Mcdonnell Douglas DC-10-15
Service difficulty reports · 338
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC1015' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC1015' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA96245Smoke Detector · inoperativeAFT LAV-E SMOKE DETECTOR ON CONTINUOUSLY. REMOVED AND REPLACED SMOKE DETECTOR, OPS CHECKED NORMAL.SDR SCNA96229Power Supply · inoperativeFOUND FORWARD CABIN CEILING EMERGENCY LIGHT DOES NOT COME ON WHEN SYSTEM IS ARMED AND AIRCRAFT POWER IS REMOVED. REMOVED AND REPLACED THE FORWARD CABIN POWER SUPPLY IN ACCORDANCE WITH MM 33-51-01, SYSTEM OPS CHECKS NORMAL.SDR SCNA96228Skin · corrodedDURING A-CHECK INSPECTION, FIVE DIMPLES WERE NOTED IN LOCALIZED AREAS ON THE EXTERIOR OF THE FUSELAGE SKIN. THE DIMPLES ARE APPROXIMATELY 0.50 INCH IN DIAMETER AND ARE LOCATED AT STATIONS 1721, 1741, AND 1761 BETWEEN STRINGERS 45L AND 48L. INSTALLED A TIME LSDR SCNA96225Fire Wire · chaffedENGINE 3 LOOP-A LIGHT ILLUMINATED IN-FLIGHT WITHOUT FIRE WARNING. FOLLOWED COM PROCEDURE AND LOOP-B TESTED SATISFACTORY. LOOP-A LIGHT WENT OUT WHILE PERFORMING COM PROCEDURE. CONTINUED FLIGHT USING LOOP-B DETECTION FOUND CHAFED WIRE BY PYLON DETECTORS. PSDR SCNA96224Loop B Assy · faultENGINE 3 LOOP-A LIGHT ILLUMINATED IN-FLIGHT WITHOUT FIRE WARNING. FOLLOWED COM PROCEDURE AND LOOP-B TESTED SATISFACTORY. LOOP-A LIGHT WENT OUT WHILE PERFORMING COM PROCEDURE. CONTINUED FLIGHT USING LOOP-B DETECTION SYSTEM. REMOVED, INSPECTED, AND CLEANEDSDR SCNA96223Connector · dirtyENGINE 3 LOOP-A LIGHT ILLUMINATED IN-FLIGHT WITHOUT FIRE WARNING. FOLLOWED COM PROCEDURE AND LOOP-B TESTED SATISFACTORY. LOOP-A LIGHT WENT OUT WHILE PERFORMING COM PROCEDURE. CONTINUED FLIGHT USING LOOP-B DETECTION SYSTEM. REMOVED, INSPECTED, AND CLEANEDSDR SCNA96196Check Valve · inoperativeUNABLE TO PRESSURIZE CABIN, DUMPED APPROXIMATELY 30,000 POUNDS OF FUEL AND RETURNED TO LAS. FOUND CHECK VALVE (P/N 7012-505) TO BE INOP IN NUMBER 2 PACK AND A BLOWN AIR CONDITIONING DUCT (P/N 7009-605). REMOVED AND REPLACED BOTH PARTS IAW MM 21-30-0. DUCT LSDR SCNA96190Skin · corrodedDURING MAINTENANCE INSPECTION, CORROSION WAS FOUND IN THE FUSELAGE SKIN AT BS 890, NEAR STRINGER 44L. CUT OUT CORROSION, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH SRM 52-20-00.SDR SCNA96175Smoke Det · inoperativeFORWARD CARGO SMOKE DETECTOR WOULD NOT TEST. RELAMPED DETECTOR, OPS CHECK OK.SDR SCNA96154Smoke Detector · inoperativeTHE SMOKE DETECTOR IN THE LAV JUST AFT OF DOOR R1 WAS FOUND TO BE INOP. REMOVED AND REPLACED THE SMOKE DETECTOR, OPS CHECK OK.SDR SCNA96152Cylinder · inoperativeLANDING GEAR FAILED TO RETRACT. DUMPED APPROXIMATELY 28,000 LBS FUEL AND RETURNED TO BASE. REMOVED