Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA07RI019Inverter · inoperativeRIC - MX - DURING ROUTINE MAINTENANCE, RIC MX FOUND EMERGENCY EXIT SIGN INOPERATIVE. MX REMOVED AND REPLACED BATTERY INVERTER. MX PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR FDKA200704171Power Supply · inoperativeFDM 6206 JFK-MHT (1014 PHX LCL) - EMERGENCY EXIT DOOR LIGHT INOP. MX REMOVED AND REPLACED NR 3 POWER SUPPLY.SDR SIMA200712004Clamp · missingRECEIVED ENGINE ONE ATTCS NO MARGAIN AND EXCEEDANCE ON TAKEOFF, LOW SPEED ABORT. INSTALLED NEW V-BAND CLAMP ON LEFT UPPER COMPRESSOR BLEED LINE IAW ROLLS ROYCE MM 75-31-00. LEAK CHECK GOOD, RETURNED AIRCRAFT TO SERVICE.SDR RAIA00704073Inverter · inoperativePOST FLT NR 5568 - STL - EMERGENCY LIGHT AFT CEILING EXIT LOCATOR IS OUT. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT INVERTER OPS CHECK GOOD.SDR FDKA200704162Cam · lack of lubeFDM 6053 PHF-ATL (0615 PHX LCL). MAIN PASSENGER DOOR IS HARD TO OPEN AND CLOSE. MX LUBED CAM, DOOR SEAL.SDR C2XA07IA096Apu · leakingJAN - FLIGHT 2395, THE CREW REPORTED SMOKE IN THE COCKPIT AND CABIN WITH THE APU RUNNING. CONTRACT MAINTENANCE INSPECTED THE AIRCRAFT, AND PLACED THE APU ON MEL 49-00-00, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. THE AIRCRAFT RETURNED TO IAH ON 04SDR SIMA200712005Inverter · burnedSTRONG ELECTRICAL ODOR FOR ONE MINUTE AND THEN DISSIPATED. REMOVED AND REPLACED NR 1, NR 2 RECIRCULAR FANS AND NR 1 RECIRCULAR FAN INVERTER IAW EMB AMM. OPERATIONAL CHECK GOOD. RETURNED AIRCRAFT TO SERVICE.SDR SIMA200712006Adc · failedNUMBER ONE AIR DATA COMPUTER FAILURE, DIVERTED TO LRD. PERFORMED PITOT LEAK CHECK IAW EMB AMM 34-13-00 WITH NO DEFECTS. OPERATIONAL CHECK GOOD IAW EMB AMM 34-15-00. RETURNED AIRCRAFT TO SERVICE.SDR SIMA200712003Unknown · vibrationVIBRATION FELT INFLIGHT BETWEEN ROW 3 AND ROW 7.SDR RAIA00704072Light · inoperativePRE FLT NR 7884 - ORD - EMERGENCY LIGHT OUT ABOVE 3A. MAINTENANCE RELAMPED, OPS CHECK GOOD ON GROUND.SDR C2XA07IA095Unknown · odorIAH - FLIGHT 2824, THE CREW REPORTED A 115VAC OFF BUSS INDICATION WITH A BURNING SMELL IN THE COCKPIT. MAINTENANCE INSPECTED THE AIRCRAFT AND COULD NOT DUPLICATE ANY DISCREPANCY, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA200700011Engine · smokeFLIGHT 6240, LAVATORY SMOKE DURING TAKEOFF. MAINTENANCE REMOVED AND REPLACED NR 2 ENGINE. NO SMOKE DURING OPS CHECK.SDR RAIA00704069Light · loosePOST FLT NR 7968 - ORD - EMERGENCY LIGHT LEFTHAND OVERWING