SDR SIMA202004232001Light · inoperativeAFT LH EXTERIOR EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED AFT LH EXTERIOR EMERGENCY LIGHT IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD. NO FURTHER DEFECTS NOTEDSDR SIMA202004231002Hose · disconnectedDURING CLIMB THE AIRCRAFT FAILED TO PRESSURIZE. PACK 2 CLSD AND BLEED 2 CLSD AFTER TAKE-OFF -- CYCLED, THEM PACK2 & BLEED 2 WERE OPEN -- THEN ABOUT 5 SECONDS LATER PACK 1-2 CLOSED POSTED -- RAN QRH CHECKLIST: GOT PACK 1 BACK EVENTUALLY, BUT NOT PACK 2-C/A-FOUNSDR SIMA202004221001Light · odorELECTRICAL BURNING SMELL NOTED BY FA AND MULTIPLE PASSENGERS DURING CLIMBOUT. PERFORMED FIM 25-31-00, NO ODOR NOTED. INSPECTED ALL HARNESSES AND RELAYS IN AND AROUND COCKPIT, FA FWD SEAT AND ALL ENTRY WAY LIGHTS, EMERGENCY FLASHLIGHTS. NO ODOR NOTED, GROSDR SIMA2020042119001Wire · brokenROW 3 THRU 7 FLOOR PROXIMITY EMERGENCY LIGHTS ARE INOP.-C/A-REMOVED AND REPLACED #2 EMERGENCY BATTERY AND POWER SUPPLY IAW EMB 145 AMM 33-50-04, OP CHECK BAD. FOUND THE DC RETURN WIRE TO INVERTER BROKEN AT GROUNDING BLOCK. REPAIRED WIRE W192-8689-22N IAW EMB 1SDR HNAA2020042000144A/C Pack · odorDURING PUSH BACK, WITH PACK 1 ON, SMOKE BEGIN TO ACCUMULATE IN THE COCKPIT. WAS ACCOMPANIED BY AN ELECTRICAL SMELL. SEEMED TO COME FROM FO SIDE. COULD NOT DUPLICATE PRESENCE OF WHITE SMOKE. FOUND NO VISUAL SIGN OF BURNING. NOTICED BURNING SMELL WITH PACK 1 SDR ASOA2020042385015Tray · defectiveDURING MX INSPECTION THE LH AND RH OVERWING EMERGENCY LIGHT WOULD NOT ILLUMINATE. MX REMOVED AND REPLACED #4 EMERGENCY BATTERY TRAY WITH OPERATIONAL CHECK GOOD. A/C WAS APPROVED FOR RETURN TO SERVICE 4/20/20.SDR HNAA20200420144Proximity Switch · unsecureNR 1 ENGINE REVERSER DISAGREE MESSAGE ON TAKEOFF ROLL. FOUND 2 PROXIMITY SWITCHES IN NLG TO BE LOOSE. SECURED THE CONNECTORS IAW SWPM 20-50-00. OPS CHECKED GOOD.SDR HNAA2020042000143Connector · loosePDIS 626 78-34 2222221 17APR20 PHL CLOSE
E-1 REV DISAGREE MESSAGE ON TAKEOFF ROLL.
28574 00 PCS
FACT 17APR20 23:17 ALB
FOUND 2 PROX SWITCHES IN NLG TO BE LOOSE. RESECURED
SDR SIMA20200417002Door Frame · corrodedDURING HMBV INSPECTION, QC FOUND PAX DOOR LOWER FRAME CORRODED AT LINER NUT PLATE HOLES.-C/A-PERFORMED PERMANENT REPAIR TO CORRODED AREAS ON PAX DOOR LOWER FRAME AT NUT PLATE HOLES IAW EMB 145 SRM 52-10-04RE AND ETN-EM-52-041.SDR SIMA20200417001Charger · failedREMOVE AND REINSTALL #1 EMERGENCY BATTERY POWER SUPPLY -C/A-REMOVED AND REPLACED THE #1 BATTERY AND CHARGER IAW EMB 145 AMM 33-50-04, SYS CKS GOOD.SDR SIMA2020041716006Light · inoperativeFOUND LH OVERWING EMG LIGHT INOP DURING PS-1-C/A-REPLACE LAMP IAW AMM 33-50-10 OPS CHECK GOODSDR SIMA2020041716009Rib · crackedDURING HMBV INSPECTION, QA FOUND THE LH WING RIB 21 CRACKED INSIDE 551CB-C/A-PERFORMED PERMANENT REPAIR ON LH WING RIB 21 IAW EMB 145 SRM 57-20-07-RE ITEM 4SDR SIMA2020041716008Door Frame · corrodedDURING HMBV INSPECTION, QC FOUND CORROSION ON FR 22 AT SERVICE DOOR LOWER CUT-OUT.