Mcdonnell Douglas DC-9-82

Service difficulty reports · 23,866

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC982'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASAA0380571Light · inoperativeSEA - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY DOOR INOPERATIVE. REPLACED LIGHT ASSEMBLY. LIGHT THEN OPERATED PROPERLY. (M)Aug 31, 2003 · N954AS · Doug DC982 · Emergency LightingSDR AALA20030927Wire · looseDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHTS WERE INOPERATIVE ON AFT OF WING IN CABIN. LOOSE WIRE FOUND AND REPOSITIONED. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 30, 2003 · N513AA · Doug DC982 · Light System WiringSDR ASAA0380569Frame · corrodedDURING C-CHECK, FOUND FRAME CORRODED AT FS 1287 BETWEEN LONGERON 28L AND 28R. REPLACED DAMAGED SECTION IAW SRM 53-03 AND 53-01. (M)Aug 29, 2003 · N967AS · Doug DC982 · Fuselage Main, FrameSDR GTIA030801Angle · crackedFOUND LT ENGINE PYLON BOTTOM SIDE AT FUSELAGE ATTACH ANGLE CRACKED. CUT OUT DAMAGED AREA. FABRICATED FILLER AND DOUBLER. INSTALLED FILLER AND DOUBLER. (M)Aug 29, 2003 · N830NK · Doug DC982 · Nacelle/Pylon Miscellaneous StructureSDR AALA20030923Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHTS WERE INOPERATIVE ON LEFT SERVICE DOOR AND LEFT FORWARD DOOR. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 29, 2003 · N276AA · Doug DC982 · Emergency LightingSDR AALA20030924Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHTS WERE INOPERATIVE AT SEAT 17D. REPLACED THE EMERGENCY LIGHT ASSEMBLY AT SEAT 17D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 29, 2003 · N276AA · Doug DC982 · Emergency LightingSDR AALA20030928Charger · inoperativeLAS - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS WERE NOT OPERATING PROPERLY. REPLACED BATTERY CHARGER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 29, 2003 · N513AA · Doug DC982 · Emergency LightingSDR ASAA0380568Longeron · corrodedDURING C-CHECK, FOUND LONGERON 28R CORRODED THROUGH AFT OF FS 1287. REPLACED DAMGED SECTION FROM FS 1287-1309. SPLICED IAW EA 53-10-02243. (M)Aug 28, 2003 · N967AS · Doug DC982 · Fuselage Main, Longeron/StringerSDR ASAA0380567Frame · corrodedOAK - DURING C-CHECK, FOUND FRAME CORRODED AT FS 1212 BETWEEN LONGERON 28L AND 29R. REPLACED FRAME IAW SRM 51-30-2 AND 51-30-5. (M)Aug 28, 2003 · N967AS · Doug DC982 · Fuselage Main, FrameSDR ASAA0380566Intercostal · corrodedOAK - DURING C-CHECK, FOUND INTERCOSTAL CORRODED AT FS 1309-1322 ON LEFT SIDE BETWEEN LONGERON L28 AND L27. REPLACED INTERCOSTAL. (M)Aug 28, 2003 · N967AS · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20030911Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 28, 2003 · N577AA · Doug DC982 · Emergency LightingSDR GTIA030720Seat Track · corrodedFTW - FOUND LEFT OUTBOARD SEAT TRACK HAS CORROSION AND GOUGES SEVERAL AREAS FROM FS 1050-1136. FOUND LEFT OUTBOARD SEAT TRACK FS 1050-1136 OUT OF LIMITS. REMOVED LEFT OUTBOARD SEAT TRACK. LOCATED AND DRILLED NEW TRACK. INSTALLED NEW TRACK. (M)Aug 28, 2003 · N829NK · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR GTIA030721Seat Track · corrodedFTW - FOUND RIGHT INBOARD SEAT TRACKS CORRODED FROM STATION 790-1200 IN SEVERAL PLACES. REMOVED SEAT TRACK RIGHT INBOARD STATION 1032 TO STATION 1309. FABRICATED NEW SEAT TRACK. INSTALLED RIGHT INSTALLED RIGHT INBOARD SEAT TRACK. (M)Aug 28, 2003 · N829NK · Doug DC982 · Fuselage, Seat/Cargo