SDR CALA0300690Skin · crackedCRACK ON INNER SKIN FORWARD UPPER CORNER BY ROLLER ARM RIGHT MLG INNER DOOR. FABRICATED AND INSTALLED DOUBLER PER SRM 52-01 FIG 2.SDR CALA0300689Intercostal · crackedAFT BAG BIN INTERCOSTAL FOR CABIN FLOORBEAM IS CRACKED AT STA 1041 CENTER LINE OF A/C. FABRICATED AND INSTALLED DOUBLER PER SRM 51-70-04 AND STOP DRILLED CRACK IN INTERCOSTAL.SDR CALA0300696Floorbeam · crackedINTERCOSTAL BETWEEN STA 1271 - 1287 CABIN FLOORBEAM CRACKED AT CLIP NUTS. STOP DRILLED CRACKS AND INSTALLED REPAIR DOUBLERS PER SRM 53-01 FIG 2 SHEET 4.SDR AALA20031381Switch · failedDFW T9602/03 EN ROUTE MSY-DFW NOSE GEAR DID NOT RETRACT. RETURNED DFW AND LANDED WITHOUT INCIDENT. REPLACED LANDING GEAR HANDLE SWITCH AND RESERVICED NOSE GEAR STRUT. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR AALA20031371Flashlight · brokenSAT HOLD DOWN TAB FOR L1 DOOR EMERGENCY LIGHT/FLASHLIGHT BROKEN. REPLACED L1 DOOR EMERGENCY LIGHT/FLASHLIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR CALA0300686Stringer · crackedSTRINGER CRACKED AT STATION 1429 AT STRINGER 2 RIGHT (1 INCH). INSTALLED NEW STRINGER SECTION AND SPLICE PER EC/RA 5311-01132.SDR AALA20031367Battery Pack · dischargedDEN MID CABIN CEILING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR MID CABIN CEILING EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR AALA20031359Battery Pack · dischargedPHX AFT CABIN DROP CEILING PANELS AND AFT ACCESSORY CEILING AND SLIDE ILLUMINATION EMERGENCY LIGHTS INOPERATIVE. REPLACED B5-27 AND B5-28 BATTERY PACKS IN AFT RIGHT CEILING AT STATIONS 1322R AND 1338R. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR CALA0300681Charger · inoperativeTHE BATTERY CHARGER FOR EMERGENCY EXIT LIGHTS AT THE L-2 DOOR WAS FOUND INOPERATIVE. THE CHARGER WAS REMOVED AND REPLACED IAW MM 33-53-00, PAGE 401.SDR AALA20031365Battery · dischargedSTL FIRST CLASS OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY FOR FIRST CLASS OVERHEAD EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR AALA20031357Battery Pack · dischargedPHX FORWARD CABIN CEILING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD CABIN CEILING EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR AALA20031352Battery Pack · looseDFW OVERHEAD EMERGENCY PATH LIGHTS AT ROWS 4 5 AND 7 INOPERATIVE. RESEATED BATTERY PACKS FOR OVERHEAD EMERGENCY PATH LIGHTS AT ROWS 4 5 AND 7. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR AALA20031351Battery Pack · looseDFW OVERHEAD EMERGENCY AISLE LIGHTS FORWARD OF VAULT DOOR BETWEEN RT AND LT LAVS INOPERATIVE. RESEATED BATTERY PACK FOR OVERHEAD EMERGENCY AISLE LIGHTS FORWARD OF VAULT DOOR BETWEEN RIGHT AND LEFT LAVS. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR AALA20031349Battery · dischargedDFW FORWARD ENTRY AISLE GALLEY OVERHEAD EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY FOR FORWARD ENTRY AISLE GALLEY OVERHEAD EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031348Battery · dischargedDFW COCKPIT OVERHEAD EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY FOR COCKPIT OVERHEAD EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031346Battery Pack · dischargedDTW) EMERGENCY EXIT LIGHT ABOVE FORWARD OVERWING DOORS INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY EXIT LIGHT ABOVE FORWARD OVERWING DOORS. