Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA05IA048Handle · inoperativeZIH - FLIGHT 2870, THE CREW REPORTED THAT THE LANDING GEAR WOULD NOT EXTEND WITH THE GEAR HANDLE, AND NO WARNING WAS PRESENTED WITH THE FAILURE. THE AIRCRAFT LANDED IN ZIH WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT AND FERRIED IT TO IAH WHERE IAH MSDR MASA200500239Bulb · burned outON RON AND SCHEDULED FOR A 2 DAY ENROUTE INSPECTION DURING THE WALK AROUND IT WAS DISCOVERED THE ROW 14 CEILING EMERGENCY LIGHT NOT ILLUMINATING. REPLACED THE LIGHT BULB, OPS CHECKED GOOD.SDR C2XA05SH018Floor Support · corrodedSHV-DURING C-CHECK, THE CENTER OMEGA BEAM AT FRAME 20 CORRODED. MAINTENANCE REMOVED THE DAMAGED AREA AND PERFORMED REPAIR IAW EMB-145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA05SH019Floor Support · corrodedSHV - DURING C-CHECK THE LEFT HAND OMEGA BEAM AT FRAME 20 IS CORRODED. MAINTENANCE REMOVED THE DAMAGED AREA AND PERFORMED REPAIR IAW EMB-145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA200508704Floor Support · corrodedABI - THE CENTER OMEGA BEAM AT FRAME 24 WAS FOUND TO BE CORRODED. PERFORMED A CUT OUT OF THE CENTER OMEGA BEAM TO REMOVE CORROSION. FABRICATED FILLER, TWO SHIMS AND DOUBLER. REPAIR DONE IAW EMB REPAIR STATEMENT IC2005-145/1180 PARA 2 DATED MARCH 15, 2005. SDR MASA200500234Apu · failedSMOKE IN THE CABIN PRIOR TO THE FIRST FLIGHT OF THE DAY. MX TROUBLESHOT FAULT AND OPERATED ENG NR 2 WITH BOTH PACKS AND FOUND THAT THE SMOKE WAS CAUSED BY THE APU. MX RE-OPENED THE MEL FOR THE APU 3/23/05. MAINTENANCE REPLACED THE APU.SDR MASA200500237Battery Pack · inoperativeASH 2987 BHM HAD THE AFT HALF OF THE EMERGENCY EXIT FLOOR PATH LIGHTING INOP. THE A/C WAS FERRIED TO CLT WHERE THE NR 3 AND NR 4 POWER SUPPLIES WERE REPLACED.SDR SIMA200508702Floor Support · corrodedTHE LEFT OMEGA BEAM AFT OF FRAME 24 WAS FOUND CORRODED. PERFORMED A NINE INCH CUT OUT OF THE OMEGA BEAM TO REMOVE THE CORROSION. FABRICATED A FILLER, EXTERNAL ANGLE AND TWO SHIMS. REPAIR DONE IAW EMB REPAIR STATEMENT IC2005-145/1180 PARA 1 DATED MARCH 15, 2SDR SIMA200507901A/C Pack · malfunctionedLBB - FLT 3390 - CREW REPORTED THE NR 2 PACK FAILED, WITH SMOKE PRESENT IN THE CABIN. THE LAVATORY SMOKE DETECTOR ACTIVATED, THE NR 2 PACK WAS DESELECTED AND THE CABIN SMOKE WENT AWAY WITH ONLY NR 1 RUNNING. PERFORMED OPERATIONAL CHECK OF NR 2 PACK WITH NO DSDR RAIA00503010Controller · malfunctionedSTL - AUTO PRESSURIZATION FAULT INDICATION. MAINTENANCE REMOVED AND REPLACED AUTO PRESSURE CONTROLLER.SDR MASA200500229Bulb · burned outON RON AND SCHEDULED FOR A ROUTINE CHECK INSPECTION, DURING THE WALKAROUND IT WAS DISCOVERED THAT THE RT EXTERNAL OVERWING EMERGENCY LIGHT NOT ILLUMINATING. REPLACED THE LIGHT BULB AND OPS CHECKED GOOD.SDR SIMA200509109Seat Track · corrodedDURING MBV INSPECTION FOUND FORWARD CABIN LT FWD IB SEAT TRACK CORRODED AROUND FASTENERS. REMOVED AND REPLACED LT