-C/A-PERFORMED PERMANENT REPAIR TO FR 22 AT SERVICE DOOR CUT-OUT IAW EMB 145 SRM 53-00-04RE.SDR SIMA2020041716005Skin · puncturedDURING HMBV INSPECTION, QC FOUND RUDDER II TRAILING EDGE LOWER LH SKIN PUNCTURED.-C/A-REPAIRED RUDDER II LOWER LH SKIN IAW ERS-EM-55MR-841.SDR SIMA2020041716004Support Bracket · crackedDURING HMBV INSPECTION, QC FOUND PAX DOOR HANDLE BOX SUPPORT ASSY BRACKET CRACKED.-C/A-REMOVED AND REPLACED PAX DOOR HANDLE BOX SUPPORT BRACKET IAW EMB 145 SRM 51-40-02.SDR SIMA2020041716010Structure · corrodedDURING HMBV INSPECTION, QC FOUND LAV BUCKET CORRODED AROUND TOILET WASTE VALVE MOUNTING FLANGE.-C/A-REMOVED AND REPLACED LAV BUCKET IAW EMB 145 SRM 51-40-02.SDR SIMA2020041716003Frame · gougedFR 65 Z FRAME IS GOUGED AROUND 7 SCREW HOLES LH SIDE-C/A-PERFORMED REPAIR TO FR 65Z IAW ERS-EM-53MR-4084 REV1.SDR SIMA2020041716007Light · inoperativeLH INTERIOR OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH INTERIOR OVERWING EMERGENCY LIGHT IAW EMB AMM 33-50-07-000-801-A AND 33-50-07-400-801-A OPC GOOD ENDSDR SIMA2020041716011Door Sill · corrodedSSI 53-20-10 LOWER SERVICE DOOR SILL CORRODED AROUND MULTIPLE NUTPLATE HOLES-C/A-REMOVED AND REPLACED LOWER SERVICE DOOR SILL IAW EMB 145 SRM 51-40-02 AND SRM 51-20-01. REPAIR P/N: 145-22178-605SDR ASOA2020042355014Unknown · malfunctionedDURING MX INSPECTION THE EXIT AISLE PATH LIGHTING FROM ROW 8 TO 11 WAS FOUND INOPERATIVE. ALSO EXIT ROW 18 UPPER AND LOWER SIDEWALL SIGNS INOP AND ROW 18 AFT CEILING EXIT SIGN INOP. MX PERFORMED OPS CHECK OF EMERGENCY LIGHTS WITH OPS CHECK GOOD. A/C WAS APPROVSDR SIMA2020041615002Frame · crackedDURING HMBV INSPECTION, QC FOUND FR 72 CRACKED BETWEEN STGR 16L-17L.-C/A-PERFORMED PERMANENT REPAIR TO CRACK ON FR 72 IAW EMB 145 SRM 53-00-04RE.SDR SIMA2020041615001Battery Pack · dischargedSERVICE DOOR EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED #2 EMERGENCY POWER SUPPLY UNIT AND BATTERY PACK IAW AMM 33-50-04. PERFORMED WIRING REPAIR ON WIRE W192-8627-20 AT SERVICE DOOR HINGE WIRING BUNDLE IAW SWPM 20-21-00 AND WM 33-50-50. OPS CHECK GOOD. CHASDR ASOA2020050843037Frame · crackedDURING C CHECK INSPECTION FOUND CRACK OUT OF RIVET HEAD ON FRAME 81 BETWEEN STRINGER 2L-3L. MAINTENANCE REPAIRED I/A/W ETD2020-145-015556SDR ASOA2020050843036Splice Plate · crackedDURING C CHECK INSPECTION FOUND FRAME TO SKIN SPLICE PLATE @ FRAME 81 BETWEEN STRINGER 2L-2R CRACKED. MAINTENANCE REPLACED THE CRACKED SKIN SPLICE PLATE.SDR SIMA2020041714007Guide · corrodedSSI 53-20-10 AFT SERVICE DOOR CUTOUT CORRODED UNDER AFT LOWER TEFLON GUIDE-C/A-REMOVED AND RE[LACED AFT SERVICE DOOR CUTOUT UNDER AFT TEFLON GUIDE (FR 22 BTW STGR 14R-15R) IAW ERS-EM-53MR-4096. REPLACEMENT PART PN 145-22191-015SDR SIMA2020041614003Floor Support · corrodedSSI 53-20-11 LH OMEGA BEAM SIDEWALL IS PITTED ABOVE CROSSBEAM AT FR 44.