Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA01CL164Apu · failedBNA FLT 4046, THE CREW REPORTED APU AUTOSHUT DOWN CAUSING SMOKE IN AIRCRAFT. MAINTENANCE REPLACED APU. OPERATIONAL CHECKS WERE GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.SDR CHQ00003Filter · cloggedNR 1 BLEED OVER TEMP LIGHT ILLUMINATED ON CLIMBOUT. CREW RETURNED TO FIELD. MAINTENANCE UNPLUGGED CLOGGED FILTER ON SENSING LINE.SDR SIMA200119301Light · inoperativeMSN - FLT 4044 - DURING PRE-FLIGHT INSPECTION, CREW REPORTED THE AFT FLOOR PROXIMITY EMERGENCY LIGHTS DID NOT ILLUMINATE. MAINTENANCE REPLACED THE AFT LIGHT STRIP IAW EMB MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR C2XA01IA293Odor · detectedIAH - FLIGHT 3925, THE CREW REPORTED AN ELECTRICAL BURNING SMELL IN THE AFT CABIN DURING CRUISE, AND AN OCCASIONAL SMELL IN THE COCKPIT AS WELL. THE CREW DEACTIVATED THE NUMBER TWO BLEED AS A PRECAUTION WITH NO CHANGE IN ODOR. THE AIRCRAFT LANDED AT IAH WITHSDR C2XA01CL163Loop · faultyCLE FLT.#3743 THE CREW REPORTED RIGHT ENGINE FIRE DETECTOR FAILED TESTMAINTENANCE REPLACED RIGHT ENGINE FIRE DETECTOR LOOP. OPERATIONAL CHECKS WERE GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.SDR C2XA01IA289Light · inoperativeIAH - DURING PREFLIGHT INSPECTION, THE CREW REPORTED THAT A SECTION OF THE AISLE PATH EMERGENCY EXIT LIGHTS WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE AFFECTED SECTION OF AISLE PATH LIGHTING, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA01IA291Connector · dirtyMEM- DURING TAKEOFF THE AIR TRAFFIC CONTROL AT MEM REPORTED TO THE CREW THAT FLUID WAS COMING OFF BOTH WINGS. THE CREW NOTED THAT THE FUEL QUANTITY DECREASED BY 600 POUNDS, AND THAT FUEL TRANSFERRED TO THE LEFT WING WITH THE CROSSFEED OFF. THE AIRCRAFT RETURSDR RAIA00107001Sensor · failed5273-RIC ON TAXI OUT #1 PITOT HEAT FAILED-MAINTENANCE REMOVED AND REPLACED #1 PITOT TUBE/SENSORSDR C2XA01CL159Engine · flamed outACY-CLE FLIGHT 3489 THE CREW REPORTED THE NR 1 ENGINE FLAMED OUT CLIMBING OUT OF 28,000 FT THE AIRCRAFT DIVERTED INTO BWI AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE NR 1 ENGINE AND OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASED FOSDR SIMA200117902Control Handle · malfunctionedIND- FLT 9760 - DURING CLIMB, CREW REPORTED THE LANDING GEAR HANDLE COULD NOT BE MOVED TO THE UP POSITION. EICAS SHOWED A LANDING GEAR AIR/GROUND FAIL MESSAGE. MAINTENANCE COULD NOT DUPLICATE DISCREPANCY. OPERATIONAL CHECK OF LANDING GEAR RETRACT EXTEND SYSSDR C2XA01IA283Apu · odorLIT - FLIGHT 4047, THE CREW REPORTED A STRONG FUEL ODOR AT FL350 WITH BOTH BLEEDS AND PACKS SELECTED. THE AIRCRAFT LANDED AT LIT WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE AIRCRAFT. PERFORMED OPERATIONAL TESTS WITH BOTH ENGINES RUNNING, AND NO DEFECTS SDR SIMA200117401Light · malfunctionedMSN - FLT 3426 - FOUND FLOOR EMERGENCY PROX LIGHTS FROM ROWS 12 AFT CAME ON THEN EXTINGUISHED. PERFORMED OPS CHECK TO SYSTEM IAW AMM, OPS CHECK GOOD. NO DEFECTS NOTED. (M)SDR C2XA01CL149Apu · failedBTV FLIGHT#4059 THE CREW REPORTED THE APU HAD A AUTO SHUT DOWN ON THE GROUND.MAINTENANCE