Helibras AS 350 B3
Service difficulty reports · 1,007
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'AS350B3' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'AS350B3' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QMLA09032009011Unknown · odorAFTER REFUELING, THE ACFT TOOK OFF AND STARTED TO CLIMB OUT, THE MED CREW THOUGHT THAT THEY SMELLED A STRONGER THAN NORMAL ODOR OF FUEL. PILOT SAID THE COCKPIT TO SMELL NORMAL. PILOT RETURNED TO THE HOSPITAL. POST FLIGHT REVILED NO DEFECTS OR CAUSE OF THE FSDR RMXA029H325622609Fitting · corrodedUPON REMOVAL OF THE AIRFRAME VERTICAL FIN ASSY, THE UPPER VERTICAL FIN FWD ATTACH STEEL FITTING SEPARATED FROM THE UPPER VERTICAL FIN. INSP REVEALED THAT ALL RIVETS ATTACHING THE FITTING TO THE FIN WERE CORRODED BEYOND RETENTION. ALSO FOUND THE SHIN OF THE FINSDR CA090225002Hose · leaking(CAN) HYDRAULIC HOSE REPLACED 89.0 HRS PRIOR TO OTHER HOSE WITH 650.0 HRS. BOTH HOSE ASSEMBLIES HAD PIN HOLE LEAKS.SDR CA090217002Angle · loose(CAN) WHILE PERFORMING DAILY INSP ON ACFT NOTICED THE RIVETS THAT ATTACH THE T/E ANGLE TO UPPER VERTICAL STABILIZER (PN 350A14-0020-1902) WERE "SMOKING" AND ANGLE FELT LOOSE.SDR CA090223013Friction Ring · failedPRIOR TO INSTALLING STARTER GEN SB 80.00.07 PARA 2B2B AND 2B3 WERE APPLIED. THE STARTER WAS THEN INSTALLED AS PER MM AND A GROUND RUN WAS DONE. DURING THE GROUND RUN NO VIBRATION WAS NOTED ON THE STARTER, VOLTAGE AND AMPERAGE WAS NORMAL. I NOTICED A BURNINGSDR QMLA2009010109001Wire · chafedWITHIN (1) MINUTE AFTER TAKEOFF ON A LOCAL HOSPITAL TRANSFER FLIGHT THE PILOT AND AIRCREW SMELLED BURNING ELECTRICAL EQUIPMENT. THE INSTRUMENT PANEL LIGHTS WENT OUT AT THE SAME TIME. NO FIRE WAS SEEN AND NO VISIBLE SMOKE WAS PRESENT. PILOT TURNED THE ACFT FSDR CA081212012Magnetic Seal · leaking(CAN) MAG SEAL LEAK AT INPUT SEAL OF TGB.SDR 2008FA0000729Unknown · odorSHORTLY AFTER TAKEOFF, PERSONNEL ONBOARD REPORTED A BURNING ODOR TO THE PILOT. ABORTED FLT AND RETURNED TO HELIPAD TO INVESTIGATE. MECH PERFORMED AN INSPECTION OF THE AIRFRAME, ENGINE, WIRING, HOSES AND THE BELTS OF ALL COMPONENTS. NO DEFECTS OR THE SOURCE OFSDR HXS2008F00001Bellcrank · crackedON THE BOTTOM SIDE OF THE FOOT PEDAL CONTROLS, ON BOTH THE RT AND LT SIDES, THERE IS A BRACKET THAT IS PART OF THE FOOT PEDAL BELLCRANK PN 350A27-1170-00, TO GO OUT OF ALIGNMENT AND CONTACT THE SURROUNDING SUPPORT STRUCTURE THUS CAUSING A .2500 INCH GROOVE INTSDR HXS2008F00000Bracket · crackedON THE BOTTOM SIDE OF THE FOOT PEDAL CONTROLS, ON BOTH THE RT AND LT