Mcdonnell Douglas DC-9-82
Service difficulty reports · 23,866
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC982' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC982' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20150618003Stop Fitting · crackedFORWARD CARGO DOOR UPPER AFT DOOR STOP FITTING IS CRACKED. R & R FITTING IAW AARD 51-00-5-1 & DWG 5910141.SDR AALA20150616018Filter · cloggedEMER DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING APPROACH THE LT OIL STRAINER CLOGGING LIGHT ILLUMINATED. R & R NR 1 ENG FILTER & SERVICED OIL IAW AMM 72-00-02-101 STEP 4. PERFORMED OPERATIONAL & LEAK CHECK. SYS CHECKED NORMAL.SDR AALA20150616013Module · inoperativeFORWARD EGRESS LIGHT INOPERATIVE. REPLACED MODULE.SDR AALA20150616012Battery · dischargedCABIN ROWS 17 - 24 EMER LIGHTS WILL NOT TEST. REPLACED BATTERY POWER SUPPLY.SDR AALA20150616011Battery · dischargedFIRST CLASS CABIN ROWS 3 TO 7, EMER LIGHT WILL NOT TEST. REPLACED BATTERY POWER SUPPLY.SDR AALA20150616010Power Supply · inoperativeAFT GALLEY EMER LIGHT WILL NOT TEST. REPLACED POWER SUPPLY.SDR AALA20150614001Transceiver · defectiveAIR INTERRUPT, RETURNED, EMER WAS DECLARED. LANDING WAS UNEVENTFUL & ACFT WAS OVERWEIGHT. CREW REPORTED THAT DURING FLIGHT THE WEATHER RADAR WAS INOPERATIVE, ANTENNA FAILED. REPLACED THE WX RADAR TRANSCEIVER.SDR AALA20150612001Compressor Blade · damagedAIR INTERRUPT, RETURNED & EMER DECLARED. LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB, CREW REPORTS A COMPRESSOR STALL ON RT ENG FOLLOWED BY A REDUCTION IN EPR & INCREASE IN EGT. ACCOMPLISHED CARD 72-96-12 71-91-12 & BORESCOPE WITH A DETAILED VISUSDR AALA20150611009Pressure Switch · defectiveAIR INTERRUPT, DIVERTED, EMER DECLARED, LANDING UNEVENTFUL & ACFT WAS OVERWEIGHT. CREW REPORTED THE RT ENG OIL FILTER CLOG LIGHT ILLUMINATED. REPLACED THE RT ENG FILTER DIFFERENTIAL PRESS SWITCH IAW AMM 79-35-01.SDR AALA20150612003Battery Pack · dischargedEMERGENCY EVACUATION LIGHT BATTERY PACK B5-28 IS INOPERATIVE. R & R BATTERY PACK B5-28 IAW AMM 33-53-00. PERFORMED OPERATIONAL CHECK. SYS CHECKED NORMAL.SDR AALA20150612002Battery Pack · dischargedEMERGENCY EVACUATION LIGHT BATTERY PACK B5-27 IS INOPERATIVE. R & R BATTERY PACK B5-27 IAW AMM 33-53-00. PERFORMED OPERATIONAL CHECK. SYS CHECKED NORMAL.SDR AALA20150610003Skin · corrodedFUSELAGE SKIN BETWEEN STATIONS 230 & 257 IS CORRODED FROM LONGERONS 29L TO 30R. REPAIRED SKIN IAW SRM 53-04-03 FIG 4.SDR AALA20150608012Valve · leakingAIR INTERRUPT, EMER DECLARED. LANDING UNEVENTFUL & ACFT OVERWEIGHT. DURING CLIMB, TAIL COMPARTMENT HIGH TEMP INDICATION ILLUMINATED. INSPECTED TAIL COMPARTMENT & FOUND LT PRESS REGULATING VLV LEAKING. R & R VLV IAW AMM 21-31-01. ACCOMPLISHED CARD 36-95-14SDR AALA20150607008Target · faultyEMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING CLIMB OUT, GEAR DOOR OPEN LIGHT REMAINED ILLUMINATED