Mcdonnell Douglas DC-9-82

Service difficulty reports · 23,866

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC982'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR GTIA040334Accoustic Liner · damagedDTW - FOUND ACCOUSTIC LINE DAMAGE AT 12 O'CLOCK POSITION ON NR 1 ENGINE REAR FAN CASE SECTION. REMOVED AND REPLACED NR 1 ENGINE. (M)Apr 23, 2004 · N803NK · Doug DC982 · Engine Air Intake SystemSDR CALA0400410Web · crackedWEB CRACKED AT FWD LWR SIDE OF BAG BIN DOOR AT STA 636, LONG 27 LEFT. REMOVED AND REPLACED WEB PER ECRA 5310-04416.Apr 23, 2004 · N15841 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20040481Connector · looseMIA - EMERGENCY ESCAPE PATH LIGHT AT 7D INOPERATIVE. RESEATED CONNECTOR FOR EMERGENCY ESCAPE PATH LIGHT AT 7D. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 21, 2004 · N7538A · Doug DC982 · Light System WiringSDR GTIA040422Light · brokenEMERGENCY LIGHT AT L1 DOOR HOLDER IS BROKEN. REMOVED EMERGENCY LIGHT. INSTALLED SERVICEABLE EMERGENCY LIGHT.Apr 20, 2004 · N817NK · Doug DC982 · Emergency LightingSDR GTIA040421Light · broken5 EA EMERGENCY LIGHTS BROKEN IN AFT STAIRWELL. REMOVED BROKEN LIGHTS. INSTALL 5 EA NEW LIGHTS.Apr 20, 2004 · N817NK · Doug DC982 · Emergency LightingSDR CALA0400404Shear Tie · corrodedA/B/B SHEAR TIE CORRODED AT LONGERON 30 AND 28 RIGHT AT STATION 1193. FABRICATED AND INSTALLED SHEAR TIE REPAIR SPLICE BETWEEN LONG 30 AND 29 RIGHT PER SRM 53-03 FIG 3.Apr 20, 2004 · N15841 · Doug DC982 · Fuselage Main, Longeron/StringerSDR AALA20040476Battery Pack · dischargedDFW - EMERGENCY LIGHTS FROM FLIGHT ATTENDANTS FORWARD FLIGHT STATION TO OVERWING INOPERATIVE. REPLACED BATTERY PACK AT OVERWING FOR EMERGENCY LIGHTS FROM FLIGHT ATTENDANTS FORWARD FLIGHT STATION TO OVERWING. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 19, 2004 · N70504 · Doug DC982 · Emergency LightingSDR AALA20040475Battery Pack · dischargedDFW - AFT GALLEY EMERGENCY EXIT SIGN INOPERATIVE. REPLACED BATTERY PACK FOR AFT GALLEY EMERGENCY EXIT SIGN. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 19, 2004 · N555AN · Doug DC982 · Emergency LightingSDR AALA20040473Battery Pack · dischargedMIA - CEILING EMERGENCY EXIT LIGHTS IN FORWARD CABIN INOPERATIVE. REPLACED BATTERY PACK FOR CEILING EMERGENCY EXIT LIGHTS IN FORWARD CABIN. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 19, 2004 · N7548A · Doug DC982 · Emergency LightingSDR GTIA040328Slide · dislodgedFLL - FLT 433 - L2 DOOR SLIDE FELL OFF. INSTALLED SLIDE ASSEMBLY. (M)Apr 18, 2004 · N830NK · Doug DC982 · Escape SlideSDR ASAA0480280Power Supply · inoperativeSEA - DURING LINE CHECK, FOUND EMERGENCY OVERHEAD LIGHTS INOPERATIVE AT BOTH LEFT AND RIGHT OVERWING EXITS. REPLACED ASSOCIATED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)Apr 17, 2004 · N935AS · Doug DC982 · Emergency LightingSDR GTIA040330Retainer · brokenFLL - FOUND LEFT AFT SLIDE PACK COVER GIRT BAR RETAINING CLIP BROKEN. REMOVED AND REPLACED LEFT AFT SLIDEPACK COVER GIRT BAR RETAINING CLIP. OPS CHECK GOOOD. (M)Apr 17, 2004 · N803NK · Doug DC982 · Escape SlideSDR GTIA040333Connector · looseFOUND TAIL COMPARTMENT EMERGENCY EXIT IDENTIFIER IS NOT LIGHT ON TEST. SECURED CONNECTOR, OPS CHECK. (M)Apr 15, 2004 · N801NK · Doug DC982 · Electrical ConnectorsSDR ASMF200404012Pressure Switch · damagedAIRCRAFT RETURNED TO PLATFORM AS A CONSEQUENCE OF L OIL