Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA2009111700001Cable · out of adjustCREW REPORTED THAT THE MAIN PASSENGER DOOR AS BEING DIFFICULT TO OPEN. MAINTENANCE ADJUSTED THE MAIN DOOR CABLES. OPERATIONALLY CHECKED GOOD AFTER ADJUSTMENT.SDR FDKA2009110900193Acm · malfunctionedFRL FLT 6101 IND-CVG. RTG-NR 1 PACK OVERHEAT ON GRD/BURNING SMELL. MX REPLACED ACM.SDR FDKA2009110900192Light · malfunctionedFREEDOM FLT 6114 FROM MSP TO CVG DURING THE PREFLIGHT THE CREW REPORTED NUMEROUS CABIN EMERGENCY EXIT LIGHTS INOP. CONTRACT RE-TESTED THE LIGHTS AND COULD NOT DUPLICATE THE DISCREPANCY.SDR SIMA200931302Charger · inoperativeDURING MAINTENANCE INSPECTION FOUND THE OVERWING EMERGENCY LIGHTS FLICKER ON/OFF INTERMITTENTLY WITH POWER OFF AND EMERGENCY LIGHT SWITCH NOT ARMED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NUMBER 4 EMERGENCY POWER SUPPLY UNIT ASSEMBLYSDR RAIA2009120200001Battery · looseDURING A SCHEDULED MAINTENANCE INSPECTION, MAINTENANCE REPORTED THAT THE EMERGENCY LIGHT NOT ARMED MESSAGE APPEARED ON THE EICAS. MAINTENANCE RE-SECURED THE NR 3 EMERGENCY LIGHT BATTERY AND PERFORMED AN OPS CHECK OF THE EMERGENCY LIGHTING SYSTEM. OPS CHECKEDSDR RAIA2009112000001Battery · looseDURING SCHEDULED MAINTENANCE AN EMERGENCY LIGHT NOT ARMED MESSAGE WAS DISPLAYED ON THE EICAS. MAINTENANCE INSPECTED THE EMERGENCY LIGHTING SYSTEM AND FOUND THE NR 3 EMERGENCY LIGHT BATTERY LOOSE. THE CONNECTOR WAS RE-SECURED FOLLOWED BY AN OPERATIONAL CHECK SDR CHQA200900242Wire · brokenDURING INSPECTION THE NR 4 FLOOR PROXIMITY LIGHT STRIP WAS FOUND TO HAVE A BROKEN WIRE. MAINTENANCE REPLACED THE #4 PROXIMITY LIGHT STRIP IAW EMB 145 AMM 32-50-12. OPERATIONAL CHECK GOOD.SDR CHQA200900241Relay · faultyDURING CRUISE THE FLIGHT CREW REPORTED THAT THE BAGGAGE SMOKE LIGHT CAME ON AND THE BAGG SMOKE EICAS MESSAGE FLASHED ON AND OFF. THE CREW REPORTED NO INDICATIONS OF HEAT, SMOKE OR FIRE THROUGH THE BAGGAGE COMPARTMENT VIEWER IN THE LAV. THE AIRCRAFT CONTINUEDSDR CHQA200900240Smoke Warning · false activationDURING CRUISE THE FLIGHT CREW REPORTED THAT THE BAGGAGE SMOKE LIGHT CAME ON ALONG WITH A BAGG SMOKE MESSAGE ON EICAS. AFTER A FEW SECONDS THE EICAS MESSAGE CLEARED BUT THE BAGGAGE SMOKE LIGHT REMAINED ON. THE CREW VERIFIED THAT THERE WERE NO INDICATIONS OF SSDR C2XA09CL146Ballast · faultyDAY FLT NR 2875 - THE CREW REPORTED A STRONG ELECTRICAL ODOR/FUMES IN CABIN. THE AIRCRAFT RETURNED TO DAY AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE LIGHT BALLAST AT SEAT 1A. OPERATIONAL CHECKS WERE GOOD.SDR C2XA09IA286Ballast · burnedIAH - FLIGHT 2572, DURING PREFLIGHT THE CREW REPORTED SMOKE/BURNING ODOR WHEN THE FA TURNED ON THE LIGHTS. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE FORWARD GALLEY LIGHT BALLAST, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE AIRCRAFT WASSDR C2XA09SH410Support · corrodedSHV - DURING C-CHECK, LAV WASTE DRAIN VALVE SUPPORT CORRODED. REMOVED AND REPLACED LAV WASTE DRAIN VALVE SUPPORT IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH409Floor Support · corrodedSHV - DURING C-CHECK - LT OMEGA BEAM HAS CORROSION AT FR 29. REPAIRED LT OMEGA BEAM IAW EMB 145 SRM 53-00-10. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH408Floor Support · corrodedSHV - DURING C-CHECK - LT OMEGA BEAM HAS CORROSION AT FR 49-50. REPAIRED LT OMEGA BEAM IAW EC5310-01466 AND EMB 145 SRM 53-00-00. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH407Door Frame · corrodedSHV - DURING C-CHECK, SERVICE DOOR CUTOUT HAS CORROSION UNDER AFT LWR TEFLON GUIDE. REPAIRED SERVICE DOOR CUTOUT IAW ETD2009-145/09007A. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA2009111200004Mechanism · out of adjustCREW REPORTED THAT THE PASSENGER DOOR WAS DIFFICULT TO OPEN AND CLOSE. MAINTENANCE ADJUSTED THE DOOR OPERATING MECHANISM. OPS CHECKED GOOD.SDR SIMA200931303Floor Support · corrodedDURING MAINTENANCE BASE VISIT THE LEFT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 20. THE EXISTING REPAIR WAS FOUND TO BE CORRODED OUT OF LIMITS IAW SRM 53-21-10. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED DOUBLER AND INSTALLED NEW DOUBLER IAW EMB SRM SDR CHQA200900239Fire Loop · faultyDURING CRUISE AT FL330, THE CREW RECEIVED AN EICAS ENG 2 FIRE MESSAGE. THE QRH PROCEDURES WERE FOLLOWED AND THE ENGINE WAS SHUT DOWN. THE AIRCRAFT THEN DIVERTED TO KBUF WHERE THE AIRCRAFT LANDED WITHOUT INCIDENT. FIRE CREWS INSPECTED E2 AND REPORTED NO INDISDR C2XA09IA283Pin · looseIAH - DURING MAINTENANCE INSPECTION THE OVERHEAD EMERGENCY EXIT LIGHT AT ROW 12 WAS FOUND TO BE INOPERATIVE. MAINTENANCE RE-SECURED THE PIN AT SPLICE SP9208, OPERATIONALLY TESTED WITH NO DEFECTS. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA200900238Battery · dischargedDURING INSPECTION, THE EMERGENCY LIGHTS AT THE CEILING PANEL, AISLE LIGHTING, AND AT THE LEFT FORWARD FUSELAGE FAIRING WERE INOP WHEN TESTED. MAINTENANCE REPLACED THE NR 1 EMERGENCY LIGHT BATTERY WITH NO FURTHER DEFECTS NOTED.SDR CHQA200900237Pressure Switch · failedDURING CRUISE THE CREW REPORTED A YAW DAMPER AND AUTO PILOT FAIL FOLLOWED BY RUDDER 1 AND RUDDER 2 FAIL MESSAGES. THE QRH WAS FOLLOWED AND THE YAW DAMP MESSAGE CLEARED BUT THE RUDDER FAIL MESSAGES RETURNED. THE AIRCRAFT DIVERTED TO CMH WHERE IT LANDED WITHOUSDR CHQA200900236Indicator · failedTHE FLIGHT CREW REPORTED THAT AS THE AIRCRAFT ROTATED FOR TAKEOFF, THE INTEGRATED STANDBY INSTRUMENT SYSTEM FAILED. THE AIRCRAFT RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE INTEGRATED STANDBY INSTRUMENT SYSTEM WITH NO FURTHER DEFESDR C2XA09IA280Unknown · odorABQ - FLIGHT 2728, DURING PREFLIGHT INSPECTION THE CREW REPORTED AN ELECTRICAL BURNING SMELL IN THE COCKPIT AND CABIN. CONTRACT MAINTENANCE INSPECTED THE AIRCRAFT ELECTRICAL AND PNEUMATIC SYSTEMS, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE AIRCRAFT WSDR RAIA2009111200002Light · inoperativeDURING THE PRE-FLIGHT INSPECTION, THE CREW REPORTED THAT THE CENTER AISLE EMERGENCY FLOOD LIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BLOWN LIGHT BULB AT THE LIGHT ASSEMBLY. OPS CHECKED GOOD.SDR RAIA2009111200001Connector · dirtyDURING PRE FLIGHT INSPECTION, THE CREW REPORTED ONE OF THE EMERGENCY LIGHTS AS BEING INOPERATIVE. MAINTENANCE CLEANED THE CONNECTOR AT THE AFFECTED LIGHT. OPS CHECKED GOOD.SDR CHQA200900235Inverter · defectiveDURING INSPECTION THE LEFT SIDE EMERGENCY EXIT INTERIOR LIGHT WAS FOUND TO BE INOP. THE NR 4 EMERGENCY LIGHT INVERTER WAS REPLACED IAW AMM 33-50-11, WITH