AFTER GEAR RETRACTION. RECYCLING GEAR DID NOT EXTINGUISH LIGHT. R & R LT MLG DOOR TARGET & ADJUSTED IAW AMM 32-60-05. PERFORMED OPERASDR AALA20150606001Wire · brokenEMERGENCY PATH LIGHT AT SEAT 20D IS INOPERATIVE. FOUND BROKEN WIRE AT SEAT 20D. REPAIRED WIRE IAW AMM 20-10-03. SYS CHECKED NORMAL.SDR AALA20150608007Sensor · faultyAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT OVERWEIGHT. RETURNED, ACFT TAIL COMPARTMENT TEMP HIGH LIGHT. DURING TAKEOFF CREW NOTED A TAIL COMPARTMENT TEMP HIGH INDICATION. ACCOMPLISHED TAIL COMPARTMENT LEAK CHECK IAW MCM 36-95-14. R & R PRESS RSDR AALA20150604007Regulator Valve · leakingAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT OVERWEIGHT. RETURNED, ACFT TAIL COMPARTMENT TEMP HIGH LIGHT. DURING TAKEOFF CREW NOTED A TAIL COMPARTMENT TEMP HIGH INDICATION. ACCOMPLISHED TAIL COMPARTMENT LEAK CHECK IAW MCM 36-95-14. R & R PRESS RSDR AALA20150604008Accumulator · underservicedEMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. EXPERIENCING UNCOMMANDED RUDDER INPUTS DURING CLIMB. FOUND RUDDER ACCUMULATOR AT ZERO. SERVICED ACCUMULATOR IAW AMM 27-20-15. PERFORMED RUDDER THRU LIMITER SENSOR CHECK IAW AMM 27-20-06, YAW DAMSDR AALA20150603002Battery · dischargedFORWARD EMER POWER LIGHTS DIM WHEN POWERED BY BATTERY AB5-1. R & R BATTERY IN BATTERY PACK AB5-1. FWD EMER POWER LIGHTS OPERATIONALLY CHECKED NORMAL.SDR AALA20150603001Battery Pack · dischargedAFT OVERWING EMER EXIT LIGHTS INOPERATIVE. R & R BATTERY PACK. LIGHTS OPERATIONALLY CHECKED NORMAL.SDR AALA20150530004Pump · faultyEMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING APPROACH LT HYD LOW PRESS LIGHT ILLUMINATED WITH HYD QTY INDICATION HIGH. FOUND EXCESSIVE AIR IN BOTH HYD SYS, BLEED AIR. R & R NR 1 ENG HYD PUMP IAW AMM 29-10-05. SERVICED HYD SYS. PERFSDR 2CCA15052901918Actuator · out of adjustDURING POST MAINTENANCE VISIT ACCEPTANCE FLIGHT, DURING FLIGHT CONTROL CHECK IN EXCESS OF 250 KTS, FOUND LT RUDDER HAD NO EFFECT WHEN DEPRESSED FULLY - EITHER WITH POWER ON OR OFF. FULL RUDDER TRIM HAD NO EFFECT DEFLECTED LEFT. RT RUDDER CHECK AND TRIM OPERASDR AALA20150529014Control Unit · inoperativeEMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING DECENT ANTI- SKID LIGHT ILLUMINATED. R & R ANTI-SKID CONTROL IAW AMM 32-43-04. PERFORMED OPERATIONAL CHECK, SYS CHECKED NORMAL.SDR 2CCA2015060100066Piston · out of adjustDURING POST MAINTENANCE VISIT ACCEPTANCE FLIGHT, DURING FLIGHT CONTROL CHECK IN EXCESS OF 250 KTS, FOUND LT RUDDER HAD NO EFFECT WHEN DEPRESSED FULLY - EITHER WITH POWER ON OR OFF. FULL RUDDER TRIM HAD NO EFFECT DEFLECTED LEFT. RIGHT RUDDER CHECK AND TRIM OSDR AALA20150525001Switch · faultyEMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING DESCENT, CREW NOTED A PRESSURIZATION FLOW LIGHT INDICATION, LT & RT PACK FLOWS AT 0. R & R LT & RT PACK DIFFERENTIAL SWITCHES IAW AMM 21-31-09. SYS CHECKED