SDR AALA20130120005Battery Pack · dischargedCEILING EMERGENCY LIGHTS FROM ROWS 18 TO 21 INOPERATIVE. RESET MID EMERGENCY LIGHT BATTERY PACK. OPS CHECK NORMAL.SDR AALA20130120004Battery Pack · not seatedCEILING EMERGENCY LIGHTS FROM ROWS 7 TO 11 INOPERATIVE. RESEATED FORWARD EMERGENCY LIGHT BATTERY PACK. OPS CHECK NORMAL.SDR YYFA2013F00020Light · burned outEMERGENCY LIGHT OUT IN L1 GALLEY.SDR YYFA2013F00019Light · inoperativeOVER WING EXIT DOORS LOWER EMERGENCY LIGHTS INOPERATIVE.SDR AALA20130128007Skin · dentedFORWARD CARGO DOOR HAS SEVERAL DENTS IN OUTER SKIN AT UPPER CENTER OF DOOR. INSTALLED NEW SKIN PER ESO 80174.SDR WX0A071488Vane · chafedRIGHT WING O/B FLAP I/B VANE L/E STATION XW150 CHAFED OUT OF LIMITS. REMOVED DAMAGED AREA, FABRICATED DOUBLER AND BONDED.SDR WX0A071487Vane · chafedLEFT WING O/B FLAP I/B VANE L/E STATION XW150 CHAFED OUT OF LIMITS. REMOVED DAMAGED AREA, FABRICATED DOUBLER, HOT BOND REPAIRED.SDR YYFA20130117002Battery · inoperativeEMERGENCY & STANDBY LIGHTS INOPERATIVE IN CEILING. R & R BATTERIES AND BULBS IAW AMM 33-50-00.SDR YYFA20130116001Fuse · blownDURING SERVICE CHECK, FOUND ROW 23 OVER WING EXIT LIGHTS INOPERATIVE. REPLACED BLOWN FUSE ON LIGHT ASSY AT AFT OVERWING EXIT OPS CHECKED GOOD IAW AMM 33-53-00.SDR AALA20130117001Duct · disconnectedORF - CREW REPORTED TAIL COMPARMENT TEMPERATURE HIGH LIGHT ILLUMINATED DURING CLIMBOUT. EMERGENCY DECLARED FLIGHT RETURNED ORF LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. RESECURED LEFT PACK DISCHARGED DUCT THAT WAS DISCONNECTED. SYSTEM GROUNDSDR AALA20130125013Longeron · crackedLONGERON 17 LEFT CRACKED AT STATION 1309. INSTALLED SPLICE REPAIR PER SRM 53-02-00 FIGURE 18.SDR AALA20130125012Web · corrodedCORROSION ON SUBFLOOR UNDER G-1 GALLEY. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 53-20-00-16.SDR YYFA2013F00014Battery Pack · inoperativeFIVE EMERGENCY STANDBY LIGHTS INOPERATIVE IN CEILING. R & R BATTERIES AND BULBS IAW 33-50-00. OPS CHECKED GOOD.SDR YYFA2013F00013Fuse · blownDURING SERVICE CHECK, FOUND ROW 23 OVERWING EXIT LIGHTS INOPERATIVE. REPLACED BLOWN FUSE ON LIGHT ASSY AT AFT OVERWING EXIT. OPS CHECKED GOOD MM 33-53-00.SDR YYFA201301161001Pa System · inoperativePA SYSTEM L1 DOOR TO REAR INOPERATIVE.SDR YYFA20130115002Radio · inoperativeNR 1 VHF RADIO INOPERATIVE, JAMBED FREQUENCY.SDR YYFA20130115001Pa System · inoperativeFWD PA IN GALLEY NOT AUDIABLE:SDR AALA20130116004Structure · crackedLEFT FUSELAGE AFT AREA HAS CRACKED 4 INCHES FOWARD OF EMERGENCY HANDLE. ACCOMPLISHED PERMANENT REPAIR PER SRM 51-92-02.SDR 2013F00017Pa System · inoperativePA SYSTEM, L1 TO REAR INOPERATIVE.SDR YYFA2013F00015Vhf Comm · inoperativeNUMBER 1 VHF RADIO INOPERATIVE, JAMMED FREQUENCY.SDR 2013F00011Pa System · inoperativeFWD PA SPEAKER IN GALLEY NOT AUDIBLE.SDR AALA20130114027Skin · crackedCRACK IN RIGHT AFT FUSELAGE SKIN CANT FRAME AT STATION 1474. INSTALLED DOUBLER PER SRM 53-01-00 FIGURE 2 SHEET 3.SDR AALA20130114026Skin · crackedCRACK IN LEFT AFT FUSELAGE SKIN CANT FRAME AT STATION 1474. INSTALLED DOUBLER PER SRM 53-01-00 FIGURE 2 SHEET 3.SDR YYFA20130111001Handset · inoperativeFLT DECK TO CABIN COMMUNICATION VIA HANDSET INOP AT L1 POSITION.SDR AALA20130112002Battery Pack · not seatedOVERHEAD EMERGENCY LIGHTS FROM ROWS 18 TO 21 INOPERATIVE. RESEATED BATTERY PACK AT ROW 20. OPS CHECK NORMAL.SDR YYFA2013FA0000020Handset · inoperativeFLT DECK TO CABIN COMMUNICATION VIA HANDSET, INOPERATIVE AT L1 POSITION.SDR AALA20130115008Light · inoperativeCENTER CEILING EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP FOR CENTER CEILING EMERGENCY LIGHT. OPS CHECK NORMAL.SDR AALA20130111001Light · inoperativeRIGHT CEILING EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP FOR RIGHT CEILING EMERGENCY LIGHT. OPS CHECK NORMAL.SDR YYFA20130109001Cabin Pressure · malfunctionedCABIN ALTITUDE CLIMBED UNCONTROLLED, DECENDED QRH COMPLETED, CABIN ALT EXCEEDED 12,000 FT, CABIN O2.SDR AALA20130109018Actuator · inoperativeAUS - CREW REPORTED HORIZONTAL STABILIZER WAS JAMMED AND NOT RESPONDING TO ANY INPUT FROM THE FLIGHT CREW. EMERGENCY DECLARED FLIGHT LANDED AUS LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED HORIZONTAL STABILIZER PRIMARY ACTUATOR. SYSTEM SDR YYFA2013F00008Unknown · malfunctionedCABIN ALTITUDE CLIMBED UNCONTROLLED. DECESENDED, QRH COMPLETED. CABIN ALTITUDE EXCEEDED 12,000 FT CABIN 02 DEPLOYED.SDR 7AHR201308002Skin · corrodedRIGHT AFT WING TO BODY FAIRING ACFT SKIN HAS EIGHT FASTNER HOLES WITH CORROSION. AFTER BLEND OUTS FOUND NUMEROUS FASTENER HOLES TO HAVE IN EXCESS OF 20 PERCENT MATERIAL LOSS. REMOVED PRE-EXISTING DOUBLER. FABRICATED A REPLACEMENT DOUBLER IAW SRM 53-04, FIG 57SDR 7AHR20130108001Seat Track · corrodedCORROSION ON SEAT TRACK BETWEEN BS 1174 AND 1200 AT LT LBL 24. DETERMIND TO BE OUT OF LIMITS. SEAT TRACK R & R IAW SRM 53-05, FIG 4F.SDR WX0A071477Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR AALA20130108001Battery · dischargedFORWARD ENTRY LOWER EMERGENCY FLASHLIGHT BATTERY HAS NO CHARGE. REPLACED EMERGENCY FLASHLIGHT BATTERY. OPS CHECK NORMAL.SDR WX0A071470Longeron · crackedRIGHT MLG W/W LONGERON 20 CRACKED AT STATION 993 AREA. REMOVED CRACKED AREA AND VERIFIED NO CRACKS. FABRICATED SHIM, FILLER, DOUBLER. LOCATED DRILLED AND INSTALLED.SDR 7AHR20130107001Duct · damagedNR 2 ENGINE HAS A DAMAGED LOWER TURBINE FAN DUCT SEGMENT. R & R THE LOWER TURBINE FAN DUCT SEGMENT IAW OVERHAUL MANUAL 72-00-00.SDR YYFA20130105001Pa System · inoperativePA SYSTEM INOP AT L1.SDR WX0A071478Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR 2013F00007Pa System · inoperativePA SYSTEM INOP AT L1 DOOR.SDR AALA20130125011Skin · dentedDENT IN FUSELAGE SKIN AT FRAME STATION 484 BETWEEN LONGERON 27 AND 28 RIGHT. INSTALLED CLASS 1 EXTERNAL DOUBLER WITH INTERNAL FINGER DOUBLERS PER SRM 53-04-03 FIG 8 SHT 8.SDR YYFA20130101001Handset · inoperativeREF SDR YYFA20130101001: FLIGHT DECK INTERPHONE HANDSET COMMUNICATION IS UNAUDIABLESDR AALA20121231003Skin · crackedTWO DENTS WITH CRACKS ON LOWER FUSELAGE, FORWARD OF THE FORWARD CARGO DOOR. INSTALLED DOUBLER PER SRM 53-04-03, FIGURE 2.SDR AALA20121231002Skin · dentedRIGHT FORWARD FUSELAGE HAS 2 DENTS FROM STATIONS 253 TO 275, LONGERONS 27 TO 28 RIGHT. INSTALLED DOUBLER PER SRM 53-04-3 FIGURE 2.SDR WX0A071463Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR FX7A2013F00000Handset · inoperativeFLIGHT DECK TO L1 INTERPHONE HANDSET, COMMUNICATION IS UNAUDIBLE.SDR WX0A071460Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERSDR AALA20121228002Battery · looseRIGHT AND CENTER CEILING EMERGENCY LIGHTS BETWEEN AFT LAVATORIES INOPERATIVE. RE-SECURED LOOSE BATTERIES. OPS CHECK NORMAL.SDR AALA20121228001Portable Light · inoperativeLEFT NUMBER 1 DOOR PORTABLE EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSEMBLY FOR LEFT NUMBER 1 DOOR PORTABLE EMERGENCY LIGHT. OPS CHECK NORMAL.SDR YYFA20121224001Interphone · intermittentPA INTERPHONE L1 AND FLT DECK INTERMITTENT.
Back to Douglas DC-9-83