FWD IB SEAT TRACK IAW MM. AC RETURNED TO SERVICE. (K)SDR SIMA200509108Doubler · corrodedDURING MBV INSPECTION FOUND FORWARD CABIN FLOOR DOUBLER AT FRAME 22 CORRODED AROUND NUTPLATE. INSTALLED NEW DOUBLER AT FRAME 22 IAW SRM. AC RETURNED TO SERVICE. (SW21200504818) (K)SDR SIMA200509107Doubler · corrodedDURING MBV INSPECTION, FOUND FWD CABIN FLOOR DOUBLER AT FRAME 20 CORRODED AROUND AFT NUTPLATE. INSTALLED NEW DOUBLER AT FRAME 20 IAW SRM 51-40-02. AC RETURNED TO SERVICE. (SW21200504818) (K)SDR SIMA200509106Sill · corrodedDURING MBV INSPECTION FOUND FORWARD CABIN FLOOR SILL RT CORRODED AROUND UPPER AFT NUTPLATE BETWEEN FRAMES 19 AND 20. REPAIRED RT FLOOR SILL IAW SRM. AC RETURNED TO SERVICE. (SW21200504818) (K)SDR SIMA200509105Ramp · corrodedDURING MBV INSPECTION FOUND FORWARD CABIN FLOOR SUPPORT RAMP AT FRAME 19 AND 20 CORRODED ON UPPER AND AFT EDGE. REMOVED AND INSTALLED RAMP IAW SRM. AC RETURNED TO SERVICE. (SW21200504818) (K)SDR SIMA200509104Gusset · corrodedDURING MBV INSPECTION, FOUND FORWARD CABIN GUSSET BETWEEN FRAMES 20 AND 23 CORRODED ON UPPER SURFACE. REMOVED AND INSTALLED CABIN GUSSET IAW SRM. AC RETURNED TO SERVICE. (SW21200504818) (K)SDR MASA200500227Connector · unsecureASH 2849 FROM CLT TO GSO, HAD THE RT OVERWING EXIT EMERGENCY EXIT LIGHT INOP. MAINTENANCE SECURED THE LIGHT CONNECTOR AND IT OPERATED NORMALLY. A/C DEPARTED WITHOUT FURTHER INCIDENT.SDR C2XA05BT015Charger · faultyDURING RON MAINTENANCE FOUND EMERGENCY LIGHTS OUT AFT OF EMERGENCY EXIT ROW OF SEATS. MAINTENANCE REMOVED AND REPLACED NR 4 BATTERY CHARGER ASSEMBLY IAW EMB145 AMM 33-50-04. OPS CHECKED GOOD.SDR SIMA200508703Sill · corrodedTHE SERVICE DOOR CENTER SILL WAS FOUND TO BE CORRODED. REMOVED THE CORRODED CENTER SILL AND INSTALLED NEW SERVICEABLE SILL IAW EMB SRM, SRM 145/1142 REV 28, CHAPTER 51-40-02, IC2003-145/0818 DATED MARCH 6, 2003 AND AEA ETN EM-53-013 DATED AUGUST 28, 2001. (MSDR MASA200500223Battery Pack · inoperativeTHE LT OVERWING EXTERIOR EMERGENCY EXIT LIGHT INOP. THE LIGHT WAS PLACED ON MEL AND THE A/C DEPARTED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED POWER SUPPLY.SDR MASA200500218Sign · inoperativeASH 2673 FROM CLT TO CAK HAD THE RT OVERWING EMERGENCY EXIT SIGN INOP. MAINTENANCE RESECURED THE SIGN ASSY AND IT OPERATED NORMALLY. A/C DEPARTED WITHOUT FURTHER INCIDENT.SDR MASA200500217Odor · detectedRETURNED TO THE GATE DUE TO HOT OIL SMOKE SMELL AND VISIBLE SMOKE REPORTED IN CABIN BY F/A. MAINTENANCE RAN BOTH ENGINES AND BOTH PACKS AND WERE UNABLE TO DUPLICATE DISCREPANCY. A/C DEPARTED WITHOUT FURTHER INCIDENT.SDR C2XA05CL016Engine · smokeCLE - FLIGHT 2115 THE CREW REPORTED SMOKE IN CABIN AND FLIGHT DECK FROM PACKS. THE AIRCRAFT RETURNED TO LGA AND MAINTENANCE PLACED PACK NR 1 ON MEL. THE AIRCRAFT HEATING AND AIR CONDITIONING SYSTEM WAS TESTED THE NEXT DAY AND FOUND TO BE OPERATING CORRECTLY,SDR CHQA200500056Odor · detectedLAV SMOKE INDICATION