Embraer EMB-145LR

Service difficulty reports · 36,797

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145LR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR V0XD20230406001Gusset · corrodedLAV UNDERFLOOR GUSSET AT FRM 59-61 STGR 17L CORRODED OUT OF LIMITS. REMOVED AND REPLACED GUSSET AT FRM 59-61 STGR 17L IAW EMB 145 SRM 51-40-02. SEE AVMAX WO: 81033 WC: 1093.Feb 21, 2023 · N15986 · Emb EMB145LR · Fuselage Miscellaneous StructureSDR V0XD20230317001Gusset · corrodedCORROSION FOUND ON LAV UNDER FLOOR GUSSETT AT FR 59 - FR 61 STR 17R. CORRECTIVE ACTION IS TO REMOVE AND REPLACE R/H LAV UNDERFLOOR GUSSETT, FR 59 - FR 61 STR 17R IAW EMB145 SRM 51-20-03 AND SRM 51-40-02. AVMAX WO 80133 WC 1094.Feb 21, 2023 · N15986 · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20230221001Strip · inoperativeEMERGENCY FLOOR LIGHT INOP AT ROWS 8 AND 9-C/A-RAR EMERGENCY EXIT LIGHT STRIP INTO MEL AT ROW 8 AND 9.Feb 21, 2023 · N622AE · Emb EMB145LR · Emergency LightingSDR 2023F00060None · noneUNABLE TO PRESSURIZE A/C IN IETHER AUTOMATIC OR MANUAL MODE WITH LIGHT VISIBLE AROUND MAIN PAX DOORFeb 21, 2023 · N685AE · Emb EMB145LR · Cabin Pressure ControllerSDR 4DPA2023022000001Duct Clamp · wornISSUE-CREW REPORTED WHILE ON CLIMB OUT RECEIVED BLD 2 LEAK AT APPPROX 15,000 FEET. RAN QRH AND RETURNED TO DAL. CORR ACTION- MX TROUBLESHOT SYSTEM BY PERFORMING A GVI AND TORQUE CHECK OF BLEED SYSTEM IN ENG 2 PYLON, PERFORMED IDLE RUNS NO MESSAGE PRESENT. ALSOFeb 20, 2023 · N915JX · Emb EMB145LR · Pneumatic SystemSDR SIMA20230220002Lamp · inoperativeMAIN DOOR EXT EMERGENCY DOOR LIGHT INOP-C/A-RAR MAIN DOOR EXT EMERGENCY DOOR LIGHT LAMP IAW EMB AMM 33-50-06-000-801-A AND 33-50-06-400-801-A. OPS CHECK GOOD. END.Feb 20, 2023 · N928AE · Emb EMB145LR · Emergency LightingSDR HNAA2023022100050None · noneUNABLE TO PRESSURIZE A/C IN IETHER AUTOMATIC OR MANUAL MODE WITH LIGHT VISIBLE AROUND MAIN PAX DOORFeb 20, 2023 · N685AE · Emb EMB145LR · Cabin Pressure ControllerSDR HNAA2023030800086Unknown · unknownLEVEL 2 CORROSION IN LAV FLOOR GUSSET BETWEEN FRAMES 59-61. REPAIRED IAW EMB145 SRM 51-10-03, 51-40-02, 51-20-03, AND 53-24-10ADFeb 19, 2023 · N683AE · Emb EMB145LR · Aircraft StructuresSDR HNAA2023031100077Unknown · unknownLEVEL 2 CORROSION IN GALLEY FLOOR LH CROSSBEAM AT FRAME 18. REPAIRED IAW EMB145 SRM 51-40-02, 51-20-01, AND 51-21-06.Feb 19, 2023 · N683AE · Emb EMB145LR · Standard Practices/StructuresSDR HNAA2023030800068Unknown · unknownLEVEL 2 CORROSION ON CROSS BEAM BRACKET BETWEEN LH FLOOR GUSSET AND LH FLOOR SIL IN LAV AREA BETWEEN FRAMES 60-61. REPAIRED IAW EMB145 SRM 51-20-03 AND 51-40-02.Feb 19, 2023 · N683AE · Emb EMB145LR · Standard