SIDES, THERE IS A BRACKET THAT IS PART OF THE FOOT PEDAL BELLCRANK ASSY, THE LT BRACKET PN 350A21136324, HAS A CRACK IN IT. THE RT BRACKET, SAME PN, CRACKED ALL THE WAY THROUGH WHICH ALLOWED SDR QML2008F00014Motor · shortedDEPARTED ON A ROUTINE EMS MISSION, SHORTLY AFTER DEPARTURE, PILOT ABORTED FLT AND RETURNED TO HELIPAD. INFORMED MAINTENANCE OF A STRONG ELECTRICAL ODOR IN ACFT CABIN. SOURCE OF ODOR DETERMINED TO BE ELECTRIC MOTOR IN AIR CONDITIONING SYS CONDENSER BLOWER ASSY SDR QML2008F00007Starter Gen · disintegratedGENERATOR LIGHT ILLUMINATED JUST AFTER TAKE OFF FOR AN NVG TRAINING FLIGHT, WITH AN ELECTRICAL BURNING/OZONE ODOR IN THE COCKPIT. THE PILOT RETURNED TO BASE AND LANDED WITHOUT FURTHER INCIDENT. ELECTRICAL ODOR DISPERSED BEFORE LANDING. UPON INSPECTION OF THSDR CA080710003Switch · failed(CAN) FUEL PUMP WOULD NOT TURN ONSDR 2008FA0000483Belt · brokenGROUND CREW NOTICED THE SMELL OF FUEL AND VAPOR COMING FROM AIRCRAFT AFTER LIFTING FROM SCENE. PIC NOTIFIED OF THE CIRCUMSTANCES. PIC MADE A PRECAUTIONARY LANDING WITH PATIENT ON BOARD. PIC DETERMINED THAT THE VAPOR WAS COMING FROM THE AIR CONDITIONER, AND NSDR 2008FA0000481Connector · contaminatedDURING CRUISE FLIGHT, THE ENGINE FIRE LIGHT ILLUMINATED. DURING THE DESCENT FOR A PRECAUTIONARY LANDING, THERE WAS NO SMOKE TRAILING THE AC AND THE ENGINE FIRE LIGHT EXTINGUISHED AND ILLUMINATED SEVERAL TIMES. AFTER SECURING THE AC UPON LANDING, THE PILOT INSDR 399505152008Garlock Seal · leakingAC WAS REQUESTED TO RESPOND TO THE AIRPORT FOR A SCENE RENDEZVOUS WITH THE AMBULANCE. AFTER DEPARTURE FROM HOSPITAL, THE MEDICAL CREW NOTICED A FUEL ODOR. THE FLIGHT WAS ABORTED AND AC LANDED AT MEDICAL CENTER WITH ALL AIRCRAFT INDICATIONS NORMAL. ON FINAL APPSDR CA080407006Pump · malfunctioned(CAN) DURING NORMAL FLIGHT DURING A BIRD TOWING OPERATION THE PILOT RECEIVED A BING INDICATING A FAILURE. AIRSPEED 60KTS, 1000 FT AGL, 170 FT LINE WITH BIRD, 45 MINUTES INTO FIRST FLIGHT OF THE DAY: " BING " HEARD IN HEADSET, HYD WARNING LIGHT OBSERVED, NOTICSDR CA080226003Annunciator · malfunctioned(CAN) ON A ROUTINE CHECK FOLLOWING START, THE ANNUNCIATOR LIGHT FOR GOV FAILURE (RED) FAILED TO ILLUMINATE WHEN THE ENGINE GOV SWITCH WAS MOVED FROM AUTO TO MANUAL. OTHER FUNCTIONS ASSOCIATED WITH MOVING TO MANUAL (SOLENOID, VEMD FAILURE CODES) OPERATED NORMALSDR CA080218006Thermocouple · grooved(CAN) AFTER LESS THAN 500 HRS THERMOCOUPLES FOUND WITH A GROOVE WORN INTO TIPS. THIS IS THE SECOND TIME THIS DEFECT HAS BEEN FOUND. (TC NR 20080218006)SDR