Embraer Executive EMB-505
Service difficulty reports · 1,956
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB505' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB505' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR E07A201805210001Battery Pack · failedAIRCRAFT EMERGENCY LIGHTS FLASHES ON AND OFF WITH SYSTEM IN THE ARM POSITION. REPLACED THE BATTERY PACK.SDR E07A201805210006Brake · warning messageON FIRST LANDING AFTER EMERGENCY PARKING BRAKE VALVE WAS CHANGED. CREW RECEIVED A PARK BRAKE SET WARNING AND CAS MESSAGES DURING LANDING ROLL OUT WHEN READY AIRCRAFT TOE BRAKES WAS APPLIEDSDR E07A201805210005Valve · leakingDURING PREFLIGHT CHECK. EMERGENCY BRAKE PRESSURE FOUND TO BE ZERO. PERFORMED A PRESSURE RECHARGE PROCEDURE. WITH PARK BRAKE SET THE EMERGENCY BRAKE PRESSURE CONTINUED TO BLEED DOWN. WITH PARK BRAKE RELEASED THE EMERGENCY BRAKE PRESSURE DECREASED RAPIDLY. REPSDR DXTA201804260879Warning Message · multiple failRECEIVED A FLAP FAIL, SWPS FAULT, PTRIM BKP FAIL, AND SPOILER FAULT CAS MESSAGES ALONG WITH MAX SPD ABOVE THE AIRSPEED TAPE AND A DATA PATH HAS FAILED MESSAGE ON THE GTC. HAD AN X OVER THE FLAP INDICATION ON THE MFD. ALL THIS CAME ON AT THE INSTANT THE VS MSDR DXTA2018042000859Warning Message · false activationBOTH FLAP EXTENSION FAIL, FCE FAULT. DURING CLIMB, AUTOPILOT DISENGAGED AND SWPS FAULT AND SPOILER FAULT CAS MESSAGES DISPLAYED. PERFORMED A FLAP SYSTEM OPERATIONAL CHECK IAW MM 27-50-00. OPS CHECKED GOOD, NO ACTIVE FAULT MESSAGES DISPLAYED. CONSIDERED TRASDR DJFA201804262001Actuator · failedPITCH TRIM ACTUATOR LEAKING OIL. REMOVED AND REPLACED THE PITCH TRIM ACTUATOR IAW AMM 27-41-01.SDR DXTA2018033000783Unknown · odorUNFAMILIAR ODOR NOTICED ABOVE 10,000 FEET. WENT AWAY FOR A WHILE THEN IT CAME BACK WHEN ABOUT TO LEVEL OFF AT FLIGHT LEVEL 410. ODOR SMELLS LIKE BURNING OIL COMING THROUGH ENVIRONMENTAL SYSTEM. PRESSIRIZED AIRCRAFT AND RAN THE LT AND RT ENGINES AT CLIMB CRUSDR DJFA20180328001Starter Gen · failedAIR TURN BACK DUE TO A VIBRATION SHORTLY AFTER TAKEOFF FOLLOWED BY GEN1 FAIL APPROX 90 SEC LATER. AIRCRAFT LANDED WITHOUT INCIDENT. R&R STARTER/GEN. OPS CHECK GOOD. NO OTHER DEFECTS NOTED.SDR DXTA2018032600766Brake Sys · contaminatedBRAKES WERE APPLIED EVENLY AFTER TOUCHDOWN. BRAKES APPEARED TO QUIT BELOW 40 KNOTS AND THEN STARTED WORKING AGAIN AT A SLOWER SPEED. OVERALL BRAKES FEEL SOFT. SUP: COMPLIED WITH BRAKE ASSY GVI IAW AMM 32-41-60. NO LEAKS OR DEFECTS NOTED. COMPLIED WITH MAIN BSDR DXTA2018032400758Precooler · failedBLEED 1 FAIL YELLOW CAS ILLUMINATED, CLIMBING THROUGH APPROXIMATELY 16,000 FT IN ICING CONDITIONS WITH WING AND ENGINE ANTI-ICE SWITCHES SELECTED ON. AFFECTED BLEED FAIL CONDITION DID NOT INITIALLY RESET. BLEED 2 FAIL