Practices/StructuresSDR HNAA2023030800067Unknown · unknownLEVEL 2 CORROSION ON SPLICE BRACKET ON LH FLOOR SILL IN LAV BETWEEN FRAMES 60-61. REPAIRED IAW EMB145 SRM 51-20-03, AND 51-40-02.Feb 19, 2023 · N683AE · Emb EMB145LR · Standard Practices/StructuresSDR HNAA2023030800066None · noneLEVEL 2 CORROSOIN IN LAV FLOOR GUSSET BETWEEN FRAMES59-61. REPAIRED IAW EMB145 SRM 51-10-03, 53-24-10AD, 51-40-02, AND 51-20-03.Feb 19, 2023 · N683AE · Emb EMB145LR · Standard Practices/StructuresSDR HNAA2023022200052None · noneCORROSION BETWEEN STRINGER 17L AT FRAME 60-61. REPARIED IAW EO1-53-23-0043 DAMAGE WAS ON STRINGER SECTION THAT WAS REPLACEDFeb 19, 2023 · N639AE · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20230219001Sign · inoperativeDURING PS-1 CHECK FOUND AFT EMERGENCY OVERHEAD EXIT SIGN AFT SIDE INOP-C/A-RAR AFT EMERGENCY OVERHEAD EXIT SIGN ON THE AFT SIDE IAW AMM 33-50-15. OPS CHECK GOODFeb 19, 2023 · N663AR · Emb EMB145LR · Emergency LightingSDR SIMA20230217002Lamp · inoperative12A PSU EMERRGENCY LIGHT INOP-C/A-RAR 12A PSU EMERGENCY LIGHT LAMP IN REFERENCE WITH EMB AMM 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. END.Feb 17, 2023 · N931AE · Emb EMB145LR · Emergency LightingSDR HNAA2023030800065Unknown · unknownLEVEL 2 CORROSION ON LH #3 FLOOR SILL. REPAIRED IAW EMB145 SRM 51-40-02, 51-20-03, AND 51-40-09Feb 16, 2023 · N683AE · Emb EMB145LR · Standard Practices/StructuresSDR HNAA2023021600049None · noneMUSTY SMELL FROM PACK 2 IN FLIGHT DECK.Feb 15, 2023 · N672AE · Emb EMB145LR · Cabin Cooling SystemSDR V0XD20230215001Seat Track · corrodedLH FLOOR SEAT TRACK HAS MULTIPLE SIGNS OF CORROSION AT FR 47- FR 53. CORRECTIVE ACTION: REMOVED AND REPLACED LH FLOOR SEAT TRACK AT FR 47- FR 53 IAW EMB 135/145 AMM 53-01-06.Feb 15, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR HNAA2023021500047Unknown · unknownPDIS 639 36-11 2907393 14FEB23 CLT CLOSE ON TAKE OFF ROLL RECIEVED HS VLV FAIL ON EICAS. DID NOT KNOW WHICH SIDE SUSPECT ENGINE 2. 30123 00 AKR FACT 14FEB23 19:29 CLT UPON ARRIVAL TFeb 14, 2023 · N639AE · Emb EMB145LR · Pneumatic Distribution SystemSDR SIMA20230214001Flashlight Assy · brokenAFT EMERGENCY FLASHLIGHT NOT CHARGING-C/A-RAR AFT EMERGENCY FLASHLIGHT BRACKET ASSEMBLY IN REFERENCE WITH EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPC GOOD. END.Feb 14, 2023 · N663AR · Emb EMB145LR · Emergency LightingSDR V0XD20230214003Seat Track · corrodedLH FLOOR SEAT TRACK HAS MULTIPLE SIGNS OF CORROSION FR 36 TO FR 47. CORRECTIVE ACTION: REMOVED AND REPLACED SEAT TRACK AT FR 36 TO FR 47 IAW EMB 135/145 AMM 53-01-06.Feb 14, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230214002None · corrodedLH SIDE FLOOR SILL