Douglas DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA200801931Battery Pack · inoperativeAUS OVERHEAD EMERGENCY LIGHTS IN CABIN INOPERATIVE. REPLACED BATTERY PACK AT B5 104 FOR OVERHEAD EMERGENCY LIGHTS IN CABIN. SYSTEM GROUND CHECKED NORMAL OPS. (CLOSED)SDR AALA200801932Battery Pack · inoperativeAUS OVERHEAD EMERGENCY LIGHTS IN CABIN INOPERATIVE. REPLACED BATTERY PACK AT B5 105 FOR OVERHEAD EMERGENCY LIGHTS IN CABIN. SYSTEM GROUND CHECKED NORMAL OPS. (CLOSED)SDR AALA200801933Battery Pack · inoperativeAUX OVERHEAD EMERGENCY LIGHTS IN CABIN INOPERATIVE. REPLACED BATTERY PACK AT BS 106 FOR OVERHEAD EMERGENCY LIGHTS IN CABIN. SYSTEM GROUND CHECKED NORMAL OPS. (CLOSED)SDR WX0A070221Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MX DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MX PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONALSDR AALA200801894Link · inoperativeSFO - INFLIGHT T1544/16 JUL. CREW REPORTED VIBRATION AND NOISE DURING CLIMB. ACFT DID FLYBY AT SFO AND NOTICED RT FORWARD NOSE GEAR DOOR OPEN. RETURNED TO SFO AND LANDED WITHOUT INCIDENT. REPLACED RT FORWARD NOSE GEAR DOOR LINK. SYSTEM GROUND CHECKED NORMSDR AALA200801824Battery Pack · inoperativeLGA - EMERGENCY LIGHTS IN MID CABIN INOPERATIVE. REPLACED BATTERY PACK AT SEAT ROW 20DEF FOR EMERGENCY LIGHTS IN MID CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR AALA200801825Battery Pack · inoperativeLGA - EMERGENCY LIGHTS IN AFT CABIN INOPERATIVE. REPLACED BATTERY PACK AT SEAT ROW 25DEF FOR EMERGENCY LIGHTS IN AFT CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR AALA200801826Battery Pack · inoperativeLGA - EMERGENCY LIGHTS IN AFT CABIN INOPERATIVE. REPLACED BATTERY PACK AT SEAT ROW 29DEF FOR EMERGENCY LIGHTS IN AFT CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR AALA200801827Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT OVERHEAD COCKPIT INOPERATIVAE. REPLACED BATTERY PACK AT B5-23 FOR EMERGENCY LIGHTS AT OVERHEAD COCKPIT. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR AALA200801828Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT SEAT ROWS 7DEF TO 9DEF INOPERATIVE. REPLACED BATTERY PACK AT B5 102 FOR EMERGENCY LIGHTS AT SEAT ROWS 7DEF TO 9DEF. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR AALA200801829Strap · brokenLGA - EMERGENCY FLASHLIGHT AT FORWARD UPPER POSITION HAS BROKEN SAFETY STRAP. REPLACED SAFETY STRAP FOR EMERGENCY FLASHLIGHT AT FORWARD UPPER POSITION. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR WX0A070219Battery · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MX DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MX PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFASDR AALA200801792Wire Harness · looseSFO - EMERGENCY LIGHT AT SEAT 24D INOPERATIVE. SECURED WIRE HARNESS FOR EMERGENCY LIGHT AT SEAT 24D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801790Light · looseSFO - EMERGENCY LIGHT AT SEAT 5E INOPERATIVE. SECURED LIGHT ASSEMBLY FOR EMERGENCY LIGHT AT SEAT 5E. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801791Lens · missingSFO - EMERGENCY LIGHT AT SEAT 5E MISSING LENS. REPLACED LENS FOR EMERGENCY LIGHT AT SEAT 5E. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR WX0A070216Power Supply · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MX DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MX PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONALSDR AALA200801732Battery · looseSFO - EMERGENCY LIGHTS AT OVERHEAD SEAT ROWS 3B TO 6B INOPERATIVE. RESEATED BATTERIES FOR EMERGENCY LIGHTS AT OVERHEAD SEAT ROWS 3B TO 6B. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR AALA200801728Battery Pack · inoperativeLGA - SEAT MOUNTED EMERGENCY LIGHT AT AFT CABIN INOPERATIVE. REPLACED BATTERY PACK AT AB5 4 FOR SEAT MOUNTED EMERGENCY LIGHT AT AFT CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR AALA200801727Battery Pack · inoperativeLGA - SEAT MOUNTED EMERGENCY LIGHT AT FORWARD CABIN INOPERATIVE. REPLACED BATTERY PACK AT AB5 1 FOR SEAT MOUNTED EMERGENCY LIGHT AT FORWARD CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR AALA200801726Wire · brokenLGA - EMERGENCY LIGHT AT FORWARD GALLEY EXIT SIGN INOPERATIVE. REPAIRED BROKEN WIRE AT TERMINAL FOR EMERGENCY LIGHT AT FORWARD GALLEY EXIT SIGN. SYSTEM GROUND CHECKED NORMAL OPERATION. (S)SDR AALA200801722Connector · looseSTL - EMERGENCY LIGHT AT SEAT ROW 22DEF INOPERATIVE. SECURED CONNECTOR FOR EMERGENCY LIGHT AT SEAT ROW 22DEF. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801694Light · inoperativeLGA - EMERGENCY LIGHT AT OVERHEAD SEAT 26D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT OVERHEAD SEAT 26D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801693Lamp · inoperativeLGA - EMERGENCY LIGHT AT RT HAND CABIN INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT RT HAND CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801692Anti-Ice Valve · malfunctionedDFW - INFLIGHT T1776/24JUN. CREW REPORTED NR ONE ENGINE START VALVE INDICATION AFTER TAKEOFF. CREW SHUT DOWN ENGINE. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. SINGLE ENGINE TIME EIGHT MINUTES. FOUND OUTBOARD ANTI ICE VALVE NOT CLOSING COMPLETELY. REPLSDR ASAA0883085Fitting · wornF/A REPORTS L 1 DOOR DIFFICULT TO CLOSE FOUND BAYONET FITTING WORN. REMOVED LINER, REMOVED SLIDE, REMOVED REPLACED BAYONET FITTING. FUNCTION CKD L 1 DOOR AS REQUIRED PER MM 52 11 00. REINSTALLED LINER. REINSTALLED SLIDE, OPS CKD DOOR, OPS CKD GOOD PER MM 2SDR AALA200801639Gcu · failedSTL INFLIGHT T2361/17JUN ORD TO DFW. CREW REPORTED LOSS OF RT AC BUD POWER AND RT ENGINE DRIVEN GENERATOR WOULD NOT HOLD A LOAD. LANDED STL WITHOUT INCIDENT. REPLACED GENERATOR CONTROL UNIT. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801644Generator · malfunctionedPHX INFLIGHT T1406/17JUN. CAPTAIN AND FIRST OFFICERS ELECTRONIC FLIGHT INSTRUMENT SYSTEM (EFIS) SCREENS CYCLED ON AND OFF FOR 60 TO 90 SECONDS FOLLOWED BY NR ONE GENERATOR TRIPPING. RESET NR ONE GENERATOR. EFIS CONTINUED TO CYCLE BUT THE NUMBER ONE GENERATOSDR 2008FA0000476Wheel · looseREJECTED TAKEOFF, DURING T/O ROLL, THERE WAS AND ABNORMAL AND ABRUPT VIBRATION IN THE NOSE SECTION. IAW AMM 32-21-04, PAGE 201/210 WAS CHECKED TORQUE LINKS ASSY BY LOOSE AND ADJUSTMENT ALSO WERE CHECK BOTH NOSE WHEELS, IAW AMM 32-40-02 PAGE 201, PRESS IN BOTHSDR AALA200801601Start Valve · malfunctionedDFW INFLIGHT T1106/13JUN. NR ONE ENGINE START VALVE OPENED IN FLIGHT. RETURNED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED NR ONE ENGINE START VALVE AND FILTER. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801598Light · brokenORD - EMERGENCY EXIT SIGN LIGHT AT RT SIDE OF AFT GALLEY EXIT DOOR BROKEN. REPLACED LIGHT ASSEMBLY FOR EMERGENCY EXIT SIGN LIGHT AT RT SIDE OF AFT GALLEY EXIT DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR WXOA070210Inlet · dentedFLIGHT CREW REPORTED DURING THE WALKAROUND INSPECTION A LARGE DENT ON THE RIGHT WING SLAT 0 AND THE RIGHT ENGINE INLET NACELLE. MAINTENANCE DEPARTMENT PERSONNEL REPLACED THE 0 SLAT AND WITH THE ASSISTANCE OF BOEING THE INLET COWL WAS INSPECTED AT THE END OF ESDR WXOA070208Transducer · looseFLIGHT CREW REPORTED THE "WHEEL NOT TURNING LIGHT