Mcdonnell Douglas MD 83

Service difficulty reports · 3,415

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'MD83'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR WX0A2012031371126Frame · damagedHI-LOK TOO CLOSE TO RIVET ON FRAME STA 256 NEAR LONGERON 4R (MISDRILLED). CUT OUT DAMAGED SECTION, FABRICATED REPAIR PLATE, FILLER, LOCATED, DRILLED AND INSTALLED IAW MD80 SRM 53-03 FIG 4.Feb 29, 2012 · N891GA · Doug MD83 · Fuselage Main, FrameSDR WX0A2012031371124Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERFeb 28, 2012 · N893GA · Doug MD83 · Emergency LightingSDR WX0A2012031371122Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AFeb 26, 2012 · N880GA · Doug MD83 · Emergency LightingSDR WX0A2012031371119Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AFeb 26, 2012 · N871GA · Doug MD83 · Emergency LightingSDR WX0A2012031371120Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE AFeb 24, 2012 · N876GA · Doug MD83 · Emergency LightingSDR WX0A2012031371117Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE AFeb 24, 2012 · N405NV · Doug MD83 · Emergency LightingSDR WX0A2012031371121Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERFeb 23, 2012 · N878GA · Doug MD83 · Emergency LightingSDR WX0A2012031371118Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERFeb 23, 2012 · N871GA · Doug MD83 · Emergency LightingSDR WX0A2012021971109Battery · defectiveEMERGENCY EVACUATION LIGHTING SYSTEM FOUND TO BE DEFECTIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERIES IN THE POWER SUPPLY BATTERY PACK. AN OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00, OPS CHECKED NORMAL. AIRCRAFT RETURNED TO SERVICE.Feb 19, 2012 · N869GA · Doug MD83 · Emergency LightingSDR WX0A2012021671116Radome · damagedPOSSIBLE DAMAGE DUE TO BIRD STRIKE IN RADOME, COMPLIED WITH INSPECTION IAW AMM 05-51-08 & TASK CARD 10900513, FOUND RADOME DAMAGE. REMOVED AND REPLACED RADOME IAW AMM 53-51-00. AIRCRAFT RETURNED TO SERVICE.Feb 16, 2012 · N418NV · Doug MD83 · Aerodynamic FairingsSDR WX0A2012021571108Battery · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED THE BATTERIES IN POWER SUPPLY BATTERY PACK, AN OPERATIONAL CHECK WAS ACCOMPLISHEFeb 15, 2012 · N869GA · Doug MD83 · Emergency LightingSDR WX0A2012020971103Light · no testDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED EMERGENCY EXIT LIGHT ASSY, AN OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 33-50-00Feb 9, 2012 · N405NV · Doug MD83 · Emergency LightingSDR WX0A2012020671111Battery · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED THE BATTERIES IN POWER SUPPLY BATTERY PACK. AN OPS CHECK ACCOMPLISHED PER AMM 3Feb 6, 2012 · N875GA · Doug MD83 · Emergency LightingSDR WX0A2012020471104Battery · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED THE BATTERIES IN POWER SUPPLY BATTERY PACK AN OPERATIONAL CHECK WAS ACCOMPLISHED Feb 4, 2012 · N407NV · Doug MD83 · Emergency LightingSDR WX0A2012020371107Battery · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED THE BATTERIES IN THE POWER SUPPLY BATTERY PACK. AN OPERATIONAL CHECK WAS ACCOMPLFeb 3, 2012 · N860GA · Doug MD83 · Emergency LightingSDR WX0A2012020171110Battery · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED THE BATTERIES IN POWER SUPPLY BATTERY PACK. AN OPERATIONAL CHECK WAS ACCOMPLISHEFeb 1, 2012 · N871GA · Doug MD83 · Emergency LightingSDR WX0A2012013071096Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY BATTERY PACK AND OPS CHECK ACCOMPLISHED PER AMM 33-50-00, OPS CHECKEJan 30, 2012 · N872GA · Doug MD83 · Emergency LightingSDR WX0A2012012871095Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED BATTERY PACK IN THE POWER SUPPLY AND OPS CHECK WAS ACCOMPLISHED PER AMM 33-50-0Jan 28, 2012 · N860GA · Doug MD83 · Emergency LightingSDR WX0A2012012871094Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE REMOVED AND REPLACED POWER SUPPLY BATTERY PACK AND OPS CHECK WAS ACCOMPLISHED PER AMM 33-50-00, SYSTEJan 28, 2012 · N421NV · Doug MD83 · Emergency LightingSDR WX0A071085Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY EXIT LIGHT ASSY AND MADE AJan 26, 2012 · N407NV · Doug MD83 · Emergency LightingSDR WX0A071090Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AJan 