AT FR 59- FR 65 HAS SIGNS OF CORROSION IN MULTIPLE SPOTS. CORRECTIVE ACTION: REMOVED AND REPLACED 2 EA FLOOR SILLS ON L/H AT FR 59- FR 65 IAW EMB 135/145 SRM 51-40-02.Feb 14, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230214001None · corrodedLH SIDE FLOOR SILL AT FR 59- FR 65 HAS SIGNS OF CORROSION IN MULTIPLE SPOTS. CORRECTIVE ACTION: REMOVED AND REPLACED 2 EA FLOOR SILLS ON L/H AT FR 59- FR 65 IAW EMB 135/145 SRM 51-40-02.Feb 14, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230213004Seat Track · corrodedLH FLOOR SEAT TRACK HAS MULTIPLE SIGNS OF CORROSION FR 53- FR 59. CORRECTIVE ACTION: REMOVED AND REPLACED LH FLOOR SEAT TRACK AT FR 53- FR 59 IAW EMB 135/145 AMM 53-01-06.Feb 13, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR HNAA2023030800062Unknown · unknownLEVEL 2 CORROSOIN ON INTERNAL FUSELAGE REINFORCEMENT SKIN PLATE BETWEEN FRAMES 61-62 STRINGERS 20L-21L. REPAIRED IAW EMB145 SRM 51-40-02 AND SB145-53-0068 FIG 7 DETAIL A2Feb 12, 2023 · N683AE · Emb EMB145LR · Standard Practices/StructuresSDR HNAA2023021300045Unknown · unknownPDIS 657 31-50 2852572 12FEB23 BOS CLOSE DURING TAKEOFF ROLL, SPOILERS OPENED WITH OPEN INDICATION AND AUDIBLE TRIM ANNUNCIATION WITH UNKNOWN MASTER WARNING FACT 12FEB23 22:19 BOS C/W OPS CHECK OF THE SPOILER SYS. AS PER AMM Feb 12, 2023 · N657AE · Emb EMB145LR · Indicating/Recording SystemSDR SIMA20230212001Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP-C/A-RAR SERVICE DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPC GOOD. END.Feb 12, 2023 · N663AR · Emb EMB145LR · Emergency LightingSDR HNAA2023030800063Unknown · unknownLEVEL 2 CORROSION ON INTERNAL FUSELAGE SKIN PLATE BETWEEN FRAMES 62-63 STRINGERS 20L-21L. REPAIRED IAW EMB145 SRM 51-40-02 AND SB145-53-0068Feb 11, 2023 · N683AE · Emb EMB145LR · Standard Practices/StructuresSDR V0XD20230218003Splice · crackedDIGITAL PLATE SPLICE FOUND CRACK LH SIDE FR16. CORRECTIVE ACTION IS TO REPLACE WITH NEW SPLICE IAW EMB 135/145 SRM 51-40-02. AVMAX WO 81031 WC 2435.Feb 10, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230210004Floor Support · corrodedRH FLOOR SILL FR27 TO FR29 HAS MULTIPLE SIGNS OF CORROSION . CORRECTIVE ACTION IS TO REMOVE AND REPLACE FLOOR SILL WITH NEW SILL IAW EMB 135/145 SRM 51-40-02. AVMAX WO 81031 WC 1192.Feb 10, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230210003Floorbeam · corrodedSIGNS OF CORROSION ON CROSSBEAM AND FASTENERS AT LBL15 AND FR18 . CORRECTIVE ACTION IS TO REPLACE CROSSMEMBER AND CORRODED FASTENERS WITH NEW IAW EMB 135/145 SRM 51-40-02. AVMAX WO 81031 WC 1220.Feb 10, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230210002Floor Support · corrodedLH FLOOR