ILLUMINATED ON TAKEOFF." THE AIRCRAFT ABORTED THE TAKEOFF ROLL AND RETURNED TO THE GATE. MAINTENANCE DEPARTMENT PERSONNEL INSPECTED THE AIRCRAFT AND DETERMINED THE WHEEL TRANSDUCER PINS LOOSE INSIDE THE WHEELSDR AALA200801651Wire · brokenSFO - EMERGENCY LIGHT AT SEAT 9D INOPERATIVE. REPAIRED BROKEN WIRE FOR EMERGENCY LIGHT AT SEAT 9D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR WXOA070212Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTME WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFSDR AALA200801541Turbine Blades · failedDFW INFLIGHT T1853/06JUN. CREW REPORTED LOUD NOISE FOLLOWED BY ENGINE GAS TEMPERTURE GOING TO 800 DEGREES. NR ONE ENGINE WAS SHUTDOWN BY CREW. LANDED DFW WITHOUT INCIDENT. SINGLE ENGINE TIME SIX MINUTES. FOUND TURBINE BLADE FAILURE AND METAL IN TAIL PIPE.SDR WXOA070211Battery · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR AALA200801498Connector · looseSFO - EMERGENCY LIGHT AT SEAT 27D INOPERATIVE. RECONNECTED SIDEWALL CONNECTOR FOR EMERGENCY LIGHT AT SEAT 27D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801451Lamp · inoperativeSFO - EMERGENCY LIGHT AT SEAT 27D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 27D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR WXOA070207Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFSDR AALA200801440Lamp · inoperativeSFO - EMERGENCY LIGHT AT OVERHEAD SEAT 27D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT OVERHEAD SEAT 27D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801439Lamp · inoperativeSFO - EMERGENCY LIGHT AT OVERHEAD SEAT 16B INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 16B. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801415Piston · bentONT - NOSE LANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF. REPLACED BENT PISTON. REPLACED CYLINDER SHOCK STRUT, SEALS AND UPPER AND LOWER TORQUE LINKS. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR WXOA070205Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFSDR AALA200801414Release Cable · frayedTUL - TAILCONE RELEASE CABLE IS FRAYED FROM LEFT HAND LATCH ASSEMBLY TO UPPER SUPPORT BRACKET AND FROM PULL HANDLE TO UPPER LEFT AND BLOCK ASSEMBLY. REPLACED TAIL CONE RELEASE CABLE. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR AALA200801389Lens · missingDFW - EMERGENCY LIGHT AT SEAT ROW 18D MISSING LENS. REPLACED LENS FOR EMERGENCY LIGHT AT SEAT ROW 18D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR ASAA0882977Doubler · corrodedFWD LAV SERVICE PANEL DOUBLER IS CORRODED AT FORWARD LOWER LATCH CUTOUT DAMAGED SECTION. FABRICATED LOCATED DRILLED AND INSTALLED REPAIR STRAP AND FILLER IAW ALASKA EA 5330 02339 AND AAR EA12687.SDR AALA200801350Csd · failedONT INFLIGHT T1419/19MAY STL TO LAS. NUMBER ONE ENGINE CONSTANT SPEED DRIVE OIL PRESSURE LOW INDICATION DURING FLIGHT. LANDED ONT WITHOUT INCIDENT. REPLACED NUMBER ONE ENGINE CONSTANT SPEED DRIVE AND CONSTANT SPEED DRIVE AIR/OIL HEAT EXCHANGER. SYSTEM GROUND CSDR AALA200801331Connector · corrodedAMA INFLIGHT T1661/17MAY DFW TO SEA. AFT CARGO FIRE INDICATION. FIRE BOTTLE DISCHARGED. LANDED AMA WITHOUT INCIDENT. NO EVIDENCE OF FIRE. FOUND CARGO ELECTRONICS UNIT CONNECTOR WITH CORROSION. REPLACED AFT CARGO ELECTRONICS UNTIL CONNECTOR AND FIRE BOTTLSDR 070198Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFSDR AALA200801264Start Valve · inoperativeLAX INFLIGHT T1928/09MAY - NUMBER ONE ENGINE START VALVE INDICATION ILLUMINATED. RETURNED TO LAX AND LANDED WITHOUT INCIDENT. REPLACED START VALVE FOR NUMBER ONE ENGINE. SYSTEM GROUND CHECKED NORMAL OPERATION.
Back to Douglas DC-9-83