Mcdonnell Douglas DC-9-82
Service difficulty reports · 23,866
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC982' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC982' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20030313Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, SEAT MOUNTED EMEGENCY EXIT PATH LIGHTING AT SEAT 9B INOPERATIVE. REPLACED SEAT MOUNTED EMERGENCY EXIT PATH LIGHTING AT SEAT 9B ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR GTIA030160Control Cable · out of rigTAILCONE WILL NOT RELEASE WHILE ACCOMPLISHING STEP D OF WORKCARD N53038. RE-RIGGED TAILCONE PULL CABLE AT THE PULL CABLE HOUSING, OPS CHECKED GOOD.SDR FE5F200300002Tube · looseWhen A/C taxied to the gate position, tower informed smoke is observed from R/H ENG site and then cabin crew reported HYD ordor is smelled in the cabin. Captain shutdown the APU and related symptom disappeared and then L/H HYD QTY indicated 7 QT remained. MechSDR CALA0300115Battery Pack · inoperativeINSPECTION FOUND BOTH THE R/H AND L/H EXTERIOR EMERGENCY LIGHTS INOPERATIVE. THE BATTERY PACK WAS REMOVED AND REPLACED AND OPERATION CHECKED GOOD.SDR AALA20030340Skin · damagedFOUND DEEP STATIC DISCHARGE STATION 615 L21R. INSTALLED LONGERON SPLICE AND EXTERNAL PATCH TO DAMAGED AREA PER SRM 53-02-00- FIG 8. (M)SDR AALA20030339Frame · bentTUL - FOUND FRAME IN FORWARD CARGO LOWER LEG BENT, SIDE OF FRAME DEFORMED AND RADIUS FROM DENT IN FUSELAGE. REMOVED AND REPLACED FRAME IN FWD CARGO PER SRM 51-10-04. (M)SDR CALA0300159Skin · dentedMAINTENANCE FOUND A CREASE IN THE AFT UPPER CORNER OF THE OUTER SKIN OF THE AFT CARGO DOOR. THE CREASED AREA OF DOOR SKIN WAS REPAIRED IAW ECRA 5232-01023. A DIP WAS ISSUED TO PERFORM INSPECTION OF THE REPAIR IAW ECRA 5232-01023 BEGINNING AT OR BEFORE 45,815 CSDR AALA20030341Door Frame · corrodedTUL - FOUND MID CARGO DOOR BEAM CORRODED BEYOND LIMITS. REMOVED AND REPLACED BEAM PER SRM 51-01-00. (M)SDR AALA20030323Seat Track · corrodedFOUND CORROSION ON NR 1 SEAT TRACK STATION 1024. REPLACED NR 1 SEAT TRACK FROM STATION 864 TO 1031 AND SPLICED TWO PLACES PER SRM 53-05-00. (M)SDR GTIA030162Screw · missingLEFT FORWARD OVERWING EMERGENCY EXIT WINDOW IS STUCK CLOSED. FORWARD SCREW ON EXIT COVER MISSING THUS JAMMING DOOR CLOSED. INSTALLED SCREW ON COVER, DOOR NOW FUNCTIONS PROPERLY.SDR ZW0A0303101Battery Pack · dischargedTHE OVERHEAD EMERGENCY LIGHT AT SEATS 8 THRU 12 WERE INOPERATIVE. REPLACED THE BATTERY PACK. CHECK-C 6-28-2002 STL.SDR MEX2003064Engine · lack of lubeFLT 940 - MEX-MTY, AIRCRAFT RETURNED TO PLATFORM, DURING TAXIING THE LOW QUANTITY OIL LIGHT OF ENGINE NR 2 TURNED ON. THE OIL LEVEL WAS VERIFIED BEING NECESSARY TO ADD 7 QUARTS. THE ENGINE MAIN OIL FILTER WAS INSPECTED IAW MM 79-20-06, ALL CORRECT FOR SERVISDR AALA20030302Light · inoperativeMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT AFT DOOR SERVICE LIGHT INOPERATIVE. REPLACED AFT SERVICE DOOR EMERGENCY EXIT LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030297Battery · not seatedDFW - DURING OVERNIGHT MAINTENANCE, CEILING EMERGENCY EXIT LIGHTS FROM 8D-11D INOPERATIVE. RESEATED EMERGENCY EXIT LIGHT BATTERY FOR SEATS 8D-11D. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030296Battery · dischargedDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT ASSEMBLY IN TAIL CONE INOPERATIVE. RESEATED EMERGENCY EXIT LIGHT BATTERY FOR TAIL CONE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA20030299Battery · disconnectedDFW - DURING OVERNIGHT MAINTENANCE, OVERHEAD EMERGENCY EXIT LIGHTS ROW 23-26 INOPERATIVE. REATTACHED EMERGENCY EXIT LIGHT BATTERY AT SEAT 23-26. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR CALA0300108Frame · corrodedINSPECTION FOUND BELTFRAME LOWER CHANNEL AND WEB CORRODED AT STA 1309 FROM LONGERON 28L TO 28R. REPAIRED IAW SRM 53-03, PAGE 04A, FIGURE 2A.SDR CALA0300107Cable · out of rigTHE TAILCONE FAILED TO DROP WITHIN SPECIFICATIONS AT ALL THREE POSITIONS DURING FUNCTIONAL TEST. THE PULL EXCEEDED 35 POUNDS. THE TAILCONE CABLES WERE ADJUSTED IAW 53-53-00.SDR CALA0300106Light · inoperativeTHE TAILCONE SLIDE LIGHT FAILED BATTERY TEST. THE SLIDE ASSEMBLY WAS REMOVED AND REPLACED IAW MM 25-62-01.SDR ASAA0380227Shear Tie · corrodedOKC - DURING 30K CHECK, FOUND SHEAR TIE CORRODED. REMOVED CORROSION. FABRICATED AND INSTALLED REPAIR SPLICE PER SRM. (M)SDR ASAA0380226Floorboard · corrodedOKC - DURING 30K CHECK, FOUND MID CARGO FLOORBOARD PUNCTURED AND CORRODED AT FASTENER HOLES. REPLACED FLOOR PANEL PER SRM. (M)SDR ASAA0380219Cargo Track · corrodedOKC - DURING 30K CHECK, FOUND AFT CARGO TRACK CORRODED. REPLACED DAMAGED SECTION OF TRACK PER SRM. (M)SDR ASAA0380218Support · corrodedOKC - DURING 30K CHECK, FOUND CORROSION ON CENTER PANEL MOUNTING SUPPORT. REPLACED FLOOR PANEL MOUNTING SUPPORT. (M)SDR ASAA0380217Support · crackedOKC - DURING 30K CHECK, FOUND TAIL CONE RELEASE PANEL SUPPORT ARM CRACKED. APPLIED FIBERGLASS OVERLAY TO SUPPORT ARM PER SRM. (M)SDR ASAA0380216Web · crackedOKC - DURING 30K CHECK, FOUND FORWARD CARGO AREA LEFT CUSP WEB CRACKED. REPLACED CUSP WEB PER SRM. (M)SDR ASAA0380228Seat Track · corrodedOKC - DURING 30K CHECK, FOUND CABIN SEAT TRACK CORROSION AT FASTENERS. REPLACED DAMAGED SECTION OF SEAT TRACK PER SRM. (M)SDR ASAA0380256Skin · damagedOKC - DUIRNG 30K CHECK, FOUND FUSELAGE SKIN DAMAGED BETWEEN LONGERONS 19R AND 20R AT STATION 365. INSTALLED REPAIR DOUBLER PER SRM. (M)SDR ASAA0380255Frame · crackedOKC - DURING 30K CHECK, FOUND FRAME AT FS 83.5 CRACKED AT RBL 9. STOP DRILLED CRACK. INSTALLED DOUBLER PER SRM. (M)SDR ASAA0380254Frame · corrodedOKC - DURING 30K CHECK, FOUND AFT CARGO AREA HAS FRAME CORRODED. REMOVED FRAME CORROSION AND INSTALLED REPAIR ANGLES PER SRM. (M)SDR ASAA0380225Vane · dentedOKC - DURING 30K CHECK, FOUND RIGHT INBOARD FLAP VANE DENTED ON OUTBOARD END LOWER SURFACE. REMOVED DAMAGED AREA AND INSTALLED FILLER AND DOUBLER PER SRM. (M)SDR ASAA0380246Mount · gougedOKC - FOUND DURING 30K CHECK, RIGHT WING NR 1 INBOARD SLAT CLOSE OUT MOUNT BROKEN. REPLACED BRACKET PER SRM. (M)SDR ASAA0380245Step · crackedOKC - FOUND