CA080218005Thermocouple · grooved(CAN) AFTER LESS THAN 500 HRS THERMOCOUPLES FOUND WITH A GROOVE WORN INTO TIPS. THIS IS THE SECOND TIME THIS DEFECT HAS BEEN FOUND. (TC NR 20080218005)SDR CA080218002Heat Shield · chafed(CAN) WHILE REPLACING THE MO5, SEVERAL HOLES WERE NOTICED. THESE HOLES WERE DUE TO RUBBING AND WERE ONLY THROUGH THE OUTER LAYER OF THE HEAT SHIELD. (TC NR 20080218002)SDR CA080314021Engine · making metalON THE FIRST GROUND RUN OF THE DAY DURING GROUND WARM UP, A NOISE WAS EMITTED FROM THE ENGINE AND IMMEDIATLEY AFTER NOISE WAS HEARD THE ENGINE CHIP LIGHT ILLUMINATED. PILOT SHUT ENGINE DOWN. METAL PARTICLES WERE FOUND ON MOS CHIP PLUG AND SOME ON THE ELECTRISDR CA080208003Reduction Gb · making metal(CAN) DURING DAILY INSPECTION SMALL FLAKES WERE FOUND ON THE NON-MAGNETIC CHIP PLUG ON (MODULE) MO 5. ENGINE OIL WAS CHANGED OIL FILTER WAS CHANGED ALL MAG PLUGS INSPECTED AND CLEANED. A/C FLEW FOR 11.1 HRS AND SMALL FLAKES WERE FOUND ON SAME PLUG. A/C WAS GRSDR CA080115012Combust Chamber · fod(CAN) DURING A 600 HR ENGINE INSPECTION, A BORESCOPE INSPECTION WAS CONDUCTED IN THE COMBUSTION CHAMBER AREA( INTERNAL) AN OBJECT WAS DISCOVERED HANGING OUT INTO THE FLAME PATH JUST UPSTREAM OF THE POWER TURBINE. THE OBJECT WAS PROTRUDING FROM AN INNER COOLINGSDR QMLA010108001Canister · fullAFTER DEPARTURE FROM BASE HOSPITAL AND ENROUTE TO SENDING HOSPITAL, PILOT NOTICED A PERSISTENT FUEL ODOR IN THE CABIN. THE PILOT THEN ABORTED THE MISSION AND RETURNED TO BASE MAINTENANCE HELIPAD. TROUBLESHOT THE PROBLEM. FOUND THE FUEL PURGE CANISTER FULL SDR CA071206008Module · damaged(CAN) IN A CRUISE FLIGHT OR CLIMB POWER, THE AC ENGINE WOULD SURGE. THE AC WAS REMOVED FROM SERVICE FOR INSP. A CLOSE INSPECTION OF THE COVER THAT IS LOCATED OVER THE COMPRESSOR IMPELLOR, REVEALED A HOLE APPX. 4-5MM IN DIAMETER. THE MODULE 3 WAS REMOVED AND RSDR 363011292007Hydromech Unit · leakingDURING PATIENT TRANSFER FLIGHT FROM OUTLYING HOSPITAL TO MAIN HOSPITAL, FUEL FUMES NOTED BY ALL CABIN OCCUPANTS. VENTS AND HEATER DUCTS MANIPULATED WITH NO DISCERNABLE EFFECT. SMELL OF FUEL FUMES INCREASED IN INTENSITY TO UNPLEASANT LEVELS UPON REDUCTION OF COSDR CA071123002Engine · malfunctioned(CAN) PILOT IN CRUISE FLIGHT, APPROX 2000 FEET, EXPERIENCED ENGINE PROBLEMS WITH ANNUNCIATOR INDICATIONS . PROCEEDED WITH SUCCESSFUL AUTOROTATION LANDING IN FIELD. REST IS UNDER INVESTIGATION (TC NR 20071123002)SDR 420611112007Fire Warning · false activationSECOND OCCURRENCE OF A FALSE ENGINE FIRE WARNING ON THIS AIRCRAFT IN THE