Douglas DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20130502002Battery Pack · inoperativeCEILING EMERGENCY LIGHTS FROM ROWS 28 TO 30 INOPERATIVE. RESET BATTERY PACK. OPS CHECK NORMAL.SDR AALA20130502001Battery Pack · inoperativeCEILING EMERGENCY LIGHTS FROM ROWS 3 TO 6 INOPERATIVE. RESET BATTERY PACK. OPS CHECK NORMAL.SDR AALA20130501017Cusp Web · crackedRIGHT CUSP SHEET CRACK AT STATION 843 HORSE COLLAR FASTENER HOLE. INSTALLED DOUBLER FROM STATIONS 841 TO 845 PER AARD 53-20-00-16.SDR AALA20130501013Longeron · crackedCABIN, LONGERON 4 LEFT CRACKED, JUST FORWARD OF STATION 541. INSTALLED LONGERON SPLICE PER SRM 53-02-00 FIGURE 18 SHEET 1.SDR AALA20130501003Casting · crackedRIGHT WING, GROUND SPOILER ACTUATOR CASTING IS CRACKED AT INBOARD FORWARD AREA. INSTALLED FITTING/CASTING PER AARD 51-00-05-1.SDR YYFA20130501001Pa System · intermittentINTERFERENCE COMING THROUGH P/A SPEAKER INTERMITTENLY. FEEDBACK THROUGH OUT SPEAKERS IN CABIN.SDR AALA20130501001Portable Light · inoperativeLEFT NUMBER 1 DOOR PORTABLE EMERGENCY LIGHT INOPERATIVE. REPLACED LEFT NUMBER 1 DOOR PORTABLE EMERGENCY LIGHT. OPS CHECK NORMAL.SDR WX0A071567Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR AALA20130430004Connector · damagedEMERGENCY LIGHT AT SEAT 15D INOPERATIVE. REMOVED AND REPLACED CONNECTOR FOR EMERGENCY LIGHT AT SEAT 15D. OPS CHECK NORMAL.SDR WX0A071569Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR AALA20130425004Light · inoperativeESCAPE PATH LIGHT AT SEAT 28D INOPERATIVE. REPLACED LAMP FOR ESCAPE PATH LIGHT AT SEAT 28D. OPS CHECK NORMAL.SDR AALA20130425003Battery Pack · looseCEILING EMERGENCY LIGHTS FROM ROWS 28 TO 30 INOPERATIVE. SECURED BATTERY PACK. OPS CHECK NORMAL.SDR AALA20130425002Portable Light · inoperativeLEFT NUMBER 1 DOOR PORTABLE EMERGENCY LIGHT INOPERATIVE. REPLACED LEFT NUMBER 1 DOOR PORTABLE EMERGENCY LIGHT. OPS CHECK NORMAL.SDR WX0A071571Skin · chafedRIGHT VERTICAL STAB FAIRING CHAFED. REMOVED SKIN AND INSTALLED. REMOVED DAMAGE IN AFT SECTION, FABRICATED REPAIR PARTS AND INSTALLED.SDR WX0A071570Skin · gougedRIGHT VERTICAL STAB UPPER TIP FAIRING SKIN GOUGED. REMOVED SKIN, FABRICATED NEW SKIN AND INSTALLED.SDR AALA20130423002Battery · dischargedMID GALLEY EMERGENCY FLASHLIGHT NOT BLINKING. REMOVED AND REPLACED EMERGENCY FLASHLIGHT BATTERY. OPS CHECK NORMAL.SDR YYFA20130422001Connector · dirtyDURNING TAXI OUT LT INBD, RT INBD, LT OTBD, RT OTBD, ANTI-SKID LIGHTS CAME ON. FOUND CONNECTOR PLUG AT ANTI-SKID DUAL VALVE DIRTY. CLEANED CONNECTOR PLUG, AND OPS CHECK NORMAL.SDR YYFA2013 0421002Pa System · weakL1 PA VOLUME LOW.SDR YYFA20130421001Pa System · malfunctionedL-2 PA VOL SQUEALS.SDR YYFA20130402003Pa System · malfunctionedP/A INOPERATIVE IN FLIGHT. OPS CHECKED NORMAL ON GROUND COULD NOT DUPLICATE FAULT ON GROUND.SDR