YELLOW CAS MESSAGE ILLUMINATED CLIMBINGSDR DJFA20180426661Actuator · failedDURING FLIGHT AT FL450 THE PTRIM NML FAIL CAS CAME ON. SWAPPED FCE. REMOVED AND REPLACED PITCH TRIM ACTUATOR. OPS CHECKED GOOD.SDR DXTA2018031900726Interface Unit · faultedMULTIPLE AIRFRAME AND ENGINE CAS MESSAGES IN-FLIGHT INCLUDING, LG LEVER DISAG, E1 TTO HTR FAIL, PRESN AUTO FAIL, OXY LOW PRES, A-I E2 ON, A-I E1 ON, SWPS ICE SPEED, A-I WINGSTB ON, ADS 2 SLIP FAIL, ADS 1 SLIP FAIL, AND ENG NO DISPATCH. REMOVED AND REPLACED SDR E07A201803120004Precooler · damagedBLEED 1/2 FAIL. IAW SIL505-36-0003 INSPECTED THE ENGINE PRECOOLER AND FOUND THE INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER.SDR E07A201803120003Precooler · damagedBLEED 1/2 FAIL. IAW SIL505-36-0003, INSPECTED THE ENGINE PRECOOLER AND FOUND THE INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER.SDR E07A201803120002Precooler · damagedBLEED 1/2 FAIL. IAW SIL505-36-0003, INSPECTED THE ENGINE PRECOOLER AND FOUND THE INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER.SDR E07A201803120001Precooler · damagedBLEED 1/2 FAIL. IAW SIL505-36-0003, INSPECTED THE ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER.SDR E07A201803060006Vane · failedINSPECTED LT ENGINE PRECOOLER IAW SIL505-36-0003 REV 2. FOUND BOTH PRECOOLER DIVERTER VANES CRACKED AND BROKEN OFF. DIVERTER VANES FOUND LAYING ON TOP OF PRECOOLER EXCHANGER BLOCKING INLET AIR TO PRECOOLER.SDR E07A201803060005Vane · failedBLEED 1 & 2 FAILED. INSPECTED ENGINE PRECOOLER IAW SIL505-36-0003 AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER.SDR E07A201803060002Precooler · failedINSPECTED THE LT ENGINE PRECOOLER IAW SIL505-36-0003 REV 2. FOUND BOTH PRECOOLER DIVERTER VANES CRACKED AND BROKEN OFF. DIVERTER VANES FOUND LAYING ON TOP OF PRECOOLER EXCHANGER BLOCKING INLET AIR TO PRECOOLER. DIVERTER VANES WERE REMOVED COMPLETELY AND GRSDR E07A201803060001Precooler · failedBLEED 1/2 FAIL. IAW SIL505-36-0003 INSPECTED THE ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER. REPLACED.SDR E07A201803060004Vane · failedINSPECTED THE LT ENGINE PRECOOLER IAW SIL 505-36-0003, REV 2. FOUND BOTH PRECOOLERS DIVERTER VANES CRACKED AND BROKEN OFF. THE DIVERTER WERE VANES FOUND LAYING ON TOP OF PRECOOLER EXCHANGER BLOCKING INLET AIR TO PRECOOLER.SDR E07A201803060003Precooler · failedINSPECTED RT ENGINE PRECOOLER IAW SIL505-36-0003, REV 2. FOUND BOTH PRECOOLER DIVERTER VANES CRACKED AND BROKEN OFF. DIVERTER VANES FOUND LAYING ON TOP OF PRECOOLER EXCHANGER BLOCKING INLET AIR TO PRECOOLER. THE DIVERTER VANES WERE REMOVED COMPLETELY AND GRSDR E07A201803060007Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON.SDR DJFA20180226001Starter Gen · malfunctionedNR 2 GEN TRIPPED OFFLINE AND