NO FURTHER DEFECTS NOTED.SDR CHQA200900234Engine · bird ingestionTHE FLIGHT CREW REPORTED THAT ON TAKEOFF, HAD A SMOKE SMELL IN THE CABIN AND COCKPIT WITH NO VISIBLE SMOKE. THE SMELL CLEARED AFTER TWO MINUTES AND THE AIRCRAFT CONTINUED ITS FLIGHT WITHOUT INCIDENT. MAINTENANCE IN GSO INSPECTED THE AIRCRAFT AND FOUND EVIDENSDR C2XA09CL141O-Ring · faultyEWR FLT 2940 - THE CREW REPORTED A BLD 2 LEAK ON CLIMBOUT. MAINTENANCE INSPECTED AND REPLACED THE O-RINGS ON THE NR 2 BLEED DUCT IN THE CARGO COMPARTMENT JOINT NR 20. OPERATIONAL CHECKS WERE GOOD.SDR SIMA200930601Sealant · damagedON FLIGHT 3695 THE CREW REPORTED THAT ON APPROACH, HAD A FUEL SMELL IN THE COCKPIT. THE AIRCRAFT WAS REMOVED FROM SERVICE. RESEALED BOLT AT FRONT SPAR JUST INBOARD OF RIB 1 LEFT CENTER TANK. REFERENCE EMB 145 SRM 51-20-01. LEAK CHECK GOOD IAW AMM 28-11-00.SDR C2XA09SH394Mount · corrodedSHV - DURING C-CHECK RT ENGINE FRONT MOUNTING FLANGE HAS ON CORRODED (LEVEL 2 LOCAL) BOLT HOLE. MAINTENANCE CLEANED, REAMED AND POLISHED ONE CORRODED HOLE AT RT ENGINE FRONT MOUNTING FLANGE IAW EMB-145 RR AE3007A; 72-25-30. THE AIRCRAFT WAS APPROVED FOR RETUSDR C2XA09SH393Mount · corrodedSHV - DURING CHECK LT ENG FRONT MOUNTING FLANGE HAS 24 CORRODED (LEVEL 2 LOCAL) BOLT HOLES. MAINTENANCE CLEANED, REAMED AND POLISHED UP TO 0.306 CORRODED HOLES AT 24 LT ENG MOUNTING FLANGE BOLT HOLES IAW EMB-145 RR AE3007A; 72-25-30. THE AIRCRAFT WAS APPROVESDR C2XA09SH391Floor Support · corrodedSHV - DURING C-CHECK LT OMEGA BEAM CORRODED (LEVEL 2 LOCAL) BETWEEN FRAMES 58-59. MAINTENANCE PERFORMED REPAIR OF LT OMEGA BEAM BETWEEN FRAMES 58-59 IAW EC5310-01466. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH390Floor Support · corrodedSHV - DURING C-CHECK CENTER OMEGA BEAM AT FRAME 39 CORRODED (LEVEL 2 LOCAL). MAINTENANCE REPAIRED CENTER OMEGA BEAM AT FRAME 39 IAW EMB-145 SRM 53-00-10. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH389Floor Support · corrodedSHV - DURING C-CHECK LT OMEGA BEAM CORRODED (LEVEL 2 LOCAL) AROUND CARBON CROSSBEAM FR 54. MAINTENANCE PERFORMED REPAIR OF LT OMEGA BEAM AT FR 54 IAW EMB-145 SRM 53-00-10 FIG 202 DET A. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09RI187Sign · inoperativeRIC MX - DURING ROUTINE MAINTENANCE, MX FOUND EXIT SIGN IN FRONT OF SEAT 3B INOPERATIVE. MX REMOVED AND REPLACED EXIT SIGN AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR SIMA200930603Angle · crackedDURING MAINTENANCE CHECK FOUND THE LEFT OVERWING PANEL LOWER MOUNT BRACKET NUMBER 2 CRACKED. THE AIRCRAFT HAS BEEN REMOVED FROM SERVICE. REMOVED AND REPLACED NEW LEFT OVERWING PANEL LOWER MOUNT BRACKET NUMBER 2 IAW EMB SRM 51-40-02. THE AIRCRAFT WAS RETURNESDR SIMA200930604Angle · crackedDURING MAINTENANCE CHECK FOUND THE LEFT PANEL LOWER MOUNT BRACKET NUMBER 3 CRACKED. THE AIRCRAFT HAS BEEN REMOVED FROM SERVICE. REMOVED AND REPLACED NEW LEFT OVERWING PANEL LOWER MOUNT BRACKET NUMBER 3. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR SIMA200930602Skin · crackedDURING MAINTENANCE CHECK FOUND THE RIGHT OVERWING PANEL AFT BRACKET SKIN CRACKED. THE AIRCRAFT HAS BEEN REMOVED FROM SERVICE. REPAIRED THE RIGHT OVERWING PANEL AFT BRACKET IAW SRM 53-23-12 AND 51-40-02. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR C2XA09IA277Pump · leakingIAH - FLIGHT 2363 THE CREW REPORTED THAT THE NUMBER ONE HYDRAULIC SYSTEM FAILED ON TAXI. THE AIRCRAFT WAS SHUTDOWN AND TOWED TO THE GATE WHERE MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE ENGINE DRIVEN HYDRAULIC PUMP, SERVICED HYDRAULICS, OPERATIONALLY / LSDR C2XA09IA276O-Ring · blownIAH - FLIGHT 2617 THE CREW REPORTED A BLEED ONE LEAK IN CLIMB. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE BLEED O-RINGS IN THE LEFT CARGO WALL AT LOCATION 19, OPERATIONALLY AND LEAK CHECKED WITH NO DEFESDR FDKA2009102800191Engine · malfunctionedFRL FLT 6216 CLT-HOT. RTF-EMERG DECLARED ENGINE 2 OUT EICAS. MX REPLACED ENGINE, OPS GOODSDR C2XA09CL139Switch · inoperativeCLE FLT 2580 - THE CREW REPORTED A BLEED 1 VALVE CLOSED MESSAGE AFTER TAKEOFF. COULD NOT GET THE NR 1 BLEED VALVE TO OPEN. MAINTENANCE INSPECTED AND REPLACED THE NR 1 BLEED VALVE PUSH BUTTON SWITCH. OPERATIONAL CHECKS WERE GOOD.SDR CHQA200900231Proximity Switch · damagedAFTER ROTATION THE CREW RECEIVED A LANDING GEAR AIR/GROUND FAIL MESSAGE FOLLOWED BY A REVERSE DISAGREE MESSAGE. THE CREW FOLLOWED THE QRH AND RETURNED TO FIELD. THE AIRCRAFT LANDED WITHOUT INCIDENT AND THE AIR/GROUND MESSAGE CLEARED ON LANDING. MAINTENANCE SDR C2XA09IA273Proximity Switch · inoperativeIAH - FLIGHT 2561, THE CREW REPORTED THAT THE NOSE LANDING GEAR DOOR OPENED IN FLIGHT. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE NOSE LANDING GEAR DOOR SEQUENCE PROXIMITY SWITCH, OPERATIONALLY TESTED SDR C2XA09IA272Sealant · odorIAH - FLIGHT 2886, THE CREW REPORTED A BURNING SMELL WHILE TAXIING IN AND WAS STRONGER IN INTENSITY AS THE PARKING BRAKE WAS SET, AND WAS FOUND TO BE STRONGER IN THE MAIN CABIN DOOR / GALLEY AREA. MAINTENANCE INSPECTED THE AIRCRAFT AND FOUND THE SMELL TO BE CSDR C2XA09TY265Battery · dischargedTYS - A/C WAS IN FOR A SERVICE CHECK WHEN INSPECTION FOUND THE AED DEFIBRILLATOR BATTERY INOP. MAINTENANCE REMOVED AND REPLACED THE AED DEFIBRILLATOR BATTERY IAW EC 2560-01065. A/C RELEASED BACK TO SERVICE.SDR C2XA09TY264Bracket · corrodedTYS - A/C CURRENTLY IN C-CHECK WHEN INSPECTION FOUND BOTH LEFT AND RIGHT AILERON PCA BRACKETS CORRODED AND MIGRATED HAT BUSHIONS. MAINTENANCE REMOVED AND REPLACED BOTH AILERON PCA BRACKETS IAW EC5750-01177. ALL WORK WAS ACCOMPLISHED AND OPS CHECK GOOD AND WISDR SIMA200930002Power Supply · dischargedDURING MAINTENANCE INSPECTION FOUND THAT THE RIGHT SIDE OF THE AIRCRAFT FORWARD EMERGENCY LIGHT WOULD NOT COME ON. AIRCRAFT REMOVED FROM SERVICE. REPLACED BATTERY PACK POWER SUPPLY NR 2 IN ACCORDANCE WITH EMB AMM 33-50-04. OPERATIONAL CHECK GOOD. THE AIRCRSDR SIMA200930001Power Supply · dischargedDURING MAINTENANCE INSPECTION FOUND THAT THE LEFT SIDE OF AIRCRAFT FORWARD EMERGENCY LIGHT WOULD NOT COME ON. AIRCRAFT REMOVED FROM SERVICE. REPLACED BATTERY PACK POWER SUPPLY NR 1 IN ACCORDANCE WITH EMB AMM 33-50-09. OPERATIONAL CHECK GOOD. THE AIRCRAFT WSDR SIMA200929908Switch · malfunctionedON FLIGHT 3891 RIGHT AFTER TAKEOFF THE CREW REPORTED RECEIVED A LANDING GEAR/LEVER DISAGREE WARNING. THE LANDING GEAR WOULD NOT RETRACT. THE AIRCRAFT RETURNED TO ORD AND LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. AFTER RESETTING THE OV
Back to Embraer EMB-145LR