-C/A-ACCOMPLISHED LH OMEGA BEAM REPAIR IAW ENVOY ERS-EM-53MR-4089SDR SIMA2020041614004Floor Support · corrodedSSI 53-20-11 LH OMEGA BEAM CORRODED ON THE SIDE AT FR 29 CROSS BEAM-C/A-ACCOMPLISHED LH OMEGA BEAM REPAIR IAW ENVOY ERS-EM-53MR-4090SDR SIMA2020041614006Light · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH OVERWING EMERGENCY LIGHT ASSEMBLY IAW EMB 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA2020041614005Inverter · inoperativeFLOOR PROXIMITY LIGHT STRIP #2 INOP-C/A-T/S LIGHT STRIP IAW EMB 145 FIM TASK 33-50-00-810-804-A FOUND ELECTRICAL CONNECTION DAMAGED ON STRIP #2 REMOVED AND REPLACED DAMAGED STRIP IAW EMB 145 AMM 33-50-12 NO FIX FOUND #2 INVERTER TO BE AT FAULT RAR INVERTER IAWSDR SIMA20200414001Fitting · damagedDURING HMBV INSPECTION, QC FOUND A RH AILERON DAMPER FITTING BUSHING HOLE ELONGATED. -C/A-REMOVED AND REPLACED RH AILERON DAMPER FITTING IAW EO EM-27MR-112.SDR SIMA20200414002Door Sill · corrodedDURING HMBV INSPECTION. QC FOUND THE SERVICE DOOR CENTER SILL CORRODED.-C/A-REMOVED AND REPLACED SERVICE DOOR CENTER SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2020041400133Switch · wornPDIS 626 78-34 2222182 13APR20 ROC CLOSE
ENG 1 TR REV DISAGREE EICAS MSG ILLUMINATED ON TAKEO
FF ROLL MAX SPEED 70 KNOTS.
MEL 13APR20 18:46 ROC C10428 78-2
ENG 1(2) REV DISAGREE MESS
FACT 14APR20 03:00 MDT
SDR HNAA2020041400132Wire · chafedPDIS 637 24-31 2225662 13APR20 BWI ASSGN
ELECTRICAL BURNING SMELL IN COCK PIT, IN FLIGHT
MDIS 637 24-31 2225663 13APR20 BWI ASSGN
TS SMOKE SMELL IN COCKPIT FOUND NUM 3 GEN NEGITIVE
(E-) WITH A CHAFE INSTALLED INSULATINSDR SIMA20200413002Wire · brokenFLOOR PROXIMITY LIGHT STRIP # 6 WIRE BROKE OFF LIGHT.FOUND ON CLOSE UP.-C/A-REMOVED AND REPLACED FLOOR PROXIMITY LIGHT STRIP # 6 IAW EMB 145 AMM 33-50-12. SEE NRTC BOW339262 FOR OPS CHECK.SDR SIMA20200413001Wire · brokenEMERGENCY LIGHT STRIP WIRE AFT OF CONNECTOR SP9115 HAS BROKEN STRANDS MARKED. FOUND ON CLOSE UP.-C/A-REPAIRED WIRE W192-8760-22 AFT OF SPLICE SP9115 IAW EMB 145 SWPM 20-21-00.SDR SIMA20200413003Wire · damagedEMERGENCY LIGHT STRIP WIRE AFT OF CONNECTOR SP9036 HAS DAMAGED INSULATION.FOUND ON CLOSE UP.-C/A-REPAIRED WIRE INSULATION ON W192-8679-22 AFT OF SPLICE SP9036 IAW EMB 145 SWPM 20-21-00.SDR SIMA20200413004Skin · corrodedINTERNAL FUSELAGE SKIN CORROSION AT FR 11-12 BETWEEN STGR 20R-21R ON PREVIOUS BLEND.