WOULD NOT RESET. VIBRATION WAS FELT IN NR 2 ENGINE. REMOVED AND REPLACED NR 2 STARTER GEN WITH OVERHAULED PER AMM 24-31-01 COMPLIED WITH STATER GENERATOR UNSCHEDULED REMOVAL TASK 05-50-00-810-821. OPERATIONAL CHECK SATISFACTORY. LESDR E07A201912020002Precooler · crackedCRACKED LH ENGINE PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION. REPLACED WITH OVERHAULED UNIT.SDR E07A201912020001Precooler · crackedCRACKED RH ENGINE PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION. REPLACED WITH OVERHAULED UNIT.SDR E07A201802230004Baffle · brokenBLEED 1/2 FAIL. IAW SIL505-36-0003 INSPECTED ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLERSDR E07A201802230003Baffle · brokenBLEED 1/2 FAIL. PER SIL505-36-0003 INSPECTED ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER.SDR E07A201802230002Precooler · damagedBLEED 1/2 FAIL. PER SIL505-36-0003 INSPECTED ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLERSDR E07A201802230001Precooler · damagedBLEED 1/2 FAILED IAW SIL505-36-0003. INSPECTED RT ENGINE PRECOOLER PER SIL505-36-0003 REV 2 AS PART OF A VOLUNTARY EXECUTIVE AIRSHARE FLEET CAMPAIGN. FOUND BOTH PRECOOLER DIVERTER VANES CRACKED AND BROKEN OFF. DIVERTER VANES FOUND LAYING ON TOP OF PRECOOLER ESDR DXTA2018022300629Unknown · odorELECTRICAL ODOR COINCIDING WITH THE GEN2 FAIL MESSAGE. PERFORMED FIM4885 21-20-00-810-801A SMOKE/ABNORMAL ODOR IN THE CABIN/COCKPIT-UNKNOWN SOURCE. OPERATED ACS FOR 30 MIN, LO MED AND HI. NO UNUSUAL SMELLS NOTED. RAN RT ENGINE ON RT BLEED ONLY FOR 30 MINUTESDR XMXR2018022200001Precooler · brokenDURING ROUTINE INSPECTION OF RT PRE-COOLER ASSEMBLY FOUND INTERNAL VANES BROKEN OFF RT PRE-COOLER ASSEMBLY BLOCKING AIRFLOW OVER COOLING FINS. AFTER MORE RESEARCH FOUND HAS A SERVICE LETTER ADDRESSING THIS ISSUE. SL 505-36-0003. AFFECTED RT PRE-COOLER P/N 1096SDR XMXR2018022200002Precooler · brokenDURING ROUTINE INSPECTION OF PRE-COOLER ASSEMBLY FOUND INTERNAL VANES BROKEN OFF PRE-COOLER ASSEMBLY BLOCKING AIRFLOW OVER COOLING FINS. AFTER MORE RESEARCH FOUND HAS A SERVICE LETTER ADDRESSING THIS ISSUE. SL 505-36-0003. AFFECTED PRE-COOLER P/N 10965000-105 SDR E07A201802230006Baffle · brokenBLEED 1/2 FAIL. IAW SIL505-36-0003 INSPECTED ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER. REPLACED PRECOOLER ASSY.SDR E07A201802230005Baffle · brokenBLEED 1/2 FAIL. PER SIL505-36-0003 INSPECTED ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER.SDR DJFA20180216001Actuator · failedPITCH TRIM NORMAL FAIL CAS MESSAGE AT HIGH ALTITUDE. WHEN BACKUP TRIM ENGAGED PTRM BKP FAIL CAS MESSAGE. TRIM FULL DOWN AT 14.1. REPLACED THE PITCH TRIM ACTUATOR. OPS CHECKED GOOD. R & R TELESCOPING DUCT O-RING SEALS. LEAK CHECKED GOOD.SDR