Eurocopter BK117-B2
Service difficulty reports · 435
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'BK117B2' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'BK117B2' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR BAQA090303Indicator · oscillatesARTIFICIAL HORIZON OSCILLATING YAW MOTION. REPLACED WITH SERVICEABLE UNIT.SDR BAQA090564Power Supply · malfunctionedZERO VOLTAGE COMING FROM 500 VOLTS PLUG. REPLACED WITH SERVICEABLE UNIT.SDR AUS20031233Blade · cracked(AUS) MAIN ROTOR BLADE CRACKED IN BLADE THIMBLE RADIUS AREA. FOUND DURING REMOVAL AND INSPECTION IAW KHI KSB-117-168.SDR AUS20031232Blade · cracked(AUS) MAIN ROTOR BLADE CRACKED IN BLADE THIMBLE RADIUS AREA. FOUND DURING REMOVAL AND INSPECTION IAW KHI KSB-117-168.SDR BAQA089010Gyro · malfunctionedINTERNAL LIGHTING INOPERATIVE. REPLACED WITH SERVICEABLE UNIT.SDR BAQA089045Indicator · malfunctionedREQUEST WARRANTY REPAIR. NR 1 N2 NEEDLE READS 2 PERCENT WHEN POWERED UP. NR 1 N2 NEEDLES READS 100 PERCENT, NR 2 N2 NEEDLES READS 99 PERCENT, AND NR READS 98 PERCENT AT FULL "FLY" RPM. PART ONLY LASTED 29.5 HOURS FROM THE LAST REPAIR. UNIT SENT OUT TO AEC FSDR BAQA088839Starter Gen · failedSTARTER GENERATOR FAILED. WOULD NOT TEST. REPLACED WITH SERVICEABLE UNIT. 9/4/03SDR 2003F00594Transducer · failedAPPROXIMATELY 305 MINUTES AFTER TAKEOFF, NR 2 TORQUE INDICATOR FAILED. ALL OTHER INSTRUMENTS WERE INDICATING NORMAL. REMOVED AND REPLACED PRESSURE TRANSDUCER. OPERATION CHECKS GOOD. (M)SDR 2003F00593Computer · inoperativePILOT REPORTED YAW CSAS FAILURE EN ROUTE TO HOSPITAL. NO COCKPIT INDICATIONS, ONLY INTERMITTENT UNCOMMANDED TAIL ROTOR INPUTS. AIRCRAFT RETURNED TO BASE FOR MX. AFTER TROUBLESHOOTING YAW SYSTEM, FOUND YAW COMPUTER TO BE INOPERATIVE. REMOVED AND REPLACED COSDR BAQA087928Control Panel · malfunctionedANNUNCIATOR PANEL INOPERATIVE. MASTER CAUTION WILL NOT EXTINGUISH UNLESS ALL 5 SEGMENTS ARE OUT. REPLACED WITH SERVICEABLE UNIT.SDR A1U2003F00002Chip Detector · contaminatedWHILE IN CRUISE FLIGHT, ENGINE NR 2 CHIP LIGHT ILLUMINATED, CHIP PLUSE SYSTEM WAS ACTIVATED THREE TIMES, EACH TIME THE LIGHT REILLUMINATED. INFORMED COMPANY DISPATCH OF SITUATION, THEY INFORMED MAINTENANCE. INITIATED PRECAUTIONARY LANDING PROCEDURES, CONTACTSDR BAQA086455Actuator · malfunctionedCAUSING SEVERE KICKING EVEN WITH YAW-CSAS DISENGAGED. SEALS LEAKING. REPLACED WITH SERVICEABLE UNIT.SDR AUS20030478Bearing · failed(AUS) LONGITUDINAL CONTROL SYSTEM ROD END BEARING TEFLON LINER FAULTY.SDR 2003F00224Window · separatedDURING CLIMB OUT, GOING THROUGH 600 FT, THE SLIDING WINDOW OF THE PILOT'S DOOR WINDOW DEPARTED THE AIRCRAFT. MAINTENANCE FOUND THE TRACK WHERE THE SLIDING WINDOW RIDES WAS DEBONDED FROM THE WINDOW. TRACK WAS REGLUED WITH EPOXY RESIN AND SECURED TO THE WINDOWSDR AUS20030444Manifold · faulty(AUS) NR 1 ENGINE REPLACEMENT FUEL MANIFOLD FAULTY. SUSPECT FLOW DIVIDER PROBLEM. MANIFOLD WAS FITTED TO REPLACE A CRACKED AND LEAKING MANIFOLD. SEE MDR 03/0443 FOR DEFECT.SDR AUS20030443Manifold · cracked(AUS) NR 