SDR ASOA03450Hinge · corrodedDURING A C-CHEC IN MCN, THE TOP HINGE SEGMENT ON THE PASSENGER DOOR TOP STEP WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE TOP HINGE SEGMENT ON THE PASSENGER DOOR TOP STEP IAW SRM 51-00. (M)SDR CALA0300532Cable · out of adjustTHE TAIL CONE INNER RELEASE HANDLE REQUIRED EXCESSIVE FORCE TO PULL. THE TAIL CONE CABLE WAS ADJUSTED, CLEANED AND LUBRICATED IAW MM 53-53-00. AN OPERATIONAL CHECK WAS GOOD.SDR CALA0300531Handle · lack of lubeTHE TAIL CONE HANDLE AFT ENTRY DOOR REQUIRED EXCESSIVE FORCE TO OPEN. THE DOOR HINGES AND HANDLE MECHANISM WERE LUBRICATED. A PULL TEST WAS PERFORMED IAW MM 53-53-00 AND OPERATIONAL CHECKS WERE GOOD.SDR AALA20031006Battery Pack · inoperativeDEN - DURING OVERNIGHT MAINTENANCE, EMERGENCY ESCAPE PATH LIGHTING WAS OBSERVED TO BE INOPERATIVE ABOVE FORWARD OVERWING EXITS. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR ASAA0380590Lanyard · disconnectedPREFLIGHT CHECK, FOUND FORWARD PAX L1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)SDR AALA20030997Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHTING INOPERATIVE, ON CEILING AT SEAT ROWS 16 THROUGH 22. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030711Skin · damagedFTW - FOUND SKIN CREASE AT FS 418 BETWEEN LONGERONS 16R AND 18R REQUIRES REPAIR. CUT OUT DAMAGED AREA FS 418 L16R TO 18R. FABRICATED FILLER, FINGER DOUBLER, DOUBLER. FABRICATED 3 STRAPS. INSTALLED FINGER DOUBLER, DOUBLER, FILLER AND STRAPS. (M)SDR GTIA030680Control Unit · malfunctionedLT ENGINE LOOP 'A' LIGHT ILLUMINATED. ACCOMPLISHED QRH PROCEDURE. REMOVED AND REPLACED CONTROL UNIT. OPS CHECK NORMAL. (M)SDR GTIA030677Slide · dislodgedMCO - FLT 1304 - L-2 SLIDE FELL OFF DOOR. RE-INSTALLED L-2 SLIDE ON TO DOOR. (M)SDR ASAA0380586Battery Pack · dischargedSEA LINE CHECK, FOUND OVERWING EMERGENCY LIGHTS INOPERATIVE, BATTERY PACK DISCHARGED. REPLACED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)SDR ASAA0380587Battery Pack · inoperativeSEA LINE CHECK - FOUND EMERGENCY TRACK LIGHTS INOPERATIVE, BATTERY PACK DISCHARGED. REPLACED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)SDR AALA20031003Fire Loop · failedAPU FIRE LOOP A ILLUMINATED DURNIG NR 2 ENGINE START. FOLLOWED FIRE DETECTION LOOP LIGHT PROCEDURE, NO TEST FOR LOOP B. MOVED SWITCH TO LOOP A AND OBSERVED APU FIRE LIGHT. FOLLOWED PROCEDURE FOR APU FIRE. LIGHT STAYED ON FOR 30 SECONDS AFTER FIRST BOTTLE, SDR AALA20030998Battery Pack · inoperativeDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING INOPERATIVE ON THE AFT CEILING. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030999Battery Pack · inoperativeDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING INOPERATIVE AT THE OVERWING EMERGENCY EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031000Battery Pack · inoperativeDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING WAS OBSERVED TO BE INOPERATIVE IN THE FORWARD CABIN. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20031002Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING INOPERATIVE AT THE FORWARD GALLEY AISLE FLOOR. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030707Floorboard · delaminatedFOUND SKIN DELAMINATED FLOOR BOARD MAIN CABIN RT INBOARD STATION 1193. FABRICATED FLOORBOARD. (M)SDR GTIA030696Web · corrodedFTW - FOUND CABIN LONG 18L WEB CORRODED STATION 274. CUT OUT DAMAGED WEB AREA. FABRICATED REPAIR DOUBLER. INSTALLED REPAIR DOUBLER. (M)SDR ASAA0380585Battery Pack · inoperativeSEA LINE CHECK, FOUND OVERWING EMERGENCY LIGHTS INOPERATIVE, BATTERY PACK DISCHARGED. REPLACED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)SDR AALA20030992Battery Pack · dischargedDEN - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHTING INOPERATIVE AT THE OVERWING EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030993Battery Pack · dischargedSAT - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHTING INOPERATIVE AT THE FORWARD GALLEY AND FLIGHT DECK. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030728Expansion Joint · crackedFTW - MAIN CABIN FLOOR PANEL CENTER STATION 886 TO STATION 946, EXPANSION JOINT CRACKED. REMOVED EXPANSION JOINT. FABRICATED EXPANSION JOINT. INSTALLED EXPANSION JOINT. (M)SDR AALA20030990Charger · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING INOPERATIVE AT SEAT ROW 20 THROUGH 22. REPLACED BATTERY CHARGER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030988Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING INOPERATIVE AT SEAT ROWS 29 THROUGH 31. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030989Battery Pack · not seatedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING INOPERATIVE AT THE AFT OVERWING CABIN SECTION. RESEATED BATTERIES IN PACK B5-105. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030729Skin Panel · corrodedFOUND CORROSION AND TOOL MARKS ON LE PANEL NR 1117C LEFT WING. TWO BLENDED AREAS FOUND TO BE OUT OF LIMITS. FABRICATED REPAIR DOUBLER. INSTALLED DOUBLER. (M)SDR GTIA030706Floorboard · delaminatedFTW - FOUND BROKEN INSERT, EDGE DELAMINATED CABIN FLOORBOARD STATION 542-617. FABRICATED NEW CABIN FLOORBOARD. (M)SDR GTIA030705Web · crackedFTW - FOUND PAX CABIN LEFT SIDE AFT OF DOOR JAMB FS 207 LONGERON 11L SKIN WEB EAR IS CRACKED. REMOVED DAMAGED PART OF THE SKIN WEB. FABRICATED FILLER AND DOUBLER. INSTALLED FILLER AND DOUBLER. (M)SDR AALA20030986Light · inoperativeDURING OVERNIGHT MAINTENANCE, TECHNICIAN OBSERVED EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT SEAT 14D. REPLACED SEAT MOUNTED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030980Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING INOPERATIVE AT THE AFT SERVICE DOOR EXIT. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030987Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTING INOPERATIVE AT ENTRY DOOR. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030712Floorboard · delaminatedFTW - FOUND DELAMINATED AND MISSING INSERT, MISSING EDGE FILLER FLOORBOARD MAIN CABIN STATION 1022-1117. FABRICATED NEW FLOORBOARD. (M)SDR GTIA030704Floor Panel · crackedFTW - FOUND PAX CABIN FLOOR PANEL RBL 44 INCHES STATION 465-547 HAS CRACKED/DAMAGE ON EDGE/INSERT BROKEN OUT. FABRICATED FLOOR PANEL. (M)SDR GTIA030703Floor Panel · crackedFTW - FOUND PASSENGER CABIN STATION 826-864, FLOOR PNL LEFT SIDE INBOARD HAS PUNCTURE/CRACKS. FABRICATED NEW FLOOR PANEL. (M)SDR GTIA030702Floor Panel · crackedFTW - FLIGHT COMPARTMENT STATION 120-160, LEFT SIDE FLOOR PANEL HAS PUNCTURE/CRACK. REPAIRED