Douglas DC-9-32
Service difficulty reports · 12,755
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MWEA00686Web · dentedMKE - GALLEY SUBFLOOR AT STATION 220 BETWEEN THE NR 4 SEAT TRACK AND THE OUTBOARD WALL IS DENTED. FABRICATED AND INSTALLED REPAIR DOUBLER. (M)SDR MWEA00685Angle · gougedMKE - FORWARD CARGO DOOR JAMB, FOUR MODERATE GOUGES IN DOOR SEAL DEPRESSOR, FORWARD SIDE, NEAR DOOR SWITCH. FABRICATED AND INSTALLED REPAIR ANGLE. (M)SDR MWEA00684Channel · crackedMKE - FLOOR CHANNEL CRACKED WHERE IT ATTACHES TO FRAME AT STATION 617. FABRICATED AND INSTALLED REPAIR ANGLES. (M)SDR MWEA00683Floor Support · corrodedMKE - GALLEY FLOORBOARD BRACE 18 INCHES INBOARD OF GALLEY DOOR HAS LIGHT CORROSION AROUND ALL THE FASTENER HOLES, BS 180-200. REMOVED AND REPLACED FLOORBOARD BRACE. (M)SDR MWEA00682Floorboard · chafedMKE - CABIN FLOORBOARD E-7 HAS CHAF DAMAGE ON UPPER AND LOWER SURFACES AT ATTACH HOLES. FABRICATED AND INSTALLED FLOORBOARD REPAIR. (M)SDR MWEA00681Floorboard · crackedMKE - CABIN FLOORBOARD E-3 HAS SMALL CRACKED AT EDGE OF SKIN. FABRICATED AND INSTALLED REPAIR DOUBLER. (M)SDR MWEA00680Web · chafedMKE - FORWARD CABIN SUBFLOOR WEB AT STATION 218 HAS AREAS THAT ARE CHAFED AND HAVE LIGHT CORROSION. FABRICATED AND INSTALLED REPAIR DOUBLER. (M)SDR MWEA00679Floorboard · corrodedMKE - CABIN FLOORBOARD B-1 UPPER SURFACE HAS LIGHT CORROSION AND CHAFED AREAS AROUND FASTENER HOLES. FABRICATED AND INSTALLED WEB AND DOUBLER REPAIR. (M)SDR MWEA00678Floorboard · chafedMKE - CABIN FLOORBOARD B-4 ATTACH HOLES HAVE CHAFED DAMAGE. FABRICATED AND INSTALLED FLOOR SKIN AND SPLICE DOUBLER. (M)SDR MWEA00690Shear Tie · damagedMKE - SHEAR TIE HAS OBLONG HOLES FROM LONGERON 10 LEFT TO 16 LEFT AT STATION 945. REMOVED AND REPLACED SHEAR TIE. (M)SDR MWEA00691Floor Panel · damagedMKE - HOLE ON UPPER SURFACE OF CABIN FLOOR PANEL A-1 AT STATION 230. FABRICATED AND INSTALLED FLOOR PANEL REPAIR. (M)SDR MWEA00692Floor Panel · crackedMKE - CABIN FLOOR PANEL F-2 IS CRACKED ON TOP SIDE NEXT TO SCREW HOLE. FABRICATED AND INSTALLED FLOOR PANEL REPAIR. (M)SDR TWAA0013107Floor Support · corrodedDURING OP 15 MAINT CHECK, THE FWD ENTRY FLOORING ATTACH ANGLE AT STA 180 TO 200, LBL 44 INCHES, WAS CORRODED. REMOVED CORRODED FLOOR ATTACH ANGLE. MANUFACTURED AND INSTALLED NEW FLOOR SUPPORT ANGLE FROM 7075-T6 PER DOUGLAS PRINT 9923484.SDR CA000918003Fan · failed(CAN) BURNING SMELL ON PRE-DEPARTURE COMING FROM THE ELECTRICAL EQUIPMENT COMPARTMENT. FOUND THE A/C BUS CONTROL PANEL CIRCUIT BREAKER POPPED, UNABLE TO RESET. REPLACED THE RADIO RACK COOLING FAN AND ALSO THE A/C BUS CONTROL PANEL.SDR AT0000375Light · inoperativeFOUND AFT EMERGENCY LIGHTING AT AFT ENTRY DOOR WILL NOT ILLUMINATE. REPAIRED WIRE IN GROUND TO AFT EMERGENCY LIGHT IAW DC9 WDM 33-51.SDR AT0000374Smoke · detectedFOUND SMOKE IN COCKPIT. AIRCRAFT OUT OF SERVICE, FURTHER EVALUATION AND TROUBLE SHOOTING REQUIRED.SDR ABXA000366Indicator · intermittentON LOWERING