LAST THREE DAYS. ONE FLIGHT OCCURRED BETWEEN THE TWO INCIDENTS. ARRIVED AT HOSPITAL TO PICK UP PATIENT TO TRANSPORT TO ANOTHER HOSPITAL. WHEN THE TWIST GRIP WAS PLACED IN THE IDLE POSITIOSDR 420611092007Warning Light · false activationPERFORMED AIRCRAFT STOPPING ENGINE ITEMS AS OUTLINED IN CHECK LIST. WHEN TWIST GRIP WAS PLACED IN THE IDLE POSITION, THE (ENG FIRE) WARNING LIGHT ON THE CWP CAME ON. CREW MEMBER OUTSIDE THE AIRCRAFT WAS ASKED IF SMOKE OR FLAMES WERE PRESENT. HE ADVISED THEY WESDR 363011032007Servo · failedAIRCRAFT WAS IN STRAIGHT AND LEVEL FLIGHT 10 MINUTES FROM T/O AT 7000 FT AGL. CYCLIC STICK JUMPED TO THE STOP AT THE 3 O’CLOCK POSITION. A/C ENTERED A RT BANK (APPROX. 10 DEGREES). IMMEDIATE RECOVERY WAS MADE. FELT CONTINUOUS FEEDBACK IN THE RT QUADRANT. SLOWSDR CA071022004Switch · malfunctioned(CAN) DURING GROUND RUN THE FORCED IDLE FUNCTION OF THE TWIST GRIP WAS BEING TESTED WHEN IT WAS OBSERVED TO NOT ACCELERATE BACK TO FLIGHT IDLE WHEN RETURNED TO THE (VOL) POSITION. THIS FUNCTION IS USED TO SIMULATE ENGINE FAILURE DURING PRACTICE AUTOROTATION. SSDR CA080123005Freq Adapter · blistered(CAN) ON INSP OF MAIN ROTOR HEAD AT THE END OF THE DAY ENGINEER FOUND BLISTERS ON THE SIDE OF ONE FREQUENCY ADAPTER. BLISTERS WHERE FOUND TO BE BEYOND LIMITS: REPLACED ALL (3) ADAPTERS. (TC NR 20080123005)SDR CA080123004Spherical Stop · cracked(CAN) PROTRUDING RUBBER FOUND COMING OUT, IN THE MIDDLE OF STOP. (TC NR 20080123004)SDR CA070917009Servo Control · leaking(CAN) M/R SERVO REMOVED FROM RT POSITION DUE TO LEAKAGE. (TC NR 20070917009)SDR HEEA117053Terminal · corrodedENGINE FIRE WARNING LIGHT ILLUMINATED DURING START UP. CLEANED CORROSION FROM LT REAR FIRE DETECTOR WIRE TERMINALS IAW MM 26-10-10, ASB072760 AND EMM TASK 26-11-00-050-001. PERFORMED OPERATIONAL CHECK WITH PILOT. CHECKS GOOD.SDR HEEA116984Connector · malfunctionedAMBER GOV LIGHT ILLUMINATED PRIOR TO LANDING, UPON SHUTDOWN, ENGINE WOULD NOT REDUCE RPM FROM FLIGHT POSITION WHEN START SELECT SWITCH SET TO IDLE. ENGINE WOULD NOT RESTART. CLEANED CONNECTIONS AND REPLACED GOVERNOR FUSE, REPLACED FUSE HOLDER AND REPLACED ESDR HEEA116829Engine · making metalDEPARTED, ENROUTE, THE AIRCRAFT ENGINE OIL PRESSURE LIGHT STARTED INTERMITTENTLY TO COME ON AND OFF THEN STAYED ON CONTINOUS WITH A GONG SOUND FOLLOWING. REFERRED TO AS350B3 EMERGENCY GUIDE, REDUCED POWER, AIRSPEED, AND AT 2148 ADVISED OPERATIONS OF THE SITUSDR 2007FA0000607Pulley · wornDURING DAILY INSPECTION DISCOVERED EXCESSIVE PLAY IN HYDRAULIC PUMP DRIVE PULLEY. HYDRAULIC