EXIT MARKER. MAINTENANCE RESECURED LIGHT ASSY. OPS CHECK GOOD.SDR RAIA00704071Dau · malfunctionedFLT NR 5527 - STL - AT FL290, 115VAC BUSS OFF LINE, BLEED 1 LOW TEMP, BATT 2 OVERTEMP, LOW O2 WARNING, DASHED LINES APPEARED ON OXY PRESSURE / TEMP. MAINTENANCE REMOVED AND REPLACED NR 1 DAU CHECK GOOD.SDR C2XA07IA094Warning System · malfunctionedICT - FLIGHT 2725, THE CREW REPORTED AN ELEC EMERGENCY ABNORMAL MESSAGE ON EICAS DURING CLIMB. THE CREW PERFORMED AN EMERGENCY DESCENT, AND LANDED AT ICT WITHOUT INCIDENT. THE CREW RESET THE AIRCRAFT POWER AND VERIFIED NORMAL OPERATIONS, MX VERIFIED THAT LANSDR RAIA00704068Solenoid · malfunctionedFLT NR 5533-STL-NOISE FROM NOSE GEAR. MAINTENANCE REMOVED AND REPLACED LANDING GEAR SOLENOID VALVE. LEAK AND OPS CHECK GOOD.SDR RAIA00704065Unknown · unknownFLT NR 5506 - STL - DUAL PITCH TRIM FAIL IN-FLIGHT. MAINTENANCE RESET A/C POWER PERFORMED GROUND OPS CHECK ON MAIN AND BACK-UP PITCH TRIM SYSTEM. OPS CHECK GOOD.SDR SIMA200711402Engine · vibrationENGINE TWO ON START VIBRATIONS INCREASED BETWEEN 35 TO 40 PERCENT, N1 REMAIN IN GREEN BAND. REMOVED AND REPLACED NUMBER TWO ENGINE IAW AMERICAN EAGLE WORK CARD. OPERATIONAL AND LEAK CHECK GOOD. RETURNED TO SERVICE.SDR FDKA200704174Buttstrap · corrodedCENTER BUTT STRAP BETWEEN FRAME 15 TO JUST AFT OF FRAME 16 IS CORRODED BEYOND ALLOWABLE LIMITS. DAMAGE WAS REPAIRED.SDR FDKA200704173Angle · corrodedFLOOR CROSSBEAM ANGLE, ABOVE FRAME 23, JUST TO THE RIGHT OF THE CENTER LINE IS CORRODED BEYOND ALLOWABLE LIMITS. REMOVED AND REPLACED CROSSBEAM ANGLE.SDR FDKA200704160Mechanism · lack of lubeFDM 6108 MCO-HSV (1123 PHX LCL). SERVICE DOOR WOULD NOT CLOSE. MX LUBED DOOR AND OPS CHECKED.SDR RAIA00704063Carbon Seal · leakingFLT NR 8012-ORD-ENGINE NR 1 LOW OIL PRESSURE EICAS MESSAGE ENGINE NR 1 QUANITY LOW. MAINTENANCE REMOVED AND REPLACED NR 1 GENERATOR CARBON SEAL. NO LEAKS NOTED AT THIS TIME.SDR RAIA00704064Bulb · burned outPRE FLT NR 5576 - STL - AFT FLOOD LIGHT INOP. MAINTENANCE RELAMPED FLOOD LIGHT, OPS CHECK GOOD.SDR C2XA07RI018Smoke Detector · inoperativeFLIGHT 2882 - EWR - CREW REPORTED NR 2 CARGO SMOKE DETECTOR INOP. EWR MX REMOVED AND REPLACED NR 2 CARGO SMOKE DETECTOR IAW EMB AMM 26-23-00. MX PERFORMED OPS CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR RAIA00704062Control Unit · malfunctionedFLT NR 7890-ORD-OUTBOARD BRAKES INOP MESSAGE ON EICAS. MAINTENANCE REPLACED BRAKE CONTROL UNIT CHECK GOOD.SDR RAIA00704061Seal · blownFLT