Douglas DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0480337Floor Panel · corrodedOKC - DURING C-CHECK, FOUND PASSENGER CABIN FLOOR PANEL HAS BROKEN AND CORRODED INSERTS AT FS 160-120. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480334Floor Panel · crackedOKC - FOUND DURING C-CHECK, PASSENGER CABIN FLOOR PANEL HAS SEVERAL CRACKED INSERTS. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480333Floor Panel · crackedOKC - FOUND DURING C-CHECK, PASSENGER CABIN FLOOR PANEL HAS SEVERAL CRACKED AND MISSING INSERTS. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480332Floor Panel · crackedOKC - FOUND DURING C-CHECK, PASSENGER CABIN FLOOR PANEL HAS DISBONDED AT FS 160-200. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480331Floor Panel · crackedOKC - FOUND DURING C-CHECK, PASSENGER CABIN FLOOR PANEL HAS DISBONDED AND HAS CRACKED EDGE AT FS 160-180. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480330Floor Panel · corrodedOKC - FOUND DURING C-CHECK, PASSENGER CABIN FLOOR PANEL HAS CORRODED INSERTS AND COMPOSIT DAMAGE AT CORNER AT FS 160-200. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480329Floor Panel · corrodedOKC - FOUND DURING C-CHECK, PASSENGER CABIN FLOOR PANEL HAS CORRODED INSERTS AND HOLES NEAR FORWARD ENTRY AT FS 160-200. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480328Web · gougedFOUND C-CHECK, LEFT VENTRAL AFT ACCESSORY COMPARTMENT FRAME, WEB, GOUGED AT FS 1380. REPLACED WEB PER SRM 51-70-4. (M)SDR ASAA0480336Floor Panel · corrodedOKC - FOUND DURING C-CHECK, PASSENGER CABIN FLOOR PANEL HAS BROKEN AND CORRODED INSERTS AT FS 160-120. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480335Floor Panel · crushedOKC - FOUND DURING C-CHECK, PASSENGER CABIN FLOOR PANEL IS CRUSHED IN SEVERAL LOCATIONS AT FS 140-160. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR GTIA040408Light · brokenFTW - FOUND TWO EMERGENCY LIGHT ASSEMBLIES IN AFT ACCESSORY COMP BROKEN. REMOVED AND REPLACED EMERGENCY LIGHTS ASSEMBLY. (M)SDR GTIA040394Cable · misroutedDTW - FOUND TAIL SLIDE COVER KEVLAR CABLE NOT ROUTED CORRECTLY. INSTALLED KEVLAR CABLE CORRECTLY. (M)SDR AALA20040474Contactor · defectiveDFW - EMERGENCY DIRECTIONAL LIGHT MOUNTED ON FORWARD GALLEY WALL INOPERATIVE. REPINNED QUICK DISCONNECT CONTACT FOR EMERGENCY LIGHT MOUNTED ON FORWARD GALLEY WALL. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASAA0480281Module · inoperativePDX - FOUND ON LINE CHECK, EMERGENCY TRACK LIGHTS INOPERATIVE AT ROW 22. RECONNECTED LOOSE MODULE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)SDR ASAA0480282Power Supply · inoperativePDX - FOUND DURING LINE CHECK, EMERGENCY OVERHEAD CABIN LIGHTS INOPERATIVE FROM ROW 1 TO 8. REPLACED ASSOCIATED BATTERY PACK, POWER SUPPLY. LIGHTS THEN OPERATED PROPERLY. (M)SDR GTIA040416Lanyard · brokenFTW - FOUND R1 DOOR SLIDE HAS BROKEN LANYARD. REMOVED BROKEN LANYARD. INSTALLED NEW LANYARD. (M)SDR CA040419004Engine · failed(CAN) DEPARTING, WHILE CRUISING AT 31 000 FT, LOUD BANG COMING FROM LT ENGINE WITH DECREASING EPR , INCREASING EGT UP TO 575 C. DID NOT HAVE A RE-LIGHT WITH IGNITER ON INCREASING POWER WAS NOT RESPONDING, SO WE TREATED THAT AS A SEVERE DAMAGE OR SEPARATION SDR GTIA040329Bracket · looseDTW - FOUND GIRT BAR BRACKET ON FLOOR, DOOR L2 IS LOOSE. INSTALLED PROPER LENGTH SCREWS. (M)SDR GTIA040327Hinge · looseDTW - FLT 844 - FOUND L2 DOOR SLIDE PACK GIRT BAR HANDLE HINGES ARE LOOSE AND DO NOT HOLD GIRT BAR. FOUND GIRT BAR RETAINING BRACKET ON SLIDE COVER TO NEED ADJUSTING. ADJUSTED RETAINING BRACKET. NO FURTHER DEFECTS NOTED. (M)SDR GTIA040371Seat Track · corrodedFTW - FOUND RIGHT INBOARD SEAT TRACK STATION 836-1036 CORRODED AND GOUGED. REMOVED TRACK RIGHT INBOARD STATION 836-1036. LOCATED AND DRILLED NEW TRACK. LOCATED AND DRILLED SPLICES. INSTALLED NEW TRACKS AND THREE SPLICES. (M)SDR ASMF2004010Connector · damagedDURING TRANSIT CHECK, CAPTAIN REPORTED THAT THE LT VHF SYSTEM WAS OUT OF SERVICE. TECHNICAL PERSONNEL REPLACED RX VOR ILS AND CONTROL PANEL, BUT FAIL CONTINUED. WIRING WAS CHECKED DETECTING THE LINE 1RN11A22 OF THE CONNECTOR P10-407 (PIN H) DAMAGED. IT WAS RSDR GTIA040413Pin · damagedFTW - FOUND PORTABLE EMERGENCY LIGHT, FLASHLIGHT, DOES NOT WORK. REMOVED AND REINSTALLED NEW PINS FOR PLUG. (M)SDR ASMF200404010Connector · damagedDURING TRANSIT CHECK, CAPTAIN REPORTED THAT THE LEFT VHF SYSTEM WAS OUT OF SERVICE. TECHNICAL PERSONNEL REPLACED RX VOR ILS AND CONTROL PANEL, BUT FAIL CONTINUED. WIRING WAS CHECKED DETECTING THE LINE 1RN11A22 OF THE CONNECTOR P10-407 (PIN H) DAMAGED. REPAISDR AALA20040458Wire Harness · damagedTPA - EMERGENCY PATH SEAT MOUNTED LIGHTING AT SEAT 22DEF INOPERATIVE. FOUND AREA WHERE LIGHT MODULE MOUNTS TO SEAT AND WIRING HARNESS RETAINING FIXTURE ARE DAMAGED. SEAT NEEDS REPLACED. SEAT NOT IN STOCK AT TPA. PLACARD EMERGENCY ESCAPE PATH LIGHTING SYSTESDR ASAA0480278Floor Panel · delaminatedOKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL DELAMINATED AT FS 1309-1361. REPLACED FLOOR PANEL PER SRM 53-05. (M)SDR ASAA0480277Frame · damagedOKC - DURING HV CHECK, FOUND FRAME FASTENER HOLE ELONGATED ON UPPER SURFACE AT FS 1322. REPAIRED HOLE WITH FILLER, SHIM, AND ANGLE PER SRM 53-05. (M)SDR ASAA0480276Floor Panel · debondedOKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL HAT CHANNELS DISBONDED AT FS 256-294. BOND-REPAIRED PER MM 20-20-01. (M)SDR ASAA0480275Floor Panel · elongatedOKC - FOUND DURING HV CHECK, CABIN FLOOR PANEL HAS ELONGATED HOLES AT FS 200-256. FIBERGLASS REPAIR PER MM 25-00-00. (M)SDR ASAA0480274Floor Panel · debondedOKC - DURING HV CHECK, FOUND CABIN FLOOR PANEL DISBONDING AT SUPPORTS AT FS 200-256. BOND-REPAIRED PER MM 25-00-00. (M)SDR ASAA0480273Shear Tie · corrodedOKC - FOUND DURING HV CHECK, SHEAR TIE CORRODED AT FS 636. REPLACED SHEAR TIE PER SRM 51-30-5. (M)SDR ASAA0480271Wire · disconnectedLAX - PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS 'BROKEN' INOPERATIVE AT ROW 3. RECONNECTED WIRE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)SDR GTIA040274Downlock Sensor · malfunctionedFLL - FLT 1507 - NOSE GEAR UNSAFE LIGHT CAME ON IN CRUISE. COMPLIED WITH QRH, ACARS TO MAINTENANCE, LIGHT WENT OUT IN TURB. REMOVED AND REPLACED NOSE GEAR DOWN LOCK SENSOR. OPS CHECK OK ON GROUND. (M)SDR GTIA040347Stiffener · corrodedFTW - AFT PIT DOOR BEAM WEB STIFFENER STATION 1174 HAS CORROSION. FABRICATED STIFFENER. (M)SDR GTIA040415Stop Fitting · corrodedFTW - FOUND AFT PIT DOOR