Douglas DC-8-71F
Service difficulty reports · 8,938
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA003236Intercostal · crackedDURING A MAINTENANCE VISIT FOUND AN INTERCOSTAL STRAP BROKEN LT SIDE OF CENTER TRACK AT STA 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003235Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN INTERCOSTAL STRAP RT SIDE OF CENTER TRACK AT STA 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003234Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND A LARGE HOLE TO THE LT SIDE OF CABIN FLOOR WEB AT STA 120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003233Floorbeam · damagedDURING A MAINTENANCE VISIT FOUND A TEAR IN THE CABIN FLOORBOARD FRAME AT STA 1680, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003232Skin · dentedDURING A MAINTENANCE VISIT FOUND A DENT TO THE RT FWD O/W EXIT DOOR IN EDGE OF OUTER SKIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003231Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO LIGHTENING HOLE ON THE FRAME WEB AT FS 1372, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003230Frame · tool damageDURING A MAINTENANCE VISIT FOUND DRILL MARKS ON FRAME TOP FWD CORNER OF CARGO DOOR AT STA 120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003229Frame · damagedDURING A MAINTENANCE VISIT FOUND A HOLE IN THE FUSELAGE FRAME FOR ACCESS DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003228Bracket · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE BRACKET ON THE VERT STIFFENERS AT STA 680 RBL -24 Z AXIS -2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003227Strap · brokenDURING A MAINTENANCE VISIT FOUND A BROKEN T/E STRAP ON FRAME AT STA 360 AND L13R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003226Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FRAME AT STA 360 ABOVE LONGERON 36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR UPS00834222Actuator · inoperativeINSPECTION TYPE:N/A, ABORTED TAKEOFF DUE TO LIMITED RUDDER MOVEMENT. REMOVED RUDDER HYD PACKAGE PER MM 27-21-06. INSTALLED RUDDER HYD PACKAGE STEPS 1-21 MM 27-21-06 LEAK AND OPS CHECKS OK. ACCOMPLISHED RUDDER ADJ TEST IAW 27-20-00, OPS CHECKS GOOD.SDR UPS00834417Frame · corrodedINSPECTION TYPE:C2, AFT CARGO COMPT FS 1100 FRAME CORRODED AROUND FASTENERS AT LONGERON 35 RT. REMOVED CORROSION FOUND OUT OF LIMITS. FAB REPAIR ANGLE IAW EO 5310-117 28 REV A. REMOVED INTERCOSTAL AND GUSSET STA 1100 - 1120 L35 RT, ALODINED AND PRIMED IAW DSDR UPS00834413Longeron · corrodedINSPECTION TYPE:C2, CORROSION ON I/B AND O/B LEGS OF LONGERON 36 IN AREA AROUND FWD DME ANTENNA BETWEEN FS 8 & 25. REMOVED FWD DME ANTENNA AND SEPARATED WIRE BUNDLE FROM TEMP CONTROLLER AND HOUSING TO FOM. REMOVED SHOVEL FITTING, FOUND OUT OF LIMITS IAW DC8 SDR UPS00834209Packing · failedINSPECTION TYPE:N/A, AFTER TAKEOFF FLAPS STOPPED AT 10 DEG, HYDRAULIC PRESSURE DECREASED TO 0 PSI, AND HYDRAULIC QUANTITY DEPLEATED TO EMERGENCY AUX LEVEL. CREW RAN RES LOW PRESS LIGHT CHECKLIST AND LOSS OF HYDRAULIC PRESSURE EMERGENCY CHECKLIST. FOUND LT AISDR UPS00834315Attach Angle · corrodedINSPECTION TYPE:C2, AFT PIT SMOKE BARRIER CEILING ATTACH ANGLE CORRODED. REMOVED CORRODED ANGLE, FABED NEW ANGLE IAW TIMCO DWG DWG-01252. ALODINED AND PRIMED INSTALLED ANGLE IAW 51-3-0.SDR UPS00834314Frame · corrodedINSPECTION TYPE:C2, AFT CARGO COMPT FS 1100 FRAME CORRODED AROUND FASTENERS AT LONG 35 RT. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. FAB REPAIR ANGLE FILLER IAW UPS EO 5310-11728, REMOVED INTERCOSTAL AND GUSSET STA 1100 - 1120, ALODINED AND PRIMED INSTALSDR UPS00834309Fitting · crackedINSPECTION TYPE:C2, AFT CARGO COMPT FS 1055 - 1060 L35R SPLICE CRACKED. REMOVED INTERCOSTAL, 2 L-ANGLES TO GAIN ACCESS TO LONG SPLICE FITTING IAW DC8 SRM 51-1-20D. LOCATED AND DRILLED NEW FITTING IAW DC8 SRM 51-1 -24. INSTALLED INTERCOSTAL FITTING AND 2 L-ASDR RRXA003247Stringer Clip · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CLIP AT THE LT CENTER WING THRU ACCESS HOLE 516 THRU MID SPAR ACCESS HOLE 560E AT STA XCW +46 BETWEEN STRINGER 72 - 73, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003246Stringer Clip · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CLIP AT THE LT CENTER WING THRU ACCESS HOLE 516 THRU MID SPAR ACCESS HOLE 560E AT STA XCW +46 BETWEEN STRINGER 73 - 74, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003245Stringer Clip · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT LWR CLIP LT CENTER WING THRU ACCESS HOLE 516 THRU MID SPAR ACCESS HOLE 560E AT STA XCW +23 & SCW +46 BETWEEN STR 73 - 74, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003244Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL STRAP BETWEEN CENTER SEAT TRACK AND 2ND FROM O/B TRACK AT STA 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003243Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL STRAP BELOW 3RD FROM O/B TRACK AT STA 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003242Seat Track · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE 3RD TRACK FROM RIGHT O/B SIDE BETWEEN STA''S 859 & 879, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003241Seat Track · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE CENTER SEAT TRACK FRAME AT STA 70, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003240Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE PRESSURE BULKHEAD TIE IN FITTING IN THE RT MAIN WHEEL WELL FWD UPPER I/B CORNER AT STA 8576.125 X-3 Z-10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003838Plate · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R1 SERVICE DOOR SCUFF PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW EO 00-257 WITH APPROVED 8110-3 DATED 09/26/00.SDR RRXA003836Clip · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO STRINGER CLIP AT STA. XW485 AND BETWEEN STRINGER 62-63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW SDR RRXA003255Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN INTERCOSTAL STRAP LT SIDE OF CENTER SEAT TRACK AT STA 660 AT X=+5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1SDR RRXA003254Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN INTERCOSTAL STRAP LT SIDE OF CENTER SEAT TRACK AT STA 620 AT X=+3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-SDR RRXA003253Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN INTERCOSTAL STRAP LT SIDE OF CENTER SEAT TRACK AT STA 560 AND X=+3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-SDR UPS00834419Frame · crackedINSPECTION TYPE:C2, MAIN CABIN FS 1575 FRAME CRACKED JUST ABOVE LT CUSP. REPAIRED FRAME IAW REO G07671.SDR UPS00834313Gusset · corrodedINSPECTION TYPE:C2, CORROSION AROUND FASTENERS IN GUSSET ON LOWER LEG OF FLOOR FRAME AT FS 1340 APROX 20 INCHES I/B OF RIGHT CUSP. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC8 SRM 53-2-0. REMOVED GUSSET, FAB NEW IAW DAC DWG 9754034, ALODINE AND PRIME SDR UPS00834312Gusset · corrodedINSPECTION TYPE:C2, CORROSION AROUND FASTENERS IN GUSSET ON LOWER LEG OF FLOOR FRAME AT FS 1320 APPROX 20 INCHES I/B OF THE RIGHT CUSP. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC8 SRM 53-2-0. REMOVED GUSSET, FAB NEW GUSSET IAW DAC DWG 9754034, ALODINSDR UPS00834311Fitting · crackedINSPECTION TYPE:C2, AFT CARGO COMPT CROSSLIDE DOOR 2 LOWER ''T'' BOLT FITTING CRACKED. REMOVED 2 T-BOLT FITTINGS IAW DC8 SRM 51-1-20D, LOCATED AND DRILLED 2 NEW FITTINGS IAW DC8 SRM 51-1-24, INSTALLED 2 FITTINGS IAW DC8 SRM 51-1-20D.SDR UPS00834307Fitting · crackedINSPECTION TYPE:C2, AFT CARGO COMPT FS 1160 LONGERON 34RT ATTACH FITTING CRACKED AT LOWER FASTENER HOLE. REMOVED CRACKED FITTING, RECVD NEW FITTING (P/N 3755843-502N) MAT ID FOR REPAIR ANGLE 60-436 EXTRUSION .125 7075-T6 511 IAW DC8 SRM 53-2-0. LOCATED AND DSDR RRXA003288Pin · crackedDURING A MAINTENANCE VISIT FOUND THAT THE LT MLG RETRACT PIN NEEDS TO BE REPLACED, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003287Pin · crackedDURING A MAINTENANCE VISIT FOUND THAT THE RT MLG RETRACT PIN NEEDED TO BE REPLACED, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003257Panel · tornDURING A MAINTENANCE VISIT FOUND A TEAR TO THE RT CUSP LINE AT STA 182 - 202, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003256Panel · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN CUST LINE PANEL AT STA 1340 - 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003252Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN INTERCOSTAL STRAP LT SIDE OF CENTER SEAT TRACK AT STA 500 X=+3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003251Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN INTERCOSTAL STRAP LT SIDE OF CENTER SEAT TRACK AT STA 460 AND X=+3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003250Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN INTERCOSTAL STRAP RT SIDE OF CENTER SEAT TRACK AT STA 460 AND X+=3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003249Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN INTERCOSTAL STRAP LT SIDE OF CENTER SEAT TRACK AT STA 420 AND X+=3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003248Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A BROKEN INTERCOSTAL STRAP AT STA 420 AND X+=3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA001069Gyro · failedCO PILOTS ATT GYRO INOP ATTITUDE. FOUND SIX DEGREE SPILT BETWEEN PILOTS AND CO-PILOTS HSI. REMOVED AND REPLACED VG IAW DC-8 M/M 34-25-1. CHECK GOOD. REMOVED AND REPLACED DG IAW DC-8 M/M 34-21-1. OPS CHECK GOOD.SDR RRXA003262Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL FITTING ON BACKSIDE LT AT STA 834 AND L13L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA003261Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK INSIDE DOOR ON UPPER ANGLE LT TYPE 1 DOOR AT STA 120 AND L14L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 52-2-0, 5SDR RRXA003260Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK INSIDE DOOR ON UPPER ANGLE ON THE LT TYPE 1 DOOR AT STA 1320 AND L14L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 5SDR FWT2001F00000Engine · failedENGINE NR 4 SHUTDOWN DURING FLT. DUE TO LOSS OF OIL QUANITY AND PRESSURE. AFTER LANDING, MAINT FOUND TRANSFER GEARBOX MOTORING PAD COVER AND SPLINE-SHAFT IN COWLING, ALL CHIP DETECTORS INSPECTED AND FOUND TRANSFER GEARBOX SCAVENGE IN AND SUPPLY OIL FILTER AN
Back to Douglas DC-8-71F