STRAINER CLOGGING LIGHT TURNED ON. THE ABNORMAL PROCEDURE WAS PERFORMED AND LEFT ENGINE WAS SHUTDOWN. THE FILTER AND SWITCH PRESSURE FILTER WERE REPLACED IAW 72-61-54 AND TEST CORRECT IAW MM 79-35-01.Apr 15, 2004 · N501AM · Doug DC982 · Engine Oil Indicating SystemSDR AALA20040465Pitot Line · leakingMIA - INFLIGHT T518 AT ROTATION AND LIFT OFF RUDDER RATIO LIGHT AND MACH INDICATOR LIGHT CAME ON. CAPTAIN AND FIRST OFFICER AIR SPEED NOT RELIABLE. CENTER GOOD. RETURNED TO MIA AND LANDED WITHOUT INCIDENT. COMPLETED RUDDER RATIO TEST/ADJUSTMENT AND NO FAULApr 15, 2004 · N7518A · Doug DC982 · Pitot/Static SystemSDR AALA20040461Battery Pack · dischargedDFW - EMERGENCY CEILING LIGHTS AT ROWS 18 THROUGH 20 INOPERATIVE. REPLACED CENTER BATTERY PACK AT ROW 20 FOR EMERGENCY CEILING LIGHTS ROWS 18 THROUGH 20. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 14, 2004 · N443AA · Doug DC982 · Emergency LightingSDR AALA20040457Battery Pack · inoperativeDFW - CEILING EMERGENCY LIGHTS AT ROWS 3 THROUGH 6 INOPERATIVE. REPLACED BATTERY PACK AT B5-100 FOR CEILING EMERGENCY LIGHTS AT ROWS 3 THROUGH 6. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 13, 2004 · N70401 · Doug DC982 · Emergency LightingSDR AALA20040455Battery Pack · inoperativeEMERGENCY OVERHEAD LIGHT AT ROW 29D INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY OVERHEAD LIGHT AT ROW 29. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 13, 2004 · N70504 · Doug DC982 · Emergency LightingSDR AALA20040450Slide · failedDFW - AFT LEFT HAND GALLEY DOOR IN ARMED POSITION AND WHEN DOOR OPENED BY CABIN SERVICES SLIDE PARTIALLY DEPLOYED AND CAME OUT OF SLIDE CASE BUT DID NOT INFLATE. REPLACED SLIDE FOR AFT LEFT HAND GALLEY DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 12, 2004 · N457AA · Doug DC982 · Escape SlideSDR GTIA040462Longeron · corrodedAFT PIT LONGERON 29L AT STA 1193 HAS CORROSION UNDER LIP AT HI LOC ATTACH POINT. REMOVED SECTION OF LONG 29L FROM FS 1127-1202. FABRICATED NEW LONGERON. FABRICATED NEW LONGERON SPLICE. INSTALLED STRINGER SPLICE. INSTALLED LONGERON SECTION.Apr 11, 2004 · N817NK · Doug DC982 · Fuselage Main, Longeron/StringerSDR GTIA040420Longeron · corrodedAFT PIT STA 1256 LONGERON 28R CORROSION UNDER LIP OF LONGERON. REMOVED DAMAGED LONGERON FROM STA 1255-1338. FABRICATED NEW LONGERON. INSTALLED LONGERON.Apr 11, 2004 · N817NK · Doug DC982 · Fuselage Main, Longeron/StringerSDR GTIA040419Longeron · corrodedAFT PIT LONGERON 30 STA 1236 HAS CORROSION UNDER LIP IN RADIUS. REMOVED DAMAGED LONGERON FROM STA 1236-1309. FABRICATED NEW LONGERON. INSTALLED LONGERON.Apr 11, 2004 · N817NK · Doug DC982 · Fuselage Main, Longeron/StringerSDR GTIA040276Light · looseORD - FLT 1504 - AFT GALLEY AISLE EXIT LIGHTING TRACK CAME UP. RE-ATTACHED AFT GALLEY LUMINESCENT EXIT STRIP. (M)Apr 10, 2004 · N812NK · Doug DC982 · Emergency LightingSDR GTIA040275Clip · dislodgedRSW - FOUND L1 DOOR SLIDE PACK LANYARD CLIP FELL OFF. INSTALLED SLIDE PACK LANYARD CLIP. CLIP SECURE. (M)Apr 10, 2004 · N800NK · Doug DC982 · Escape SlideSDR CALA0400353Skin · crackedINSPECTION FOUND A 1.5 INCH CRACK IN LEFT WING SKIN JUST FORWARD OF PANEL 1196C UPPER LEFT WING AREA, STA XOS 286. REPAIRED IAW ECRA 5720-01946.Apr 10, 2004 · N72822 · Doug DC982 · Wing, Plate/SkinSDR GTIA040273Cover · looseFLT 223 - ORD - FOUND L1 SLIDE PACK AND COVER CAME LOOSE FROM ENTRY DOOR. NO DAMAGE NOTED, REINSTALLED L1 SLIDE PACK AND COVER. (M)Apr 9, 2004 · N801NK · Doug DC982 · Escape SlideSDR AALA20040442Battery Pack · inoperativeTHREE EMERGENCY LIGHTS IN TAIL CONE INOPERATIVE. REPLACED BATTERY PACK AT B5-27 AND B5-28 FOR THREE EMERGENCY LIGHTS IN TAIL CONE. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 9, 2004 · N7514A · Doug DC982 · Emergency LightingSDR GTIA040272Sign · dislodgedEXIT SIGN AT AFT GALLEY FELL OFF ON TAKEOFF. RE-ATTACHED LUMINESCENT EXIT STRIP AT AFT GALLEY FLOOR AREA. (M)Apr 8, 2004 · N812NK · Doug DC982 · Emergency LightingSDR GTIA040264Sign · missingLGA - FOUND AFT GALLEY FLOOR EXIT GLOW SIGN MISSING. REPLACED MISSING AFT GALLEY FLOOR EXIT GLOW SIGN, OK FOR SERVICE. (M)Apr 7, 2004 · N800NK · Doug DC982 · Emergency LightingSDR AALA20040440Battery Pack · inoperativeDFW - CABIN CEILING EMERGENCY LIGHTS AT ROWS 22 THROUGH 27 INOPERATIVE. REPLACED BATTERY PACK AT B5-106 FOR CABIN CEILING EMERGENCY LIGHTS AT ROWS 22 THROUGH 27. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 7, 2004 · N7519A · Doug DC982 · Emergency LightingSDR AALA20040438Battery Pack · inoperativeDEN - AFT OVERHEAD EMERGENCY EXIT DOOR LIGHTS INOPERATIVE. REPLACED BATTERY PACK AT B5-105 FOR AFT OVERHEAD EMERGENCY EXIT DOOR LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 7, 2004 · N14551 · Doug DC982 · Emergency LightingSDR AALA20040439Battery Pack · inoperativeDEN - AFT ACCESSORY OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK AT B5-28 FOR AFT ACCESSORY OVERHEAD EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 7, 2004 · N14551 · Doug DC982 · Emergency LightingSDR CALA0400338Skin · crackedINSPECTION FOUND EXTERIOR FUSELAGE SKIN BULGED WITH RIVETS POPPING AROUND LOWER TCAS ANTENNA AND A 2 INCH CRACK WAS FOUND IN SKIN FORWARD OF TCAS ANTENNA AT STA 237. A REPAIR WAS INSTALLED IAW SRM 53-04, FIGURE 12C.Apr 7, 2004 · N72822 · Doug DC982 · Fuselage Main, Plate/SkinSDR AALA20040437Battery Pack · inoperativePHX - CEILING EMERGENCY LIGHTS AND SLIDE LIGHTS INOPERATIVE. REPLACED BATTERY PACK/CHARGERS B5-27 AND B5-28 FOR EMERGENCY CEILING LIGHTS AND SLIDE LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 7, 2004 · N7535A · Doug DC982 · Emergency LightingSDR AALA20040436Battery Pack · inoperativeDFW - CEILING EMERGENCY LIGHTS AT ROWS 13 THROUGH 16 INOPERATIVE. REPLACED BATTERY PACK B5-102 FOR CEILING EMERGENCY LIGHTS AT ROWS 13 THROUGH 16. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 6, 2004 · N295AA · Doug DC982 · Emergency LightingSDR AALA20040435Battery Pack · inoperativeDFW - CEILING EMERGENCY LIGHTS AT ROWS 28 THROUGH 30 INOPERATIVE. REPLACED BATTERY PACK FOR CEILING EMERGENCY LIGHTS AT ROWS 28 THROUGH 30. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 6, 2004 · N403A · Doug DC982 · Emergency LightingSDR AALA20040434Wire · inoperativeDFW - EMERGENCY ESCAPE PATH LIGHT AT FORWARD GALLEY WALL INOPERATIVE. REPAIRED WIRE FOR EMERGENCY ESCAPE PATH LIGHT AT FORWARD GALLEY WALL. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 6, 2004 · N33414 · Doug DC982 · Emergency LightingSDR CALA0400326Beltframe · corrodedINSPECTION FOUND BELTFRAME UNDER TIEDOWN RAIL CORRODED AT STA 1231 BETWEEN STRINGER 27L AND 28L IN AFT BAGGAGE BIN. THE CORRODED AREA OF BELTFRAME WAS CUT OUT AND REPAIR PARTS WERE INSTALLED IAW SRM 53-03, FIGURE 5.Apr 6, 2004 · N72822 · Doug DC982 · Fuselage Main, FrameSDR ASAA0480236Wire · brokenSEA - DURING LINE CHECK, FOUND EMERGENCY TRACK LIGHT INOPERATIVE UP TO ROW 7. REPAIRED SHORTED CONNECTOR WIRE. LIGHTS THEN OPERATED PROPERLY. (M)Apr 5, 2004 · N935AS · Doug DC982 · Light System WiringSDR ASMF20040403Transceiver · failedAIRCRAFT ARRIVED WITH FOLLOWING REPORTS: RADAR ANTENNA TURNED TO RIGHT. RADAR CONNECTOR WAS RESEATED AND CLEANED IAW MM 34-41-01. L ICE PROTECT TEMP HIGH LIGHT TURNED ON. LEAK WAS CORRECTED AND CLAMPS WERE TIGHTENED IAW MM 30-10-07. LEFT WINDSHIELD WIPER Apr 5, 2004 · N1003Y · Doug DC982 · Weather Radar SystemSDR AALA20040431Wire · shortedDFW - SEAT MOUNTED EMERGENCY LIGHTS AT ROWS 21 THROUGH 31 AND TAIL CONE SIDEWALL EMERGENCY LIGHTS INOPERATIVE. FOUND WIRES IN TAIL COMPARTMENT SHORTED. REPAIRED WIRES FOR SEAT MOUNTED EMERGENCY LIGHTS AT ROWS 21 THROUGH 31 AND TAIL CONE SIDEWALL EMERGENCY LIApr 5, 2004 · N291AA · Doug DC982 · Light System WiringSDR GTIA040260Lanyard · disconnectedFLLT - FLT 1751 - FOUND R1 SLIDE DEPLOYED WHEN CATERING OPENED DOOR. R1 SLIDE DID NOT DEPLOY, LANYARD CAME OFF COVER RESECURED LANYARD. (M)Apr 4, 2004 · N804NK · Doug DC982 · Emergency EquipmentSDR CALA0400319Floor Support · corrodedINSPECTION FOUND FLOOR SUPPORT CORRODED IN MID BAG BIN AT STA 788, LBL 24. REPAIRED FLOOR SUPPORT IAW SRM 51-70-5.Apr 4, 2004 · N72822 · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20040421Battery Pack · inoperativeMSP - OVERHEAD EMERGENCY LIGHT AT SEAT ROW 29 INOPERATIVE. REPLACED BATTERY PACK FOR OVERHEAD EMERGENCY LIGHT AT SEAT ROW 29. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 3, 2004 · N493AA · Doug DC982 · Emergency LightingSDR AALA20040428Pump · inoperativeDFW - INFLIGHT T1118 FUEL WOULD NOT FLOW FROM CENTER TANK AND ALL THREE AFT CENTER PUMP CIRCUIT BREAKERS WERE POPPED. LANDED WITHOUT INCIDENT AT DFW. RESET CIRCUIT BREAKERS, RAN PUMP AND TRANSFERRED FUEL. COULD NOT DUPLICATE. SYSTEM GROUND CHECKED NORMAL Apr 3, 2004 · N226AA · Doug DC982 · Aircraft Fuel Distribution SystemSDR GTIA040258Slide · unserviceableLGA - L1 DOOR SLIDE PRESSURE GAUGE LOW. REMOVED AND REPLACED L1 DOOR EVACUATION SLIDE. (M)Apr 2, 2004 · N829NK · Doug DC982 · Escape SlideSDR AALA20040419Slide · failedORD - GIRT BAR CABLE LOOSE. INSPECTED SLIDE PACK AND FOUND LANYARD FOR FIRING BOTTLE PULLED. SLIDE DID NOT DEPLOY. REPLACED R1 DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 2, 2004 · N286AA · Doug DC982 · Escape SlideSDR GTIA040259Lanyard · misroutedFLL - FOUND L1 DOOR ESCAPE SLIDE LANYARD IS ROUTED INCORRECTLY. REROUTED L1 DOOR ESCAPE SLIDE LANYARD. (M)Apr 1, 2004 · N801NK · Doug DC982 · Emergency EquipmentSDR AALA20040414Light · inoperativeDFW - SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHTING AT 8D, 20D, 26D, AND 31D INOPERATIVE. REPLACED THE SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHTING ASSEMBLY AT 8D, 20D, 26D, AND 31D. SYSTEM GROUND CHECKED NORMAL OPERATION.Apr 1, 2004 · N287AA · Doug DC982 · Emergency LightingSDR AALA20040408Battery Pack · dischargedDFW - AFT CABIN CEILING EMERGENCY LIGHTS AT L2-615, L2-671 AND L2-694 INOPERATIVE. REPLACED BATTERY PACK B5-27 AND RELAMPED AFT CABIN CEILING EMERGENCY LIGHTS AT L2-615, L2-671 AND L2-694. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 31, 2004 · N422AA · Doug DC982 · Emergency Lighting
Back to Mcdonnell Douglas DC-9-82