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR AALA20031343Battery · dischargedMIA, CABIN EMERGENCY LIGHTS INOPERATIVE. RECHARGED BATTERIES FOR CABIN EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR AALA20031354Engine · malfunctionedATL T1679/29 EN ROUTE ATL-MIA RIGHT HAND ENGINE LOW OIL PRESSURE. RETURNED ATL WITHOUT INCIDENT. REPLACED RIGHT HAND ENGINE. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR GTIA030959Slide · dislodgedACY - DURING MAINTENANCE THE CLEANERS OPENED L2 DOOR AND DROPPED SLIDE PACK ON RAMP. REMOVED AND REPLACED L-2 SLIDE. (M)SDR AALA20031338Battery Pack · dischargedSFO CENTER AND AFT POSITIONS CEILING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK ABOVE ROW 20DEF. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR GTIA030955Slide · damagedFLL - R-1 DOOR EMERGENCY/ESCAPE SLIDE WILL NOT STOW PROPERLY, GIRT OPENING DRAGS. REMOVED AND REPLACED R-1 DOOR EMERGENCY/SLIDE. (M)SDR MEX2003537Sensor · dirtyFLIGHT RETURNED DUE TO THE 'E/E DOOR OPEN' LIGHT TURNED ON AFTER 15 MINUTES. DURING REVISION AT MLM STATION THE DOOR WAS FOUND CLOSED. THE MECHANISM, DOOR AND THE SENSOR WERE CLEANED, TESTS WERE PERFORMED IAW MM 52-30, ALL CORRECT. (M)SDR AALA20031353Transmitter · faultyORD T650/26 EN ROUTE PHX-ORD RT HYDRAULIC PRESSURE LIGHT AND RT REV ACCUMULATOR LIGHT ON WHEN EXTENDING FLAPS AND SLATS. LANDED ORD WITHOUT INCIDENT. INSPECTION FOUND RT AND LEFT HYDRAULIC LEVELS WITHIN LIMITS. REPLACED RIGHT HAND FLUID QUANTITY TRANSMITTER SDR AALA20031329Battery Pack · dischargedDEN AFT RIGHT LAV OVERHEAD EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK FOR AFT RIGHT LAV OVERHEAD EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR GTIA030953Wire · brokenEMERGENCY LIGHT IN TAIL COMPARTMENT BELOW WATER SEPARATORS HAS BROKEN WIRE. REPAIRED BROKEN WIRE TO EMERGENCY LIGHT IN TAIL COMPARTMENT, BELOW WATER SEPARATORS. OPS CHECK OK. (M)SDR AALA20031326Slide · malfunctionedL2 DOOR SLIDE INADVERTENTLY AND UNSUCCESSFULLY DEPLOYED BY CABIN SERVICE. DRIVER OPENED AFT SERVICE DOOR WHILE SLIDE WAS ARMED. RUG TRUCK PLATFORM PREVENTED FULL DEPLOYEMENT OF SLIDE. REPLACED SLIDE ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031319Battery Pack · dischargedRDU VENTRAL STAIRS SIDE EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK FOR VENTRAL STAIRS SIDE EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031324Pump · inoperativeORD T702/23 EN ROUTE DEN-ORD RIGHT HYDRAULIC QUANTITY DECREASED TO 4 QUARTS. RIGHT QUANTITY WENT TO ZERO AFTER GEAR WAS EXTENDED. LANDED ORD WITHOUT INCIDENT. REPLACED RIGHT HAND ELECTRIC AUXILIARY HYDRAULIC PUMP. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031320Connector · looseDFW EMERGENCY LIGHTS AT SEATS 20D AND 2D INOPERATIVE. RESECURED CONNECTOR FOR SEATS 20D AND 2D EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031317Battery · dischargedDFW AFT VAULT DOOR OVERHEAD CEILING EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY FOR AFT VAULT DOOR OVERHEAD CEILING EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031309Connector · looseDFW EMERGENCY LIGHTS AT SEAT 20D INOPERATIVE. RESECURED LOOSE CONNECTOR FOR EMERGENCY LIGHTS AT SEAT 20D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031316Battery · dischargedDFW) ONE OF THREE TAILCONE EMERGENCY ILLUMINATION LIGHTS INOPERATIVE. REPLACED BATTERY FOR TAILCONE EMERGENCY ILLUMINATION LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION. CLOSEDSDR AALA20031327Brake · malfunctionedORD T2301/21 EN ROUTE ORD-DFW ON TAKEOFF RIGHT BRAKE DRAGS AND TEMPERATURE ROSE TO 200 DEGREES. ABORTED TAKEOFF. REPLACED RIGHT WHEEL, BRAKE AND SLEEVE ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031323Battery Pack · dischargedLAX INTERIOR CEILING EMERGENCY LIGHTS AT STATION 650-750 INOPERATIVE. REPLACED BATTERY PACK FOR INTERIOR CEILING EMERGENCY LIGHTS AT STATION 650-750. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031307Wire · damagedDFW TAIL CONE EJECT HANDLE EMERGENCY ILLUMINATION LIGHT INOPERATIVE. REPAIRED TAIL CONE EJECT HANDLE EMERGENCY ILLUMINATION LIGHT WIRES. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR CALA0300697Beam · corrodedINSPECTION FOUND STA 110 BULKHEAD BEAM WEB CORRODED AT MAIN BATTERY GROUND STUD HOLE. THE BEAM WEB WAS REPAIRED IAW ECRA 5310-04387.SDR CALA0300654Skin · corrodedINSPECTION FOUND RT WING LOWER T/E SKIN CORRODED AT REAR SPAR STA XRS 399-477. A SKIN DOUBLER WAS INSTALLED IAW ECRA 5731-01037.SDR CALA0300653Spar · corrodedINSPECTION FOUND RT WING FORWARD SPAR CORRODED AT STA XRS 258-335. REPAIRED IAW ECRA 5731-01040.SDR AALA20031299Module · inoperativeDFW AFT RIGHT OVERWING EMERGENCY EXIT LIGHT ASSEMBLY INOPERATIVE. REPLACED AFT RIGHT OVERWING EMERGENCY EXIT LIGHT BATTERY AND MODULE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031298Battery Pack · dischargedLAX INTERIOR CEILING EMERGENCY LIGHTS BETWEEN ROWS 18-21 INOPERATIVE. REPLACED BATTERY PACK FOR INTERIOR CEILING EMERGENCY LIGHTS BETWEEN ROWS 18-21. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031297Battery Pack · dischargedLAX FORWARD LEFT HAND OVERWING INTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED FORWARD LEFT HAND OVERWING INTERIOR EMERGENCY LIGHT BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR GTIA030905Light · will not testPORTABLE EMERGENCY LIGHT WILL NOT TEST. REMOVED AND REPLACED LIGHT ASSEMBLY, OPS CHECK OK. (M)SDR AALA20031293Battery Pack · dischargedSAN FIRST CLASS OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED FIRST CLASS OVERHEAD EMERGENCY LIGHTS BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031292Light · inoperativeDFW AFT SEAT MOUNTED EMERGENCY LIGHT AT 7D INOPERATIVE. REPLACED AFT SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY AT SEAT 7D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031291Battery Pack · dischargedDFW OVERHEAD EMERGENCY LIGHTS AFT OF ROW 31 INOPERATIVE. REPLACED OVERHEAD EMERGENCY LIGHTS AFT OF ROW 31 BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ASAA0380749Lanyard · disconnectedSEA PREFLIGHT CHECK, FOUND FORWARD SERVICE R1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)SDR AALA20031283Charger · inoperativeDFW OVERHEAD EMERGENCY LIGHT AT ROW 28 INOPERATIVE. REPLACED BATTERY CHARGER ASSEMBLY FOR OVERHEAD EMERGENCY LIGHTS FOR ROW 28. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031282Battery · dischargedSAT EMERGENCY CEILING LIGHTS ABOVE ROWS 8, 9 AND 10 ILLUMINATING VERY DIM. REPLACED BATTERY FOR EMERGENCY CEILING LIGHTS ABOVE SEATS 9D, 9E AND 9F. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031279Module · dischargedLGA EMERGENCY AISLE PATH LIGHT MODULE WILL NOT HOLD A CHARGE. REPLACED EMERGENCY AISLE PATH LIGHT MODULE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20031278Module · dischargedLGA EMERGENCY AISLE PATH LIGHTING MODULE AT L1 DOOR WILL NOT HOLD A CHARGE. REPLACED EMERGENCY AISLE PATH LIGHTING MODULE AT L1 DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.
Back to Mcdonnell Douglas DC-9-82