SDR HNAA2019093000292Light · inoperativeNDIS 665 33-40 0020660 27SEP19 SBY CLOSE
OVER WING EMERGENCY LIGHT INOP ON RH SIDE
35717 00 BRA
FACT 27SEP19 13:31 SBY
R AND R OVER WING EMERGENCY LIGHT IAW AMM TASK 33-50
SDR HNAA2019093000291Sign · inoperativeNDIS 654 33-50 0010340 27SEP19 SBY CLOSE
EMERGENCY EXIT SIGN ABOVE FLIGHT ATTENDANT SEAT DOES
NOT ILLUMINATE
FACT 27SEP19 15:06 SBY
REMOVED AND REINSTALLED EMERGENCY EXIT SIGN CORRECTL
Y. LIGHT ILLUMINATES. SDR HNAA2019093000290Valve · malfunctionedPDIS 639 36-21 2095942 26SEP19 PWM CLOSE
ON TAKEOFF ROLL BLD 1 VLV FAIL MESSAGE APPEARED ON E
ICAS.
FACT 27SEP19 03:49 MDT
R&R'D #1 BLEED VALVE & REACTIVATED IRT EMB MM
36-11-05. GROUND RUN OPS CHECK GOOD ATSDR SIMA20190926001Web · gougedDURING HMBV INSPECTION, QA FOUND THE BAGGAGE DOOR INTERNAL WEB GOUGED ABOVE AND AFT OF THE VENT PANEL-C/A-PERFORMED PERMANENT REPAIR ON THE BAGGAGE DOOR INTERNAL WEB ABOVE AND AFT OF THE VENT PANEL IAW EMB 145 SRM 52-30-01 AND ETN-EM-52-043. REPAIR DOUBLER: SDR SIMA201909265001Light · inoperativeROW 15A FLOOR PROXIMITY STRIP INOP. REMOVED AND REPLACED 15A FLOOR PROX LIGHT IAW AMM 33-50-12 OPS CHECK GOOD.SDR RAIA2019100492503Tee Fitting · corrodedRH I/B & O/B T-CAPS UNDER LOWER CARBON FIBER RING HAS CORROSION FRAME 61. REMOVED I/B & O/B T-CAP UNDER CARBON FIBER RING. INSTALLED NEW RH I/B & O/B T-CAPS UNDER CARBON RING AT FR61.SDR HNAA2019093000289Light · inoperativeNDIS 614 33-50 0013140 25SEP19 SBY CLOSE
SERVICE DOOR EXTERNAL LIGHT IS INOP (EMERGENCY LIGHT)
27863 00 SSM
FACT 25SEP19 10:34 SBY
R+R SERVICE DOOR EXTERNAL LIGHT ASSY IAW AMM 33-50SDR SIMA20190925003Light · burnedVISIBLE SMOKE AND ASSOCIATIED ELECTRICAL BURNING SMELL EMINATING FROM CAPTAINS YOKE, FLOOR AREA. INTERNAL APU POWER WAS SUPPYING ELECTRICAL LOADS. EVENT OCCURED AFTER STICK SHAKER/PUSHER, TRIM AND HYDFLIGHT CONTROL TESTS. TOKE MAP LIGHT WAS OFF. TESTS WERE SATSDR SIMA20190925004Door Sill · corrodedDURING HMBV INSPECTION, QC FOUND THE CARGO DOOR CUTOUT LWR SILL CORRODED. -C/A-REMOVED AND REPLACED CARGO DOOR LWR SILL IAW EMB 145 SRM 51-40-02 AND 51-20-03.SDR HNAA2019092500288Relay · failedON TAXI OUT, SPOILER FAIL EICAS MESSAGE. FIX: R&RD TWO RELAYS AND SPC UNIT, REF FIM TASK 27-63-00-810-806-1 AND AMM 27-63-02. TAXIED AIRCRAFT ABOVE 19 KNTS, NO SPOILER MESSAGE ON EICAS OR CMC. OPS CHECK GOOD. OK FOR SERVICE.SDR HNAA2019092500287Warning Message · false activationCMC SHOWS MESSAGE OF ENG 1 FADEC A. CREW RETURNED TO GATE DUE TO MESSAGE. CREW REPORTED POWER SURGE WHEN SWITCHING FROM GPU TO AIRCRAFT PWR. FIX: AIRCRAFT CREW OPERATED BOTH ENGINES. NO EICAS MESSAGE. SYS OPERATES NORMALLY.SDR HNAA2019092500286Warning System · false activationSPOILER FAIL MESSAGE ON TAXI OUT. FIX: T/S PER FIM 27-63-00-810-802-A. NO RELEVANT MESSAGES