SILL FR23 TO FR29 HAS MULTIPLE SIGNS OF CORROSION. CORRECTIVE ACTION IS TO REMOVE AND REPLACE WITH NEW FLOOR SILL IAW EMB 135/145 SRM 51-40-02. AVMAX WO 81031 WC 1207.Feb 10, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230210001Support · corrodedVHF 2 ANTENNA BASE PLATE FWD OF FR 22 HAS SIGNS OF CORROSION. CORRECTIVE ACTION: REMOVED AND REPLACED SUPPORT ASSY ( BASE PLATE) ON VHF 2 ANTENNA FWD OF FR 22 IAW EMB 135/145 SRM 53-21-01 AND SRM 51-40-02.Feb 10, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230209001Support · corrodedL/H SIDE FLOOR SILL AT FR 68- FR 71 HAS SIGNS OF CORROSION IN MULTIPLE SPOTS. CORRECTIVE ACTION: REMOVED AND REPLACED DAMAGED L/H SIDE FLOOR SILL FROM FR 68- FR 71 IAW EMB 135/145 SRM 51-40-02.Feb 9, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR HNAA2023021600048None · noneUPON APU START BURNING SMELL IN FLIGHT DECK AND CABIN.Feb 8, 2023 · N691AE · Emb EMB145LR · APU Cowling/ContainmentSDR SIMA20230208002Battery · unserviceableBOTH OVERWING EMERGENCY LIGHTS INOP-C/A-RAR #4 EMERGENCY LIGHT BATTERY IAW MM 33-50-04 OPS CHECK GOODFeb 8, 2023 · N622AE · Emb EMB145LR · Emergency LightingSDR 4DPA2023020700001Unknown · unknownISSUE- CREW REPORTED ON CLIMB OUT BLD2 LEAK, FOLLOWED QRH AND LEAK EXTINGUISHED OPERATING AT F250 DIVERTED TO ORF. CORR ACTION- MX INITIALLY DEFERRED BLEED 2 SYSTEM AND ONCE TROUBLESHOT FOUND LOOSE CLAMPS AT ACM TRIGGERING BLEED LEAK. TIGHTENED CLAMPS LEAK ANDFeb 7, 2023 · N915JX · Emb EMB145LR · Pneumatic SystemSDR V0XD20230207004Floor Support · corrodedRH FLOOR SILL FROM FR48 TO FR52 HAS MULTIPLE SIGNS OF CORROSION. CORRECTIVE ACTION IS TO REMOVE AND REPLACE WITH NEW FLOOR SILL IAW EMB 135/145 SRM 51-40-02. AVMAX WO 81031 WC2335.Feb 7, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230207003Gusset · corrodedFLOOR BEAM GUSSET PLATE AT FR59-FR61 0BL HAS MULTIPLE SIGNS OF CORROSION. CORRECTIVE ACTION IS TO REMOVE AND REPLACE WITH NEW GUSSET PLATE IAW EMB SRM 51-40-02 AND SRM 51-20-03. AVMAX WO 81031 WC 1197.Feb 7, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230207002Floorbeam · corrodedFLOOR BEAM AT BL0 AND FR59 HAS SIGNS OF CORROSION AT NUTPLATE AND GUSSET. CORRECTIVE ACTION IS TO CUTOUT DAMAGE AREA 1 INCH BY 1 INCH AND CUTOUT NEW FILLER FORM DOUBLER AND REPAIR IAW EMB 135/145 SRM 53-24-10 AND ETD 2023-145-001-702. AVMAX WO 81031 WC 1232.Feb 7, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230207001Floor Support · corrodedRH FLOOR SILL FR35 TO FR41 HAS MULTIPLE SIGNS OF CORROSION. CORRECTIVE ACTION IS TO REMOVE AND REPLACE WITH NEW FLOOR SILL IAW EMB 1356/145 53-23-10. AVMAX WO 81031 WC2333.Feb 7, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR 4DPA2023020600001Clamp · failedISSUE-CREW REPORTED ON CLIMB OUT AT FL180, PERFORMED ICE DETECTION TEST WITH NORMAL PARAMETERS. TESTED OK, WENT BACK TO ICE DETECTION AUTO. ENG 1 A/ICE FAIL EICAS DISPLAYED. ENG 1 ICE VALVE STAYED OPEN. RAN QRH AND MESSAGE PERSISTED. A/ICE FAIL MESSAGE ANFeb 6, 2023 · N247JX · Emb EMB145LR · Ice/Rain Protection SystemSDR SIMA20230205002Lamp · inoperativeRH AND LH OVERWING EMERGENCY LIGHT INOP-C/A-RAR RH AND LH OVERWING EMERGENCY LIGHT LAMP WITH REFERENCE TO EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.Feb 5, 2023 · N935AE · Emb EMB145LR · Emergency LightingSDR SIMA20230205001Not Reported · not reportedON CLIMBOUT LANDING GEAR DISAGREE / DECLARED EMERGENCY OVRWT LNDG / EQP SWAP FLT CONT. LANDING GEAR DISAGREE WARNING MESSAGE AFTER GEAR RETRACTION. FOLLOWED QRH UPON EXTENSION ALL GREEN DOWN AND LOCKED. GEAR RETRACTION GOT LND GEAR DISAGREE AGAIN WITH REG NOSEFeb 5, 2023 · N668HH · Emb EMB145LR · Landing Gear Retraction/Extension SystemSDR SIMA20230205003Not Reported · not reportedFA REPORTED SMOKE COMING FROM UNDER ROW 9/10. TURNED OFF BOTH PACKS AND SMOKE STOPPED *DURING TAXI TO THE GATE* ON APU BLEED NO ODOR NOTICED "TRANSFERRED TO NRWC 661-DFW-06888"-C/A-REF LOG PAGE 4797560 ITEM 2. WHILE PERFORMING ETN TRIAD WORKSCOPE FOUND RECIRCUFeb 5, 2023 · N661JA · Emb EMB145LR · Air Distribution SystemSDR V0XD20230204001Seat Track · corrodedLH SIDE SEAT TRACK HAS MULITPLE SIGNS OF CORROSION AT FR 36- FR 47. CORRECTIVE ACTION: REMOVED AND REPLACED SEAT TRACK FROM FR 36- FR 47 L/H SIDE IAW EMB 135/145 AMM 53-01-06.Feb 4, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230204006Floor Support · corrodedLH FLOOR SILL FR29 TO FR35 HAS MULTIPLE SIGNS OF CORROSION. CORRECTIVE ACTION IS TO REMOVE AND REPLACE IAW EMB 135/145 SRM 51-40-02. AVMAX WO 81031 WC 1206.Feb 4, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230204005Seat Track · corrodedLH SIDE SEAT TRACK HAS MULTIPLE SIGNS OF CORROSION FROM FR53 TO FR59. CORRECTIVE ACTION IS TO REMOVE AND REPLACE SIDE SEAT TRACK IAW EMB 135/145 AMM 53-01-06.Feb 4, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230204004Floor Support · corrodedRH FLOOR SILL HAS MULTIPLE SIGNS OF CORROSION FR29 TO FR35. CORRECTIVE ACTION IS REMOVE AND REPLACE IAW EMB 135/145 51-40-02. AVMAX WO 81031 WC 1193.Feb 4, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)SDR V0XD20230204003Seat Track · corrodedLH SIDE SEAT TRACK HAS MULTIPLE SIGNS OF CORROSION. CORRECTIVE ACTION IS REMOVE AND REPLACE WITH NEW SEAT TRACK IAW EMB 135/145 AMM 53-00-11. AVMAX WO 81031 WC 2360.Feb 4, 2023 · N14573 · Emb EMB145LR · Fuselage Structure (General)
Back to Embraer EMB-145LR