24, 2012 · N883GA · Doug MD83 · Emergency LightingSDR WX0A071089Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AJan 23, 2012 · N876GA · Doug MD83 · Emergency LightingSDR WX0A071088Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE PORTABLE EMERGENCY EXIT LIGHT ASSY AJan 20, 2012 · N860GA · Doug MD83 · Emergency LightingSDR WX0A071080Control Valve · leakingFLIGHT CREW PERSONNEL REPORTED SMOKE IN THE CABIN AFTER TURNING ON APU AIR AT THE GATE. MAINTENANCE DEPARTMENT PERSONNEL INSPECTED AND FOUND HYD FLUID LEAKING FROM LEFT REVERSER CONTROL VALVE INJESTED INTO APU INLET CAUSING SMOKE IN CABIN THROUGH THE AIR SYSTJan 16, 2012 · N411NV · Doug MD83 · Hydraulic System, MainSDR WX0A071077Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AJan 12, 2012 · N884GA · Doug MD83 · Emergency LightingSDR WX0A071076Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 12, 2012 · N884GA · Doug MD83 · Emergency LightingSDR WX0A071075Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 12, 2012 · N884GA · Doug MD83 · Emergency LightingSDR WX0A071064Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EXTERIOR LIGHT POWER SUPPLY BATTERY Jan 12, 2012 · N863GA · Doug MD83 · Emergency LightingSDR WX0A071073Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 11, 2012 · N880GA · Doug MD83 · Emergency LightingSDR WX0A071069Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 9, 2012 · N875GA · Doug MD83 · Emergency LightingSDR WX0A071067Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AJan 6, 2012 · N871GA · Doug MD83 · Emergency LightingSDR WX0A071072Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AJan 5, 2012 · N880GA · Doug MD83 · Emergency LightingSDR WX0A071079Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK AND MADE AJan 4, 2012 · N893GA · Doug MD83 · Emergency LightingSDR WX0A071070Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 2, 2012 · N876GA · Doug MD83 · Emergency LightingSDR WX0A071071Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 2, 2012 · N876GA · Doug MD83 · Emergency LightingSDR WX0A071068Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 2, 2012 · N875GA · Doug MD83 · Emergency LightingSDR WX0A071066Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 2, 2012 · N864GA · Doug MD83 · Emergency LightingSDR WX0A071065Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERYJan 2, 2012 · N864GA · Doug MD83 · Emergency LightingSDR WX0A071074Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERJan 1, 2012 · N883GA · Doug MD83 · Emergency LightingSDR WX0A071047Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 30, 2011 · N873GA · Doug MD83 · Emergency LightingSDR WX0A071046Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY LUMINESCENT TRACK ASSY ANDDec 29, 2011 · N873GA · Doug MD83 · Emergency LightingSDR WX0A071045Light · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE EMERGENCY LUMINESCENT TRACK ASSY ANDDec 27, 2011 · N873GA · Doug MD83 · Emergency LightingSDR WX0A071051Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 26, 2011 · N876GA · Doug MD83 · Emergency LightingSDR WX0A071048Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 23, 2011 · N875GA · Doug MD83 · Emergency LightingSDR WX0A071041Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 23, 2011 · N415NV · Doug MD83 · Emergency LightingSDR WX0A071050Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 22, 2011 · N876GA · Doug MD83 · Emergency LightingSDR WX0A071049Battery · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 22, 2011 · N876GA · Doug MD83 · Emergency LightingSDR WX0A071037Wire · damagedROW 6 A-C THRU 8 A-C LOWER SIDEWALL LIGHTS INOP. REPAIRED WIRING BEHIND OVERHEAD BIN ROW 7 LEFT IAW SWPM 20-10-01. OPS CHECK NORMAL, AIRCRAFT RETURNED TO SERVICE.Dec 16, 2011 · N872GA · Doug MD83 · Light System WiringSDR WX0A071025Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERDec 15, 2011 · N471NV · Doug MD83 · Emergency LightingSDR WX0A071023Skin · gougedLEFT WING OTBD FLAP INBD VANE L/E GOUGED AT STATION XW 146. REMOVED DAMAGED SKIN, FABRICATED FILLER, DOUBLER AND BONDED IAW MD80 SRM 57-03, FIG 11.Dec 12, 2011 · N879GA · Doug MD83 · Trailing Edge Flaps
Back to Mcdonnell Douglas MD 83