REPLACED THE APU.OPERATIONAL CHECKS WERE GOOD.THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR C2XA01BT117Apu · failedBTV---CO4069, CREW REPORTED WHILE TAXING OUT THAT THE APU FAILED AND FILLED THE CABIN WITH SMOKE. AIRCRAFT RETURNED TO THE GATE. MAINTENANCE INSPECTED AND FOUND FAULTY APU, PLACED APU ON MEL AND RETURNED AIRCRAFT TO SERVICE.SDR C2XA01IA272Light · inoperativeIAH- DURING 5A INSPECTION MAINTENANCE NOTED THAT THE AFT CEILING EMERGENCY LIGHT FAILED TO ILLUMINATE DURING OPERATIONAL TEST. IAH- MAINTENANCE REMOVED AND REPLACED THE LIGHT BULB, PERFORMED A OPERATIONAL CHECK, NO DEFECTS NOTED AND THE AIRCRAFT WAS APPROVED SDR C2XA01IA290O-Ring · brokenMKE - THE CREW REPORTED A NUMBER ONE ENGINE BLEED LEAK WARNING. THE AIRCRAFT RETURNED TO MKE WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE O-RINGS ON THE NUMBER ONE ENGINE T-TUBE, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR M01053Apu · leakingTHE CREW FOUND SMOKE IN THE CABIN WITH THE PACKS ON. MAINTENANCE WAS CALLED AND FOUND OIL IN THE BLEED LINES FROM THE APU. THE APU WAS DEFERRED AND THE BLEED VALVE CLOSED. ON 07/01/2001 MAINTENANCE REMOVED AND REPLACED THE APU UNIT.SDR SIMA200116902Duct · damagedORD - FLT 4262 - DURING FLIGHT, CREW REPORTED A NR 2 BLEED LEAK. AFTER LANDING CARGO FIRE WARNING LIGHT ILLUMINATED. CREW FIRED BOTTLES. MAINTENANCE FOUND A DAMAGED DUCT BEHIND AN AFT CARGO WALL. DUCT WAS REPLACED, OPS CHECK WAS GOOD. FIRE BOTTLES WERE RESDR SIMA200116501Door · out of adjCID - FLT 3954 - ON TAKEOFF ROLL HAD NR 1 THRUST REVERSER DISAGREE AND THAN NR 2. ABORTED TAKEOFF AND RETURNED TO GATE. ADJUSTED LEFT AND RIGHT THRUST REVERSE ACTUATOR DOORS IAW AMM. OPS CHECK GOOD. (M)SDR C2XA01BT114Receptacle · odorGSP---CO4088, CREW REPORTED LEFT HAND COFFEE RECEPTACLE GIVES OFF BURN SMELL. MAINTENANCE PLACED BOTH COFFEEMAKERS ON MEL AND RETURNED THE AIRCRAFT TO SERVICE.SDR SIMA200116301Light · inoperativeDFW - FOUND ROWS 4 AND 6 EMERGENCY FLOOR LIGHTING INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT STRIP IAW AMM. OPS CHECK GOOD. (M)SDR CHQA279612Flap · malfunctionedUNKNOWN FLAP PROBLEM. PILOT DECLARED EMERGENCY. MAINTENANCE NOTIFIED BY DISPATCH.SDR C2XA01CL137Control Unit · failedBTV DURING OPERATIONAL CHECK OF LANDING GEAR WARNING SYSTEM THE RIGHT DOWN INDICATOR DID NOT SHOW DOWN AND LOCKED. MAINTENANCE REPLACED THE LANDING GEAR ELECTRONIC UNIT. OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR SIMA200115904Controller · malfunctionedDFW - FLT 3350 - UNCOMMANDED PITCH TRIM MOVEMENT FROM 4 DEGREES TO 2 DEGREES DOWN WHILE TAXIING. PERFORMED OPS CHECK OF PITCH TRIM SYSTEM IAW AMM. COULD NOT DUPLICATE, NO DEFECT NOTED. AIRCRAFT RETURNED TO SERVICE. (M)SDR SIMA200115902Skin · corrodedABI - DURING MBV INSPECTION UNDER FLOOR OF AIRCRAFT, THE LEFT OMEGA BEAM WAS FOUND TO BE CORRODED BEYOND SRM LIMITS AT FRAME 20. REMOVED AND REPLACED CORRODED AREA. WORK DONE IAW EMB SRM 145/1142 REV 12 CHAPTER 53-21-10 PATE 201 THROUGH PAGE 204. (M)SDR SIMA200115801EngineON TAKEOFF, E1 ATTS NO MARGIN. ABORTED TAKEOFF. REMOVED AND REPLACED LEFT ENGNIE IAW WC 05-50-00-400-801-A