Attach FittingsSDR GTIA030672Fitting · corrodedFOUND AFT PIT CORRODED ANGLE AT FS 1155 4 INCHES RBL AND 1 CORRODED FASTENER AT FS 1145, SHORT FRAME, 4 INCHES RBL. AFTER FURTHER INSPECTION DISCOVERED FLOOR SUPPORT STATION 1148 4 INCHES RBL CRACKED. REMOVED FLOOR SUPPORT RECEIVED NEW FLOOR SUPPORT FITTING.Aug 27, 2003 · N829NK · Doug DC982 · Fuselage Main, Attach FittingsSDR GTIA030659Acm · odorWITH RIGHT AC PACK ON, OILY ODOR IN THE CABIN, ODOR CEASES WITH RIGHT PACK OFF, OIL FOUND ON SIDE PANELING AT THE END RIGHT OVERWING EXIT. INSPECTED RIGHT ACM FOUND VERY LITTLE, CLEANED OIL AND RAN ACM NO LEAKS NOTED, NO ODOR IN CABIN, OPS CHECKS NORMAL. (M)Aug 27, 2003 · N800NK · Doug DC982 · Cabin Cooling SystemSDR ASAA0380565Lanyard · disconnectedSJC PREFLIGHT CHECK, FOUND FORWARD PAX L1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)Aug 26, 2003 · N953AS · Doug DC982 · Escape SlideSDR AALA20030910Battery Pack · dischargedDFW - DURING OVERNIGHT MAINTENANCE, TAIL COMPARTMENT EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 26, 2003 · N432AA · Doug DC982 · Emergency LightingSDR GTIA030719Frame · corrodedFTW - FOUND MID PIT HAS CORROSION AT FRAME STATION 522, STATION 598. FOUND OUT OF LIMITS AT STATION 522. FABRICATED REPAIR DOUBLER. INSTALLED REPAIR ANGLE AND DOUBLER. (M)Aug 26, 2003 · N829NK · Doug DC982 · Fuselage Main, FrameSDR AALA20030904Battery Pack · inoperativeAFT LEFT SERVICE DOOR INTERIOR EMERGENCY EXIT SIGN LIGHT FORWARD OF THE DOOR IS INOPERATIVE. REPLACED BATTERY PACK AB5 4 IN LEFT GALLEY CEILING NEAR LEFT SERVICE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 26, 2003 · N585AA · Doug DC982 · Emergency LightingSDR GTIA030657Inlet Guide Vane · crackedENGINE 2-217A ESN 708450 INLET GUIDE VANE HAS ROOT AND INNER SHROUD WELD TO SHROUD CRACKED. REMOVED AND REPLACED IGV CASE. (M)Aug 26, 2003 · N812NK · Doug DC982 · Engine Air Intake SystemSDR GTIA030656Blade · damagedNR 2 ENGINE 1ST STAGE FAN BLADE IS MANGLED BEYOND BLENDABLE LIMITS. REMOVED AND REPLACED TWO C-1 BLADES IAW MD-80 A/C MM REV 76 REV 76 SECTION 72-33-21. COMPLIED WITH TEST 6 AND 1 PER SECTION 72-00-00 PER TIMCO ENGINE CENTER CERT T48R384Y. (M)Aug 26, 2003 · N812NK · Doug DC982 · Turbine Engine Compressor SectionSDR CALA0300499Strut · lowTHE NOSE GEAR WOULD NOT RETRACT AFTER TAKEOFF FROM LAS. RECYCLING THE GEAR DID NOT HELP. THE AIRCRAFT WAS RETURNED TO LAS WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE NLG SHOCK STRUT INFLATION LOW. THE SHOCK STRUT WAS SERVICED IAW MM 32-31-02. Aug 26, 2003 · N14839 · Doug DC982 · Nose/Tail Landing Gear Strut/AxleSDR GTIA030743Web · crackedFTW - FORWARD PIT CEILING FS 225 LBL 57 FEET WEB CRACKED AND CORRODED. REMOVED DAMAGED WEB. DRILLED AND LOCATED NEW WEB AND DOUBLER. INSTALLED NEW WEB/DOUBLER. (M)Aug 25, 2003 · N829NK · Doug DC982 · Fuselage Miscellaneous StructureSDR AALA20030903Battery Pack · inoperativeRIGHT NR 2 EMERGENCY EXIT SIGN INOPERATIVE FOR NR 2 DOOR. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 25, 2003 · N241AA · Doug DC982 · Emergency LightingSDR AALA20030895Battery · inoperativeDURING OVERNIGHT MAINTENANCE, EXTERIOR EMREGENCY LIGHTS, LEFT AND RIGHT, INOPERATIVE. REPLACED BATTERY IN AFT CARGO COMPARTMENT. SYSTEM GROUND CHECKED NORMAL OPERAITON. (M)Aug 24, 2003 · N467AA · Doug DC982 · Emergency LightingSDR AALA20030894Battery Pack · inoperativeDURING OVERNIGHT MAINTENANCE, AFT CEILING EMERGENCY EXIT LIGHTS AND EVACUATION SLIDE LIGHTS INOPERATIVE. REPLACED AFT RIGHT LAV EMERGENCY EXIT LIGHT BATTERY PACK AND CHARGERS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 24, 2003 · N467AA · Doug DC982 · Emergency LightingSDR AALA20030897Battery Pack · inoperativeDURING OVERNIGHT MAINTENANCE, WHEN BATTERY MASTER WAS PLACED IN OFF POSITION OR EMERGENCY LIGHT SWITCH WAS PLACED IN THE ARM POSTION THE COCKPIT, FORWARD ENTRY, SERVICE ENTRY AND STATION 213 EMERGENCY LIGHTS CAME ON. REPLACED BATTEYR PACK AT B5 23. SYSTEM GRAug 24, 2003 · N487AA · Doug DC982 · Emergency LightingSDR AALA20030896Battery Pack · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY ESCAPE PATH LIGHTING ROWS 18 THROUGH 21 INOPERATIVE. REPLACED BATTERY PACK 135 AND 104. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 24, 2003 · N7508 · Doug DC982 · Emergency LightingSDR 2004F00050Connector · looseDURING MAINTENANCE IN PIE, THE MID CABI HAD SECTION OF EMERGENCY PATH LIGHTING INOPERATIVE. A LOOSE WIRE TO THE CONNECTOR AT MID CABIN SECTION WAS FOUND, RESECURED IAW MD80 MM 33-53-0. OPS CHECK GOOD. (M)Aug 23, 2003 · N418GE · Doug DC982 · Emergency LightingSDR GTIA030732Warning Light · illuminatedA/C 823 HAS AUTO SLAT FAIL LIGHT ON TAXI OUT. UNSCHEDULED CHANGE A/C EN ROUTE. (M)Aug 23, 2003 · N823NK · Doug DC982 · Central WarningSDR AALA20030898Battery Pack · inoperativeDURING OVERNIGHT MAINTENANCE, INTERIOR CEILING EMERGENCY ESCAPE PATH LIGHTING ROWS 27 THROUGH 31 INOPERATIVE. REPLACED BATTERY PACK AT B5 107. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 23, 2003 · N286AA · Doug DC982 · Emergency LightingSDR GTIA030812Door Frame · corrodedFOUND AFT PIT LOWER DOOR JAMB BEAM CORRODED. (M)Aug 22, 2003 · N829NK · Doug DC982 · Fuselage Main, StructureSDR AALA20030900Controller · malfunctionedEN ROUTE MIA-LGA, AT 29,000 FT PACK FLOW GAUGES WENT TO ZERO AND AIRCRAFT LOST ALL PRESSURIZATION. ALL MASK DEPLOYED. AIRCRAFT REMOVED FROM SERVICE AND FERRIED TO DFW. INSPECTED DUCTS IN TAIL COMPARTMENT AND WHEEL WELL. PERFORMED BITE OF CONTROLLERS. UNABAug 22, 2003 · N70524 · Doug DC982 · Cabin Pressure ControllerSDR AALA20030887Battery Pack · dischargedFORWARD ENTRY EMERGENCY LIGHT INOPERATIVE AT LOCATIONS B5-23. REPLACED BATTERY PACK. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 22, 2003 · N7546A · Doug DC982 · Emergency LightingSDR MEX2003384Clamp · defectiveFLT 266 - MEX-REX - AIRCRAFT ARRIVED WITH CAPTAIN REORTING THAT AFTER TAKEOFF, TAIL COMPARTMENT TEMP HIGH LIGHT CAME ON. THE AUGMENTATION VALVE AND REGULATOR VALVE DUCTS CLAMPS WERE REPLACED IAW MM 36-10-00 AND TEMPERATURE SENSORS WERE CLEANED IAW MM 36-20-02Aug 22, 2003 · N501AM · Doug DC982 · Pneumatic Distribution SystemSDR ASAA0380560Lanyard · damagedSEA PREFLIGHT CHECK, FOUND FORWARD SERVICE R1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND BROKEN. REPLACED LANYARD. (M)Aug 21, 2003 · N953AS · Doug DC982 · Escape SlideSDR GTIA030731Warning Light · illuminatedON STABILZED APPROACH WITH FLAPS UP THE STALL INDICATION FAILURE LIGHT ILLUMINATED FOR ONE MINUTE THEN LIGHT REMAINED ON FOR REST OF THE APPROACH, ALSO HEADING LIGHT ON BOTH FMA'S WAS ILLUMINATED, HEADINGS WERE SPLIT 6-7 DEGREES BOTH LIGTHS ON STEADY. UNSCHEDAug 21, 2003 · N823NK · Doug DC982 · Central WarningSDR AALA20030882Battery Pack · inoperativeORD - EMERGENCY EXIT LIGHTS ON SEATS FLASH INTERMITTENTLY IN FLIGHT. REPLACED TRACK LIGHTING BATTERY PACKS AT OVERHEAD PANEL ABOVE AFT SERVICE DOOR AND BOTH BATTERY PACKS AT OVERHEAD PANEL ABOVE SEAT 20DEF. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 21, 2003 · N276AA · Doug DC982 · Emergency LightingSDR AALA20030879Connector · looseEMERGENCY PATH LIGHTING INOPERATIVE FROM ROW 20 TO BACK OF AIRCRAFT. CLEANED AND SECURED CONNECTION AT ROW 20 DEF. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 20, 2003 · N513AA · Doug DC982 · Emergency LightingSDR AALA20030880Switch · defectiveORD - EMERGENCY LIGHT ARMING SWITCH AT FORWARD FLIGHT ATTENDANT STATION INOPERATIVE. REPLACED SWITCH. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 20, 2003 · N276AA · Doug DC982 · Emergency LightingSDR ASAA0380561Line · blockedPDX LINE CHECK, NR 1 FIRE BOTTLE WAS DISCHARGED TO EXTINGUISH APU FIRE. DISCOVERED LINE WAS PARTIALLY BLOCKED WITH DISCHARGE HEAD SHRAPNEL. REPLACED FLEX LINE. (M)Aug 19, 2003 · N935AS · Doug DC982 · Fire Bottle, FixedSDR AALA20030909Battery Pack · dischargedLGA - DURING OVERNIGHT MAINTENANCE, AFT CABIN EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED AFT CABIN EMERGENCY EXIT LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 18, 2003 · N403A · Doug DC982 · Emergency LightingSDR AALA20030874Connector · looseSLIDE HANDLE EMERGENCY LIGHT INOPERATIVE. RESEATED LOOSE CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 18, 2003 · N7536A · Doug DC982 · Escape SlideSDR AALA20030869Wire · damagedDFW - FOUND R1 EXIT SIGN EMERGENCY LIGHT INOPERATIVE. SPLICED WIRE FOR EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 18, 2003 · N7543A · Doug DC982 · Light System WiringSDR AALA20030862Socket · inoperativeDURING OVERNIGHT MAINTENANCE, SEAT 7D AFT EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED SEAT 7D EMERGENCY EXIT LIGHT SOCKET. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 17, 2003 · N7548A · Doug DC982 · Emergency LightingSDR AALA20030858Wire · inoperativeDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT INOPERATIVE IDENTIFIER BETWEEN FORWARD GALLEY AND FIRST CLASS ARROWS INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT WIRE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 17, 2003 · N7548A · Doug DC982 · Light System WiringSDR CALA0300530Fan · seizedA/C HAD A CHRONIC INFLT PROBLEM WITH AN ELECTRICAL ODOR AFT. TROUBLESHOOTING PERFORMED. SOURCE OF ODOR APPEARED TO BE COMING FROM AFT GALLEY. COFFEEMAKERS, OVENS, & ACCESS PANELS INSPECTED, NO EVIDENCE OF BURNING. PACK BURNOUT PERFORMED & COALESCER BAGS R & R.Aug 17, 2003 · N12811 · Doug DC982 · Air Distribution FanSDR AALA20030861Light · inoperativeDURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT ON FORWARD GALLEY WALL INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 16, 2003 · N447AA · Doug DC982 · Emergency LightingSDR AALA20030860Connector · inoperativeDURING OVERNIGHT MAINTENANCE, CEILING EMERGENCY EXIT LIGHT AT ROW 18-21 INOPERATIVE. RE-SEATED EMERGENCY EXIT LIGHT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 16, 2003 · N218AA · Doug DC982 · Emergency LightingSDR AALA20030867Relay · failedDFW - DURING OVERWING EMERGENCY LIGHTS INOPERATIVE FROM FLIGHT ATTENDANT SWITCH. REPLACED RELAY R2 271. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Aug 15, 2003 · N14551 · Doug DC982 · Emergency Lighting
Back to Mcdonnell Douglas DC-9-82