Embraer EMB-145XR

Service difficulty reports · 9,191

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145XR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JJBA20220206006Not Reported · not reportedPOSSIBLE CORROSION ON CABIN LATERAL FLOOR SUPPORT FRAMES 41-48 STR 15R. REMOVED CORROSION AT LATERAL FLOOR SUPPORT FRAME 41-48 STR 15R.Feb 6, 2022 · N13202 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220206002Not Reported · not reportedEMERGENCY EXIT SIGN OVER WING 18A INDICATES WRONG DIRECTION. REMOVED AND REPLACED EXIT MARKING SIGN ASSEMBLY. OPS CHECK SAT.Feb 6, 2022 · N24128 · Emb EMB145XR · Passenger Compartment WindowsSDR JJBA20220205004Not Reported · not reportedSIGNS OF CORROSION AT MULTIPLE LOCATIONS ON THE GUSSET OF THE OMEGA BEAM Y=429.0 FROM FR 65 TO FR 68. REMOVED CORROSION AT FRAME 65-68 Y-479 BEAM GUSSET.Feb 5, 2022 · N13202 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220203001Charger · inoperativeBOTH OVER WING EMERGENCY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED OVER WING EMERGENCY LIGHT BULB. OPS CHECK FAILED. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY SUPPLY #4. OPS CHECK FAIL. REMOVED AND REPLACED EMERGENCY BATTERY CHARGER ASSEMBLY #4. OPS CHECFeb 3, 2022 · N12157 · Emb EMB145XR · Emergency LightingSDR JJBA20220202013Not Reported · not reportedAT CF 4 AREA, CORROSION FOUND ON CENTER OMEGA BEAM FLOOR STRUCTURE BTW FR 59 TO FR 60. CORROSION ON CENTER OMEGA BEAM BTW FR 59 TO 60 FOUND OUT OF LIMITS. CUT-OUT ON OMEGA BEAM PERFORMED. CENTER OMEGA BEAM BTW FR 59-60 REPAIRED WITH DOUBLERFeb 2, 2022 · N14148 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA2022020431033Coffeemaker · odorFA REPORTS BURNING SMELL FROM COFFEE MAKERS. CLEANED UP COFFEE BREW WARMER, PERFORMED VISUAL INSPECTION COFFEE BREW CRACKS, WIRES. NO DEFECTS NOTED. OPS CHECK GOODJan 31, 2022 · N11107 · Emb EMB145XR · Buffet/GalleysSDR JJBA20220131032Not Reported · not reportedFOUND RH ENGINE FORCED CORE TO BYPASS MIXER CRACKED AT BOLT HOLES #7 AND #1 POSITIONS. REMOVED AND INSTALLED RH ENGINE BYPASS MIXER.Jan 31, 2022 · N17159 · Emb EMB145XR · Engine Exhaust SystemSDR JJBA20220131031Lamp · inoperativeEXTERNAL EMERGENCY MAIN DOOR LIGHT INOPERATIVE. REMOVED AND REPLACED EXTERNAL EMERGENCY MAIN DOOR LIGHT. OPS CHECK SATJan 31, 2022 · N24103 · Emb EMB145XR · Lighting SystemSDR JJBA20220130003Not Reported · not reportedPOSSIBLE CORROSION ON CABIN LATERAL FLOOR SUPPORT FRAMES 35+5 - 41+2 STR 15L. REMOVED CORROSION ON FLOOR SUPPORT FR 35+5 TO FR 41+2 STR 15L.Jan 30, 2022 · N13202 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220130034Not Reported · not reportedRH SPRING TAB RODS CORRODED. REMOVED RUST ON RH SPRING TAB ROD B-NUTJan 30, 2022 · N13202 · Emb EMB145XR · Flight Control SystemSDR JJBA20220128030Light · odorBURNING PLASTIC ODOR COMING FROM COFFEE POTS DURING OPERATION. PERFORMED OPS CHECK OF BOTH COFFEE BREWERS. OPS CHECK SAT. UNABLE TO DETECT ODOR COMING FROM COFFEE BREWERS AND COFFEE BREWER SYSTEM. FOUND NO DEFECTS OR SIGNS OF ARCHING. NOTICED BURNING ODOR COMIJan 28, 2022 · N10156 · Emb EMB145XR · Passenger Compartment LightingSDR JJBA20220123028Not Reported · not