Boeing DHC-8-102
Service difficulty reports · 9,272
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2016021900040Battery Pack · inoperativeREAR LEFT EMERGENCY LIGHT IS INOPERATIVE. R & R EMERGENCY LIGHT BATTERY PACK PS3. OPS CHECKED GOOD.SDR CA160224004Jackscrew · malfunctioned(CAN) FLIGHT CREW REPORTED FROZEN ELEVATOR TRIM IN DESCENT. AT 4,000 FT TRIM BEGAN TO MOVE AGAIN. ACFT LANDED WITH NO FURTHER FAULT. SYS INSPECTED WITH NO FAULTS FOUND. TRIM JACKS LUBRICATED. IT WAS NOTED THAT SINCE MFG REMOVED THE LOW UTILIZATION MAINTENANSDR HNAA2016021700039Bulb · inoperativeFLOOR EMERGENCY LIGHT IS INOPERATIVE AT ROW 7DF. R & R THE BULB. OPS CHECKED GOOD.SDR HNAA2016021700038Bulb · inoperativeRED FLOOR EMERGENCY LIGHT IS INOPERATIVE AT ROW 1DF. R & R THE BULB. OPS CHECKED GOOD.SDR HNAA2016021700036Valve · inoperativeRT OUTER DEICE BOOT DOES NOT INDICATE INFLATION AND DOES NOT INFLATE IN MANUAL OR AUTO. NR 4 RT OTBD DISTRIBUTOR VALVE AND OTBD PRESSURE SWITCH IAW MM 30-10-16 AND PB 30-3. OPS CHECKED GOOD.SDR HNAA2016021700035Switch · malfunctionedLT ELEVATOR HORN HEAT CAUTION LIGHT ILLUMINATED WITH NO LOADS. SWAPPED ELEVATOR HORN HEAT SWITCH 3015-S4 AND 3015-S5 TO ALTERNATE POSITION. GROUND RAN ACFT WITH CREW. OPS CHECKED GOOD IAW SRT MANUAL.SDR HNAA2016021500034Bulb · inoperativeRED FLOOR EMERGENCY LIGHT IS INOPERATIVE AT ROW 7DF. R & R BULB. OPS CHECKED GOOD.SDR CA160211006Brake · seized(CAN) THE CREW REPORTED SMOKE COMING FROM RT MAIN LANDING GEAR DURING TAXI IN AND INCREASED AT GATE. MAINTENANCE FOUND THE NR 4 BRAKE ASSEMBLY SEIZED AND LEAKING HYDRAULIC FLUID. ASSEMBLY REPLACED.SDR HNAA2016020300030Battery Pack · inoperativeFORWARD EGRESS AND PASSENGER DOOR EMERGENCY LIGHTS ARE OUT. R & R EMERGENCY LIGHT BATTERY PS1 IAW MM 33-51-00. OPS CHECKED GOOD.SDR HNAA2016020100027Bulb · inoperativeFLOOR EMERGENCY LIGHT IS OUT AT ROW 6DF. R & R BULBS AT ROW 6DF. OPS CHECKED GOOD.SDR HNAA2016012900026Autofeather Sys · malfunctionedAUTOFEATHER WILL NOT ARM ON TAKEOFF ROLL. AUTO FEATHER SELECT SWITCH WENT BLANK. K5 CIRCUIT BREAKER TRIPPED. RESET CIRCUIT BREAKER K5 ENGINE TORQUE CONDITION. CLEANED CONNECTOR ON NR 2 ENGINE TSCU. GROUND RAN ACFT. AUTOFEATHER TEST FAILED. NO FIX. SLAVED SDR HNAA2016012700025Bulb · inoperativeEMERGENCY LIGHT IS OUT AT ROW 7. R & R BULBS. OPS CHECKED GOOD.SDR HNAA2016012700024Bulb · inoperativeEMERGENCY FLOOR LIGHT IS OUT AT ROW 2. R & R BULBS AT ROW 2. OPS CHECKED GOOD.SDR HNAA2016012700023Circuit Breaker · trippedIN FLIGHT, NR 2 TORQUE INDICATOR CIRCUIT BREAKER TRIPPED. REMOVED CONNECTOR FROM NR 2 TSCU. CLEANED, INSPECTED AND REINSTALLED CONNECTOR . RESET CIRCUIT BREAKER K-5. GROUND RAN ACFT. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2016012700022Control Unit · malfunctionedAUTOFEATHER WOULD NOT ARM DURING TAKEOFF ROLL. R & R NR 2 TSCU. RAN AIRCRAFT. OPS CHECKED GOOD IAW MM 72-01-10.SDR CA160129006Bearing · seized(CAN) FWD MLG DOOR ACTUATOR ROLLER BEARING FOUND DETERIORATED, SEIZED CAUSING GEAR DOOR MECHANISM TO JAM AND DRAG STRUT FAIRING TO CONTACT MLG DOOR HINGE. DAMAGE DETECTED ON FWD MLG DOOR ATTACH ROD. RT FWD MLG DOOR ACTUATOR MECHANISM REPLACED. RD 8-51-256 OPSDR HNAA2015012500020Bulb · inoperativeEMERGENCY FLOOR LIGHT IS INOPERATIVE AT ROW 1. R & R BULB AT ROW 1 EMERGENCY FLOOR LIGHT. OPS CHECKED GOOD.SDR HNAA2016012200016Wire · brokenAUTOFEATHER WILL NOT ARM. FOUND BROKEN WIRE AT NR 1 ENGINE POWER LEVER MICROSWITCH TERMINAL. RESOLDERED WIRE TERMINAL, PERFORMED OPS CHECKED. OPS CHECK GOOD. COMPLIED WITH ENGINE RUNS IAW SR MANUAL. OPS CHECKED GOOD.SDR HNAA2016012000012Sequence Valve · malfunctionedILLUMINATION OF 2 MLG DOOR LIGHTS AND ILLUMINATION OF RED GEAR. R & R PSEU AND NOSE GEAR SOLENOID SEQUENCE VALVE. OPS AND LEAKED CHECKED GOOD IAW 32-30-00.SDR HNAA2016011800011Bulb · inoperativeEMERGENCY OVERHEAD LIGHT IS INOPERATIVE. R & R BULBS IN OVERHEAD EMERGENCY LIGHT . OPS CHECKED GOOD.SDR HNAA2016011800010Control Box · malfunctionedPASSENGER EMERGENCY LIGHTS FLICKERED DIMLY DURING CLIMB OUT WITH PROP DEICE OFF, BUFFER LIGHT FLUCTUATING AT THE SAME TIME. R & R EMERGENCY LIGHT CONTROL BOX IAW MM 33-51-11. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2016011800009Actuator · warning lightNOSE GEAR DOOR AMBER LIGHT REMAINED ILLUMINATED AFTER GEAR RETRACTION. EXTENDED LANDING GEAR AND LIGHT REMAINED ON. R & R NOSE GEAR DOOR ACTUATOR IAW 32-20-26. SWUNG GEAR SEVERAL TIMES. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2016011500008Bulb · inoperativeEMERGENCY FLOOR LIGHT INOPERATIVE AT ROW 8. R & R BULBS. OPS CHECKED GOOD.SDR HNAA2016011500007Brush Block · dirtyCABIN EMERGENCY LIGHTS FLICKERED IN FLIGHT WITH PROP DE-ICE SELECTED. INSPECTED AND CLEANED BRUSH BLOCKS ASSY ON NR 1 AND NR 2 ENGINES. R & R EMERGENCY CONTROL BOX. RAN ACFT AND CHECKED PROP HEAT. NO DISCREPANCIES NOTED. OK FOR SERVICE.SDR HNAA2016011500006Inverter · odorFISH ODOR STRONG IN GALLEY AREA. R & R PRIMARY INVERTER IAW 24-22-00. OPS CHECKED GOOD.SDR CA160122003Pulley Bracket · cracked(CAN) DURING MAINTENANCE AND ADJUSTMENT OF THE ALTERNATE GEAR RELEASE SYS, THE PULLEY BRACKET IN THE LT NACELLE, FOR