Embraer EMB-145LR

Service difficulty reports · 36,875

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR FDKA200605092Connector · defectiveOVERHEAD EMERGENCY EXIT LIGHTS OVER ROWS 7 TO 10 WERE INOPERATIVE. MAINTENANCE REPLACED THE CONNECTOR STRIPS AND OPS CHECKED.May 14, 2006 · N829MJ · Emb EMB145LR · Emergency LightingSDR RAIA00605031Connector · unsecureMX - STL - WINDOW EXIT EMERGENCY LIGHT INOP. RE-SECURED CONNECTOR AT LIGHT ASSEMBLY.May 14, 2006 · N819HK · Emb EMB145LR · Emergency LightingSDR CHQA200600061Windshield · malfunctionedON DESCENT THROUGH APPROXIMATELY FL270, THERE WAS A SMALL WISP OF SMOKE OBSERVED IN THE COCKPIT. THE SMOKE ORIGINATED FROM BETWEEN THE GLARESHIELD AND THE WINDSHIELD NEAR THE HEATING ELEMENT FOR THE WINDSHIELD. THE AMOUNT OF SMOKE WAS VERY SMALL IN NATURE. May 14, 2006 · N296SK · Emb EMB145LR · Flight Compartment WindowsSDR FDKA200605091Warning System · malfunctionedTHE CREW REPORTED A RUDDER HARD OVER PROTECTION MESSAGE ON EICAS. MAINTENANCE RESET WITH THE CREW.May 13, 2006 · N847MJ · Emb EMB145LR · Rudder Control SystemSDR SIMA200613703Bushing · wornDURING CLIMB, VIBRATION FELT IN YOKE. REPLACED RUDDER BUSHINGS. TRIAD APPROVED. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE. (M)May 13, 2006 · N619AE · Emb EMB145LR · Rudder/Tab, Attach FittingsSDR SIMA200613601Bushing · wornCLIMBING THROUGH 27,000 FT AT .56 MACH VIBRATION IN YOKE WITH OR WITH OUT AUTOPILOT ENGAGED. THROUGH 16,000 FEET AT 250KTS THE VIBRATION SUBSIDED DURING DESCENT. THE VIBRATION SEEMED TO BE ONLY FORWARD TO AFT ON YOKE. CREW TRIED DIFFERENT PITCH SETTINGS WITMay 13, 2006 · N619AE · Emb EMB145LR · Rudder Control SystemSDR RAIA00605030Warning Message · activatedFLT 7989 - IAD - BAG DOOR OPEN INDICATION DURING TAKEOFF ROLL, MAINTENANCE DEFERRED BAG DOOR WARNING SYSTEM PER MEL.May 13, 2006 · N823HK · Emb EMB145LR · Door Warning SystemSDR RAIA00605029Tube · crackedFLT 8016 - OKC - HYDRAULIC SYS NR 1 FAIL. MAINTENANCE REMOVED AND REPLACED NR 1 ENGINE HYD PUMP PRESSURE TUBE.May 13, 2006 · N837HK · Emb EMB145LR · Hydraulic System, MainSDR C2XA06SH057Floor Support · corrodedSHV - DURING C-CHECK THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 20. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM 53-00-10 FIG 201. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.May 13, 2006 · N13970 · Emb EMB145LR · Fuselage Miscellaneous StructureSDR C2XA06SH056Floor Support · corrodedSHV - DURING C-CHECK THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAMES 24 AND 29. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EMB 145 SRM 53-00-10 FIG 201. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.May 13, 2006 · N13970 · Emb EMB145LR · Fuselage Miscellaneous StructureSDR C2XA06SH055Beam · corrodedSHV - DURING C-CHECK THE CARGO DOOR CUTOUT LOWER BEAM WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW CONTINENTAL EXPRESS EC5330-01458. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.May 13, 2006 · N14570 · Emb EMB145LR · Fuselage Miscellaneous StructureSDR C2XA06SH054Firewall · chafedSHV - DURING C-CHECK THE APU FIREWALL WAS FOUND TO BE CHAFED AT THE 6 O`CLOCK POSITION. MAINTENANCE PERFORMED A DOUBLER REPAIR IAW CONTINENTAL EXPRESS EC5310-01359. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.May 13, 2006 · N14570 · Emb EMB145LR · APU Cowling/ContainmentSDR CHQA200600060Carbon Seal · defectiveNORMAL FLIGHT UNTIL CLIMBING THROUGH FL300, NOTICED OIL PRESSURE FOR NR 2 ENGINE WAS IN THE AMBER RANGE ON THE EICAS. CHECKED QUANTITY OF OIL ON NR 2 ENGINE, NOTICED ONLY 3 QUARTS (8 QUARTS OBSERVED DURING AFTER START CHECK). PRESSURE FELL TO 19 PSI IN THE RMay 12, 2006 · N280SK · Emb EMB145LR · Turbine Engine Oil SystemSDR MASA200601319O-Ring · damagedDUAL BLEED LEAK IN ICING CONDITIONS. MX R2 DUCTING O-RINGS.May 12, 2006 · N857MJ · Emb EMB145LR · Pneumatic Indicating SystemSDR C2XA06CL049Light · malfunctionedCLE FLIGHT 2118 THE CREW REPORTED THE AISLE PATH EMERGENCY LIGHT IN REAR WAS NOT WORKING. MAINTENANCE INSPECTED AND RESET THE EMERGENCY LIGHT SYSTEM. OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASED FOR SERVICE.May 12, 2006 · N13914 · Emb EMB145LR · Emergency LightingSDR RAIA00605027Lamp · inoperativeMX - STL - EMERGENCY LIGHT OUT AT 7A. RELAMPED UNIT.May 11, 2006 · N819HK · Emb EMB145LR · Emergency LightingSDR RAIA00605026Warning Light · false activationFLT- 5552- MKE- BLEED NR 2 LEAK INDICATION. MAINTENANCE TROUBLE SHOT AND COULD NOT DUPLICATE MALFUNCTION.May 11, 2006 · N817HK · Emb EMB145LR · Central WarningSDR FDKA200605090Computer · malfunctionedCREW ABORTED TAKEOFF AND REPORTED AN SPS ADVANCE MESSAGE. MAINTENANCE RERACKED THE SPS COMPUTER AND RAN A GOOD SYSTEM CHECK.May 10, 2006 · N825MJ · Emb EMB145LR · Stall Warning SystemSDR SIMA200613203Skin · damagedOIL ACCESS PANEL NR 1 ENGINE IS MISSING, DEPARTED AIRCRAFT INFLIGHT CAUSING A 6-8 INCH TEAR IN NACELLE AND A DENT WITH SEVERAL SCRATCHES. REPLACED ENGINE 1 LOWER COWL AND BLEED AIR DUCT ASSY. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)May 10, 2006 · N682AE · Emb EMB145LR · Nacelle/Pylon, Plate/SkinSDR RAIA00605024Lamp · inoperativeMX - FOUND RIGHT WING EMERGENCY LIGHT INOP. RELAMPED LIGHT UNIT.May 10, 2006 · N812HK · Emb EMB145LR · Emergency LightingSDR RAIA00605023Power Supply · dischargedMX CABIN EMERGENCY LIGHTS INOP. REMOVED AND REPLACED POWER SUPPLY.May 10, 2006 · N815HK · Emb EMB145LR · Emergency LightingSDR RAIA00605022Wire · unsecureMX - EMERGENCY LIGHTS OUT BETWEEN 3A AND 6A. RESECURED CONNECTION STRIP FLOOR LIGHTING.May 10, 2006 · N813HK · Emb EMB145LR · Light System WiringSDR CHQA200600058Bulb · inoperativeFLOOR PROXIMITY LIGHT STRIP