reportedMCD EMERGENCY LIGHT INOPERATIVE. REMOVED MCD EMERGENCY LIGHT HOUSING. FOUND BAD GROUND. CLEANED GROUND WIRE RING TERMINAL. REINSTALLED MCD EMERGENCY LIGHT. OPS CHECK SATJan 23, 2022 · N16151 · Emb EMB145XR · Emergency LightingSDR JJBA20220123026Not Reported · not reportedEMERGENCY FLOOR ISLE STRIP BY SEAT 18C AND 20C IS DETACHED FROM FLOOR. RE SECURED EMERGENCY STRIP. NO DEFECTS NOTED AT THIS TIME.Jan 23, 2022 · N11176 · Emb EMB145XR · Emergency LightingSDR JJBA20220121029Lamp · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED COCKPIT EMERGENCY LIGHT. OPS CHECK SATJan 21, 2022 · N11194 · Emb EMB145XR · Emergency LightingSDR JJBA20220121027Battery Pack · inoperativeFWD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY BATTERY PACK. OPS CHECK SATJan 21, 2022 · N21154 · Emb EMB145XR · Emergency LightingSDR JJBA20220120025Glowstrip · missingPHOTO LUMINESCENT STRIP PIECE MISSING ON THE FLOOR NEAR SEAT 3. REPLACED FLOOR EMERGENCY LIGHT STRIP BY SEAT 3Jan 20, 2022 · N17159 · Emb EMB145XR · Emergency LightingSDR JJBA20220116024Container · tornFO'S CREW LIFE VEST HAS A RIP IN BAG. REMOVED AND REPLACED LIFE VESTJan 16, 2022 · N10156 · Emb EMB145XR · Life JacketSDR JJBA202201186020B-Nut · looseHYD SYS 1 FAIL ON EICAS. LH NLG DOOR ACTUATOR HOSE B NUT LOOSE AND LEAKING - RESECURED. REPLENISHED #1 HYD SYSTEM. LEAK AND OPS CHECK SAT.Jan 16, 2022 · N13124 · Emb EMB145XR · Hydraulic System, MainSDR JJBA20220113018Not Reported · not reportedSUPPLEMENTAL (NEW) INFORMATION: AUTO PRESSURIZATION FAIL. R&R MAIN DOOR FRAME SEAL. R&R SIDE HINGED MAIN DOOR RUBBER TRIM SEAL. OPS CHECK SAT.Jan 13, 2022 · N14177 · Emb EMB145XR · Cabin Pressure ControllerSDR JJBA202201183017Frame · damagedFRM 69 HAS DAMAGED NUT PLATE AND ELONGATED HOLE AT STGR 7R. REMOVED DAMAGE HOLE FINAL SIZE D=0.252" AT FRAME 69 STR 7R. FOUND TO BE IN LIMITS.Jan 13, 2022 · N16178 · Emb EMB145XR · Fuselage Main, FrameSDR JJBA20210113019Door · noisyLOUD NOISE COMING FROM UPPER LH CORNER MCD. R&R MAIN DOOR FRAME SEAL. LEAK CHECK SAT AND REINSTALLED MAIN DOOR LINING.Jan 13, 2022 · N14177 · Emb EMB145XR · Cargo/Baggage DoorsSDR JJBA202201183018Cabin Pressure · failedAUTO PRESSURIZATION FAILJan 13, 2022 · N14177 · Emb EMB145XR · Cabin Pressure Control SystemSDR JJBA20220112022Cable · out of limitsLEFT RUDDER AP SERVO CABLE CONNECTION FOUND TO BE OUT OF LIMITS. ADJUSTED LEFT RUDDER AP SERVO CABLE. TENSION CHECK SAT.Jan 12, 2022 · N17185 · Emb EMB145XR · Rudder Control SystemSDR JJBA202201182021Cable · out of limitsRIGHT RUDDER AP SERVO CABLE CONNECTION FOUND TO BE OUT OF LIMITS. ADJSUTED RIGHT RUDDER AP SERVO CABLE. TENSION CHECK SAT.Jan 12, 2022 · N17185 · Emb EMB145XR · Rudder Control SystemSDR JJBA20220110014Not Reported · not reportedREAR FUSELAGE SKIN HAS CORROSION UNDER RAT #2 ANTENNA BASE. CUT OUT DAMAGE ON EXTERNAL SURFACE OF FUSELAGE SKIN AT RAT #2 ANTENNA LOCATION AND INSTALLED REPAIR DOUBLER, FILLER AND SHIMJan 10, 2022 · N16147 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220110011Not Reported · not reportedCORROSION - "Y" - 18 AT FR 23 THRU FR 29 +5 OMEGA BEAM I/B LWR FLANGE - MULTIPLE LOCATIONS. REMOVED AND REPLACED OMEGA BEAM AT FR 