THE SYS CABLE, WAS FOUND CRACKED. PULLEY BRACKET REPLACED AND SYS TESTED SERVICEABLE. ACFT HRS: 60205, ACFT CYCLES: 61435.SDR CA160118017Servo · stuck(CAN) ROLL CONTROL SERVO STUCK IN, ON POSITION, IN-FLIGHT. THIS MADE ROLL CONTROL DIFFICULT. MAINTENANCE ACTIONS: AILERON SERVO DISABLED. CIRCUIT BREAKER PULLED. STANDBY ELEVATOR TRIM SYS, CONFIRMED OPERATIVE. BECAUSE THE SYSTEM WAS CONFIRMED OPERATIVE THE FSDR CA160112005B-Nut · loose(CAN) THE CREW EXPERIENCED A LOSS OF NR 2 HYDR, INFLIGHT, AN EMERGENCY WAS DECLARED AND AN ALTERNATE GEAR EXTENSION PERFORMED. MAINTENANCE DISCOVERED THE NR 2 EDP "B-NUT" PRESSURE LINE LOOSE. DURING THE SUBSEQUENT INSPECTION, THE SUCTION LINE AND RETURN LINSDR CA160111003Frame · corroded(CAN) DURING COMPLETION OF TASK 144-DH1, GVI OF BAGGAGE COMPARTMENT UNDERFLOOR, CORROSION FOUND ON THE AFT CARGO DOOR FRAME JUST ABOVE THE DOOR SILL AT STN X600. REPAIRED IAW REPAIR RD-53-14488.SDR HNAA2016010400005Bulb · burned outFLOOR EMERGENCY LIGHTS IN CABIN 9TH FROM FRONT INOPERATIVE. R & R EMERGENCY LIGHT FLOOR PATH LIGHT BULB AND RESECURED LIGHT COVER.SDR HNAA2016010400003Lamp · burned outEMERGENCY EXIT SIGN ON LOWER FWD OF PAX DOOR HAS INOPERATIVE LAMP. R & R LAMP AND REINSTALLED LENS COVER.SDR HNAA2016010400002Battery Pack · dischargedEMERGENCY LIGHT SWITCH ON F/A PANEL WAS LEFT ON AND EMERGENCY LIGHTS ARE INOPERATIVE AT THIS TIME. REPLACED DEFECTIVE BATTERY AT 3351-PS4 AND 3351-PS2. EMERGENCY LIGHTS SYSTEM OPERATIONAL CHECK SATISFACTORY, REF MM 33-52-00.SDR HNAA2016010400001Tru · malfunctionedDURING CRUISE, RT AC BUSS CAUTION LIGHT ILLUMINATED. FOLLOWING C/L'S ILL. R TRU, R ELEVATOR HORN HEAT, AND RT STALL WARNING, MAINTENANCE GROUND RAN ACFT.SDR HNAA2016010400000Brush Block · contaminatedFLOOR EMERGENCY LIGHTS FLICKER INTERMITTENTLY WITH PROP HEAT ON. INSPECTED 1 AND 2 PROP BRUSH BLOCKS, FOUND TO BE WET WITH DEICE FLUID. CLEANED AS REQUIRED. NO DEFECTS FOUND AT THIS TIME. GROUND RAN BOTH ENGINES FOR 25 MINUTES, OPS NORMAL IAW RUNUP MANUAL, OSDR HNAA2015123000377Selector Switch · inoperativeDURING AUTOFEATHER TEST, NR 2 PROP WILL NOT FEATHER. RPM DROPS FROM 650 TO 590. ALL OTHER PARAMETERS OK. R & R RELAYS 6121-K4, K2 AND K10. SLAVED IN NR 2 TSEU, NO FIX. ORIGINAL TSEU REINSTALLED. R & R NR 2 PCU IAW 61-10-10R. NO FIX. R & R AUTOFEATHER SELSDR HNAA2015122800376Bulb · inoperativeEMERGENCY LIGHT ON FORWARD RT SIDE OF FUSELAGE IS INOPERATIVE. R & R BULB FOR RT FORWARD EGRESS LIGHT IAW MM 33-51-05. OPS CHECKED GOOD.SDR HNAA2015122800375Controller · malfunctionedF/O WINDSCREEN HAD PUFF OF