Embraer EMB-145XR
Service difficulty reports · 9,191
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145XR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145XR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20251006010Precooler · no testLH ENG BLEED AIR PRECOOLER FAILED PRESSURE TEST. LH PRECOOLER REMOVED AND REPLACED.SDR C1CB2025090800628Warning Message · false activationAFTER DEPARTURE AND DURING THE CLIMB OUT, N284CP EXPERIENCED MULTIPLE AMBER MAINTENANCE MESSAGES THAT INCLUDED #1/2 RUDDER SYS INOP, AUTOPILOT INOP AND PITCH TRIM INOPERATIVE. THE CREW HELD ALTITUDE AT 16,000FT TO PERFORM THE STEPS IN THE QRH TO CLEAR THE MESSDR JJBA20251024062Floor Support · corrodedCORROSION FOUND ON CENTER OMEGA BIN GUSSET, BETWEEN FRAMES 59 & 61. INSTALLED NEW GUSSET BETWEEN FRAMES 59 & 61.SDR JJBA20251010042Fuel Tank · corrodedSURFACE CORROSION ON VENTRAL FUEL TANK EXTERNAL FWD FACE AROUND FUEL VENT TUBE BRACKET. AFTER INVESTIGATION, NO CORROSION FOUND ON BRACKET, ONLY ON RIB I OF VENTRAL TANK. SURFACE BLENDED AND FOUND OUT OF LIMIT. VENTRAL TANK ON RIB I CUT OUT PERFORMED. VENTRAL SDR JJBA20251006008Shear Tie · crackedCFII, SHEAR CLIP AT FR25 BTW FR 15R-16R FOUND CRACKED. CFII AT FR 25 BTW STR 15R-16R SHEAR CLIP REMOVED AND REPLACED.SDR JJBA20251002003Support · corrodedCFII, RT SILL NR 1 BTW FR 23-30 FOUND CORRODED. CFII, RT SILL NR 1 BTW FR 23-30 BLENDED, FOUND OUT OF LIMIT AND REMOVED FOR REPLACEMENT. CFII, RT SILL NR 1 BTW FR 23-30 IS REPLACED.SDR JJBA20250918029Shear Tie · crackedCFII, SHEAR CLIP AT FR24 BTW STR 15R-16R FOUND CRACKED. CFII AT FR24 BTW STR 15R-16R SHEAR CLIP REMOVED FOR REPLACEMENT. CFII AT FR24 BTW STR 15R-16R SHEAR CLIP REPLACEDSDR JJBA20250918028Shear Tie · crackedCFII, SHEAR CLIP AT FR26 BTW STR 15R-16R FOUND CRACKED. CFII AT FR26 BTW STR 15R-16R SHEAR CLIP REMOVED FOR REPLACEMENT. CFII AT FR26 BTW STR 15R-16R SHEAR CLIP REPLACEDSDR JJBA20250918027Shear Tie · crackedCFII, SHEAR CLIP AT FR27 BTW STR 15R-16R FOUND CRACKED. CFII AT FR27 BTW STR 15R-16R SHEAR CLIP REMOVED FOR REPLACEMENT. CFII AT FR27 BTW STR 15R-16R SHEAR CLIP REPLACEDSDR JJBA20250911016Gusset · corrodedCENTER OMEGA BEAM GUSSET FROM FRAME 22 TO FRAME 27 IS CORRODED. CENTER OMEGA BEAM GUSSET AT FRAME 22 - FRAME 27 FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED CENTER OMEGA BEAM GUSSET.SDR JJBA20250911015Gusset · corrodedCORROSION ON GUSSET AT FRAME 16 RBL 4. REMOVED CORROSION ON GUSSET AT FRAME 16 RBL 4 GUSSET FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED GUSSET FROM FRAME 16 RBL 4.SDR JJBA20250911014Gusset · corrodedGUSSET AT FRM 20 RBL 19 IS CORRODED. REMOVED CORROSION FROM FRAME 20 RBL 19, FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED GUSSET.SDR JJBA20250911010Skin · crackedEXTERNAL REAR FUSELAGE SKIN, DENT FOUND 8 INCHES AFT FRAME 77, BTW STR 14L-15L. REPAIR DOUBLER ON LH REAR FUSE II SKIN, BTW FR 77-80 AND BTW STR 13L-16LSDR JJBA20250911009Skin · crackedFF1 RH SKIN CRACKED AT FR 4 AND EDGE OF SKIN AT NLG CUTOUT. REPAIR DOUBLER ON RH FWD FUSE I SKIN, AT FR 4 AND ON LOWER EDGE.SDR JJBA20250908007Lamp · inoperativeROW 18A AND 18CD OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED ROW 18A AND 18CD OVERHEAD EMERGENCY LIGHT LAMPS. OPS CHECK SAT.SDR