YYFA20130420001Pa System · malfunctionedP/A INOPERATIVE IN FLT. OPS CHECKED ON GROUND NORMAL COULD NOT DUPLICATE FAULT ON GROUNDSDR AALA20130419020Fan · inoperativeRIC - CREW REPORTED ELECTRICAL ODOR THROUGHOUT CABIN. EMERGENCY DECLARED, FLIGHT RETURNED RIC LANDED WITHOUT INCIDENT. AIRCRAFT WAS REMOVED FROM SERVICE. REPLACED RECIRCULATION FAN. SYSTEM GROUND CHECK NORMAL OPERATION.SDR YYFA20131804002Pa System · inoperativeL2 AND RC PA SQUEALS WHILE IN USE.SDR YYFA20131804001Airstair · inoperativeAFT AIRSTAIR CAT WALK WILL NOT STAY IN UP POSITION.SDR 7AHR20130416005Channel · corrodedG4 GALLEY BOTTOM STRUCTURE U CHANNEL BENT AND CORRODED. R & R U CHANNEL IAW SRM 51-30-1.SDR 7AHR20130416004Channel · corrodedG5 GALLEY BOTTOM SUPPORT STRUCTURE U CHANNELS CORRODED. R & R 3 EA U CHANNELS IAW SRM 51-30-2.SDR 7AHR20130416003Channel · corrodedG4 GALLEY NUMEROUS U CHANNELS CORRODED. R & R NUMEROUS U CHANNELS IAW SRM 51-30-2SDR 7AHR20130416001Web · crackedCRACKED CANTED WEB AT BS 1485 UPPER RT SIDE. REMOVED CRACKED WEB IAW SRM 51-30-05. FABRICATED WEB IAW SRM 51-10-3. INSTALLED WEB IAW SRM 51-30-01.SDR WX0A2013042271563Pin · missingL1 DOOR SLIDE SAFETY PIN NOT INSTALLED. REMOVED AND REPLACED L1 DOOR SLIDE REF TASK CARD R0902502.SDR 7AHR20130415010Bracket · crackedRT LOWER ATTACHED BRACKET OF HANDRAIL CRACKED. FABRICATED NEW BRACKET FROM 2024 T3 IAW SRM 51-10-2. INSTALLED NEW BRACKET IAW SRM 51-30-2.SDR 7AHR20130415004Floorbeam · corrodedLT LAV AREA BETWEEN FLOORBEAM AT BS 1309 CARGO CEILING PANEL ATTACH STRAP CORRODED. REMOVED CORRODED STRAP, FABRICATED AND INSTALLED REPAIR STRAP IAW SRM 51-30-0.SDR 7AHR20130415003Channel · corrodedAFT ENTRY DOOR HAT CHANNEL CORRODED. REMOVED CORRODED HAT CHANNEL IAW SRM 51-10-3A. FABRICATED REPAIR ANGLE IAW 51-10-2. DRILLED AND LOCATED REPAIR ANGLE IAW SRM 51-70-5. INSTALLED REPAIR ANGLE IAW SRM 51-30-8.SDR 7AHR20130415002Skin · crackedCRACK INDICATION AT BS 69.5 LONGERON 20 TO 21 LT SIDE SKIN. REMOVED ELEVEN RIVETS AT BS 69.5 AT LONGERON 20 TO 21 LT SIDE IAW SRM 51-10-4. REMOVED DAMAGE SKIN IAW SRM 53-04-02. FABRICATED LOCATED AND DRILLED REPAIR DOUBLER IAW SRM 51-10-04. INSTALLED REPAISDR 7AHR20130415001Torque Tube · wornRUDDER CONTROL TAB TORQUE TUBE HAS EXCESSIVE PLAY WHERE IT EXITS THE RUDDER DRIVE TORQUE TUBE, ACFT SIDE. REMOVED RUDDER DRIVE TORQUE TUBE AND RUDDER CONTOL TAB TORQUE TUBE. AFTER EVALUATION MANY COMPONENTS FOUND TO WORN BEYOUND SERVICEABLE LIMITS. REPLACED SDR AALA20130414005Battery Pack · not seatedRIGHT AND CENTER EMERGENCY LIGHTS BETWEEN AFT LAVATORIES INOPERATIVE. RESEATED BATTERY PACK FOR RIGHT AND CENTER EMERGENCY LIGHTS. OPS CHECK NORMA.LSDR AALA20130415001Portable Light · inoperativePORTABLE EMERGENCY LIGHT AT LEFT NUMBER 1 DOOR INOPERATIVE. REPLACED PORTABLE EMERGENCY LIGHT AT LEFT NUMBER 