NORMAL.SDR AALA20150520020Switch · faultyABORTED TAKEOFF AT 90 KNOTS DUE TO RT THRUST REVERSER UNLOCK LIGHT ILLUMINATED. ACFT RETURNED SAFELY TO GATE WITH NO FURTHER INCIDENT. ACCOMPLISHED HIGH ENERGY STOP INSPECTION WITH NO DEFECTS NOTED. REPLACED UPPER & LOWER THRUST REVERSER SWITCH. PERFORMED SDR AALA20150521012Sensor · faultyAIR INTERRUPT, EMER NOT DECLARED. DURING CLIMB, TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. ACCOMPLISHED WC 36-95-14 & FOUND RIGHT TAIL COMPARTMENT OVERHEAT SENSOR DUCT CHECK VLV STUCK CLOSED. R & R CHECK VLV ASSEMBLY & RT & LT TAIL COMPARTMENT OVESDR AALA20150521011Sensor · faultyAIR INTERRUPT, EMER NOT DECLARED. DURING CLIMB, TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. ACCOMPLISHED WC 36-95-14 & FOUND RT TAIL COMPARTMENT OVERHEAT SENSOR DUCT CHECK VLV STUCK CLOSED. R & R CHECK VLV ASSEMBLY & RT & LT TAIL COMPARTMENT OVERHESDR AALA20150520001Check Valve · stuckAIR INTERRUPT, EMER NOT DECLARED. DURING CLIMB, TAIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. ACCOMPLISHED WC 36-95-14 & FOUND RT TAIL COMPARTMENT OVERHEAT SENSOR DUCT CHECK VLV STUCK CLOSED. R & R CHECK VLV ASSEMBLY & RT & LT TAIL COMPARTMENT OVERHESDR AALA20150518009Seal · leakingAIR INTERRUPT, EMER DECLARED, LANDING UNEVENTFUL & ACFT OVERWEIGHT. DURING CLIMB THE AIL COMPARTMENT TEMPERATURE HIGH LIGHT ILLUMINATED. ACCOMPLISHED TAIL COMPARTMENT LEAK CHECK, WC 36-95-14. FOUND DUCT LEAKING BETWEEN RT AIR CYCLE MACHINE & RT HEAT EXCHANGSDR AALA20150518005Slide · unsecureAT GATE AS 1L DOOR WAS OPENED, UPON ARRIVAL, SLIDE FELL OUT OF HOUSING. REINSTALLED 1L DOOR SLIDE IAW MM 25-62-00.SDR AALA20150513011Computer · faultyAIR INTERRUPT, EMER NOT DECLARED. LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING TAKEOFF, RECEIVED MULTIPLE AURAL CONFIGURATION & FIRE WARNINGS, ENG FIRE WARNINGS, STABILIZER TRIM, CARGO FIRE. NO RED LIGHTS IN HANDLES OR OVERHEAD. R & R THE CENTRAL AURALSDR AALA20150513008Strap · corrodedCORROSION FOUND ON LONGERON STRAP AT L23L & FS 1257. R & R STRAP IAW AARD 51-00-05-1 DWG 5911423.SDR AALA20150511008Accumulator · faultyEMERGENCY DECLARED, LANDING UNEVENTFUL & ACFT NOT OVERWEIGHT. DURING DESCENT, RT THRUST REVERSER ACCUMULATOR LOW PRESS LIGHT ILLUMINATED. RAN QRH, LIGHT REMAINED ON. LIGHT EXTINGUISHED ON REVERSER EXTENSION. R & R RT THRUST REVERSER ACCUMULATOR IAW AMM 78-SDR AALA20150503007Element · dirtyLEFT OIL STRAINER, STRAINER CLOG LIGHT CAME ON DURING CRUISE & REMAINED ON. CHECKED LT ENGINE OIL STRAINER IAW AMM 72-00-02. REPLACED STRAINER TWICE & RAN ENG. MINOR COKE CONTAMINATION FOUND IN STRAINER WITH NO OTHER CONTAMINATION NOTED.SDR AALA20150503004Pump · leakingAT CRUISE, RT HYD QTY DECREASED TO 4 QTS WITH NR 2 ENG PUMP ON HIGH. HYD PRESS DROPPED TO ZERO. EMERGNECY DECLARED & LANDED WITHOUT INCIDENT, ON APPROACH, PRESSURIZED RT SYS USING AUXILIARY PUMP PRESS. FLAPS & SLATS