RUN AND OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)SDR SIMA200115706Switch · out of adjBMI - FLT 4427 - CARGO DOOR WARNING LIGHT CAME ON INFLIGHT. DROPPED TO 10,000. RETURNED TO BASE. ADJUSTED FORWARD AND AFT MICROSWITCHES ON CARGO DOOR IAW AMM 52-76-01-820-801-A. OPS CHECK GOOD. (M)SDR SIMA200115701O-Ring · leakingCMH - FLT 4160 - AIRCRAFT RETURNED TO FIELD FOR NR 1 BLEED LEAK. REMOVED AND REPLACED CARGO COMPARTMENT BLEED LINE O-RING IAW AMM 36-11-801-A AND 36-11-00-400-801-A. OPS CHECK GOOD. (M)SDR SIMA200115702Control Valve · faultySHV - FLT 3370 - ABORTED TAKEOFF, NR 2 THRUST REVERSE DISAGREE ICAS MESSAGE. MEL REMOVED AND REPLACED NR 2 ISOLATION CONTROL VALVE UNIT IAW EMB 78-33-01. OPS CHECK GOOD. (M)SDR C2XA01BT113Receptacle · faultyEWR--CO4228, CREW REPORTED BURNING SMELL COMING FROM COFFEE POT.....MAINTENANCE REMOVED AND REPLACED COFFEE POT RECEPTACLE IAW EMB145 MM #25-31-00....OPS. CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR SIMA200115622Warning Light · false indicationCMH - FLT 4093 - NR 2 BLEED LEAK IN FLIGHT. COULD NOT DUPLICATE PROBLEM. PERFORMED CHECKS IAW AMM. AIRCRAFT RETURNED TO SERVICE. (M)SDR C2XA01TY094Bearing · disintegratedEWR FLIGHT 4142 CREW REPORTED THAT ON TOUCHDOWN THE NOSE GEAR IMMEDIATELY BEGAN TO VIBRATE. ON THE POST FLIGHT INSPECTION THE NOSE WHEEL BEARING WAS DISCOVERED TO BE DISINTEGRATED. MAINTENANCE REMOVED AND REPLACED THE NOSE LANDING GEAR STRUT ASSEMBLY IAW ESDR SIMA200115507Switch · out of adjORF - FLT 4366 - ABORTED TAKEOFF, NR 1 ENGINE REVERSE DISAGREE ICAS. PERFORMED STOW SWITCH TEST IAW EMB AMM 78-34-01-700-801A. PERFORMED ADJUSTMENT IAW 78-34-01-820-801A OF AMM. OPS CHECK GOOD. (M)SDR C2XA01IA260Coffeemaker · faultyIAH - FLIGHT 4028, THE CREW REPORTED A SMOKE ODOR COMING FROM THE GALLEY AREA IN FLIGHT. THE POWER FOR THE GALLEY WAS SHUT OFF AND THE CIRCUIT BREAKERS FOR THE GALLEY WERE PULLED, WITH DISSIPATION OF THE ODOR FOLLOWING. THE AIRCRAFT CONTINUED TO IAH WHERE ITSDR C2XA01CL128Control Handle · failedCLE FLIGHT 4059 THE CREW REPORTED THE LANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF FROM CLEVELAND. RECEIVED A LG/LEVER DISAGREE MESSAGE ON THE EICAS. THE AIRCRAFT RETURNED TO CLEVELAND AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE LANDING GESDR C2XA01CL125Control Handle · failedCLE FLT 3985 THE CREW REPORTED THE LANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF. THE AIRCRAFT RETURNED TO CLEVELAND AND LANDED WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED LANDING GEAR SELECTOR LEVER. OPERATIONAL CHECKS WERE GOOD. AIRCRAFT WAS RELESDR C2XA01IA259Control Unit · malfunctionedYUL - FLIGHT 3675, THE CREW REPORTED THAT THE LANDING GEAR WOULD NOT RETRACT. THE CREW CYCLED THE LANDING GEAR IN ACCORDANCE WITH THE QRH, AND THE GEAR RETRACTED SUCCESSFULLY AFTER SIX ATTEMPTS. THE AIRCRAFT CONTINUED TO CLE WHERE IT LANDED WITHOUT INCIDENT.SDR C2XA01IA256Battery · dischargedIAH- DURING 1A INSPECTION IT WAS NOTED THAT THE EMERGENCY FLOOR LIGHTING MIDDLE SECTION DID NOT ILLUMINATE WHEN SELECTED. IAH- MAINTENANCE REMOVED AND REPLACED THE EMERGENCY BATTERY, OPERATIONAL CHECKED. NO DEFECTS NOTED AND THE AIRCRAFT WAS APPROVED FOR RETSDR SIMA200115002Sensor · defectiveORD - FLT 4431 - CREW REPORTED SPS TWO WARNING ON EICAS. AIRCRAFT WAS RETURNED TO ORD. MAINTENANCE REMOVED AND REPLACED THE NR 2 AOA SENSOR. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WS RETURNED TO SERVICE. (M)SDR SIMA200114804Door · openORD - FLT 4215 - CREW REPORTED AN AUDIBLE VIBRATION COMING FROM THE LEFT SIDE OF AIRCRAFT NOSE. MAINTENANCE FOUND THE GPU ACCESS DOOR TO BE OPEN. DOOR WAS DAMAGED AND WAS PUT ON CDL AT THIS TIME. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR SIMA200114807Carbon Seal · leakingORD - FLT 4051 - CREW REPORTED THE LAVATORY SMOKE WARNING MESSAGE ON EICAS AND THEN WENT OUT. TAKEOFF WAS ABORTED AND EMERGENCY WAS DECLARED. ORD FIRE DEPARTMENT FOUND NO EVIDENCE OF ANY SMOKE OR ANYTHING BURNED. MAINTENANCE FOUND THE ZERO CARBON SEAL LEAKISDR SIMA200114809O-Ring · wornORD - FLT 4112 - CREW REPORTED ENGINE TWO BLEED LEAK LIGHT CAME ON AFTER TAKEOFF. CREW RETURNED AIRCRAFT TO ORD. MAINTENANCE REPLACED O-RINGS AT COUPLING UNDER AFT PASSENGER SEAT NEAR THE LAVATORY. OPS CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (SDR CHQA200262528Warning System · malfunctionedAFTER TAKEOFF- THERE WAS EICAS INDICATION THAT ALL PRESSURIZATION WAS LOST. A/C RETURNED TO FIELD. MAINTENANCE PERFORMED OPERATIONAL CHECK OF PRESSURIZATION CONTROL SYSTEM. RAN GROUND AND TEST FLIGHT, OPS CHECK GOOD.SDR CHQA2000004Handle · vibratesAFTER TAKEOFF, CREW EXPERIENCED NOISE AND VIBRATION THROUGH LEFT WINDOW HANDLE.SDR SIMA200114703Control Unit · inoperativeDFW - FLT 3331 - CREW REPORTED THE NR 1 PITCH TRIM INOPERATIVE MESSAGE ON EICAS. MAINTENANCE REMOVED AND REPLACED THE HORIZONTAL STABILIZER CONTROL UNIT IAW EMB MM. OPS CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR SIMA200114501Switch · malfunctionedCVG - FLT 4390 - CAPTAINS AND FIRST OFFICERS PITCH TRIM INOPERATIVE ON THE YOKE. STANDBY TRIM OPERATED NORMAL. EMERGENCY WAS DECLARED AND AIRCRAFT WAS LANDED SAFELY. MAINTENANCE COULD NOT DUPLICATE DISCREPANCY. OPS CHECK OF CAPTAIN AND FIRST OFFICERS YOKE SDR SIMA20011415Probe · inoperativeORD - FLT 4003 - DURING CRUISE FLIGHT, THE RIGHT TAT HEAT FAILED. THE FLT WAS RETURNED TO ORD. MAINTENANCE REMOVED AND REPLACED THE NR 2 TAT PROBE IAW EMB MM. OPS CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR SIMA20011403Skin · corrodedABI - DURING MBV INSPECTION, MAINTENANCE FOUND THE FORWARD DIGITAL CORRODED. CORROSION WAS REMOVED AND A DOUBLER WAS INSTALLED IAW EMB GST-1595/01. (M)SDR SIMA20011371Sensor · inoperativeDFW - FLT 3759 - CREW REPORTED A NR 2 HOT BRAKE INDICATION ON TAKEOFF ROLL. TAKEOFF WAS ABORTED AND AIRCRAFT WAS RETURNED TO THE GATE. MAINTENANCE REMOVED AND REPLACED THE LEFT INBOARD BRAKE TEMP SENSOR IAW EMB MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WASDR SIMA20011402Skin · corrodedABI - MAINTENANCE FOUND CORROSION IN FLOOR CENTER BEAM AT FRAME 20 AND 22. CORROSION WAS REMOVED AND A DOUBLER WAS INSTALLED IAW EMB GST-159/01. AIRCRAFT WAS RETURNED TO SERVICE. (M)
Back to Embraer EMB-145LR