APPEARED ON EICAS DURING CLIMBOUT. A FAINT ELECTRICAL BURNING ODOR WAS NOTED IN THE COCKPIT. RETURNED TO FIELD AND LANDED UNEVENTFULLY. THE LAV SMOKE INDICATION WENT OUT ON SHORT FINAL. THE AIRCRAFT WAS FERRIED TO CMH FOR MAINTENANCE. SDR MASA200500222Skin · dentedIN C-CHECK, PERFORM PERMANENT REPAIR ON SKIN FORWARD OF APU DOOR DUE 1034 FC SHARP DENT REPAIRED, EXTERNAL REPAIR DOUBLER REF SRM 53-32-01.SDR MASA200500221Buttstrap · corrodedIN C-CHECK, BUTT STRAP CORRODED AT LT Y4790 FROM FR 18 TO FR 24 OUT OF LIMITS REF SRM 53-21-10. REPLACED BUTT STRAP.SDR MASA200500220Seat Track · corrodedIN C-CHECK, SEAT TRACK AT LT Y479 CORRODED FROM FR 18 TO FR 24, OUT OF LIMITS REF SRM 53-00-11. REPLACED TRACK.SDR MASA200500219Angle · corrodedIN CHECK, FLOOR RISER AT RT CORRODED FR 23. REMOVED RT OUTBOARD CLIP ON RISER OUT OF LIMIT. FAB NEW PER SAMPLE AND INSTALLED.SDR SIMA200507506Stringer · chafedABI - DURING INSPECTION, FOUND STRINGER 19L WAS FOUND TO BE CHAFED AT AFT FAIRING CUT OUT. BLENDED THE CHAFE AND PERFORMED EDDY CURRENT INSPECTION WITH NO CRACKS NOTED. FABRICATED A DOUBLER, TWO SHIMS. REPAIR DONE IAW EMB SRM, SRM 145/1142 REV 28, CHAPTER 5SDR SIMA200507504Floor Support · corrodedABI - DURING INSPECTION OF AIRCRAFT, A PREVIOUS REPAIR ON THE LEFT OMEGA BEAM AT FRAME 20 WAS FOUND TO BE CORRODED. REMOVED THE CORRODED REPAIR. FABRICATED AN EXTERNAL ANGLE, FABRICATED A FILLER AND THREE SHIMS. REPAIR DONE IAW EMB SRM, SRM 145/1142 REV 28,SDR SIMA200507505Stringer · chafedABI - DURING INSPECTION STRINGER 19L WAS FOUND TO BE CHAFED AT AFT FAIRING CUTOUT. BLENDED THE CHAFE AND PERFORMED EDDY CURRENT INSPECTION WITH NO CRACKS NOTED. FABRICATED A DOUBLER, TWO SHIMS. REPAIR DONE IAW EMB SRM, SRM 145/1142 REV 28, CHAPTER 53-24-02.SDR SIMA200507507Stringer · chafedDURING INSPECTION, 652 STRINGER 19R WAS FOUND TO BE CHAFED AT AFT FAIRING CUTOUT. BLENDED THE CHAFE AND PERFORMED EDDY CURRENT INSPECTION WITH NO CRACKS NOTED. FABRICATED A DOUBLER AND TWO SHIMS. REPAIR DONE IAW EMB SRM, SRM 145/1142 REV 28, CHAPTER 53-24-0SDR MASA200500212A/C Pack · smokeIND HAD PACK 2 GENERATING SMOKE. THE PACK WAS PLACED ON MEL. MAINTENANCE PERFORMED OPERATIONAL CHECK AND THE SYSTEM OPS CHECKED GOOD.SDR MASA200500211Seal · leakingA LOUD PRESSURIZATION SQUEAL COMING FROM THE MAIN PAX DOOR. MAINTENANCE RE-INSTALLED THE FLAPPER SEAL ON THE TOP OF THE DOOR. MAINTENANCE COULD NOT DUPLICATE ANY FURTHER FAULTS WITH PAX DOOR ON THE GROUND.SDR CHQA200500054Smoke · detectedFLIGHT 3039 BOS-MYR - DURING INTIAL CLIMB A LAV SMOKE INDICATION APPEARED ON EICAS. THE FLIGHT ATTENDANT REPORTED THERE WAS NO EVIDENCE OF ODOR, SMOKE, OR FIRE IN THE CABIN. ALL OTHER INDICATIONS IN THE COCKPIT WERE NORMAL. THE AIRCRAFT WAS HEAVILY DE-ICED SDR MASA200500207Bulb · burned outASH 2647 CLT. CREW REPORTED THE CEILING EMERGENCY EXIT SIGN FRONT HALF LIGHTS WERE INOP. MAINTENANCE REPLACED THE LAMPS AND IT OPS CHECKED