AND REPLACED BOGIE TRIM INTERLOCK CYLINDER ON LEFT MAIN LANDING GEAR IAW MM 32-31-05, SYSTEM OPS CHECK GOOD.SDR SCNA96150Coffee Maker · smokingAFT GALLEY LEFT HAND COFFEE MAKER STARTED SMOKING. PULLED CIRCUIT BREAKER AND SECURED AFT GALLEY BUS. REMOVED AND REPLACED THE LEFT HAND AFT COFFEE MAKER.SDR SCNA96053Frame · puncturedTHE FRAME WEB AT STATION 1841 WAS FOUND PUNCTURED AT APPROXIMATELY LONGERON 39L. REPAIRED FRAME IAW DC10 SRM 53-30-00, VOLUME I.SDR SCNA96046Indicator Bulb · failedTHE R4 DOOR SLIDE INDICATOR WOULD NOT ILLUMINATE WHEN PRESSED. RELAMPED SLIDE INDICATOR LIGHT, SLIDE TESTED GOOD.SDR SCNA96039Connector · faultyTHE SMOKE DETECTOR IN LAVATORY 'A' WAS FOUND TO BE INOPERATIVE. REPLACED ELECTRICAL CONNECTOR AT SMOKE DETECTOR. DETECTOR OPS CHECKED NORMAL.SDR SCNA96023Smoke Detector · failedLAVATORY B-SMOKE DETECTOR WILL NOT RESET. REMOVED AND REPLACED SMOKE DETECTOR AND PREFORMED SELF TEST, OPS CHECKED OK.SDR SCNA96013Wire · brokenTHE L-1 DOOR SLIDE PUSH TO TEST DOES NOT ILLUMINATE WHEN PRESSED. REPAIRED BROKEN WIRE AT BATTERY HOLDER AND SLIDE TESTED GOOD.SDR SCNA96010Battery · dischargedL-1 PASSENGER DOOR SLIDE LOW PRESSURE LIGHT DOES NOT PRESS TO TEST. REMOVED AND REPLACED BATTERIES IN L-1 DOOR SLIDE AND SLIDE TESTED GOOD.SDR SCNA96004Control Cable · out of adjAFTER TAKEOFF, LANDING GEAR HANDLE WOULD NOT MOVE TO THE UP POSITION. RETRACTED GEAR WITH HANDLE RELEASE BUTTON AND GEAR RETRACTED NORMALLY. ADJUSTED PUSH/PULL CABLE ROD END PER MM 32-21-01, ANTI-RETRACTION OPS CHECKED NORMAL ON GROUND.SDR SCNA95291Smoke Det Lamp · failedTHE NUMBER 3 CARGO SMOKE DETECTOR WOULD NOT TEST. RELAMPED DETECTOR AND UNIT OPS CHECKED GOOD.SDR SCNA95290Slide Batteries · faultyTHE R-2 DOOR EVACUATION SLIDE WOULD NOT TEST. REMOVED AND REPLACED BATTERIES FOR THE EVACUATION SLIDE AND SELF TESTED IAW MM 25-61-03, OPS CHECKED GOOD.SDR SCNA95283Skin · corrodedDURING A SCHEDULED INSPECTION, THE FUSELAGE SKIN WAS FOUND BULGING WITH A PULLED FASTENER AT FRAME STATION 1902 BETWEEN LONGERONS 45R AND 48R. THE CAUSE OF THE BULGING SKIN WAS ATTRIBUTED TO CORROSION BETWEEN THE FUSELAGE SKIN AND THE UNDERLYING TITANIUM TEARSDR SCNA95284Pan · crackedDURING A SCHEDULED INSPECTION, THE AFT CARGO DOOR WAS FOUND WITH A .75 INCH CRACK IN THE AFT DOOR PAN. THE CRACK EXTENDED FROM AN EXISTING FASTENER HOLE TO THE AFT EDGE OF THE PAN. THE DAMAGE WAS CUTOUT, A FILLER AND DOUBLER INSTALLED PER DC-10 SRM, VOL 1 CHSDR SCNA95254Skin · crackDURING A SCHEDULED MAINTENANCE CHECK, THE LOWER RIGHT WING SKIN AT XORS 981, STRINGER 32 WAS FOUND WITH IMPACT DAMAGE CONSISTING OF A 0.375 CRACK AND A SMOOTH DENT. THE CRACK AND DENT WERE REPAIRED IAW WITH SUN COUNTRY EO 57-5164-1.SDR SCNA95186Skin · corrodedTHE FUSELAGE SKIN WAS FOUND BULGING AND CRACKED WITH A PULLED FASTENER AT FRAME STATION 1761 BETWEEN LONGERON 47R AND 48R, JUST BELOW THE CENTER CARGO DOOR CUTOUT. THE BULGE WAS CAUSED BY CORROSION BETWEEN THE FUSELAGE SKIN AND THE UNDERLYING TITANIUM TEARSTRSDR SCNA95181Test Light Batt · dischargedTHE R-2 DOOR SLIDE INTEGRITY TEST LIGHT DID NOT ILLUMINATE WHEN PRESSED. REMOVED AND REPLACED TEST BATTERIES, AND SLIDE TESTED GOOD.SDR SCNA95173Eel Power Supply · faultyCOCKPIT EMERGENCY LIGHT SYSTEM FAILED SELF-TEST. REMOVED AND REPLACED THE LEFT OVERWING EMERGENCY POWER SUPPLY AND THE SYSTEM TESTED GOOD PER MM 33-51-01.SDR SCNA95172Eel Power Supply · failedCOCKPIT EMERGENCY LIGHT SYSTEM FAILED SELF-TEST. THE AFT CABIN EMERGENCY POWER SUPPLY WAS REPLACED AND THE SYSTEM TESTED GOOD.SDR SCNA95165Trim Brake Motor · crackedDURING TAXI OUT, ALL HYDRAULIC FLUID FROM SYSTEM 3 WAS LOST. AIRCRAFT RETURNED TO THE GATE. THE RIGHT HYDRAULIC HORIZONTAL STABILIZER TRIM BRAKE MOTOR CASING WAS FOUND CRACKED. REMOVED AND REPLACED TRIM BRAKE MOTOR AND ACCOMPLISHED LEAK CHECKS AND SERVICINGSDR SCNA95151Eel Power Supply · failedFOUND THE AFT CABIN EMERGENCY FLOOR LIGHTS INOPERATIVE. REMOVED AND REPLACED AFT CABIN POWER SUPPLY PER MM 33-51-01. LIGHTS TESTED GOOD.SDR SCNA95067Indicator · faultyTHE R-4 DOOR SLIDE WOULD NOT TEST, FOUND BROKEN WIRE AT TEST LIGHT SOCKET. REPAIRED WIRE AND SLIDE TESTED GOOD.SDR SCNA95066Smoke Detector · failedNUMBER 3 LAVATORY SMOKE DETECTOR FOUND TO BE INOPERATIVE. REPAIRED BROKEN WIRE LEADING TO SMOKE DETECTOR, SYSTEM CHECKED GOOD.SDR SCNA95054Smoke Detector · failedLAVATORY J SMOKE DETECTOR CONTINUOUSLY GOING OFF. REMOVED AND REPLACED SMOKE DETECTOR IN LAV J. OPS CHECKS GOOD IAW MM 26-29-00.SDR SCNA95052Eel Power Supply · malfunctionedOVERWING CABIN EMERGENCY LIGHT FAIL TEST. REPLACED OVERWING POWER SUPPLY. OPS CHECK GOOD.SDR SCNA95051Eel Power Supply · malfunctionedEMERGENCY LIGHTS HAVE FAULT INDICATOR LIGHT FOR OVERWING BATTERY PACK. REMOVED AND REPLACED POWER SUPPLY ABOVE DOOR L-3 AND TESTED GOOD PER MM 33-51-01.SDR SCNA95034Eel Power Supply · failedFORWARD CABIN EMERGENCY LIGHTS FAIL TEST. REPLACED FORWARD CABIN EMERGENCY LIGHTS POWER SUPPLY AND OPS CHECK GOOD.SDR SCNA95021Eel Power Pack · failedMSP - FORWARD CABIN EMERGENCY TRACK LIGHTING INOPERATIVE IN BOTH AISLES. REMOVED AND REPLACED FORWARD SECTION BATTERY POWER PACK, SPLICED BROKEN WIRES, EMERGENCY FLOOR TRACK LIGHTING OPS CHECKED GOOD. (X)SDR SCNA95015Hyd Line · leakingMSP - NR 2 HYDRAULIC SYSTEM PRESSURE LINE CHAFING WITH STANDBY RUDDER PRESSURE LINE CAUSING A LEAK BELOW NR 2 INLET DUCT. REPLACED BOTH LINES AND LEAK CHECKED GOOD. (X)
Back to Mcdonnell Douglas DC-10-15