JJBA20251008021Channel · corrodedCFI, SERVICE DOOR CUT OUT, LOWER CHANNEL BTW FR 20-22 FOUND CORRODED. AT CF1 SERVICE DOOR CUT OUT, LOWER CHANNEL BTW FR 20-22, CHANNEL CORRODED OUT OF LIMIT. CF1 SERVICE DOOR CUT OUT LOWER CHANNEL BTW FR 20-22 REMOVED AND REPLACED.SDR JJBA20251006009Support · corrodedRF1, AFT RADIO ALTEMETER ANTENNA INTERNAL RETAINER BTW FR 68-70 FOUND CORRODED. RFI, AFT RADIO ALTIMETER ANTENNA, INTERNAL RETIANER BTW FR 68-70 BLENDED AND FOUND OF LIMIT. REMOVED AND INSTALLEDSDR JJBA20250924036Floor Support · corrodedCFIII, LH SILL BTW FR 35-42 FOUND CORRODED. CF3, LH SILL BTW FR 35-42 FOUND OUT OF LIMITS. CF3, LH SILL BTW FR 35-42 REMOVED AND REPLACED.SDR JJBA20250922032Floor Support · corrodedCFIII, LH SILL BTW FR 41-48 FOUND CORRODED. CF3, LH SILL BTW FR 41-48 FOUND OUT OF LIMITS. CF3, LH SILL BTW FR 41-48 REMOVED AND REPLACED.SDR JJBA20250917026Doubler · corrodedRIGHT DIGITAL AT FR22 FOUND CORRODED. AT CF1, RT DIGITAL AT FR22 DOUBLER BLENDED OUT OF LIMIT. AT CF1, RT DIGITAL AT FR22 DIGITAL REMOVED AND INSTALLED.SDR JJBA20250911017Floor Support · corrodedRH #1 OB FLOORSILL IS CORRODED. REMOVED AND INSTALLED NEW RH #1 OB FLOORSILL.SDR JJBA20251024066Floor Support · corrodedCORROSION FOUND ON RT OMEGA BIN GUSSET, BETWEEN FRAMES 59 & 61. INSTALLED NEW RT GUSSET PLATESDR JJBA20251008019Gusset · corrodedRIGHT GUSSET IN TOILET AREA BTW FR 59-61 FOUND CORRODED. CFIV, RH GUSSET IN TOILET AREA BTW FR 59-61 BLENDED AND FOUND OUT OF LIMIT. CFIV, RH GUSSET IN TOILET AREA BTW FR 61-59 REMOVED AND REPLACED.SDR JJBA20251006011Doubler · corrodedRFI EXT RADIO ALTEMETER ANTENNA DOUBLER BTW FR 68-70 AND STR 21L-21R FOUND CORRODED. RF1 EXT BTW FR 68-70 AND STR 21L-21R DOUBLER BLENDED AND FOUND OUT OF LIMIT AND REMOVED AND REPLACEDSDR JJBA20251002002Gusset · corrodedCFIII, LT GUSSET BTW FR 35-39 FOUND CORRODED. CF3, LT GUSSET BTW FR 35-39 FOUND OUT OF LIMITS. CFIII, LT GUSSET BTW FR 35-39 REPLACED.SDR JJBA20250929044Gusset · corrodedCFIII, LH GUSSET BTW FR 45-53 FOUND CORRODED. CF3, LH GUSSET BTW FR 45-53 FOUND OUT OF LIMITS. CF3, LH GUSSET BTW FR 45-53 REMOVED AND REPLACED WITH NEWSDR JJBA20250924035Angle · corrodedCFIV, RH STEP ANGLE AT FR59 FOUND CORRODED. CFIV, RH STEP ANGLE AT FR59 BLENDED AND FOUND OUT OF LIMITS. CFIV, RH STEP ANGLE AT FR59 REPLACEDSDR JJBA20250922031Support · corrodedCFIV, RH SILL BTW FR 59-60A FOUND CORRODED. CFIV, RH SILL BTW FR 59-60A BLENDED AND FOUND OUT OF LIMIT. AT CFIV RH BTW FR 59-60A STILL REMOVED AND REPLACEDSDR JJBA20250917025Doubler · corrodedCF1, RH DIGITAL AT FR20 FOUND CORRODED. AT CF1 RH DIGITAL AT FR 20 DIGITAL CORRODED OUT OF LIMIT. AT CF1 RH DIGITAL AT FR DIGITAL REMOVED AND INSTALLED.SDR JJBA20250905002Acm · faultedSMOKE IN COCKPIT AFTER PACK 1 VALVE CLOSED ADVISORY MESSAGE. RAN BOTH PACKS. FOUND #1 PACK SLEEVES LEAKING AT Y DUCT. REMOVED AND REPLACED DUCTS. NO LEAKS NOTED. #2 PACK OVHT ON EICAS. REMOVED AND REPLACED DUAL TEMP CONTROL VALVE. NO FIX. REMOVED AND REPLACED SDR JJBA20250930047Support · corrodedCFIII, RH SILL BTW FR 41-48 FOUND CORRODED. CF3, RH SILL BTW FR41-48 FOUND OUT OF LIMITS. CFIII, RH SILL BTW FR 41-48 REPLACED.SDR JJBA20250925041Floor Support · corrodedLEFT SILL NR 2 BTW FR 23-30 FOUND CORRODED. LT SILL NR 2 BTW FR 23-30 