E07A201802140006Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON.SDR E07A201802140016Bearing · damagedENROUTE, CREW RECEIVED A NR 2 GENERATOR OFFLINE, WITH VIBRATION. ENGINE THROTTLED BACK TO IDLE. VIBRATION STILL PRESENT. CREW PERFORMED PRECAUTIONARY ENGINE SHUTDOWN IAW QUICK REFERENCE HANDBOOK AND DIVERTED. RT STARTER FOUND WITH BEARING DAMAGE.SDR E07A201802120009Valve · leakingAFTER BRAKE RELEASE. PARK BRAKE LIGHT STAYS ON OR IS INTERMITTENT COMING ON.SDR E07A201802120008Valve · leakingAFTER BRAKE RELEASE. PARK BRAKE LIGHT STAYS ON OR IS INTERMITTENT COMING ON.SDR E07A201802140012Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON.SDR E07A201802140011Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ONSDR DXTA2018020500549Control Handle · failedON GEAR RETRACTION THE MLG LEVER WAS PLACED IN THE UP POSITION. RECEIVED A RED CAS MESSAGE FOR LG LEVER DISAGREE. HAD THREE RED DOWN INDICATORS. RAN THE MLG LEVER DISAGREE CHECKLIST, CYCLED THE HANDLE DOWN CAS MESSAGE CLEARED AND RETURNED FOR LANDING. REMOSDR E07A201802140015Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON.SDR DJFA20180125002Actuator · malfunctionedPITCH TRIM NORMAL FAIL, CAS MESSAGE ILLUMINATED ON CLIMB PASSING 16,000FT. REPLACED THE STAB TRIM ACTUATOR WITH REPAIRED UNIT. REPLACED FCE NR 2 WITH MODIFIED UNIT. OPS CHECKED GOOD AND NO DEFECTS NOTED.SDR DJFA20180125001Warning Message · false activationPASSING FLIGHT LEVEL 390, PTRIM NML FAIL, CAS MESSAGE ILLUMINATED AND REMAINED ON FOR REMAINDER OF FLIGHT. OPS CHECK GOOD AT THIS TIME.SDR DXTA2018012500512Unknown · odorCOCKPIT ODOR DURING CLIMB OUT. PERFORMED VISUAL INSPECTION FOR ANY WET INSULATION BLANKETS AND SURROUNDING AREA AROUND LAV, NO DEFECTS NOTED. RAN ENGINES FOR 1 HOUR CHANGED POWER LEVELS TO TRY AND DUPLICATE ODOR. NO DEFECTS NOTED, ALL WORK PERFORMED IAW MM SDR DXTA2018012400509Unknown · odorDETECTED A BURNING ODOR IN THE COCKPIT, SHORTLY AFTER TAKEOFF WITH THE COCKPIT TEMP CONTROL ABOUT 10 O'CLOCK. NOTICED A BURNING RUBBER ODOR. WE PUT THE TEMP CONTROL TO FULL COLD AND THE ODOR STARTED TO DISSIPATE. WENT TO FULL COLD AND THE ODOR EVENTUALLY WESDR 6EER20180118002O-Ring · missingTHE RT WING TANK FUEL DRAIN WAS FOUND TO BE LEAKING. UPON REMOVAL OF THE DRAIN P/N L83A13-628, THE INSTALLATION O-RING P/N M25988/1-021 WAS FOUND TO BE MISSING. THE LT WING TANK FUEL DRAIN WAS REMOVED FOR INSPECTION AS A PRECAUTION AND IT HAD THE O-RING INSTALSDR DXTA2018011500479Flap System · malfunctionedON DEPARTURE AND UPON RETRACTING THE FLAPS FROM FLAPS 1, RECEIVED A FLAPS FAIL CAS MESSAGE. THE FLAP INDICATOR WAS SHOWING AN X. QRH WAS PERFORMED. MOVING THE FLAP HANDLE HAD NO EFFECT. THE FLAP HANDLE WAS PLACED ON THE ZERO POSITION. DURING POST FLIGHT,
Back to Embraer Executive EMB-505