SMOKE FROM TRIM ABOVE TERMINAL BLOCK WHEN WINDSCREEN HEAT WAS SELECTED TO WARM UP. R & R F/O WINDSCREEN IAW WC 56-00-00R. R & R F/O WINDSCREEN CONTROLLER IAW MM 30-41-99. OPS AND LEAKED CHECKED GOOD.SDR HNAA2015122800374Computer · out of adjustUNCOMMANDED STICK SHAKERS ON DURING ROTATION. RETURNED TO FIELD. SHAKERS STOPPED WHEN ACFT ON THE GROUND. FOUND NR 1 STALL WARNING COMPUTER SLIGHTLY OUT OF ADJUSTMENT. CALIBRATED NR 1 AND NR 2 STALL WARNING COMPUTER. OPS AND FUNCTION CHECKED GOOD IAW MM 2SDR HNAA2015122500372Bulb · inoperativeEMERGENCY FLOOR LIGHT IS INOPERATIVE AT ROW 2. REMOVED FLOOR TRIM, R & R BULBS. REINSTALLED TRIM, OPS CHECKED GOOD.SDR HNAA2015122500370Bulb · dimDIM AT EMERGENCY LIGHT ON, LT OF FUSELAGE. R & R BULB. OPS CHECKED GOOD.SDR HNAA2015122100369Brush Block · shortedEMERGENCY LIGHTS FLICKERED AND CYCLED ON/OFF WITH PROP HEAT ON AND PROPS AT 1050. GOOD WITH PROP HEAT OFF. INSPECTED NR 2 PROP, A PHASE SLIP RINGS AND LEADS. NO DEFECTS NOTED. R & R NR 2 BRUSH BLOCK. GROUND RAN. OPS CHECKED NORMAL AT THIS TIME.SDR HNAA2015122100368Socket · burnedSTRONG ELECTRICAL ODOR COMING FROM THE WARDROBE CLOSET. NO VISUAL EVIDENCE. FOUND OVERHEAD, MOST FORWARD LT BULB SOCKET BURNED. PULLED AND COLLARD CIRCUIT BREAKERS SI, S2 AND R2. DEACTIVATED IAW SP 33.1 MEL.SDR HNAA2015121600366Bulb · burned outBULBS BURNED AT EMERGENCY EXIT OVERHEAD PANEL. R & R BULBS AT EMERGENCY OVERHEAD PANEL. OPS CHECKED GOOD.SDR HNAA2015120900365Bulb · inoperative5TH EMERGENCY LIGHT IS INOPERATIVE. R & R BULBS, OPS CHECKED GOOD.SDR HNAA2015120900364Bulb · inoperativeEMERGENCY FLOOR LIGHT IS INOPERATIVE AT ROW 7. R & R BULBS. OPS CHECKED GOOD.SDR HNAA2015120700363Bulb · inoperativeCABIN FLOOR EMERGENCY LIGHT IS INOPERATIVE, 6TH FROM FRONT. R & R BULBS FOR EMERGENCY LIGHT. OPS CHECKED GOOD.SDR HNAA2015120700362Bulb · inoperativeEMERGENCY LIGHT IS INOPERATIVE AT ROW 1. R & R BULBS AT ROW 1 EMERGENCY LIGHT. OPS CHECKED GOOD.SDR HNAA2015120700361Bulb · dimLEFT FORWARD EMERGENCY EGRESS LIGHT IS DIM. R & R BULB AT LT EMERGENCY EGRESS LIGHT. OPS CHECKED GOOD.SDR HNAA2015120700360Wire · brokenEMERGENCY LIGHT IS INOPERATIVE AT ROW 8DF. REPAIRED EMERGENCY FLOOR PATH LIGHT WITH NEW WIRE SPLICE IAW MM 20-45-07. OPS CHECKED GOOD.SDR HNAA2015120700359Terminal · looseCAPTAINS FORWARD WINDSCREEN HAS SMOKE AT DEICE CONTACTORS. INSPECTED CAPTAIN'S WINDSCREEN HEAT WIRES AT TERMINAL B. FOUND TERMINALS TO BE LOOSE WITH NO ARC DAMAGE. RE-TIGHTENED TERMINALS L1 AND L2. GROUND RAN ACFT WITH CREW. LOADS NORMAL. SYSTEM OPS CHECKE
Back to Boeing DHC-8-102