THE LANDING GEAR, THE NOSE LANDING GEAR DID NOT INDICATE DOWN AND LOCKED. RECYCLED GEAR, NOSE GEAR INDICATED DOWN AND LOCKED. REPLACED NOSE LANDING GEAR INDICATOR BULBS, CLEANED CANNON PLUG TO NOSE GEAR DOWNLOCK SWITCH. GEAR OPS CHECKED NORMAL.SDR AT0000360Recorder · malfunctionedDURING A SCHEDULED INSPECTION , FOUND DIGITAL FLIGHT RECORDER 18 PARAMETER CORRECATION. COMPLIED WITH EO 9-3130-29-E1495 IR 18 PARAMETER CORRECATION.SDR TWAA0012402Socket · failedBURNING ODOR REPORTED IN AREA OF OVERWING EXITS DURING CRUISE FLIGHT. DEACTIVATED EMERGENCY LIGHTS AND FERRIED AIRCRAFT TO STL FOR CORRECTIONS. FOUND AND REPLACED BURNED LOWER SIDEWALL LIGHT SOCKET AT ROW 15 LEFT SIDE OF CABIN. REPLACED LIGHT BALLAST AND EMSDR MWEA00647Skin · crackedOMA - FLT 270 - DURING TRANSIT CHECK, FOUND HALF INCH CRACK AT FS 360 7 INCHES TO THE RIGHT OF BOTTOM CENTER LINE. INSTALLED TEMPORARY REPAIR IAW SRM 53-04 FIG 38A, PLACED ON CARRYOVER. (M)SDR AT0000380Ejector · malfunctionedDURING A SCHEDULED INSPECTION , FOUND TAIL CONE EMERGENCY INTERNAL RELEASE SYSTEM PROVISIONS. COMPLIED WITH AD 97-22-05A PER EO 12-5350-29-B1358 REV C.SDR TWAA0013106Shear Tie · crackedDURING OP 15 MAINT CHECK, FORMER FOOT WAS CRACKED AT STA 945, LONGERON 15L. INSTALLED NEW FRAME PER MO 72J14 PHASE G.SDR ABXA000390Vane · delaminatedOUTBOARD FIXED VANE DELAMINATED ON TOP SIDE. REPLACED OUTBOARD FIXED VANE.SDR ABXA000389Shear Tie · crackedSHEAR CLIP CRACKED AT STATION 111.000 AND REAR SPAR STRINGER 11. REPLACED SHEAR CLIPIAW DC9 SRM 51-30-5.SDR AT0000377Fuse · inoperativeFOUND EMERGENCY PATH LIGHTS AT SECTION 6 INOPERATIVE. REPLACED FUSE AT BS 980 EMERGENCY PATH LIGHT BATTERY CHARGER POWER SUPPLY IAW MM 33-50.SDR MWEA001317Channel · corrodedMKE - FLOOR PANEL SUPPORT CHANNEL CORRODED ON TOP FLANGE AT STATION 200, FROM CENTERLINE TO RIGHT BODY LINE 20. REMOVED AND REPLACED FLOOR SUPPORT CHANNEL. (M)SDR MWEA00598Frame · damagedMKE - FOUND STATION 313 FRAME HAS 2 NICKS ABOVE LONGERON 15 RIGHT. FABRICATED AND INSTALLED NEW FRAME SEGMENT. (M)SDR MWEA00597Splice · gougedMKE - FRAME SPLICE RIGHT SIDE AT STATION 832 AND LONGERON 18 RIGHT GOUGED. REMOVED AND REPLACED FRAME SPLICE FITTING. (M)SDR MWEA00596Floor Support · corrodedMKE - FOUND FLOOR PANEL SUPPORT CHANNEL CORRODED ON TOP FLANGE LOCATED AT STATION 200, RIGHT BODY LINE 24 TO RIGHT BODY LINE 43. REMOVED AND REPLACED FLOOR SUPPORT CHANNEL. (M)SDR MWEA00595Floor Support · corrodedMKE - FOUND FLOOR PANEL SUPPORT CHANNEL CORRODED ON TOP FLANGE LOCATED AT STATION 200 RIGHT BODY LINE 46 TO RIGHT BODY LINE 57. REMOVED AND REPLACED FLOOR SUPPORT CHANNEL. (M)SDR MWEA00593Fitting · gougedMKE - FRAME SPLICE RIGHT SIDE AT STATION 851 AND LONGERON 18 RIGHT GOUGED. REMOVED AND REPLACED NEW END FITTING. (M)SDR MWEA00591Intercostal · crackedMKE - SMALL CRACK OUT OF FASTENER HOLE, INTERCOSTAL AT STATION 1059 LONGERON 15 RIGHT. FABRICATED AND INSTALLED REPAIR DOUBLERS. (M)SDR MWEA00590Attach Angle · gougedMKE - THE LOWER RIGHT INBOARD PYLON ATTACH ANGLE IS GOUGED AT STATION 990. FABRICATED AND INSTALLED DOUBLER REPAIR. (M)SDR MWEA00608Stiffener · gougedMKE - FORWARD AUXILLARY TANK AFT SIDE LEFT OUTBOARD VERTICAL STIFFENER HAS VERY DEEP GOUGE AT UPPER INBOARD LEG. REMOVED AND REPLACED VERTICAL STIFFENER EXTRUSION. (M)SDR MWEA00607Splice · gougedMKE - FOUND FRAME SPLICE AT STATION 775 AT LONGERON 18 RIGHT IS GOUGED. REMOVED AND REPLACED FRAME SPLICE. (M)SDR MWEA00606Floorboard · corrodedMKE - FOUND FLOORBOARD AFT OF FIRST OFFICERS SEAT HAS HEAVY CORROSION AT STATION 150. REMOVED AND REPLACED FLOORBOARD. (M)SDR MWEA00605Stiffener · chafedMKE - FLOORBOARD C-7 HAS CHAFED DAMAGE TO STIFFENER AT STATION 579 TO 680. FABRICATED AND INSTALLED REPAIR STIFFENER. (M)SDR MWEA00604Stiffener · chafedMKE - FLOORBOARD C-7 HAS CHAFED DAMAGE TO STIFFENER AT STATION 579-620. REMOVED AND REPLACED STIFFENER. (M)SDR MWEA00603Attach Angle · crackedMKE - RIGHT UPPER PYLON ATTACH ANGLE IS CRACKED AT THE FORWARD END. FABRICATED AND INSTALLED REPAIR DOUBLER. (M)SDR MWEA00602Insulation · missingMKE - FOUND FLOORBOARD E-9 MISSING AN INSULATION BLANKET AT STATION 639-680. FABRICATED AND INSTALLED NEW FLOOR PANEL AND REPLACED INSULATION BLANKET. (M)SDR MWEA00601Floorboard · damagedMKE - FOUND FLOORBOARD B-2 HAS PUNCTURE/IMPACT DAMAGE TO TOP SURFACE AT STATION 313. FABRICATED AND INSTALLED REPAIR PANEL AND SPLICE PANEL. (M)SDR MWEA00600Shear Tie · crackedMKE - FOUND STATION 1076 SHEAR TIE IS CRACKED BETWEEN LONGERON 1 AND LONGERON 2 RIGHT. REMOVED AND REPLACED SHEAR TIE AND SPLICE. (M)SDR MWEA00599Longeron · damagedMKE - FOUND LONGERON 12 LEFT HAS AN ELONGATED HOLE AT STATION 945. FABRICATED AND INSTALLED NEW STRINGER SECTION AND SPLICE. (M)SDR TWAA0013105Angle · crackedDURING OP 15 MAINT CHECK, FOUND IN FWD CARGO COMPT, THE FRONT SPAR SUPPORT ANGLE WAS CRACKED AT STA 604, LONGERON 24R. REMOVED AND REPLACED FITTING P/N 5914865-8 PER SRM 6-70-1 USING SAME TYPE FASTENERS PER SRM 51-30-2. SEALED PER SRM 51-20-0 FIG 7.SDR TWAA0013104Angle · crackedDURING OP 15 MAINT CHECK, FOUND IN FWD CARGO COMPT, THE FRONT SPAR SUPPORT ANGLE WAS CRACKED AT STA 604, LONGERON 24L. REMOVED AND REPLACED P/N 5914865-7 FITTING PER SRM 6-70-1 USING SAME TYPE FASTENERS PER SRM 51-30-2. SEALED PER SRM 51-20-0 FIG 7.SDR ABXA000398Longeron · crackedLONGERON 14 RIGHT AT STATION 1076 WAS CRACKED UNDER FRAME. REPLACED LONGERON SECTION IAW DC9 SRM 53-02.SDR L1GA200000242Floor Panel · crackedTWO CRACKS 1 INCH LONG ON FLOOR PANEL. INSTALLED REPAIR DOUBLER.SDR L1GA200000241Floor Panel · crackedTWO CRACKS APPROX 1 INCH LONG ON FLOOR PANEL. INSTALLED REPAIR DOUBLER.SDR L1GA200000240Floorboard · crackedA 1 INCH CRACK UPPER SURFACE OF FLOORBOARD FS 832. INSTALLED REPAIR DOUBLER UPPER SURFACE.SDR L1GA200000239Seat Track · damagedSEVERAL ELONGATED HOLES IN TOP RAIL OF SEAT TRACK. R2 TOP RAIL PILOTS SEAT. REPLACED TOP RAIL DOUBLER.
Back to Douglas DC-9-32