-C/A-ACCOMPLISHED PERMANENT REPAIR ON INTERNAL FUSELAGE SKIN CORROSION BETWEEN FR 11-12 AND STGR 20R-21R IAW ERS-EM-53MR-4083. REPAIR MATERIALS: DOUBLER: AL CLAD 2024-T3, 0.050SDR ASOA202004133031Inverter · inoperativeDURING ROUTINE MAINTENANCE LEFT AND RIGHT OVERWING FORWARD EMERGENCY LIGHTS WERE FOUND INOPERATIVE. MAINTENANCE REPLACED THE #4 EMERGENCY LIGHT BATTERY INVERTER. OPERATIONAL CHECKS WERE GOOD.SDR ASOA2020041624012Light · inoperativeIAH - FLIGHT 3985, DURING MAINTENANCE INSPECTION THE AISLE PATH LIGHT STRIP AT ROW 8-9 WAS FOUND TO BE INOPERATIVE. MAINTENANCE PLACED THE LIGHT STRIP ON MEL AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ON 04/15/20 IAH MAINTENANCE REMOVED AND REPLACED SDR SIMA2020041312001Inverter · failedEMERGENCY EXIT SIGN AT SEAT 3BC INOP-C/A-T/S ,REPLACEDAND REMOVED EXIT IDENTIFYER SIGN IAW EMB AMM 33-50-13-000-801-A ZND 33-50-13-400-801-A, NO FIX. REMOVED AND REPLACED # 2 EMERGENCY BATTERY IAW EMB AMM 33-50-04-000-801-A ND 33-50-04-400-801-A, NO FIX. RAR #SDR SIMA2020041312002Light · inoperativeAFT CEILING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED AFT CEILING EMERGENCY LIGHT IAW EMB AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOODSDR HNAA2020041500142Skin · dentedDENT IN EXTERIOR FUSELAGE SKIN ON FR 67 BETWEEN STRINGERS
13R AND 14R...PERFORMED CUTOUT AS REQUIRED AND FABRICATED
AND INSTALLED DOUBLER AND FILLER FOR REPAIR OF FUSELAGE
EXTERNAL SKIN AT FR 67 BETWEEN STGR 13R
AND 14R IAW EMB-145 SRM 53-31-01 RE ITEM 4
SDR SIMA2020062541005Frame · crackedFRAME 73 CRACKED BETWEEN STRINGERS 15R AND 16R. REMOVED AND REPLACED THE FRAME LOWER SECTION IAW SRM 51-40-02.SDR SIMA2020062541004Holder · brokenFIVE PROXIMITY LIGHT HOLDERS AND FIVE RT SIDEWALLS ARE BROKEN. R & R THE LIGHT HOLDERS AND THE RH SIDEWALLS IAW AMM 33-50-12.SDR SIMA2020062541003Wire Splice · damagedSERVICE DOOR LOWER LH EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED REMOVABLE SPLICE SP9043 ON SERVICE DOOR LOWER EMERGENCY LIGHT IAW SWPM 20-21-00, WM 33-50-50 AND AMM 33-50-00. OPS CHECK GOOD.SDR SIMA2020062541002Cradle · brokenAFT CABIN FLASHLIGHT HOLDER BROKEN.-C/A-COMPLETE:REMOVED AND REPLACED AFT CABIN FLASHLIGHT HOLDER IAW EMB 145 AMM 33-51-01.SDR SIMA2020062541001Wire · brokenTWO PROXIMITY LIGHTS WITHOUT ARROWS AND ONE PROXIMITY LIGHT WITH ARROWS HAS BROKEN WIRES. REMOVED AND REPLACED TWO LIGHTS WITHOUT ARROWS AND ONE LIGHT WITH ARROWS IAW AMM 33-50-12. INSTALLED AND OPS CHECKED.SDR HNAA2020041300131Connector · disconnectedCOCKPIT AND MAIN ENTRY OVERHEAD EMERGENCY LIGHTS INOP. DROPPED MAIN DOOR REGION CEILING PANEL AND FOUND EMERGENCY COURTESY LIGHT CANNON PLUG NOT CONNECTED. RECONNECTED CANNON PLUG AND REINSTALLED MAIN ENTRY REGION CEILING PANEL REF AMM 25-22-04-000/400-801-A. SDR HNAA2020041300130Connector · disconnectedFWD EMERGENCY EXIT LIGHT ABOVE FLIGHT ATTENDANT SEAT INOP. DROPPED MAIN DOOR REGION CEILING PANEL AND FOUND EMERGENCY COURTESY LIGHT CANNON PLUG NOT CONNECTED. RECONNECTED CANNON PLUG AND REINSTALLED MAIN ENTRY REGION CEILING PANEL REF AMM 25-22-04-000/400-801SDR SIMA2020051909005Nut Plate · brokenRH OVERWING EMERGENCY LIGHT HOUSING HAS 1EA NUTPLATE BROKEN-C/A-REMOVED AND REPLACED RH OVERWING EMERGENCY LIGHT HOUSING IAW EMB 145 AMM 33-50-10. OPS CK GOOD