DISPLAYED AT THIS TIME. SUSPECT A TRANSITORY CONDITION. OK FOR SERVICE.SDR HNAA2019092500283Wire · damagedPAX DOOR EMERGENCY LIGHT INTERMITTENT. FIX: REPAIRED DAMAGED WIRE AT LIGHT ASSY BY REPLACING TERMINAL END PIN.SDR SIMA20190924002Tire · wornWHEN EXITING RUNWAY (RIGHT TURN) GRINDING NOISE FROM NOSE AREA, BELOW FLIGHT DECK. BURNING SMELL IN FLIGHT DECK SHORT TIME LATER. BURNING RUBBER SMELL. "TRANSFERRED TO NRWC 908-ORD-04440" PERFORM ETN-EM-72-034 PER MOC FOR BURNING RUBBER SMELL IN COCKPIT. CSDR SIMA20190923003Profile · damagedMULTIPLE REMOVED EMERGENCY LIGHT STRIP PROFILES DAMAGED.-C/A-REPLACED ALL DAMAGED EMERGENCY LIGHT STRIP PROFILES AS REQUIRED. REF NRWC 697-MQT-04283 FOR REINSTALLATION.SDR SIMA20190923002Connector · damagedEMERGENCY LIGHT CONNECTOR AT FLOOR PANEL 251DF IS DAMAGED.-C/A-RAR'D EMERGENCY LIGHT CONNECTOR AT FLOOR PANEL 251DF IAW SWPM 20-21-00.SDR ASOA201909234053Inverter · inoperativeIAH - FLIGHT 4155, DURING MAINTENANCE INSPECTION THE LEFT HAND OVER WING EXIT SHROUD EXIT MARKER FAILED TO ILLUMINATE. MAINTENANCE REMOVED AND REPLACED THE #4 INVERTER, OPERATIONALLY TESTED WITH NO DEFECTS AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20190923001Light · inoperativeDURING PS-1 CHECK, FOUND FORWARD AMBER EMERGENCY LIGHT FLOOR PROXIMITY STRIP AND SERVICE DOOR SMALL EXIT IDENTIFIER SIGN INOP. C/A-R&R FWD AMBER EMERGENCY LIGHT FLOOR PROXIMITY STRIP, OPC BAD, IAW AMM 33-50-12. REF ITEM 2 OF THIS NRWCSDR RAIA2019100292002Floor Support · crackedMAIN CABIN RH BEAM IS CRACKED AND CORRODED AROUND FASTNER HOLE AT FR 59 & 61....R&R RH OMEGA BEAM FROM FR 58 THRU FR 63.SDR RAIA2019100292001Floor Support · crackedMAIN CABIN CENTER OMEGA BEAM IS CRACKED AND CORRODED AROUND FASTNER HOLE AT FR 59 & 61. R&R CENTER LAV OMEGA BEAM FROM FR 57 THRU FR 62.SDR SIMA20190922001Panel · inoperativeFOUND GALLEY WALL EMERGENCY EXIT PANEL INOP DURING PS1 CHECK. C/A-RAR GALLEY WALL EMERGENCY PANEL EXIT LIGHT IAW AMM 33-50-14. OPS CHECK GOOD.SDR SIMA20190921001Acm · faultyIN CRUISE FLT FL240, FA REPORTED SMOKE IN THE CABIN, FOLLOWED AOM EMERGENCY PRECEDURES, LANDED SAFELY IN TPA. UPON CABIN INSPECTION FOUND SMOKE MARKS BY SEATS 4C, 5C. FA REPORTS SMOKE CAME OUT BY SEATS 3A, 4A.PAX REPORTS VIBRATION BY SEAT 11A. C/A-DURING INSPESDR HNAA2019092500285Relay · faultyNLG DOOR OPENED UNCOMMANDED DURING APPROACH, CREW C/W QRH, NO FURTHER DEFECTS NOTED. FIX: T/S PER FIM SHOWS TRANSITORY CONDITION. CYCLED GEAR SEVERAL TIMES OPS CHECK GOOD PER AMM 32-30-00. NLG DOORS NOT DESIGNED TO INDICATE OPEN OR CLOSE. REPLACED RELAY K0642 SDR HNAA2019092500284Battery · dischargedEMERGENCY LIGHT OUT FROM ROW 8 TO 12. FIX: REPLACED EMERGENCY BATTERY #3 IAW FIM TASK 33-50-00-810-804-A AND IAW AMM 33-50-50, AMM 33-50-04. OPS CHK IAW W/C 