1 DOOR. OPS CHECK NORMAL.SDR AALA20130414006Battery · not seatedTAIL COMPARTMENT EMERGENCY LIGHTS INOP. RESEATED BATTERY, OPS CHECK GOOD.SDR AALA20130412020Sensor · faultyORD - CREW REPORTED AFTER GEAR WAS EXTENDED YELLOW GEAR DOOR OPEN LIGHT STAYED ON. ACCOMPLISHED GO AROUND AND CHECK LIST AND LIGHT STAYED ON. EMERGENCY DECLARED FLIGHT LANDED ORD WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND LEFT MAIN GEAR DOOR SESDR AALA20130412019Coalescer Bag · dirtyATL - FLIGHT ATTENDANTS REPORTED BURNING RUBBER SMELL WITH A HAZE IN AFT CABIN. EMERGENCY DECLARED FLIGHT RETURNED ATL LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. ACCOMPLISHED PACK BURN AND REPLACED COALESCER BAGS. SYSTEM GROUND CHECK NORMAL OPSDR YYFA20130412002Cabin Pressure · malfunctionedUNABLE TO MAINTAIN CABIN PRESSURE ON SINGLE PACK, REFER TO L.P. 65738. DIFF .5 AT 12,000 FEET, FLOW LIGHT CABIN ON AT 14,000. DURING CLIMB - INTERMITTENT, STEADY AT FL 210, CABIN CONTINUED CLIMBING, AT CABIN ALTTITUDE 10,000 INTO DESC RT PACK FLOW 3.5 PSI.SDR YYFA20130412001Fire Loop · no testLEFT ENGINE A LOOP WILL NOT TEST.SDR YYFA201304120001Pa System · inoperativeL2 PA INOPERATIVE.SDR 7AHR20130411001Floor Support · corrodedFWD CARGO COMPARTMENT RT SIDE FLOOR SUPPORT, FASTENER HOLES ARE CORRODED AND ALL HOLES ARE BLOWN OUT. REMOVED FLOOR SUPPORT IAW SRM 51-30-1. RECEIVED AND FABRICATED PART AND ALODINE AND PRIMED IAW SRM 51-10-2. INSTALLED REPAIR SUPPORT IAW SRM 51-30-01.SDR AALA20130410002Skin · corrodedFUSELAGE SKIN IS BULGED BETWEEN STATIONS 650 AND 655 AT LONGERON 30. ACCOMPLISHED REPAIR PER SRM 53-04-03 AND EA.SDR YYFA2013F00105Detector · intermittentINTERMITTENT FAIL INDICATION OF "B" SIDE/CHANNEL OF FWD CARGO DETECTOR: REPLACED FWD CARGO DETECTOR, OPS CHECKED GOOD.SDR YYFA20130410001Warning Light · illuminatedLT GEAR UNSAFE LIGHT REMAINED ILLUMINATED ON GEAR RETRACTION, QRH PROCEDURES COMPLETED/ RETURNED BACK TO FIELD.SDR 7AHR20130415008Attach Angle · brokenLEFT HORIZONTAL STAB AFT ATTACH CHANNEL BROKEN AT STAB, APPROX STA 56. REMOVED BROKEN ATTACHED CHANNEL ON LT HORZ STAB IAW SRM 51-30-2. FABRICATED REPLACEMENT ATTACH ANGLES, LOCATED, DRILLED AND INSTALLED IAW SRM 51-30-8, 51-10-04 AND 51-10-2.SDR 7AHR20130415007Attach Angle · crackedLT UPPER HORIZONTAL STABILIZER FAIRING, UPPER ATTACH ANGLES CRACKED AT FASTENERS HOLES. FABRICATED REPAIR ANGLES IAW SRM 51-10-2. LOCATED AND DRILLED THE FORWARD AND AFT ANGLE IAW SRM 51-10-04. INSTALLED NEW ANGLES IAW SRM 51-30-2.SDR 7AHR20130415005Retainer · corrodedAFT CARGO BAY RETAINING STRIPS HAVE SURFACE CORROSION. REMOVED CORRODED RETAINING STRIPS AND FABRICATED REPLACEMENT STRIPS AND INSTALLED REPLACEMENT STRIPS IAW SRM 51-10-04.SDR WX0A2013041571561Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE A
Back to Douglas DC-9-83