PUMP DRIVE WAS THEN REMOVED FOR FURTHER INSPECTION. IT WAS DISCOVERED THAT THE DRIVE PULLEY SHAFT HAD WORN EXCESSIVELY WHERE THE DRIVE BEARING HAD BEEN SPINNING AROUND SDR 2007FA0000606Shaft · wornDURING DAILY INSPECTION DISCOVERED EXCESSIVE PLAY IN HYDRAULIC PUMP DRIVE PULLEY. HYDRAULIC PUMP DRIVE WAS THEN REMOVED FOR FURTHER INSPECTION. IT WAS DISCOVERED THAT THE DRIVE PULLEY SHAFT HAD WORN EXCESSIVELY WHERE THE DRIVE BEARING HAD BEEN SPINNING AROUND SDR 2007FA0000557Gearbox · unknownMGB CHIP LIGHT CAME ON IN FLIGHT. INSPECTED CHIP PLUGS IAW AEC MWC AND SPM. NO FURTHER ACTION REQUIRED.SDR 2007FA0000556Gearbox · unknownMGB CHIP LIGHT CAME ON IN FLIGHT. INSPECTED CHIP PLUGS IAW AEC MWC AND SPM. NO FURTHER ACTION REQUIRED.SDR FAA070628001Gearbox · making metalMGB CHIP LIGHT CAME ON IN FLIGHT. REMOVED CHIP PLUGS FROM THE MGB AND THE MAST FOUND PARTICALS ON THE MGB PLUG LESS THAN LIMITS CALLED OUT IN AEC AS350B3 SPM 20.08.01.601 NOTHING ON THE MAST PLUG.PERFORMED 10 MIN. HOVER AND RECHECKED CHIP PLUGS AS PER AEC AS35SDR AS350B3Gearbox · warning lightMGB CHIP LIGHT CAME ON IN FLIGHT. REMOVED CHIP PLUGS FROM THE MGB AND THE MAST FOUND PARTICLES ON THE MGB PLUG LESS THAN LIMITS CALLED OUT IN AEC AS350B3 SPM 20.08.01.601 NOTHING ON THE MAST PLUG. PERFORMED 10 MIN. HOVER AND RECHECKED CHIP PLUGS IAW AEC AS350SDR HEEA115978Indicator · failedRETURNED TO BASE, WHEN LANE 2 OF VEMD FAILED TO ILLUMINATE. REPLACEMENT OF VEMD CURED PROBLEM.SDR 2008FA0000147Cover · looseCOLLECTIVE MOUNTED HOIST EMERGENCY RELEASE (JETT) SWITCH COVER SECURITY. IF THE BASE OF THE COVER IS LOOSE AND TURNED 180 DEGREES, AS WAS THE CASE HERE, THE COVER OPENS FORWARD AND EXTENDS OFF OF THE END OF THE COLLECTIVE. IN THIS CONDITION WHEN THE COLLECTISDR HEEA115520Switch · inoperativeAMBER GOV CAUTION LIGHT IN FLIGHT, RED GOV CAUTION LIGHT AFTER SHUTDOWN. MAINTENANCE REPLACED START SWITCH.SDR 2007FA0000447Hose · burstHIGH PRESSURE AIR CONDITIONER HOSE BURST.SDR CA070425005Bearing · worn(CAN) DURING DI, HYDRAULIC PUMP PULLEY WAS NOTICED TO BE LOOSE LATERALLY WHEN MOVED SIDE TO SIDE. WHEN MAIN ROTOR WAS ROTATED HYDRAULIC PUMP PULLEY WAS FOUND NOT SPINNING SQUARE AND THE HYDRAULIC BELT WAS OFF SET FROM CENTER. HYDRAULIC PUMP PULLEY WAS REMOVED SDR 2007FA0000360Bracket · brokenDURING 100 HR INSPECTION, THE MECHANIC REACHED TO UNSCREW THE OIL FILTER AND THE BRACKET BROKE OFF IN HIS HAND. REPLACED UNIT, THE ENTIRE BREAK LOOKED FRESH EVEN WITH 10X MAGNIFICATION. IT IS A POT METAL BRACKET. (K)
Back to Helibras AS 350 B3