STOP FITTINGS CORRODED AND RUSTY STATION 1193 FORWARD AND AFT. LOCATED AND DRILLED TWO NEW DOOR STOP FITTINGS. (M)SDR GTIA040414Angle · corrodedFTW - FOUND AFT PIT DOOR BEAM TO SKIN ANGLE SUPPORT STATION 1155 CORRODED. ANGLE WAS FOUND TO BE OUT OF LIMITS. LOCATED AND DRILLED HOLES ANGLE SUPPORT. (M)SDR GTIA04412Clip · corrodedFTW - FOUND INBOARD T-CLIP JAM BEAM FS 1155 FASTENER HOLES ELONGATED, CORROSION. LOCATED AND DRILLED NEW INBOARD T-CLIP. (M)SDR GTIA040411Intercostal · corrodedFTW - FOUND AFT PIT INTERCOSTAL ASSEMBLY STATION 1150 BETWEEN L28R AND L29R HAS CORROSION. LOCATED AND DRILLED NEW INBOARD AND OUTBOARD T-CLIPS. (M)SDR GTIA040410Intercostal · corrodedFTW - FOUND AFT PIT INTERCOSTAL ASSY STATION 1155, L28R TO L29R CORRODED. FABRICATED NEW INTERCOSTAL. (M)SDR AALA20040444Battery Pack · inoperativeRDU - EMERGENCY EXIT LIGHTS IN FORWARD CABIN INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHTS IN FORWARD CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20040441Battery Pack · inoperativeTWO AFT EMERGENCY LIGHTS ON CEILING BETWEEN LEFT AND RIGHT HAND LAVATORY INOPERATIVE. REPLACED BATTERY PACK FOR TWO AFT EMERGENCY LIGHTS ON CEILING BETWEEN LEFT AND RIGHT HAND LAVATORY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASAA0480269Lanyard · misriggedOKC C-CHECK, AFT SERVICE DOOR EMERGENCY SLIDE FAILED TO DEPLOY DURING DEPLOYMENT TEST. SUSPECT MIS-RIGGED LANYARD, BUT INVESTIGATION IS UNDERWAY TO MORE DEFINITIVELY DETERMINE CAUSE. MFG (ENG-G DOC 3053)- MIS-RIGGING APPEARS TO HAVE BEEN IMPROPER FOLDING OF SDR GTIA040349Floor Panel · debondedFTW - FOUND MAIN CABIN FLOOR PANEL LEFT OUTBOARD FS 1250-1309 HAT CHANNEL ON BOTTOM IS DISBONDED ON FORWARD END AND CRACKED AT BOTH ENDS. REPAIRED DAMAGED HAT CHANNEL. BONDED FORWARD END OF HAT CHANNEL. (M)SDR GTIA040404Vane · damagedFTW - FOUND LEFT NR 5 OUTBOARD FLAP OUTBOARD VANE GOUGED, CHAFED AND CORRODED. REPAIRED FLAP VANE. (M)SDR GTIA040398Door Frame · corrodedFTW - FOUND CORROSION AT AFT PIT THRESHOLD BETWEEN SKIN AND DOUBLER. UPON FURTHER NOTICE, FOUND AFT DOOR JAMB BEAM CORRODED AND OUT OF LIMITS. REMOVED DOOR JAMB BEAM. REMOVED CORROSION FROM BETWEEN SKIN AND DOUBLER AT AFT THRESHOLD. FOUND SKIN TO BE OUT OFSDR GTIA040350Floorboard · crackedFTW - FOUND CABIN FLOORBOARD STATON 826-864 RIGHT CENTER AFT INBOARD CORNER IS CRACKED ON LOWER SURFACE. FABRICATED FLOORBOARD. (M)SDR GTIA040342Floorboard · cutFTW - FOUND COCKPIT FLOORBOARD SECTION CUT OUT AND HONEY COMB EXPOSED. FABRICATED NEW FLOORBOARD. (M)SDR GTIA040341Floorboard · crackedFTW - FOUND COCKPIT FLOORBOARD CRACKED, SPLIT, CUT, BROKEN, GOUGED AND BENT. FABRICATED NEW COCKPIT FLOORBOARD. (M)SDR GTIA040343Floor Panel · debondedFTW - FOUND COCKPIT FLOORBOARD POTTING COMPOUND AND DISBONDING. FABRICATE NEW FLOORBOARD. (M)SDR GTIA040265Lanyard · misinstalledDTW - FOUND R1 SLIDE COVER RELEASE LANYARD INSTALLED INCORRECTLY. CORRECTLY INSTALLED R1 SLIDE COVER RELEASE LANYARD. (M)SDR GTIA040262Skin · damagedLAS - FLT 1103 - FOUND DAMAGE ON RIGHT SIDE OF A/C AT STATION 522-560 LONGERON 20 DUE TO DAMAGE. FUSELAGE EXTERNAL DOUBLER REPAIR INSTALLED AT FS 503-560, L19R-23R PER FLIGHT VEHICLES DRAWING 53-04162-1 EA 5310-0408. (M)
Back to Douglas DC-9-83