33-70-17. OK FOR SERVICE.SDR SIMA20190920001Acm · malfunctionedSMOKE IN FLIGHT DECK LEVEL AT FL250 DIVR JAX ACCT SMOKE IN COCKPIT. EMER DECL. C/A-PERFORMED FIM TASK 21-20-00-810-801-A AND FOUND PACK 1 ACM NOT CYCLING PROPERLY. REF ITEM 2 THIS LG PG FOR PACK 1 DEFERRAL AND PERFORMED ETN-EM-72-034.SDR SIMA20190920002Light · inoperativeRT OVERWING EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED RT OVERWING EMERGENCY LIGHT LAMP IAW AMM 33-50-07. OPS CHECKS GOOD NO FURTHER DEFECTS NOTED.SDR SIMA20190919001Smoke Detector · failedSUPPLEMENTAL LAV SMOKE WARNING IN FLIGHT. C/A-FOLLOWED FIM TASK 26-14-00-810-802-A. FOUND POSSIBLE FAULTY DETECTOR. DEFERRED LAVATORY SMOKE DETECTION SYS. "M" PROCEDURES C/W..MEL# 26-01 AUTH# 090669DM-C. INSPECTED LAVATORY LIGHTS AND BALLAST. RAR COURTESY LIGHSDR RAIA2019100918038Threshold · corrodedMAIN CABIN SERVICE DOOR THRESHOLD HAS CORROSION AROUND NUTPLATE HOLES FROM STA 20 THRU 22-. BEGAN REMOVING SVC DOOR THRESHOLD FASTENERS. REMOVED & BEGAN DRILLING HOLES IN THE SVC DOOR THRESHOLD. BEGAN INSTALLING SVC DOOR THRESHOLD. INSTALLED ALL HI-LOKS & #5 SDR RAIA2019100891837Seat Track · corrodedMAIN CABIN LH OMEGA BEAM SEAT TRACK HAS CORROSION FROM FR 19 THRU 22. R&R SEAT TRACK FROM FR 19 THRU 22.SDR RAIA2019100591836Floor Support · corrodedLH OMEGA BEAM UPPER O/B MATING FLANGE HAS CORROSION ON UPPER SURFACE AT FR 23- REMOVED AND REPLACED L/H MATING FLANGE.SDR RAIA2019100591035Seat Track · corrodedMAIN CABIN CENTER BEAM SEAT TRACK HAS CORROSION AT STA 24 & 26- BLENDED OUT CORROSION DEEPEST AREA WAS .006" FOUND TO BE WITHIN LIMITS, INSPECTED WITH 30X MAG NO FURTHER DAMAGE FOUND.SDR RAIA2019100598034Floor Support · corrodedMAIN CABIN CENTER OMEGA BEAM UPPER RH MATING FLANGE HAS CORROSION ON UPPER SURFACE BETWEEN FR 36 THRU 38- REMOVED MAIN CABIN CENTER OMEGA BEAM UPPER RH MATING FLANGE. REPLACED MAIN CABIN CENTER BEAM UPPER RH MATING FLANGE.SDR RAIA2019100491833Gusset · corrodedMAIN CABIN LH OMEGA BEAM UPPER O/B FLANGE HAS CORROSION AT FRAME 43.5- REMOVED LOWER SCAT TRACK AT FRAME 43.5. REMOVED LH GUSSET AT FRAME 43.5. INSTALLED NEW GUSSET ONTO THE TOP OF THE LEFT HAND OMEGA BEAM BY INSTALLING CHERRY RIVETS AND SOLID RIVETS.SDR RAIA2019100491832Floor Support · corrodedMAIN CABIN LH FLOOR SILL HAS LIGHT CORROSION ON UPPER SURFACE BETWEEN FRAME 19 & 20 LH. REMOVED LH FLOOR SILL AT FRAME 19 & 20 LH. REFAB AND INSTALL LH FLOOR SILL AT FRAME 19 & 20 LH BUT STILL HAVE FEW RIVITS THAT NEED TO BE INSTALLED. INSTALLED MAIN CABIN LHSDR RAIA2019100491831Floor Support · corrodedCENTER OMEGA BEAM RAMP ANGLE CORRODED THRU AT FRAME 20. REMOVED DAMAGED PART, LOCATED 90% OF NEW PART. LOCATED REMAINING HOLES ON RAMP ANGLE AT FR20 & INSTALLED.SDR RAIA2019100498030Floor Support · corrodedCENTER OMEGA BEAM UPPER