSION AT LT OTBD SEAT TRACK AT STA X290. REPAIRED IAW RD8-53-1342. COMPLIED WITH EDDY CURRENT INSP. NO CRACKS FOUND.SDR HNAA2011100600310Wire · brokenEMERGENCY LIGHT AT ROW 1DF NOT WORKING (3RD 1 FROM FRONT) FOUND BROKEN WIRE SPLICE, R & R WITH NEW SPLICE. OPS CHECKED GOOD.SDR HNAA2011100600309Wire · brokenON TAKEOFF, FLAP HANDLE SELECTED TO ZERO. WOULD NOT RETRACT. STUCK AT 5. FOUND BROKEN WIRE ON FLAP HANDLE ARMING SWITCH, RESOLDERED SAID WIRE IAW AMM 20-45-04. OPS CHECKED GOOD AT THIS TIME.SDR CA110921004Line · leaking(CAN) HYD LEAK FOUND COMING FROM NLG AREA ON WALK AROUND. LEAK FOUND TO BE COMING FROM UP SELECTION TO NLG OVERCENTER ACTUATOR HYD LINE LEAKING EXTERNALLY. HYD LINE REPLACED AND ACFT RETURNED TO SERVICE.SDR HNAA2011100600308Bulb · inoperativeFLOOR EMERGENCY LIGHT NOT WORKING. R & R BULB ON FLOOR EMERGENCY LIGHT. OPS CHECKED GOOD.SDR 3PRA2011091500002Skin · nickedLOWER EXTERNAL SKIN IN ZONE 141 HAS MULTIPLE NICKS AND DENTS. BLENDED HIGH METAL AND LOWER EXTERNAL SKIN IN ZONE 141 ANT DENT/DAMAGE NR147, NR148, AND NR149 TO WITH IN LIMIT CONDITION IAW RD 8-53-11986.SDR 3PRA2011091500001Skin · gougedFUSELAGE SKIN GOUGED IN 2 EA DENTS AT STR 21R AND STA X266. BLENDED DAMAGE TO WITHIN LIMITS.SDR HNAA2011091900293Ecu · failedDURING SHUTDOWN WITH NR1 CONDITION LEVER IN START/FEATHER. NR 1 ENGING TORQUE SURGED TO 90 PERCENT AND PROPELLER RPM STAYED AT 600 FOR 7 SECONDS. ALL OTHER PARAMETERS NORMAL. R & R ECU. PERFORMED RUN UP OPS CHECK IAW MX RUN UP MANUAL FOR COMPONENT CHANGED.SDR HNAA2011091900292Bulb · failedLT AFT EMERGENCY LIGHT DIM. R & R BULB.SDR HNAA2011091900291Lamp · failedEMERGENCY LIGHT ON F/A WALL AT CABIN ENTRANCE HAS 1 INOPERATIVE LAMP. RELAMPED EMERGENCY LIGHT.SDR HNAA2011091900289Selector Panel · failedPRESSURIZATION FAULT LIGHT ON. WILL NOT GO OUT. R & R CABIN PRESSURE SELECTOR PANEL. OPS CHECKED GOOD IAW MM 21-30-07. CLEARED MEL. REVERSED SP21-1 OUTFLOW RETURNED TO ORIGINAL CONFIGURATION.SDR HNAA2011091100280Pump · inoperativeNR 1 STANDBY PRESSURE INDICATES ZERO. R & R RT RCCP. GROUND RUN UP, OPS CHECKED GOOD IAW MM 29-11-17.SDR CA110915007Blade · debonded(CAN) PROPELLER BLADE HEATER ELEMENT BECOMING DISBONDED FROM BLADE AND BUBBLING.SDR CA110915003Union · cracked(CAN) FITTING AN815-10D FOUND COMPLETELY BROKEN INTO 2 PIECES. NO VISUAL EVIDENCE OF LONG TIME CRACK OR CORROSION.SDR HNAA2011091900287Light · malfunctionedEMERGENCY EXIT BETA LIGHTS VERY DIM. R & R LIGHT ON EMERGENCY EXIT USING RETAINING CLIPS.SDR HNAA2011091900285Bulb · burned outF/A EMERGENCY LIGHT SWITCH IS NOT BACK LIGHT. RELAMPED, OPS CHECKED GOOD. OK FOR SERVICE.
Back to Boeing DHC-8-102