FLOOR PANEL. (M)SDR GTIA030682Floor Panel · crackedFLIGHT COMPARTMENT STATION 120-160 RIGHT SIDE FLOOR PANEL HAS CRACK/DAMAGED. REPAIRED CRACK AND DAMAGE ON FLOOR PANEL. (M)SDR GTIA030681Floor Panel · crackedFOUND PAX CABIN, STATION 864 TO 886 LT SIDE INBOARD PANEL HAS CRACK/DAMAGED AT CORNERS. FABRICATED PANEL. (M)SDR GTIA030756Web · corrodedFOUND FORWARD CABIN STATION 200 TO 218 LBL 45 INCHES HAS CORROSION ON WEB, UNDER SEAT TRACK ATTACH. REMOVED CABIN WEB. FABRICATED WEB. INSTALLED CABIN WEB. (M)SDR AALA20030979Oven · smokeFOUND GALLEY INBOARD OVEN PRODUCES LARGE AMOUNT OF SMOKE WITH STRONG BURNING ODOR WHEN IN OPERATION. PULLED CIRCUIT BREAKER, NO SMOKE. OVEN REPLACED BY MAINTENANCE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030976Battery · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT INOPERATIVE AT THE FORWARD AUXILIARY LIGHT POSITION. REPLACED BATTERY B5-103. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030970Socket · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT INOPERATIVE AT SEAT 22D. REPLACED LIGHT SOCKET. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030975Battery · dischargedSAT - FLT 1854 - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT INOPERATIVE AT AFT STAIRS. REPLACED BATTERY B5-28. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030701Seat Track · corrodedFTW - FOUND FORWARD CABIN, STATION 200, LBL 22 INCHES HAS CORROSION AT SUPPORT END FITTING INBOARD SEAT TRACK ATTACH. REMOVED TRACK STATION 200 TO 234. FABRICATED NEW TRACK. FABRICATED ATTACH FITTING. INSTALLED NEW TRACK AND ATTACH FITTING. (M)SDR GTIA030799Light · inoperativeFTW - FOUND TAIL COMPARTMENT EMERGENCY EXIT LIGHTS UPPER AND LOWER INOPERATIVE, MIDDLE LIGHT GOOD. REMOVED AND REPLACED BOTH LIGHT ASSEMBLIES. (M)SDR GTIA030803Seat Track · corrodedFOUND SEAT TRACKS LEFT STA 826 TO 1307 BARE METAL, NICKS LIGHT CORROSION, ALL THREE TRACKS. REMVOED OUTBOARD SEAT TRACK STA 826-1307 LOCATED AND DRILLED OUTBOARD SEAT TRACK AND LOCATED AND DRILLED SPLICES INSTALLED OUTBOARD SEAT TRACK AND SPLICES. REMOVED INSDR GTIA030804Seat Track · corrodedFOUND SEAT TRACKS RIGHT STA 200-826 BARE METAL, NICKS LIGHT CORROSION. SEAT TRACKS COMMON TO RBL 22 & 54 FROM STA 200-826 OUT OF LIMITS. REMOVED OUTBOARD SEAT TRACK RBL 54 FROM STA 200-826. REMOVED INBOARD SEAT TRACK RBL 22 FROM STA 200-826. FABBED SEAT TRSDR GTIA030810Seat Track · corrodedFOUND SEAT TRACKS RIGHT STATION 826 TO STATION 1307 BARE METAL, NICKS, LIGHT CORRODED, ALL THREE TRACKS. SEAT TRACK RBL 22 AND RBL 54 FROM 826 TO 1307 IS OUT OF LIMITS. REMOVED OUTBOARD SEAT TRACK STATION 826 TO 1307 RBL 54. REMOVED SEAT TRACK STATION 200 TOSDR AALA20030968Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS WERE INOPERATIVE AT SEAT 26G. REPAIRED BROKEN WIRE AT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030969Socket · defectiveDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT WAS INOPERATIVE AT SEAT 7D. REPLACED LIGHT SOCKET. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030971Charger · inoperativeBNA - FLT 1422 - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT INOPERATIVE IN AFT TAIL CONE. REPLACED BATTERY CHARGER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Back to Mcdonnell Douglas DC-9-82