1 ENGINE FUEL MANIFOLD LEAKING DUE TO CRACKING AT THE SOLID TUBE/RAIL LOCATED AT THE 4 O'CLOCK POSITION.SDR BAQA085196Gyro · inoperativeSKEWED 8 DEGREES TO THE LT WHEN SPOOLED UP. REPLACED WITH SERVICEABLE UNIT.SDR BAQA084830Indicator · fluctuatesTRIPLE TACH NR NEEDLE INTERMITTENTLY FLUCTUATES 20-30 PERCENT. REPLACED WITH SERVICEABLE UNIT.SDR CA030125001Blade · cracked(CAN) CHORDWISE CRACK FOUND ON RED MAIN ROTOR BLADE 100MM CUFF S/N 806, 80MM OUTBOARD OF BLADE FITTING. MAIN ROTOR BLADES (4) REPLACED, MANUFACTURER NOTIFIED.SDR BAQA082148Indicator · frozenTURN AND BANK INDICATOR NEEDLE FROZEN. REPLACED WITH SERVICEABLE UNIT.SDR BAQA081599Pump · inoperativeBOOST PUMP INOPERATIVE. REPLACED WITH SERVICEABLE UNIT.SDR CA021209009Bellcrank · grooved(CAN) TAIL ROTOR BELLCRANK FOUND WITH 11.45MM LONG BY 2MM WIDE, DEPTH STILL UNKNOWN RADIAL GROOVE WORN 2MM ADJACENT TO SPHERICAL BEARING HOUSING. DAMAGE CAUSED BY EARS OF TAIL ROTOR BELLOWS RUBBING AGAINST BELLCRANK ASSY.SDR CA021206001Bushing · worn(CAN) PRIMARY BUSHING WAS NOT FULLY INSTALLED INTO THE BLADE. THE UPPER PORTION WAS PROTRUDING. THIS PROTRUSION CAUSED WEAR ON THE LOWER SURFACE OF THE UPPER GRIP OF THE MAIN ROTOR HEAD INNER SLEEVE. THE WEAR WAS BEYOND SERVICEABLE LIMITS. THE MAIN ROTOR HEAD SDR AUS20021361Fitting · cracked(AUS) TAIL ROTOR GEARBOX FITTING CRACKED.SDR CA021021005Lens · broken(CAN) AFTER A/C SHUTDOWN, PILOT NOTICED ANTI-COLLISION BEACON LENS BROKEN, WITH TOP PORTION MISSING BUT BASE STILL INTACT. MAINTENANCE NOTIFIED AND INSPECTION OF TAIL ROTOR SYSTEM AND BLADES CARRIED OUT, NO DAMAGE FOUND. LENS DAMAGE APPARENTLY CAUSED BY OVERTISDR CA021007010Rod End · worn(CAN) PILOT NOTICED UNUSUAL VERTICAL VIBRATION IN HOVER AND LANDED IMMEDIATELY. MAINTENANCE DICOVERED BLUEMAIN ROTOR ROTATING CONTROL ROD LOWER ROD END BEARING HAD EXCESSIVE PLAY. THIS WASDUE TO 1/3TH OF THE SPHERICAL BEARING OUTER RACE WORN AWAY. SPHERICALSDR CA020816006Stop Pin · missing(CAN) PILOT DOING DAILY INSPECTION NOTICED SX5 TURNED BEYOND 90 DEGREE LEFT POSITION WHERE NORMAL STOP OCCURS. FURTHER VISUAL INSPECTION REVEALED ROLL PIN MISSING THEREFORE NOTHING TO MECHANICALLY STOP THE 360 DEGREE ROTATION OF SEARCHLIGHT. PIN REPLACED,LIGHTSDR CA020815006Engine · making metal(CAN) DURING DEPARTURE, NR 1 ENGINE CHIP INDICATION LIGHT ILLUMINATED, PILOT PULSED SYSTEM, LIGHT EXTINGUISHED. A/C LANDED LOAD PASSENGERS AND CONTINUE MISSION, DURING SECOND DEPARTURE NR 1 ENGINE CHIP INDICATION LIGHT ILLUMINATED, PILOT PULSED SYSTEM AND LSDR CA020803001Piston · failed(CAN) AT SHUT DOWN OF THE HELICOPTER THE PILOT REPORTED A SQUEALING NOISE FROM THE AREA OF THE TRANSMISSION. ON INVESTIGATION IT WAS FOUND THAT THE ROTOR DISK HAD DISCOLORED AND HAD WARPED FORWARD. FURTHER INVESTIGATION REVEALED THAT THE REAR PAD PISTON HAD SDR AUS20020635Cargo Hook · broken(AUS) CARGO HOOK KEEPER ASSEMBLY ARM (1OFF) BROKEN AND THE OTHER ARMBENT. THE LOAD BEAM WAS ALSO BENT. THE LOAD WAS UNINTENTIONALLY RELEASED.SDR R7MR35511Pickup · intermittentELECTROMAGNETIC SPEED PICKUP OPERATES INTERMITTENTLY. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR35087Battery · inoperativeLEAD ACID BATTERY-UNIT INOPERATIVE. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR 2002F00299Wire Harness · shortedELECTRICAL FORWARD CABLE INTERNAL SHORT. REPLACED WITH NEW UNIT CORRECTED PROBLEM. CLAIM FROM WARRANTY REPAIR TO EXCHANGE. (M)SDR 2002F00298Wire Harness · shortedELECTRICAL FORWARD CABLE INTERNAL SHORT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. CLAIM CHANGED FROM WARRANTY REPAIR TO EXCHANGE. (M)SDR R7MR34351Harness · shortedFORWARD ELECTRICAL CABLE, INTERNAL SHORT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR34353Harness · shortedFORWARD ELECTRICAL CABLE, INTERNAL SHORT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR AUS20011094Fire Detector · faulty(AUS) NO2 ENGINE FIRE DETECTOR ACTIVATION. FIRE BOTTLE OPERATED.INVESTIGATION FOUND THAT THE AIRCRAFT WAS IN AN UNUSUAL NOSE HIGH TURN AT THE TIME WHICH HAS IN THE PAST CAUSED THE FIRE DETECTOR TO ACTIVATE FOR SHORT PERIODS.SDR 2001F00693Battery · defectiveLEAD ACID BATTERY WILL NOT HOLD CHARGE. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (M)SDR 2001FA0000312Modulator · looseWHILE TROUBLESHOOTING ENGINE FOR SURGING PROBLEM. AIRFLOW MODULATOR WAS CHANGED. FILTER ELBOW HAS TO BE TRANSFERED TO NEW MODULATOR. FOUND FILTER SCREEN TO BE LOOSE INSIDE ELBOW AT THIS TIME. BROKEN FILTER HAD NO EFFECT ON THIS SURGING PROBLEM. MUST INSPESDR 2002F00297Wire Harness · shortedELECTRICAL FORWARD CABLE INTERNAL SHORT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. THIS CLAIM CHANGED FROM WARRANTY REPAIR TO EXCHANGE. (M)SDR R7MR34354Harness · shortedFORWARD ELECTRICAL CABLE, INTERNAL SHORT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR TI1R001481Symbol Generator · malfunctionedSIGNAL GENERATOR, INTERMITTENTLY CAUSES EFIS TO GO TO (TEST IN PROGRESS)-THEN ERROR OF SIGNAL ON EFIS T, REMOVED AND REPLACED.SDR R7MR33477Bellows · tornBELLOWS IS TORN AROUND CLAMP AND FOLD AREAS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR TI1R001467Gyro · tumblesATTITUDE GYRO, TUMBLING, REMOVED AND REPLACED.SDR TI1R001428Light · inoperativeATTITUDE GYRO, INTERNAL LIGHTING, INOPERATIVE. REMOVED AND REPLACED.SDR TI1R001402Indicator · erraticTRIPLE TACH - NR 1 NEEDLE BOUNCES BETWEEN 30 AND 60 PERCENT AT ENGINE IDLE- ROTOR NEEDLE GIVING WRONG INDICATION. REMOVED AND REPLACED.SDR R7MR33309Wire · shortedSPECIAL PURPOSE ELECT(AFT) CABLE, INTERNAL SHORT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR TI1R001371Altimeter · inoperativeENCO ALTIMETER, CODE OFF, FLAG WILL NOT PULL. REMOVED AND REPLACED.SDR AU000570Governor · failed(AUS) RIGHT ENGINE POWER TURBINE GOVERNOR INTERNAL FAILURE. GOVERNOR DRIVE SPLINE SHEARED WITH CORRESPONDING ENGINE OVERSPEED. (X)SDR 20000413SH039Encoder · malfunctionedALTIMETER OUT OF CALIBRATION. DOES NOT AGREE WITH COPILOT''S ALTIMETER OR TEST BOX. OFF AT 3,000 FEET. REMOVED AND REPLACED. (X)
Back to Eurocopter BK117-B2