SDR C2XA07IA077Apu · odorSTL - FLIGHT 3153, DURING PREFLIGHT INSPECTION THE CREW REPORTED A SMOKEY ODOR IN THE GALLEY. MAINTENANCE INSPECTED THE AIRCRAFT AND PLACED THE APU ON MEL 49-00-00 CAT C CONTROL 118810, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. 10-9-07 ON 04/05/SDR C2XA07TY017Skin Panel · crackedTYS - MAINTENANCE FOUND A CRACK IN THE FUSELAGE AT FR 77, FR 78 AND FR 79 AT STRINGER 6L. MAINTENANCE REMOVED THE DAMAGED SKIN, FAB A DOUBLER, ALODINED AND REINSTALLED. ALL WORK WAS ACCOMPLISHED IAW EC5330-01680. AIRCRAFT RELEASED BACK TO SERVICE.SDR FDKA200704163Threshold · corrodedANGLES AT PASSENGER DOOR THRESHOLD ARE CORRODED OUT OF LIMITS. REMOVED AND REPLACED ANGLES WITH NEW PARTS.SDR FDKA200704165Sill · corrodedSERVICE DOOR IS CORRODED OUT OF LIMITS AT FRAME 19 & 20. INSTALLED REPAIRS.SDR C2XA07RI012Unknown · odorFLT 2335 - CREW REPORTED BURNING SMELL WHEN ANTI-ICE SYSTEM WAS ON IN ICING. MX RAN BOTH ENGINES, WITH ANTI ICE SYSTEM ON AND COULD NOT DUPLICATE THE SMELL. AC WAS APPROVED TO RETURN TO FLIGHT.SDR RAIA00704005Wire · unsecurePOST FLT NR 5574 - STL - EMERGENCY LIGHT FLOOR STRIP AT ROW 11 OUT. MAINTENANCE RESECURED WIRING TO FLOOR STRIPS AT ROW 11, OPS CHECK GOOD.SDR RAIA00704003Handle · out of adjustPRE FLT 8034 - IAD - PAX DOOR INTERNAL HANDLE HARD TO OPERATE. MAINTENANCE ADJUSTED MAIN DOOR STEPS DOOR, OPS CHECK GOOD.SDR RAIA00704001Unknown · unknownPRE FTL 5579 - STL - EMERGENCY LIGHTS COCKPIT STEP EXIT IDENTIFIER AND FWD CEILING EXIT LOCATOR ARE INOP. MAINTENANCE RESET POWER TO SYSTEM, OPS CHECK EMERGENCY LIGHT SYSTEM GOOD.SDR SIMA200709201Carbon Seal · failedNUMBER 2 ENGINE OIL QUANTITY DROPPED TO 4 QUARTS, OIL PRESSURE STARTED TO DROP. CREW SHUTDOWN ENGINE. DIVERTED TO CID. POSTFLIGHT INSPECTION REVEALED OIL ON NUMBER 2 ENGINE COWL. REMOVED AND REPLACED NUMBER 4 GENERATOR AND CARBON SEAL ASSEMBLY PER EMB AMM SDR RAIA00703081Connector · wornFLT 5576 - RIC - ON GEAR RETRACTION, AIR/GROUND C/B POPPED. VARIOUS EICAS WARNINGS. MAINTENANCE REMOVED AND REPLACED THE CONNECTOR ON NOSE GEAR WOW PROX SWITCH.SDR RAIA00703078Lamp · loosePOST FLT 7931 - ORD - LEFT FWD WING/FUSELAGE FAIRING EXTERIOR FLOOD LIGHT IS INOP. MAINTENANCE RESECURED LAMP, OPS CHECK GOOD.SDR RAIA00703079Bulb · burned outPRE FLT 7911 - MSN - EMERGENCY LIGHT ON PLUG DOOR HINGE IS OUT. MAINTENANCE REPLACED BULB, OPS CHECK GOOD.SDR RAIA00703082Connector · loosePRE FLT NR 5587 - STL - EMERGENCY LIGHT AFT CEILING EXIT LOCATOR AND AISLE FLOOD LIGHT ARE INOP. MAINTENANCE RESEATED CONNECTOR TO CEILING LIGHT PANEL, OPS CHECK GOOD.SDR FDKA200703147Sign · unsecureFDM 6040 ATL-PFN (1328 PHX LCL). EMERGENCY EXIT ROW LIGHTED SIGN INOP AT ROW 12. MX SECURED THE SIGN AND OPS CHECK NORMAL.SDR SIMA200708902Valve · failedFLUID STREAMING FROM LEFT WING, RETURNED TO CHA. POST INSPECTION LEFT OUTBOARD WING WET FROM FLUID AND REVEALED FUEL STRAINED AROUND VENT VALVE AND FLAME ARRESTOR. FERRIED AIRCRAFT TO CMI FOR REPAIR. REMOVED AND REPLACED VENT VALVE IAW EMB AMM. OPERATIONALSDR FDKA200700140Warning System · malfunctionedFDM 6000 FLL-MCO (0616 PHX LCL). ABORTED T/O AND RTG DUE TO FUEL 1 AND 2 LOW PSI WARNING MESSAGE. CREW PERFORMED ENGINE RUNS WITH NO DEFECTS NOTED, OPS CHECK