BLENDED AND FOUND OUT OF LIMITS. LT SILL NR 2 BTW FR 23-30 REPLACED.SDR JJBA20250922033Floor Support · corrodedCFIII, RH SILL BTW FR 36-42 FOUND CORRODED. CF3, RH SILL BTW FR 36-42 FOUND OUT OF LIMITS. CF3, RH SILL BTW FR 36-42 REMOVED AND REPLACED.SDR JJBA20250911011Rib · crackedLH AFT MLG WHEEL WELL RIB CRACKED AT UPPER OUTBD CORNER. REMOVED AND REPLACED LH AFT MLG WHEEL WELL RIB.SDR JJBA20251024065Floor Support · corrodedCORROSION FOUND ON LT OMEGA BEAM GUSSET, BETWEEN FRAMES 59 & 61. REMOVED BAD GUSSET BETWEEN FRAMES 59 & 61 LT SIDE AND INSTALLED NEW GUSSETSDR JJBA20250902065Battery Pack · inoperativeNR 1 EMERGENCY LIGHT BATTERY NOT HOLDING CHARGE. REMOVED AND REPLACED NR 1 EMERGENCY BATTERY. OPS CHECK GOOD.SDR JJBA20250911019Gusset · corrodedUNDER LAV ALL 3 GUSSETS ARE CORRODED. REMOVED TWO CORRODED GUSSETS UNDER LAV AND INSTALLED NEW GUSSETS.SDR JJBA20250911018Gusset · corrodedLH IB AND OB GUSSETS UNDER LAV SINK ARE CORRODED. REMOVED LH IB AND OB GUSSETS UNDER LAV SINK AND INSTALLED NEW GUSSETS.SDR JJBA20250911012Floor Support · corrodedFLOORSILL IN CARGO MOST FWD SILL IS CORRODED. REMOVED MOST FORWARD FLOORSILL IN CARGO BAY ON LEFT SIDE AND INSTALLED NEW FLOORSILL.SDR JJBA20250829062Sign · inoperativeEXIT MARKING SIGN AT LH EMERGENCY EXIT UPPER POSITION INOP R/R EXIT MARKING SIGN. OPS CHECK SAT.SDR JJBA20250911013Floor Support · corrodedRH FLOORSILL MOST FWD IN CARGO IS CORRODED. REMOVED RH MOST FORWARD FLOORSILL IN CARGO BAY AND INSTALLED NEW SILL AND PROFILE.SDR JJBA20250825053Battery · dischargedMULTIPLE EMERGANCY LIGHTS OUT. COCKPIT STEP, MAIN DOOR EXIT, AISLE LIGHT 1, MAIN ENTRANCE CEILING, EXIT AISLE CEILING LIGHT 1. R+R EMERGANCY LIGHT BATT 1. OPS CHECK SATSDR JJBA20250904005Fitting · crackedON BAGGAGE DOOR LIFTING AND LOWERING MECHANISM, FWD AND AFT SUPPORTS FOUND WITH CRACKS. BAGGAGE DOOR LIFTING AND LOWERING MECHANISM REMOVED FOR ACCESS. ON BAGGAGE DOOR LIFTING AND LOWERING MECHANISM FWD SUPPORT ANGLE REMOVED FOR REPLACEMENT. ON BAGGE DOOR LIFTSDR JJBA20250822050Charger · inoperativeMAIN CABIN ENTRY EMERGENCY LIGHTS INOP. R/R EMERGENCY BATTERY #1 CHARGER ASSY AND BATTERY.OPS CHK SAT.SDR JJBA20250822049Battery · faultedLH EMERGENCY LIGHT ABOVE PACK PANEL INOP. R & R EMERGENCY BATTERY #1 CHARGER ASSY AND BATTERY.OPS CHK SAT.SDR JJBA20250822048Inverter · faultedEMERGENCY LIGHT ON AFT GALLEY PARTITION INOP. T/S TO FAULTY INVERTER, R&R INVERTER. OP CHECK GOOD, OK FOR CONT SERVICESDR JJBA20250822047Lamp · burned outMCD EXTERNAL EMERG LIGHT INOP. REMOVED AND REINSTALLED MCD EMERG LIGHT. OPS CHECK SAT.SDR JJBA20250822045Elec Connector · faultedFLAP FAIL, SPS ADVANCED EICAS MESSAGE DISPLAYED AFTER MOVING FLAP HANDLE DURING APPROACH. REMOVED AND REPLACED ELECTRICAL CONNECTOR PLUG P1104. FLAPS OPS CHECK GOOD. PERFORMED FLAP SCREWJACK ACTUATOR LUBRICATION ON ALL FLAP ACTUATORS. PERFORMED FLAP SCREWJACK SDR JJBA20250818038Lamp · inoperativeROW 3 AISLE EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED ROW 3 AISLE EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20250818039Pump · inoperativeHYD 2 LOW QTY ON EICAS IN FLIGHT. REMOVED AND REPLACED EDP. PERFORMED OPS CHECK. RAN ENG 2. OPS CHECK GOOD. NO LEAKS NOTED AT THIS TIME. SERVICED #2 HYD.
Back to Embraer EMB-145XR