GOOD.SDR SIMA200507515Sill · corrodedABI - DURING INSPECTION OF AIRCRAFT, THE SERVICE DOOR CENTER SILL WAS FOUND TO BE CORRODED. REMOVED THE CORRODED CENTER SILL. INSTALLED SERVICEABLE SILL IAW EMB SRM, SRM EMB 145/1142 REV 28 CHAPTERS 51-20-01, 51-20-03, 51-40-02, 51-40-04 AND 51-40-06. (M)SDR MASA200500202Apu · failedAN APU FAIL AND GENERATE A SMELL IN THE CABIN. MX FOUND THAT THE APU HAD SIEZED AND PLACED IT ON MEL. MAINTENANCE REPLACED THE APU.SDR CHQA200500053Engine · unserviceableFLIGHT 6236 GSO-MCO - ON INITIAL CLIMB AT APPROXIMATELY 800 FEET, A LAV SMOKE WARNING APPEARED ON EICAS. THE TOWER WAS NOTIFIED AND THE FLIGHT ATTENDANT CHECKED THE CABIN FOR SIGNS OF FIRE OR SMOKE. NO EVIDENCE WAS FOUND. ON SHORT FINAL AN E1 LOW OIL PRESS SDR CHQA200500052Light · inoperativeRIGHT HAND EMERGENCY EXIT LIGHT IS INOP. REMOVED AND REPLACED EXIT MARKER IAW EMB 145 AMM 33-50-14. OPS CHECK GOOD.SDR C2XA05SH17Floor Support · corrodedSHV - DURING C-CHECK CORROSION ON LT OMEGA BEAM I/B SIDE FWD OF FRM 44. MAINTENANCE REMOVED THE DAMAGE AREA AND PERFORMED REPAIR IAW EMB 145 SRM 53-23-10. NO FURTHER ACTION REQUIRED PER EC 5320-01219. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR MASA200500200Ahrs · failedASH 2796 CLT - HAD AN AUTO PILOT DISENGAGE DUE TO AN AHRS INOP. MAINTENANCE REPLACED THE AHRS COMPUTER.SDR SIMA200507002Power Supply · dischargedAFT TWO EMERGENCY LIGHTING STRIPS WILL NOT ILLUMINATE DURING TEST. REPLACED THE NR 4 EMERGENCY LIGHT POWER SUPPLY. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR MASA200500199A/C Pack · smokeSMOKE IN THE CABIN ON THE GROUND COMING FROM PACK 2. PACK 2 WAS PLACED ON MEL. MAINTENANCE COULD NOT DUPLICATE, OPS CHECKED NORMAL.SDR CHQA200500050Light · inoperativeEMERGENCY FLOOR PROXIMITY LIGHTING IS INOP AT SEATS 8 AND 9. REMOVED AND REPLACED FLOOR LIGHT STRIP IAW EMB 145 AMM 33-50-12. OPS CHECK GOOD.SDR CHQA200500051Engine · unserviceableFLIGHT 6236 MCO-GSO - AT APPROXIMATELY 400 FEET A LAV SMOKE MESSAGE APPEARED ON EICAS. THE TOWER WAS ALERTED AND AFTER TWO MINUTES THE MESSAGE DISAPPEARED. THE FLIGHT ATTENDANT FOUND NO EVIDENCE OF SMOKE OR FIRE ANYWHERE IN THE CABIN. THE AIRCRAFT RETURNED SDR MASA200500198Control System · malfunctionedA FLAP FAIL ON APPROACH. CONTRACT MAINTENANCE WAS ABLE TO REST AND PERFORM OPERATIONAL TEST OF FLAP SYSTEM WITH NO DEFECTS NOTED.SDR C2XA05BT016Sign · faultyDURING 4A INSPECTION IN BTV, MAINTENANCE FOUND THE EMERGENCY EXIT LIGHT SIGN AT SEAT 12A AREA TO BE NOT OPERATING. REMOVED AND REPLACED EMERGENCY EXIT SIGN AT 12A AREA IAW EMB145 MM 33-50-14. OPS CHECKED GOOD.SDR MASA200500201Light · malfunctionedAFTER SHUTTING DOWN ACFT IN YYZ, FLIGHT CREW REPORTED THAT EMERGENCY LIGHTS WOULD NOT EXTINGUISH UNTIL CREW CYCLED THE BATTERY AND EMERGENCY LIGHT SWITCHES. CONTRACT MAINTENANCE PERFORMED OPERATIONAL CHECK OF EMERGENCY LIGHTING SYSTEM. NO DEFECTS WERE NOTED.
Back to Embraer EMB-145LR