23 - FR 29 +5"Jan 10, 2022 · N16147 · Emb EMB145XR · Fuselage Main, BulkheadSDR JJBA20220108006Lamp · inoperativeMCD HINGE FAIRING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED FAIRING EMERGENCY LIGHT LAMP. OPS CHECK SATJan 8, 2022 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20220107013Not Reported · not reportedREAR FUSELAGE SKIN HAS CORROSION UNDER RAR #2 ANTENNA BASE. CUT OUT DAMAGE AT RAR #2 FR68-69 STR 21L-21R AND INSTALLED REPAIR DOUBLER AND FILLERJan 7, 2022 · N16147 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220106016Not Reported · not reportedCORROSION FOUND ON RH OMEGA BEAM AT FR 23 IN CF I FLOOR STRUCTURE AREA. RH OMEGA BEAM AT FR 23 IN CFI FLOOR STRUCTURE BLENDED OUT OF LIMITS FOR CORROSION REMOVAL. PERFORMED CUTOUT AND DOUBLER REPAIR ON RH OMEGA BEAM AT FR23.Jan 6, 2022 · N12135 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220106009Not Reported · not reportedSERVICE DOOR EXTERIOR SKIN, 1 LIGHTNING STRIKE ENTRY POINT SUSPECTED 12" FROM AFT SKIN EDGE AND 13.75 FROM TOP. SERVICE DOOR EXTERIOR SKIN 12" FROM AFT EDGE AND 13.75 FROM TOP EDGE. 1 LIGHTNING STRIKE REPAIRED WITH EXTERNAL DOUBLER.Jan 6, 2022 · N12135 · Emb EMB145XR · Hydraulic Compartment DoorsSDR JJBA20220106008Not Reported · not reportedCF II, EXTERNAL FUSELAGE, LIGHTING STRIKE 1.000 INCH FWD FRAME 27 BTW STR 8R-9R. CFII, EXTERNAL FUSE SKIN, 1 FWD OF FRAME 27 BTW STR 8R-9R, PAINT STRIPPED FOR INVESTIGATION. DOUBLER REPAIR FABRICATED. CFII EXTERNAL SKIN, LIGHTNING STRIKE 1 IN FWD OF FR 27 BTW Jan 6, 2022 · N12135 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220106007Not Reported · not reportedCORROSION FOUND UNDER DATA PLATE ON AFT RF2 EXTERNAL SKIN BTW FR 78-79 AND STR 21L-21R. CORROSION BLENDED OUT OF LIMIT. REAR FUSELAGE II LOWER SKIN BTW FR 80-81 AND BTW STR 21L-21R REPAIRED WITH CUT OUT AND DOUBLER.Jan 6, 2022 · N12135 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220105005Not Reported · not reportedLAV UNDER FLOOR SUPPORT AT FR 59-61 BUT LINE O CORROSION. REMOVED AND REPLACED LAV FLOOR SUPPORT CENTER GUSSET AT FR 59-61Jan 5, 2022 · N16178 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220104003Not Reported · not reportedUNDER BAGGAGE COMP UNDER RADIO ALT 2 CORROSION. REMOVED AND REPLACED UNDER BAGGAGE COMP RADIO ALT #2 ANTENNA SUPPORT.Jan 4, 2022 · N16178 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220103004Not Reported · not reportedALL SEAT TRACKS GOUGED / POSSIBLE CORROSION. BLENDED CORROSION / GOUGES ON ALL SEAT TRACKS LH UPPER, CENTER FLOOR FRAMES 19-59 AND RH UPPER, CENTER FLOOR FROM FRAME 23-59. ALL SEAT TRACKS WITHIN LIMITS. REMOVED AND REPLACED 2 SEAT TRACKS AT FRAME 26-28 LH FLOOJan 3, 2022 · N16178 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220102002Control Unit · inoperativePITCH TRIM BACKUP INOPERATIVE ON EICAS IN FLIGHT. R&R HSCU. ADJUSTMENT TEST CARRIED OUT. REPLACED HAS. OPS CHECK SAT.Jan 2, 2022 · N27190 · Emb EMB145XR · Stabilizer Control SystemSDR JJBA202201020002Control Unit · inoperativePITCH TRIM BACKUP INOPERATIVE ON EICAS IN FLIGHT. R&R HSCU. ADJUSTMENT TEST CARRIED OUT. REPLACED HAS. OPS CHECK SAT.Jan 2, 2022 · N27190 · Emb EMB145XR · Elevator Tab Control SystemSDR JJBA20220101001Pump · leakingE1 HYD PUMP FAIL ON EICAS AFTER TAKE OFF. REMOVED AND REPLACED #1 EDP. OPS CHECK AND LEAK CHECK SAT AT THIS TIMEJan 1, 2022 · N12201 · Emb EMB145XR · Hydraulic Power SystemSDR JJBA20211231048Not Reported · not reportedSERV DOOR SILL AND UNDER DOOR SILL AC SKIN CORROSION. REMOVED AND REPLACED DOOR SILL AT SERVICE DOORDec 31, 2021 · N16178 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20211231047Not Reported · not reportedLAV UNDER FLOOR SUPPORT AT FR 59-61 STR 17L HAS CORROSION. REMOVED AND REPLACED LAV UNDERFLOOR, FLOOR SUPPORT AT FR 59-61 STR 17LDec 31, 2021 · N16178 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20211231046Not Reported · not reportedUNDER LAV FLOOR SUPPORT CORROSION BEAM FR 60 STR 17L. REPAIRED UNDER LAY FLOOR SUPPORT FLOOR BEAM FR 60 STR 17LDec 31, 2021 · N16178 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20211231045Not Reported · not reportedUNDER BAGGAGE COMP UNDER RADIO REC #2 CORROSION. PERFORMED PERMANENT REPAIR UNDER BAGGAGE COMPARTMENT UNDER RADIO REC #2 SKIN.Dec 31, 2021 · N16178 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20211231043Lamp · inoperativeSIDE HINGED MAIN DOOR EXTERNAL EMERGENCY LIGHT NOT WORKING. REMOVED AND REPLACED EXTERNAL EMERGENCY DOME LIGHT ASSEMBLY AND BULB. OPS CHECK SATDec 31, 2021 · N12201 · Emb EMB145XR · Emergency LightingSDR JJBA20211231042Battery Pack · inoperativeNUMBER ONE EMERGENCY LIGHT BATTERY INOPERATIVE. REMOVED AND REPLACED #1 EMERGENCY LIGHT BATTERY. OPS CHECK SATDec 31, 2021 · N11192 · Emb EMB145XR · Emergency LightingSDR JJBA20211229049Not Reported · not reportedLATERAL FLOOR SUPPORT STR 15R FRAMES 52-57, 45-47, 23-41 CORROSION. LATERAL FLOOR SILL SUPPORT STR 15R FRAMES 52-57, 45-47, 23-41. REMOVED CORROSION AND REMOVED AND REPLACED SILL SUPPORT.Dec 29, 2021 · N16178 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20211228044Not Reported · not reportedRH HAT BEAM AT Y + 479.0 FOUND TO HAVE SIGNS OF CORROSION AFTER REMOVAL OF GUSSET FROM FRM 59-61. FAB 2 REPAIR DOUBLER AND INSTALLED ON RH BEAM FR 49-61.Dec 28, 2021 · N16178 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20211228041None · noneRAR #2 ANTENNA BASE HAS SIGNS OF CORROSION. REMOVED CORROSION AT RAR #2 ANTENNA BASE, FOUND CRACKS, CUTOUT DAMAGE AREA AND PERFORMED REPAIR. THIS REPAIR IS CONSIDERED TEMPORARYDec 28, 2021 · N11193 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20211228040None · noneRAD ALT 2, ANTENNA HAS SIGNS OF CORROSION. REMOVED AND REPLACED ANTENNA SUPPORT.Dec 28, 2021 · N11193 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20211228038Unknown · odorELECTRICAL SMELL IN COCKPIT DURING TAKEOFF AND CLIMB PHASES. OPS CHECK FAILED FOR PACK 1 HAD OVERHEAT MESSAGE DURING PACK 1 POWER RUNS ALTHOUGH NO ELECTRICAL SMELLS. NO CMC MESSAGES FOUND AT THIS TIME. PERFORMED HIGH POWER RUNS WITH PACK 2 WITH NO SMELLS OR MEDec 28, 2021 · N21154 · Emb EMB145XR · Air Distribution SystemSDR JJBA20211228037None · noneOVERWING EMERGENCY EXIT COVERS ARE LOOSE. RESECURED EMERGENCY EXIT COVERSDec 28, 2021 · N14173 · Emb EMB145XR · Emergency Lighting
Back to Embraer EMB-145XR