Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA200405502Connector · disconnectedEMERGENCY EXIT SIGN ABOVE GALLEY SERVICE DOOR INOPERATIVE AND EMERGENCY EXIT SIGN ON RT FW BULKHEAD IN FRONT OF SEATS 2 B,C INOPERATIVE. FOUND CONNECTOR P8530 OFF, RECONNECTED P8530. AC GOOD IAW MFG AMM. (SW21200406975)SDR RAIA00402025Proximity Switch · malfunctionedSTL - SPOILER AND AIR/GRN FAIL MESSAGE. MAINTENANCE REMOVED AND REPLACED AIR/GRN PROX SWITCH.SDR RAIA00402023Proximity Switch · faultySTL - SPOILER FAIL MESSAGE. MAINTENANCE REMOVED AND REPLACED AIR/GRN PROX SWITCH.SDR C2XA04IA017Tube · leakingON APPROACH INTO CUU THE NR 1 ENGINE LOW OIL PRESSURE WARNING ILLUMINATED. THE AIRCRAFT LANDED AT CUU WITHOUT INCIDENT WHERE THE AIRCRAFT WAS INSPECTED. THE OIL PRESSURE TUBE ASSEMBLY/REGULATING TEE, WAS FOUND TO BE LEAKING AND WAS REPLACED. THE NR 1 ENGINESDR CHQA0000436Unknown · odorBURNING RUBBER OR PLASTIC ODOR INFLIGHT FOR ABOUT 2 MINUTES. SMELLED IT IN COCKPIT FIRST AND FLIGHT ATTENDANT AND PASSENGERS SMELLED IT AS WELL. ONLY LASTED 2 MINUTES. WE WERE IN CLOUDS WITH LIGHTENING IN THE AREA. MCO MAINTENANCE THOROUGHLY CHECKED THE AISDR MASA200400099Sign · inoperativeEMERGENCY EXIT SIGN INOP ROW 12. MX SECURED CONNECTION AT LIGHT, OPS CHECKED GOOD. NO PARTS USED.SDR MASA200400097Sign · inoperativeEMERGENCY EXIT SIGN ROW 12 RIGHT SIDE INOP. MX REPLACED SIGN ASSY, OPS CHECKED GOOD.SDR C2XA04IA021Light · inoperativeDURING SCHEDULED MAINTENANCE THE LEFT OVERWING EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED LAMP, OPERATIONALLY TESTED THE LIGHT AND CLEARED THE DISCREPANCY.SDR C2XA04TY039Connector · loosePILOT REPORT, PORT EMERGENCY EXIT LIGHT INOP. MAINTENANCE SECURED THE PORT EMERGENCY EXIT LIGHT CONNECTOR. AIRCRAFT WAS RELEASED.SDR RAIA00402022Control Unit · malfunctionedSTL - MAIN PITCH TRIM INOP. MAINTENANCE RE-RACKED HORIZONTAL STAB CONTROL UNIT AND CHECKED OK.SDR C2XA04CL013Inverter · inoperativeIAH FLIGHT 2611 THE CREW REPORTED THE RIGHT OVERWING UPPER EMERGENCY EXIT SIGN WAS INOPERATIVE. MAINTENANCE REPLACED THE EMERGENCY EXIT LIGHT INVERTER. OPERATIONAL CHECKS WERE GOOD.SDR CHQA0000435Odor · detectedDURING TAKEOFF OUT OF MCO ON FLIGHT 6451, NOTICED A BURNING ODOR FAINTLY COMING THROUGH THE COCKPIT. F/O AND FLIGHT ATTENDANT CONCURRED. F/A REPORTED A STRONG BURNING ODOR COMING FROM THE GALLEY, NO VISIBLE SMOKE OR FIRE. AIR TURNBACK INTO MCO AND LANDED WISDR MASA200400096Socket · burnedAIRCRAFT DIVERTED TO CLT ORIGINALLY EN ROUTE TO DHM. THE CREW REPORTED A NR 3 PITOT HEAT MESSAGE AND AN ELECTRICAL ODOR IN THE COCKPIT. MX ISOLATED THE PROBLEM TO THE CURRENT SENSOR AND SOCKET BEING BURNED. MX REPLACED THE SENSOR, SOCKET AND REPAIRED ANY DASDR SIMA200406401Battery · failedSUBMITTED OPEN AWAITING DISCREPANCY AND TIMES AND CYCLES AND SERIAL NUMBER. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY BATTERY IAW MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.SDR C2XA04BT023Light · inoperativeDURING SERVICE AND ROUTINE INSPECTION MAINTENANCE FOUND OVERHEAD EMERGENCY LIGHT AFT OF EMERGENCY EXIT AISLE TO BE INOPERATIVE. REMOVED AND REPLACED EMERGENCY AISLE LIGHT IAW EMB145 MM 33-50-08. OPS CHECKED GOOD.SDR MASA200400093Bulb · inoperativeLEFT FWD EXTERIOR EGRESS LIGHT INOP. MX RELAMPED. OP CHECKS GOOD.SDR C2XA04IA016Mechanism · lack of lubeDURING POSTFLIGHT INSPECTION THE MAIN PASSENGER DOOR WAS FOUND DIFFICULT