DIGITAL SUPPORT HAS CORROSION FROM FR 20 THRU 23- REMOVED DAMAGED PART, LOCATED NEW PART. INSTALLED CENTER OMEGA BEAM GUSSET FROM FR20-FR23, THE 4 NUTPLATES NEED TO BE INSTALLED YET. INSTALLED THE 4 NUTPLATES IN CENTER OMEGA BESDR RAIA2019100390029Floor Support · corrodedMAIN CABIN FLOOR SUPPORT STEP UP HAS CORROSION AT STA 23 BETWEEN CENTER OMEGA BEAM & RH FLOOR SILL- R/R FR23 STEP UP ANGLE LOWER SUPPORT FROM CENTER OMEGA BEAM TO RH FLOOR SILL.SDR RAIA201909180028Floor Support · corrodedMAIN CABIN CENTER OMEGA BEAM UPPER DIGITAL SUPPORT BETWEEN FRAME 16 & 18 HAS CORROSION ON UPPER SURFACE- REMOVED 3 SPOTS OF CORROSION OF .002", REMAINING THICKNESS OF .038", NO FURTHER DEFECTS,SDR RAIA2019100391827Floor Support · corrodedMAIN CABIN FLOOR SUPPORT STEP UP HAS CORROSION AT FRAME 18 O/B OF CENTER OMEGA BEAM- R/R THE FLOOR SUPPORT STEP UP ANGLE AT FR18.SDR RAIA2019100291026Floor Support · corrodedMAIN CABIN AFT LAV LH FLOOR SILL HAS CORROSION AT FRAME 61- REMOVED & REPLACED AFT LAV L/H FLOOR SILL AT FR 61.SDR RAIA2019100298025Floor Support · corrodedMAIN CABIN LH FLOOR SILL HAS CORROSION ON UPPER SURFACE FROM STA 23 TRU 28. R&R MAIN CABIN LH FLOOR SILL AT STA 23 THRU 28.SDR RAIA2019100298024Floor Support · corrodedMAIN CABIN FLOOR SUPPORT AT FR 22 BETWEEN CENTER & RH OMEGA BEAM HAS CORROSION ON UPPER SURFACE. R&R DAMAGED FLOOR SUPPORT AT FR 22.SDR RAIA2019100298023Floor Support · corrodedMAIN CABIN RH OMEGA BEAM STOP SIGN HAS CORROSION AROUND NUTPLATE HOLE AT FR 22. R&R STOP SIGN AT FR 22.SDR RAIA2019100298022Floor Support · corrodedMAIN CABIN LH FLOOR SILL HAS CORROSION AT FR 43.5 ON UPPER SURFACE....R&R LH FLOOR SILL AT FR 43.5SDR RAIA2019100298021Floor Support · corrodedRH FLOOR SILL REPAIR DOUBLER HAS CORROSION AROUND FASTNER HOLE AT FR 20 FWD OF SERVICE DOOR. R&R RH FLOOR SILL REPAIR DOUBLER AT FR 20 FWD OF SERVICE DOOR.SDR RAIA2019100291820Floor Support · corrodedMAIN CABIN AFT LAV RH OMEGA BEAM UPPER DIGITAL SUPPORT HAS CORROSION ON UPPER SURFACE UNDER CARBON FIBER RING AT FR 61 & AT FR 59 AROUND NUT PLATE HOLE....R&R R/H OMEGA BEAM GUSSET IN LAV AT FR 59 TO FR 62.SDR RAIA2019100298019Floor Support · corrodedMAIN CABIN AFT LAV CENTER OMEGA BEAM UPPER DIGITAL SUPPORT HAS CORROSION AROUND NUT PLATE HOLE AT FR 59 & UNDER CARBO FIBER RING....R&R OMEGA BEAM GUSSET FROM FR 59 THRU FR 61.SDR RAIA2019100191818Floor Support · corrodedLH OMEGA BEAM PREVIOUS REPAIR DOUBLER HAS CORROSION AT FR 20. R&R CORRODED DOUBLER AT FR 20.SDR RAIA2019100191817Floor Support · corrodedMAIN CABIN LH FLOOR SILL HAVE CORROSION ON UPPER SURFACE AT FR 31 THRU 35. R&R MAIN CABIN L/H FLOOR SILL AT FR 31 THRU 35.SDR RAIA2019100118016Angle · corrodedPASSENGER DOOR THRESHOLD AFT NUTPLATE Z ANGLE HAVE CORROSION. R&R PAX DOOR THRESHOLD AFT Z ANGLE.