EXTENDED NORMALLY. GEAR CAME DOWN BUT DOSDR AALA20150501013Cusp Web · corrodedRIGHT CUSP WEB CORRODED ON BOTTOM SURFACE BETWEEN BS 234 - 240. REPAIRED CUSP WEB IAW SRM 53-14-02 FIG 4.SDR AALA20150501006Stop Fitting · crackedFORWARD CARGO AFT LOWER DOOR STOP PAD CASTING IS CRACKED. R & R DOOR STOP PAD CASTING IAW AARD 51-00-05-01, DWG CDK2345 & 5910141.SDR AALA20150429013Pan · corrodedFORWARD CARGO DOOR PAN BETWEEN STRINGERS 27R & 28R ARE CORRODED FROM STATIONS 370 - 427. R & R DOOR PAN & SPLICE DOUBLERS IAW SRM 53-05-00-001, DWG DDK3295 & J060228.SDR AALA20150428008Skin · crackedFUSELAGE SKIN CRACKED AT STATION 1380 & LONGERON 14L. STOPPED DRILLED CRACK & INSTALLED DOUBLER IAW SRM 53-01-00-001.SDR AALA20150428009Oil Cooler · faultyRIGHT ENG CONSTANT SPEED DRIVE UNIT OUTLET TEMP INDICATED HIGH ABOVE RED LINE. CSD DISCONNECTED DUE TO OVER TEMP. ACFT DIVERTED WITH OVERWEIGHT LANDING. REPLACED ENG OIL COOLER WITH GOOD OPERATIONAL CHECKS IAW AMM 24-40-01 & AMM 24-10-03.SDR AALA20150428007Transformer · faultyRIGHT ENG CONSTANT SPEED DRIVE UNIT OUTLET TEMP INDICATED HIGH ABOVE RED LINE. CSD DISCONNECTED DUE TO OVER TEMP. ACFT DIVERTED WITH OVERWEIGHT LANDING. REPLACED ENG TRANSFORMER WITH GOOD OPERATIONAL CHECKS IAW AMM 24-40-01 & AMM 24-10-03.SDR AALA20150427012Generator · faultyRIGHT ENG CONSTANT SPEED DRIVE UNIT OUTLET TEMP INDICATED HIGH ABOVE RED LINE. CSD DISCONNECTED DUE TO OVER TEMP. ACFT DIVERTED WITH OVERWEIGHT LANDING. REPLACED ENG GEN WITH GOOD OPERATIONAL CHECKS IAW AMM 24-40-01 & AMM 24-10-03.SDR AALA20150426011Battery · out of positionLEFT & RIGHT OVERWING HATCH EMERGENCY LIGHTS INOPERATIVE DURING TEST. REPOSITIONED BATTERIES IN CHARGER. PERFORMED A SATISFACTORY OPERATIONAL CHECK IAW MCM CARD 0801.SDR AALA20150423007Door · malfunctionedNOSE GEAR DOORS DID NOT CLOSE PROPERLY AFTER TAKEOFF. NO EMERGENCY DECLARED & LANDING UNEVENTFUL. PERFORMED NOSE GEAR SWING TO VERIFY PROPER OPERATION IAW MCC 32-96-14 NOSE GEAR WITH NORMAL OPERATIONS.SDR AALA20150420015Light · inoperativeFORWARD DOOR EMER LIGHT ASSEMBLY INOPERATIVE. R & R LIGHT.SDR AALA20150418006Bulb · burned outEMERGENCY TAIL LIGHTS AT TAIL CONE & AFT FLIGHT ATTENDANT SEAT INOPERATIVE. REPLACED THE LAMPS FOR BOTH LIGHTS. OPERATIONALLY CHECKED GOOD.SDR AALA20150416008Skin · crackedCRACKS FOUND IN 3 FASTENER LOCATIONS ON FUSELAGE SKIN AT STATION 190 L22L. CUT OUT CRACKS, INSTALLED DOUBLER & FILLER IAW DWG SR09530219 VIEW C.SDR AALA20150418005Frame · crackedLEFT MLG CRACK IN FRAME 984 AT AFT OTBD CORNER OF WW NEXT TO FLAP BUS CABLE PULLEY BRACKET. SPLICED NEW CHANNEL SECTION IAW SRM 51-70-05 & DWG 5936373.SDR AALA20150413002Support Bracket · crackedMID CARGO DOOR CTR STOP PAD SUPPORT BRACKET CRACKED AT FWD SIDE OF CARGO DOOR. INSTALLED NEW SERVICEABLE FWD CTR STOP PAD SUPPORT BRACKET ON MID CARGO DOOR IAW AARD 51-00-05-1 & DWG 5910141.
Back to Mcdonnell Douglas DC-9-82