TO OPERATE. MAINTENANCE LUBRICATED THE PASSENGER DOOR LOCKING MECHANISM AND OPERATIONALLY TESTED THE DOOR.SDR C2XA04TY038Floorbeam · corrodedTYS DURING A SCHEDULED INSPECTION CORROSION WAS FOUND ON THE CENTER FLOORBEAM AT FRAME 20. MAINTENANCE REMOVED AND REPLACED THE CENTER OMEGA BEAM IAW EMB145 SRM 51-40-02, THE REPAIR WAS SATISFACTORY. THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTISDR C2XA04TY037Floorbeam · corrodedDURING A SCHEDULED INSPECTION CORROSION WAS FOUND ON THE GALLEY FLOORBEAM RAMP ANGLE. MAINTENANCE REMOVED AND REPLACED THE RAMP ANGLE IAW EMB145 SRM 51-40-02, THE REPAIR WAS SATISFACTORY. THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTION.SDR C2XA04SH071Light · inoperativeSHV- DURING A ROUTINE CHECK THE COCKPIT CEILING EMERGENCY LIGHT WAS FOUND TO BE INOPERATIVE DURING THE EMERGENCY LIGHT FUNCTIONAL TEST. MAINTENANCE REMOVED AND REPLACED THE INOPERATIVE BULB IAW EMB 145 AMM 33-50-05. THE AIRCRAFT WAS APPROVED FOR RETURN TO SESDR CHQA000441Battery · dischargedRIGHT WING EMERGENCY LIGHT DOESN'T WORK. FOUND EMERGENCY BATTERY INOP. REMOVED AND REPLACED BATTERY POWER UNIT IAW EMB 145 AMM CH 33-50-04.SDR RAIA00402019Valve · leakingIAD - FUEL LEAKING FROM RIGHT WING VENT DURING CLIMB. MAINTENANCE VERIFIED RIGHT WING VENT VALVE CLOSED.SDR CHQA000442Bulb · inoperativeLEFT WING EMERGENCY LIGHT INOP. REMOVED AND REPLACED LEFT WING EMERGENCY LIGHT BULB IAW EMB 145 MM 33-50-10. OPS CHECK GOOD. BULB P/N 1317.SDR MASA200400088Bulb · inoperativeDURING OVERNIGHT MX IT WAS DISCOVERED THAT THE RT FWD EXTERNAL EMERGENCY LIGHT WAS INOP. MX REPLACED THE BULB BUT THAT DID NOT FIX IT. MX PLACED ON MEL.SDR CHQA000443Light · malfunctionedNO POWER LEFT TO EMERGENCY LIGHTS. MECHANIC TESTED LIGHTS IAW EMB-145 MM 33-50-00. FOUND TO BE WORKING OK.SDR RAIA00402018Proximity Switch · malfunctionedRIC - NLG WILL NOT RETRACT. MAINTENANCE REMOVED AND REPLACED WOW PROX SWITCH.SDR SIMA200404603Battery · inoperativeCMH - FLT 4401 - CRWE REPORTED THE EMERGENCY CABIN LIGHTS IN THE LAST THREE ROWS TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY LIGHT BATTERY PACK. OPS CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR MASA200400083Bulb · inoperativeFWD FLOOR PROX LIGHTING STRIP INOP. MX REPLACED THE BULB, OP CHECKS GOOD.SDR MASA200400082Bulb · burned outDURING A RON, DISCOVERED THE LEFT OVERWING EMERGENCY LIGHT WAS INOP. MX REPLACED THE LAMP. OP CHECKS GOOD.SDR MASA200400081Bulb · burned outEMERGENCY EXIT FLOOD LIGHT INOP. MX RESET LIGHTING SYSTEM. OP CHECKS GOOD.SDR RAIA00402017Seal Ring · leakingSTL - RIGHT ENGINE BLEED LEAK. MAINTENANCE REMOVED AND REPLACED BLEED LINE SEAL UNDER CARGO BAY FLOOR.SDR CHQA000463Light · inoperativeRIGHT AFT EXTERIOR EMERGENCY LIGHT INOP. REMOVED AND REPLACED BULB, OPS CHECK GOOD.SDR CHQA000445Light · inoperativeEMERGENCY CEILING LIGHT INOPERATIVE. REMOVED AND REPLACED BULB, OPS CHECK GOOD IAW EMB 145 AMM 33-25-01.SDR C2XA04BT020Wire · brokenCREW REPORTED, AISLE PATH EMERGENCY EXIT LOCATOR STRIP LIGHT INOPERATIVE. MAINTENANCE FOUND BROKEN WIRE TO FORWARD AISLE PATH EMERGENCY LIGHT STRIP. REPAIRED BROKEN WIRE AS REQUIRED IAW EMB145 MM 70-60-00. OPS CHECKED EMERGENCY LIGHTS GOOD.SDR C2XA04SH059Skin · dentedSHV - DURING C-CHECK THE FUSELAGE SKIN WAS FOUND TO BE DENTED BETWEEN FRAMES 19 AND 20 AT STRINGER 7L, JUST AFT OF THE MAIN DOOR. MAINTENANCE REMOVED THE AFFECTED SECTION OF STRINGER 7L, RE-CONTOURED THE DENTED AREA OF SKIN, AND INSTALLED A NEW 7L STRINGER SESDR C2XA04SH058Firewall · crackedDURING C-CHECK THE APU FIREWALL WAS FOUND TO BE CRACKED AT THE UPPER RT APU MOUNT. MAINTENANCE PERFORMED A DOUBLER REPAIR TO THE AFFECTED AREA IAW CONTINENTAL EXPRESS EC 5330-01267. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR MASA200400079Bulb · burned outCEILING EMERGENCY EXIT LIGHT INOPERATIVE AT EXIT ROW. MECHANIC REPLACED BULB. OP CHECKS GOOD.SDR MASA200400078Battery · dischargedCREW WROTE-UP THE EMERGENCY EXIT LIGHT BATTERIES HAD LOW VOLTAGE. MECHANIC PERFORMED AN OP CHECK OF THE SYSTEM. MECHANIC COULD NOT DUPLICATE. NO PARTS USED.SDR CHQA000457Wire · exposedPROXIMITY STRIP HAS EXPOSED WIRES ON CONNECTOR AT261BF. REMOVED AND REPLACED PROXIMITY STRIP LIGHT IAW EMB 145 AMM 33-50-08-4.SDR CHQA000460Wire · exposedPROXIMITY STRIP HAS EXPOSED WIRES ON CONNECTOR AT261BF. REMOVED AND REPLACED PROXIMITY STRIP LIGHT IAW EMB 145 AMM 33-50-08-4.SDR MASA200400077Connector · unsecureEMERGENCY EXIT PATH LIGHTING INOPERATIVE. MECHANIC SECURED CONNECTION AT LIGHTING STRIP. OPS CHECKS GOOD. NO PARTS USED.SDR RAIA00402011Spring · out of adjustSTL - F/O'S WINDSHIELD WIPER MOVING WHEN IN PARK. MAINTENANCE ADJUSTED SPRING TENSION ON F/O'S WIPER MECHANISM.SDR C2XA04TY035Floorbeam · corrodedTYS - DURING A SCHEDULED INSPECTION CORROSION WAS FOUND ON THE CENTER OMEGA BEAM TOP CAP AT FRAME 15. MAINTENANCE REMOVED AND REPLACED THE TOP CAP IAW EMB SRM 51-40-02, THE REPAIR WAS SATISFACTORY. THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTION.SDR C2XA04TY034Floorbeam · corrodedTYS - DURING A SCHEDULED INSPECTION CORROSION WAS FOUND ON THE CENTER FLOORBEAM AT FRAME 20. MAINTENANCE ACCOMPLISHED A DOUBLER REPAIR IAW EMB SRM 53-21-10, THE REPAIR WAS SATISFACTORY. THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTION.SDR C2XA04BT019Filter · faultyCREW REPORTED, MELTING PLASTIC ODOR FOLLOWED BY BLEED NR 2 OVERHEAT WHILE IN ICING CONDITIONS. MAINTENANCE PERFORMED FIM TASK 36-11-00-810-803A, REMOVED AND REPLACED FAN AIR VALVE FILTER IAW EMB145 MM 36-11-03. PERFORMED OPS CHECK IAW EC3610-01062 STEPS 2.4 SDR C2XA04BT017Landing Gear · malfunctionedCREW REPORTED, AIR RETURNED, GEAR WOULD NOT RETRACT. MAINTENANCE OPERATIONALLY CHECKED LANDING GEAR EXTENSION AND RETRACTION, FOUND NORMAL OPERATION IAW EMB145 AMM 32-30-00. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR C2XA04TY033Angle · corrodedTYS - DURING A SCHEDULED INSPECTION CORROSION WAS FOUND ON THE CENTER RAMP ANGLE AT FRAME 20. MAINTENANCE REMOVED AND REPLACED THE RAMP ANGLE IAW EMB SRM 51-40-02, THE REPAIR WAS SATISFACTORY. THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTION.SDR C2XA04TY032Bracket · corrodedTYS - DURING A SCHEDULED INSPECTION CORROSION WAS FOUND ON THE PASSENGER DOOR SILL PLATE ATTACH BRACKET. MAINTENANCE REMOVED AND REPLACED THE ATTACH BRACKET IAW EMB SRM 51-40-02 AND CPM 51-21-05,06. THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTIONSDR CHQA000461Light · inoperativeRT WING OVERWING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED RT WING OVERWING EMERGENCY LIGHT. OPS CHECK GOOD IAW EMB 145 AMM 33-50-10.SDR CHQA000458Light · inoperativeRIGHT WING OVERWING EMERGENCY LIGHT INOP. REMOVED AND REPLACED RIGHT WING OVERWING EMERGENCY LIGHT. OPS CHECK GOOD IAW EMB 145 AMM 33-50-10.
Back to Embraer EMB-145LR