NR 8034 - IAD - ENGINE 2 BLEED LEAK CLIMING THRU 15000' PASSENGERS IN REAR OF A/C ON RIGHT SIDE REPORTED LOUD BANG FOLLOWED BY WHOOSHING AIR SOUND. MAINTENANCE REPLACED O-RINGS AND RECONNECTED DUCT COUPLING, OPS NORMAL .SDR FDKA200704172Floor Support · corrodedRT DIGITAL BETWEEN FRAME 58 AND 60 IS CORRODED OUT OF LIMITS. THE DAMAGED PART WAS REMOVED AND REPLACED.SDR C2XA07RI022Solenoid Valve · defectiveFLT 2745 - EWR - CREW REPORTED AT FL 350, SMOOTH AIR QUICK OPEN AND CLOSING SOUNDS COMING FROM NOSE WHEEL DOORS WERE AUDIBLE FROM COCKPIT AND FRONT CABIN. SOUND OCCURRED ABOUT SIX TIMES. EWR MX REMOVED AND REPLACED SOLENOID VALVE. MX PERFORMED LEAK CHECK ANSDR RAIA00704054Bulb · loosePOST FLT NR 5524 - STL - EMERGENCY LIGHT BULB ON STRIP AISLE FLOOD LIGHT IS INOP. MAINTENANCE RESEATED LIGHT BULB.SDR SIMA200712818Sill · corrodedCARGO DOOR SILL FOUND CORRODED. REMOVED AND REPLACED SILL IAW EMB EMB SRM 51-40-02. RETURNED AIRRAFT TO SERVICE.SDR RAIA00704052Light · loosePOST FLT NR 8090 - IAD - EMERGENCY LIGHT AT RIGHT OVERWING EXIT IDENTIFIER INOP. MAINTENANCE ADJUSTED EMERGENCY EXIT LIGHT AT RIGHT SIDE OVERWING EXIT. OPS CHECK GOOD.SDR SIMA200711007Wire · brokenFOUND EXIT ROW OVERHEAD SIGN WILL NOT TEST. REPAIRED BROKEN WIRE IAW EMB AWM 20-21-00. OPERATIONAL CHECK GOOD, RETURNED AIRCRAFT TO SERVICE.SDR SIMA200711011Rib · dentedBIRD STRIKE INSPECTION REVEALED DENT AFT OF FRAME 10 BETWEEN STRINGER 2R AND CENTER LINE ABOVE WINDOW. REMOVED AND REPLACED RIB AT FRAME 10 ABOVE WINDOW IAW EMB SRM 51-40-02. RETURNED AIRCRAFT TO SERVICE.SDR FDKA200704158A/C Pack · odorFDM 6052 HSV-MCO. SMOKE SMELL COMING FROM PACK 1. MX TROUBLESHOT AND OPS CHECKED GOOD, NO DEFECTS NOTED.SDR FDKA200704157Control Unit · malfunctionedFDM 6017 MCO-BNA (2040 PHX LCL). FLAP LOW SPEED MESSAGE. MX REMOVED AND REPLACED FECU & RELAYS OPS CHECK GOOD.SDR C2XA07IA114Battery Pack · dischargedBNA - DURING MAINTENANCE INSPECTION THE NUMBER TWO EMERGENCY LIGHT BATTERY WAS FOUND TO BE NOT HOLDING A CHARGE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BATTERY PACK, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERSDR SIMA200712823Profile · damagedSERVICE DOOR SURROUND PROFILE AT STRINGER 9R FORWARD AND AFT WAS DAMAGED. REMOVED AND REPLACED PROFILE IAW EMB SRM 51-20-03 AND 51-40-02. RETURNED AIRCRAFT TO SERVICE.SDR SIMA200712821Profile · damagedSERVICE DOOR SURROUND PROFILE AT STRINGER 13R WAS DAMAGED. REMOVED AND REPLACED PROFILE IAW EMB SRM 