DURING 30K CHECK, AFT ENTRY STAIRS HAVE CRACK ON LOWER STEP. BLENDED OUT CRACKS PER SRM. (M)SDR ASAA0380244Longeron · corrodedOKC - DURING 30K CHECK, FOUND LONGERON 28L IS CORRODED AT FLANGE OF REPAIR SPLICE. REMOVED DAMAGED SECTION. SPLICED IN NEW SECTION PER SRM. (M)SDR ASAA0380252Hinge · gougedOKC - DURING 30K CHECK, FOUND AFT GALLEY SERVICE DOOR HINGE FITTING GOUGED. BLENDED GOUGE PER ASA EA 5240-01102. (M)SDR ASAA0380251Hinge Fitting · corrodedOKC - DURING 30K CHECK, FOUND RIGHT WING FLAP HOLE FOR BEARING ASSEMBLY IS CORRODED. REMOVED CORROSION. INSTALLED REPAIR SLEEVE AND BUSHING PER EA 5750-01796. (M)SDR ASAA0380250Attach Fitting · gougedOKC - FOUND DURING 30K CHECK, LEFT OUTBOARD FLAP HINGE ATTACH LUG IS GOUGED. BLENDED PER ASA EA 5750-01803. (M)SDR ASAA0380249Longeron · corrodedOKC - DURING 30K CHECK, STATION 1015 LONGERON 30 CORROSION AT FASTENER HOLES. SPOT FACED CORROSION PER EA 5310-02158. (M)SDR ASAA0380248Longeron · corrodedOKC - DURING 30K CHECK, FOUND AFT CARGO AREA LONGERON 30 CORRODED ON UNDERSIDE OF FLANGE. REPAIRED LONGERON 30 PER SRM. (M)SDR ASAA0380247Guard · crackedOKC - DURING 30K CHECK, FOUND LEFT MLG SPLASH GUARD CRACKED AT WELD. REPLACED WELDED AREA PER MM PROCEDURES. (M)SDR ASAA0380242Cap · gougedOKC - FOUND DURING 30K CHECK, RIGHT WING LEADING EDGE END CAP GOUGED. BLENDED, PERFORMED WELD REPAIR PER EA 5740-01344. (M)SDR ASAA0380241Shear Tie · corrodedOKC - FOUND DURING 30K CHECK, AFT CARGO AREA HAS CORRODED SHEAR TIE. REPLACED SECTION OF DAMAGED SHEAR TIE PER SRM. (M)SDR ASAA0380224Vane · dentedOKC - DURING 30K CHECK, FOUND RIGHT FLAP VANE DENTED ON LEADING EDGE. REMOVED DAMAGED AREA AND INSTALLED FILLER AND DOUBLER PER SRM. (M)SDR ASAA0380223Vane · dentedOKC - DURING 30K CHECK, FOUND RIGHT INBOARD FLAP VANE DENTS ON INBOARD END. REMOVED DAMAGE AND INSTALLED FILLER AND DOUBLER PER SRM. (M)SDR ASAA0380222Cargo Track · corrodedOKC - DURING 30K CHECK, FOUND AFT CARGO TRACK CORROSION AT FASTENER HOLES. REPLACED DAMAGED TRACK PER SRM. (M)SDR ASAA0380221Frame · damagedOKC - DURING 30K CHECK, FOUND FRAME FLANGE HAS TOOL DAMAGE AT FASTENER HOLES. REPLACED DAMAGED FRAME PER SRM. (M)SDR ASAA0380220Floor Support · crackedOKC - DURING 30K CHECK, FOUND CABIN FLOOR SUPPORT CRACKED. REPLACED DAMAGED CABIN FLOOR SUPPORT PER SRM. (M)SDR ASAA0380238Panel · crackedOKC - DURING 30K CHECK, FOUND RIGHT FUSELGAE AFT PANEL NR 2207 IS CRACKED AT THE FORWARD END. REPAIRED PANEL WITH BONDED FIBERGLASS OVERLAY PER SRM. (M)SDR ASAA0380234Skin · gougedOKC - DURING 30K CHECK, FOUND RUDDER LEADING EDGE UPPER SKIN GOUGED AND CREASED. REMOVED DAMAGED AREA AND INSTALLED REPAIR DOUBLER PER SRM. (M)SDR ASAA0380240Intercostal · crackedOKC - DURING 30K CHECK, FOUND AFT CARGO AREA INTERCOSTAL IS CRACKED. REPLACED INTERCOSTAL PER SRM. (M)SDR ASAA0380239Longeron · corrodedOKC - DURING 30K CHECK, FOUND LONGERON AND 29R AFT OF STATION 579 HAVE CORROSION AROUND FASTENERS. REMOVED DAMAGED DOUBLER. INSTALLED NEW REPAIR DOUBLER AND STRAP PER ASA EA 5330-01195. (M)
Back to Mcdonnell Douglas DC-9-82