SDR R7MR324935236Liner · wornTEFLON LINERS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR325235214Power Supply · inoperativePOWER SUPPLY BOX INOPERATIVE. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR325135212Vent Line · crackedOIL TUBE AIR VENT CRACKED BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR HXS2002F00002Module · failedTORQUE INDICATION STARTED TO FLUCTUATE. REMOVED NR 1 MODULE WHICH HOUSES THE TORQUE TUBE AND INSTALLED A RENTAL. SENT NR 1 OUT FOR REPAIR. IT WAS DETERMINED THAT THE ROLL PINS IN TORQUE TUBE HAD SHEARED OFF.SDR 3144060302Compressor · defectiveA/C COMPRESSOR DEFECTIVE.SDR R7MR35467Switch · inoperativeNEUTRAL SWITCH INOPERATIVE WHEN HOT( DURING ENGINE OPERATION AND UP TO APPROX 20 MIN AFTER SHUTDOWN). REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR333635206Transponder · erraticTRANSPONDER INOPERATIVE, GIVES ERRATIC READINGS. REPLACED WITH NEW UNITS, CORRECTED PROBLEM.SDR CA020830014Motor · worn(CAN) ON SHUTDOWN PILOT HEARD FAN MAKING A DIFFERENT SOUND. ON INSPECTION OF FAN, IT WAS FOUND TO BE LOOSE. INDICATING WORN ARMATURE BEARING JOURNALS. AT THIS TIME A NEW DC MOTOR WAS INSTALLED. ON TEAR DOWN OF MOTOR IT WAS FOUND THAT IT NEEDED 2 NEW BEARING 4 SDR R7MR324935154Control Servo · leakingSERVO CONTROL LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT CORRECTED PROBLEM.SDR R7MR35074Display · malfunctionedVEMD (ASTAR AFTER 3018) DISPLAY PIXELS NOT READABLE IN LOWER SCREEN PORTION. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR35042Compressor Wheel · damagedGAS GENERATOR (MO3) , DAMAGE TO NR 1 TURBINE WHEEL DUE TO IGNITER CENTER ELECTRODE FAILURE (EJECTED THROUGH WHEEL). THIS IGNITER (9550168770 INSTALLED 07/11/2001) AND SL 2171/02/ARRIEL 1-66) INDICATES THAT THIS IGNITER WOULD PREVENT FUTURE FAILURES OF THISSDR R7MR35041Compressor Wheel · damagedAXIAL COMPRESSOR (MO2), DAMAGE TO NR 1 TURBINE WHEEL DUE TO IGNITER CENTER ELECTRODE FAILURE (EJECTED THROUGH WHEEL). THIS IGNITER (9550168770 INSTALLED 7/11/01) AND SL 2171/02/ARRIEL 1-66 INDICATES THAT THIS IGNITER WOULD PREVNET FUTURE FAILURES OF THIS TYPSDR R7M2002F00011Transceiver · inoperativeUHF/VHF/LOW/HI BAND TRANSCEIVER - UNIT INOPERATIVE. WILL NOT TRANSMIT ON 467.975 TONE 21 (136.5) WITH GENERATOR ON-LINE. REPLACED WITH LOANER UNIT PN 971083-1 CORRECTED PROBLEM.SDR R7MR325135247Bearing · wornTAIL ROTOR BEARING ELASTOMERICS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, FROM 1 EACH KIT CORRECTED PROBLEM. 4 HALF SHELLS EQUALS 1KIT.SDR R7M2002F00012Bleed Valve · failedBLEED VALVE INOPERATIVE. WILL NOT CLOSE. REPLACED WITH USED UNIT CORRECTED PROBLEM.SDR R7MR34754Starflex · debondedSTARFLEX - BUSHINGS DEBONDING. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR 2002FA0000531Starflex · debondedBUSHING ON END OF STARFLEX HAVE DEBONDED.SDR R7MR325235248Bearing · wornELASTOMERICS WORN BEYOND SERVICEABLE LIMITS. REPLACING WITH NEW UNIT FROM 1 EACH KIT CORRECTED PROBLEMS. 4 HALF SHELLS EQUALS 1 KIT.SDR R7M2002F00010Ecu · failedELECTRONIC CONTROL UNIT HAS A FAULT CODE. 135 FLT AMG GOV/LEFT MODULE FADEC. FAIL 2 0200 HEX. REPLACED WITH USED UNIT CORRECTED PROBLEM. NO LOG CARD IN ENGINE LOG BOOK. (OUR UNIT=40 HOURS. REPLACEMENT UNIT=1240 HOURS. DIFFERENCE 1200 HOURS. PLEASE CREDSDR R7M2002F00037Strut · wornEQUIPED COWLING STRUT - WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNITS, CORRECTED PROBLEMS.SDR CA020211015Starflex · debonded(CAN) AIRCRAFT TOTAL TIME 463 HOURS CONDUCTED A 500/A CALENDAR INSPECTION. BUSHING FOUND LOOSE ON STARFLEX ARM DURING INSPECTION AS PER WORK CARD 62.20.605 PARA. 5.3.SDR 2002F00314Pin · wornBLADE ASSEMBLY PIN WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (M)SDR R7MR34401Arm · separatedSTARFLEX ARM SEPARATION(RED BLADE). REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR35486Pressure Switch · inoperativeLOW FUEL PRESSURE SWITCH, UNIT INOPERATIVE. FULE LIGHT GOES OUT WITH BOOST PUMP ON. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7M2002F00038Pressure Switch · inoperativeLOW FUEL PRESSURE SWITCH, UNIT INOPERATIVE. FULE LIGHT GOES OUT WITH BOOST PUMP ON. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR CA020102001Blade · cracked(CAN) 35 MM CRACK IN BLADE SKIN ON TAIL ROTOR.SDR 2002F00288Hose · leakingHOSE LEAKING BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNITS CORRECTED PROBLEM. (M)SDR R7MR34293Bushing · debondedWORN BEYOND SERVICEABLE LIMITS. BUSHINGS DEBONDED FROM MFG. REPLACED WITH NEW UNITS, CORRECTED PROBLEM. (106LN) (K)SDR RM7R34387Liner · wornTEFLON LINERS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (N-106LN)(K)SDR R7MR34357Exciter · inoperativeIGNITION EXCITER HE 931, UNIT INOPERATIVE. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR34358Igniter · inoperativeIGNITER, UNIT INOPERATIVE. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR34356Exciter · frettedIGNITION EXCITER HE 931, FRETTING AND SEPARATION OF FLANKS. SEE SL2061/01/ARRIEL2/11. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR34241Motor · inoperativeFAN MOTOR, UNIT INOPERATIVE. MOTOR RUNS ROUGH. REPLACED WITH NEW UNIT CORRECTED PROBLEM.SDR R7MR34355Pressure Switch · failedLOW FUEL PRESSURE SWITCH, UNIT INOPERATIVE. FAILED TEST. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR34385Switch · inoperativeSWITCH INOPERATIVE. START SWITCH FAULT CODE UPON SHUTDOWN. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.(K)SDR R7MA34390Liner · wornTEFLON LINERS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT CORRECTED PROBLEM.SDR R7MA33696Blower · inoperativeUNIT INOPERATIVE. CAUSES FEEDBACK IN PILOT HEADSET. POSSIBLE SHIELDING PROBLEM. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MA33740Exciter · inoperativeUNIT INOPERATIVE WHEN HOT. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR 2002F00306Bearing · wornLAMINATED TAIL BEARING ELASTOMERICS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT FROM 1 KIT PART NUMBER 355A09-1036-01 CORRECTED PROBLEM. FOUR HALF SHELLS EQUALS 1 KIT. (M)SDR R7MR34362Power Supply · inoperativePOWER SUPPLY BOX, UNIT INOPERATIVE. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR R7MR34360Indicator · malfunctionedUNIT INOPERATIVE. SHOWS 20 FEET DOWN. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (106LN) (K)SDR 2001F00534Switch · failedSWITCH IS INOPERATIVE. REPLACED WITH NEW UNIT CORRECTED PROBLEM. (M)SDR 2001F00537Clock · inoperativeCLOCK IS INOPERATIVE. REPLACED WITH NEW UNIT CORRECTED PROBLEM. (M)SDR 2001F00702Pressure Switch · inoperativeLOW FUEL PRESSURE SWITCH IS INOPERATIVE. PIN 1 AND 2 FAILED CLOSING PSI. PIN 1 AND 3 NOTHING. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (M)SDR 2001F00503Indicator · sticksAIRSPEED INDICATOR STICKS AT 40 KNOTS. REPLACED WITH NEW UNIT CORRECTED PROBLEM. (M)SDR 2001F00696Transmitter · intermittentOIL PRESSURE TRANSMITTER OPERATES INTERMITTENTLY, NO VEMD INDICATIONS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM. (M)SDR R7MR34359Igniter · wornIGNITER, WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT, CORRECTED PROBLEM.SDR 2001F00514Bearing · wornELASTOMERICS WORN BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW UNIT FROM 1 EACH KIT P/N 355A09-1036-01 CORRECTED PROBLEM. FOUR HALF SHELLS EQUALS 1 KIT. (M)SDR 2002F00303Vent Line · crackedAIR VENT OIL TUBE CRACKED BEYOND SERVICEABLE LIMITS. REPLACED WITH NEW, UNIT CORRECTED PROBLEM. (M)SDR 2001F00525Compressor · seizedCOMPRESSOR SEIZED. REPLACED WITH NEW UNIT CORRECTED PROBLEM. (M)
Back to Helibras AS 350 B3