NORMAL.SDR SIMA200708901Fan · seizedBURNING ELECTRICAL ODOR IN CABIN AND FLIGHT DECK DURING TAXI OUT, RETURNED TO BLOCK. REMOVED AND REPLACED RECIRCULATION FAN AND PACK VALVE IAW EMB AMM. OPERATIONAL CHECK GOOD, RETURNED AIRCRAFT TO SERVICE.SDR C2XA07TY016Thermal Switch · trippedFLT 2807, F/A NOTED THERMAL SWITCH FOR GALLEY POPPED IN FLIGHT WITH ASSOCIATED BURNING ODOR. AC RELEASED IAW MEL 25-60-02 (3) CAT D.SDR SIMA200708804Bleed Air Sys · leakingLAVATORY SMOKE WARNING MESSAGE ON TAKEOFF WHEN PACKS SELECTED ON, EMERGENCY DECLARED. RETURNED TO ORD. REMOVED AND REPLACED NR 2 ENGINE IAW AMERICAN EAGLE WORK CARD 72-000-00. OPERATIONAL AND LEAK CHECK GOOD. RETURNED AIRCRAFT TO SERVICE.SDR RAIA00703073Connector · dirtyPRE FLT NR 8010 - STL - EMERGENCY LIGHT AT LEFTHAND OVERWING EXIT MARKER IS INOP. MAINTENANCE CLEANED ELECTRICAL CONNECTION AND OPS CHECK GOOD AT THIS TIME.SDR FDKA200703137Seal · looseFDM 6129 RDU-FLL (1441 PHX LCL). GALLEY DOOR WAS SQUEALING IN FLIGHT. MX RE-SECURED THE DOOR SEAL.SDR C2XA07IA074Engine · odorIAH - FLIGHT 2367, THE CREW REPORTED SMOKE IN THE CABIN AND A LAV SMOKE WARNING AFTER T/O. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT, PERFORMED GROUND RUNS AND FOUND THE ODOR TO BE RESIDUAL OIL. THE AISDR FDKA200703136Battery Pack · looseFDM 6163 FLL-PNS (1400 PHX LCL). ROW 12 OVERHEAD EMERGENCY LOCATOR SIGN INOP. MX RE-SECURED BATTERY BACK AT NR 2 POSITION.SDR FDKA200703135Connector · looseFDM 6173 FLL-TLH (0645 PHX LCL). BOTH EMERGENCY DOOR LIGHTS INOP. MX RE-SECURED CONNECTOR ON NR 3 POWER SUPPLY.SDR RAIA00703072Bulb · burned outPOST FLT NR 7886 - IAD - EMERGENCY LIGHT AT MAIN DOOR FLOOD LIGHT IS INOP. MAINTENANCE REPLACED LAMP AT MAIN DOOR, OPS CHECK NORMAL.SDR SIMA200708801Fuel Sys · leakingFOUND FUEL STREAMING FROM WING ON CLIMB-OUT.SDR RAIA00703070Wire · unsecurePRE FLT NR 5564 - STL - EMERGENCY LIGHT AT FLOOR PROXIMITY LIGHT INOP. MAINTENANCE RESECURED WIRING TO FLOOR PROXIMITY LIGHT. OPS CHECK GOOD.SDR C2XA07IA069Engine · leakingIAH - FLIGHT 2978, THE CREW REPORTED THAT ON TOUCHDOWN HAD HEAVY SMOKE IN THE COCKPIT AND CABIN. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED THE NUMBER ONE ENGINE, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURNSDR SIMA200708608Floorbeam · corrodedLEFT OMEGA BEAM CORRODED AT FRAME 20. REPAIRED OMEGA BEAM IAW EMB SRM 53-00-10. RETURNED AIRCRAFT TO SERVICE.SDR C2XA07RI011Relay · inoperativeFLT 2359 - EWR - CREW REPORTED ELECTRICAL EMERGENCY ABNORMAL AND EMERGENCY LIGHT NOT ARMED INDICATIONS CAME ON TAXI. EWR MX REMOVED AND REPLACED RELAY K0097 AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA07IA076Smoke Detector · malfunctionedIAH - FLIGHT 2890, THE CREW REPORTED A LAV SMOKE WARNING FOR 15 SECONDS IN FLIGHT WITH NO VISUAL INDICATION OF SMOKE THROUGHOUT FLIGHT. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE AIRCRAFT, OPERATIONALLY TESTED THE LAV SMOKE DESDR RAIA00703067Light · loosePOST FLT NR 8012 - ORD - FLOOR STRIP EMERGENCY LIGHT LOOSE. MAINTENANCE RESECURED EMERGENCY STRIP LIGHTING AT GALLEY, OPS CHECK GOOD.SDR RAIA00703066Unknown · unknownFLT NR 7901 - ROA - FLIGHT ATTENDANT & PASSENGER REPORTED LARGE STREAM OF VAPOR FROM UNDER WING DURING CLIMBOUT. TANK 2 INDICATION SHOWED GREATER LOSS OF FUEL THAN THE LEFT TANK. MAINTENANCE FUELED AIRCRAFT WITH 11290 LBS AND INSPECTED NO LEAKS NOTED.SDR FDKA200703133Handle · unknownFDM RON CAE. MAIN CABIN DOOR WILL NOT OPEN. MX REINSTALLED THE DOOR HANDLE AND OPS CHECKED.SDR FDKA200703131Unknown · odorFDM 6085 MCO-NAS. SMELL OF SMOKE IN COCKPIT. MX INSPECTED SYSTEMS WITH NO DEFECTS FOUND.SDR C2XA07IA075Inverter · inoperativeMCI - DURING MAINTENANCE INSPECTION AISLE PATH LIGHTS 6, 7 & 8 WERE FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER SIX EMERGENCY LIGHT INVERTER, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA00703065Flap System · unknownFLT NR 3551 - PIT - FLAP FAIL MESSAGE. MAINTENANCE RESET FLAPS AND PERFORMED OPERATIONAL TEST OF FLAP SYSTEM. OPS CHECK GOOD AT THIS TIME.SDR C2XA07IA072Light · inoperativeIAH FLIGHT 2305, DURING POST FLIGHT INSPECTION THE CREW REPORTED THAT THE LAST ROW OF AISLE PATH LIGHTING WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE LAST SECTION OF AISLE PATH LIGHTING, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPSDR C2XA07RI008Inverter · inoperativeEWR - FLT 2882 - DURING PREFLIGHT CHECK, CREW REPORTED GALLEY EMERGENCY EXIT LIGHT INOP. EWR MAINTENANCE REMOVED AND REPLACED NR 3 EMERGENCY LIGHT INVERTER. MX PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO FLIGHT.SDR SIMA200708605Skin · dentedDENT FOUND IN FUSELAGE SKIN AFT OF FRAME 26 AND BETWEEN STRINGERS 20R AND 21R. CUT OUT DAMAGE, FABRICATED AND INSTALLED DOUBLER IAW EMB SRM 51-40-02 AND 53-22-01. AIRCRAFT RETURNED TO SERVICE.SDR RAIA00703061A/C Pack · overheatedFLT NR 7876 - TYS - PACK 2 OVERHEAT. MAINTENANCE DEFERRED NR 2 PACK SYSTEM.SDR FDKA200703145Floorbeam · crackedFLOORBEAM TEE AT FRAME 65 LT SIDE IS CRACKED. THE DAMAGED CROSS FRAME HAS BEEN REMOVED AND REPLACED.SDR FDKA200703146Web · corrodedWEB AT FRAME 22, Y=479R IS CORRODED OUT OF LIMITS. WEB WAS REMOVED AND REPLACED.SDR FDKA200703144Threshold · corrodedCARGO DOOR THRESHOLD IS CORRODED OUT OF LIMITS. THE DAMAGED THRESHOLD HAS BEEN REMOVED AND REPLACED.SDR C2XA07TY015Skin · crackedLEFT FUSELAGE SKIN IS CRACKED AROUND RIVET AT FRAME 77 STR 6L. CUT OUT DAMAGE, INSTALLED FILLER AND DOUBLER. ALODINE PRIMED AND PAINTED IAW EC5330-01676. AIRCRAFT IS STILL IN MOD LINE MAINTENANCE.SDR C2XA07TY014Skin · crackedRIGHT FUSELAGE SKIN CRACKED AROUND RIVET AT FR 79, STR 6R. CUT OUT DAMAGE, INSTALLED FILLER AND DOUBLER. ALODINE PRIMED AND PAINTED IAW EC5330-01676. AIRCRAFT IS STILL IN MOD LINE MAINTENANCE.SDR RAIA00703054Wire · loosePOST FLT NR 5556-STL - EMERGENCY LIGHT AT COCKPIT STEP EXIT IDENTIFIER IS INOP. MAINTENANCE FOUND LOOSE WIRE ON EXIT. REPAIRED WIRE, OPS CHECKED EMERGENCY LIGHTING GOOD.SDR RAIA00703058Connector · loosePOST FLT NR 5566 - STL - EMERGENCY LIGHT INOP AT FLOOR PROXIMITY LIGHT. MAINTENANCE RESEATED CONNECTOR, SYSTEM CHECK GOOD.SDR RAIA00703059Light · malfunctionedPOST FLT NR 5560 - STL - EMERGENCY LIGHT INOP AT GALLEY WALL EXIT LOCATOR. MAINTENANCE CYCLED POWER SYSTEM CHECKED GOOD.SDR RAIA00703057Light · malfunctionedPRE FLT NR 5559 - STL - EMERGENCY LIGHTS FLOOR PROXIMITY LIGHT IS INOP. MAINTENANCE PERFORMED OPS CHECK, NO DISCREPANCY FOUND.
Back to Embraer EMB-145LR