INOPERATIVE. REMOVED AND REPLACED FLOOR PROXIMITY LIGHT STRIP. OPS CHECK GOOD.May 10, 2006 · N270SK · Emb EMB145LR · Emergency LightingSDR F06089Light · inoperativeTHE CREW REPORTED THE EMERGENCY EXIT LIGHT 12 A INOP. MAINTENANCE REPLACED THE LIGHT.May 10, 2006 · N830MJ · Emb EMB145LR · Emergency LightingSDR RAIA00605019Bulb · unsecureMX EMERGENCY EXIT SIGN AT ROW 12 INOP. RESECURED BULB.May 9, 2006 · N810HK · Emb EMB145LR · Emergency LightingSDR FDKA200605088Mechanism · lack of lubeTHE CREW REPORTED THAT THE MAIN PASSENGER DOOR WAS HARD TO CLOSE. MAINTENANCE CLEANED AND LUBED DOOR.May 8, 2006 · N829MJ · Emb EMB145LR · Passenger/Crew DoorsSDR FDKA200605087Odor · detectedTHE CREW REPORTED BURNING SMELL IN THE COCKPIT. MAINTENANCE TROUBLESHOT AND OPS CHECKED GOOD.May 8, 2006 · N849MJ · Emb EMB145LR · Air Distribution SystemSDR SIMA200613002Lavatory · warning lightFLT 3665 - TUL - LAVATORY SMOKE DETECTOR LIGHT AND FAINT SMELL IN GALLEY AREA. TROUBLESHOT IAW EMB 145 FIM 21-20-00-810-801. COULD NOT DUPLICATE. A/C OK FOR SERVICE. PERFORMED ENGINE RUNS AND LEAK CHECK. (M)May 8, 2006 · N932AE · Emb EMB145LR · Smoke DetectionSDR RAIA00605017Connector · unsecureMX - FOUND EMERGENCY FLOOR LIGHTS OUT 3A-6A. RESECURED CONNECTION AT ESCAPE PATH LIGHTING STRIP.May 8, 2006 · N813HK · Emb EMB145LR · Light System WiringSDR RAIA00605018Heater · inoperativeFLT 8020 - STL - TAT NR 2 HEAT INOP. MAINTENANCE REMOVED AND REPLACED NR 2 TAT PROBE.May 8, 2006 · N839HK · Emb EMB145LR · Pitot/Static Anti-Ice SystemSDR F06086Light · inoperativeTHE CREW NOTED THE SIDEWALL EMERGENCY LIGHT INOP. MAINTENANCE REPLACED THE LIGHT.May 8, 2006 · N834MJ · Emb EMB145LR · Emergency LightingSDR MASA200601283Light · inoperativeEMERGENCY EXIT LIGHT ROW 12 INOP. MAINTENANCE OP'S CHECKED. OP'S CHECK GOOD.May 8, 2006 · N837MJ · Emb EMB145LR · Emergency LightingSDR CHQA200600055Light · inoperativeEXIT AISLE FLOOR PROXIMITY LIGHT STRIP INOPERATIVE. REMOVED AND REPLACED FLOOR PROXIMITY LIGHT STRIP IAW EMB 145 MM 33-50-02.May 8, 2006 · N267SK · Emb EMB145LR · Emergency LightingSDR FDKA200605085Trim Switch · obstructedTHE CREW REPORTED THE AILERON ROLL TRIM SWITCH STUCK IN FULL RIGHT POSITION. MAINTENANCE REMOVED FOD AND OPS CHECKED GOOD.May 7, 2006 · N849MJ · Emb EMB145LR · Aileron Control SystemSDR SIMA200613501Fadec · malfunctionedDURING TAKEOFF, CREW NOTED THE AIRCRAFT SHUDDERED WHEN CLIMB THRUST SELECTED AFTER TAKEOFF. REPLACED FADEC 1A AND 1B IAW AMM. PASSED FCF. AIRCRAFT RETURNED TO SERVICE. (M)May 7, 2006 · N657AE · Emb EMB145LR · Engine ControlsSDR MASA200601279Stall Warning · no testSPS 1 AND 2 PUSHER INOPERATIVE DURING STALL TEST. MOC RESET WITH THE CREW.May 7, 2006 · N851MJ · Emb EMB145LR · Stall Warning SystemSDR MASA200601280Battery · inoperativeEMERGENCY LIGHTS ARE INOPERATIVE. MX REPLACED THE BATTERIES.May 