51-20-03 AND 51-40-02. RETURNED AIRCRAFT TO SERVICE.SDR SIMA200712822Profile · damagedSERVICE DOOR SURROUND PROFILE AT STRINGER 11R WAS DAMAGED. REMOVED AND REPLACED PROFILE IAW EMB SRM 51-20-03 AND 51-40-02. RETURNED AIRCRAFT TO SERVICE.SDR SIMA200712819Profile · damagedSERVICE DOOR SURROUND PROFILE AT STRINGER 7R WAS DAMAGED. REMOVED AND REPLACED PROFILE IAW EMB SRM 51-20-03, 51-40-02 AND 51-40-02. RETURNED AIRCRAFT TO SERVICE.SDR RAIA00704048Light · inoperativePRE FLT NR 5493 - STL - EMERGENCY LIGHT ON HAND RAIL HINGE OF AIRSTAIRS INOP. MAINTENANCE DEFERRED LIGHT PER MEL.SDR RAIA00704047Connector · loosePRE FLT NR 8018 - STL - EMERGENCY LIGHT INOP AT RIGHT ROW SIDE WALL POSITION. MAINTENANCE RESECURED CONNECTORS, OPS CHECK GOOD.SDR FDKA200704154Placard · missingFDM 6148 MCO-MIA (0354 PHX LCL). FWD & AFT EMERGENCY FLASHLIGHT M106 STICKERS MISSING. MX INSPECTED AND REPLACED STICKERS.SDR C2XA07RI017Flex Duct · damagedFLT 2987 - EWR - FLIGHT ATTENDANT REPORTED SMOKE IN THE CABIN COMING FROM FLOOR VENT BETWEEN ROWS 9-11. EWR MX FOUND NR 1 PACK DUCT TO BE OFF RECIRCULATE FAN AND TO BE DAMAGED. MX REMOVED AND REPLACED DUCT IAW EMB 145 MM 21-20-04. MX PERFORMED OPERATIONAL CSDR C2XA07SH020Floor Support · corrodedSHV - DURING C-CHECK MAINTENANCE FOUND CORROSION ON THE I/B SIDE & FLANGE OF THE LEFT OMEGA BEAM AT FRM 20. MAINTENANCE REPAIRED LEFT OMEGA BEAM AT FRM 20 IAW EMB 145 SRM 53-00-10. AIRCRAFT WAS APPROVED TO RETURN FOR SERVICE.SDR C2XA07SH022Fitting · corrodedSHV - DURING C-CHECK MAINTENANCE FOUND CORROSION ON SHEAR CLIPS AT FRAMES 65 & 68. MAINTENANCE REPAIRED SHEAR CLIPS AT FRAMES 65 & 68 IAW EC 5330-01458. AIRCRAFT APPROVED FOR RETURN TO SERVICE.SDR C2XA07SH021Firewall · chafedSHV - DURING C-CHECK MAINTENANCE APU FIREWALL LOWER SECTION HAS RIVET INDENTATION. MAINTENANCE REPAIRED APU FIREWALL AT FRAME 81 LOWER SECTION IAW EC5310-01359. THE AIRCRAFT WAS APPROVED TO RETURN FOR SERVICE.SDR RAIA00704045Unknown · odorFLT NR 8059 - RIC - RUBBER BURNING ODOR REPORTED FROM PAX IN ROW 18. MAINTENANCE PERFORMED INSP OF ALL EMERGENCY LIGHTS & BLEED DUCTS, RAN APU, ENGINES AND PACKS NO DEFECTS OR SMELLS NOTED AT THIS TIME.SDR FDKA200704156Light · inoperativeFDM 6017 (1919 PHX LCL). RT OVERWING EXIT LIGHT INOP. MX RESET SYSTEM OPS GOOD.SDR FDKA200704155Light · inoperativeFDM 6100 (0630 PHX LCL) . EMERGENCY EXIT FLOOR LIGHTING INOP. MX PERFORMED OPS CHECK OF THE FLOOR LIGHTS AND OPS CHECK NORMAL.
Back to Embraer EMB-145LR