7, 2006 · N845MJ · Emb EMB145LR · Emergency LightingSDR RAIA00605015Connector · damagedMX - EMERGENCY PATH LIGHTS CENTER AREA INOP. REPAIRED CONNECTOR FLOOR LIGHT STRIP AT 12A.May 7, 2006 · N816HK · Emb EMB145LR · Emergency LightingSDR RAIA00605013Connector · looseMX - EMERGENCY EXIT LIGHT OUT AT 12C. CLEANED AND RE-INSTALLED CONNECTOR.May 7, 2006 · N812HK · Emb EMB145LR · Light System WiringSDR RAIA00605012Connector · looseMX - ROW 12 EMERGENCY LIGHT STRIP INOP. RE-SECURED CONNECTORS AT FLOOR STRIP LIGHTING.May 7, 2006 · N815HK · Emb EMB145LR · Light System WiringSDR C2XA06IA073Inverter · inoperativeSTL - DURING MAINTENANCE INSPECTION, THE EMERGENCY EXIT LIGHT AT THE OVERWING EXIT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NUMBER FIVE EMERGENCY LIGHT INVERTER, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FORMay 6, 2006 · N12540 · Emb EMB145LR · Emergency LightingSDR F06084Light · inoperativeTHE CREW REPORTED THE LT LOWER EMER EXIT LIGHT INOP. MAINTENANCE OPS CHECK THE SYSTEM GOOD.May 6, 2006 · N842MJ · Emb EMB145LR · Emergency LightingSDR FDKA200605083Trim Switch · dirtyTHE CREW REPORTED THE BACKUP PITCH TRIM INOP. MAINTENANCE CLEANED THE SWITCH.May 5, 2006 · N844MJ · Emb EMB145LR · Stabilizer Control SystemSDR MASA200601266Pcu · inoperativeRUDDER SYSTEM 1 INOPERATIVE. MX REPLACED THE PCU.May 5, 2006 · N857MJ · Emb EMB145LR · Rudder Control SystemSDR F06082Light · inoperativeTHE CREW REPORTED 3 STRIPS OF THE FLOOR EMERGENCY LIGHTING ARE INOPERATIVE. MAINTENANCE RESEATED THE CONNECTORS AND OPS CHECKED.May 5, 2006 · N829MJ · Emb EMB145LR · Emergency LightingSDR C2XA06BT020Flashlight · odorCREW REPORTED, ALL CREW MEMBERS NOTICED AN INSULATION WIRE BURNING SMELL BEHIND CAPTAINS SEAT AND BEHIND THE FLIGHT ATTENDANTS SEAT. GATE RETURNED AIRCRAFT, DURING TAXI. MAINTENANCE INSPECTED NR 1 AND NR 2 RELAY COMPARTMENTS AND RIGHTHAND AND LEFTHAND POWER May 5, 2006 · N29917 · Emb EMB145LR · Emergency EquipmentSDR RAIA00605010Connector · unsecureMX - SEVERAL FWD EMERGENCY LIGHTS INOP. RE-SECURED CONNECTOR TO EMR BATTERY POWER SUPPLY.May 5, 2006 · N819HK · Emb EMB145LR · Light System WiringSDR RAIA00605011Wire · brokenFLT 8071 - MCI - ENGINE 1 FIRE INDICATION. BOTTLE A&B EXTINGUISHERS DISCHARGED. MAINTENANCE REPAIRED BROKEN WIRE ON NR 1 ENGINE PYLON FIRE WIRE CONNECTOR, AND REPLACED BOTH FIRE BOTTLES.May 4, 2006 · N829HK · Emb EMB145LR · Fire Protection System WiringSDR RAIA00605009Warning Message · illuminatedFLT - 8039 - ORD - BAGGAGE DOOR OPEN INDICATION DURING T/O RUN. MAINTENANCE DEFERRED BAGGAGE DOOR WARNING SYSTEM PER MEL.May 4, 2006 · N833HK · Emb EMB145LR · Door Warning SystemSDR RAIA00605007Wire · unsecureMX - SAT EMERGENCY LIGHT STRIP AFT, INOP. RE-SECURED LIGHTING STRIP WIRING.May 3, 2006 · N810HK · Emb EMB145LR · Light System Wiring
Back to Embraer EMB-145LR