Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026010958729Light · no discrepancyOVERWING EXIT LIGHT INOPERATIVE. PERFORMED EMERGENCY LIGHT OPS TEST IAW AMM 33-51-00. OPS CHKD GOOD. UNABLE TO DUPLICATE FAULT.SDR SWAA2026010958692Battery Pack · inoperativeMULTIPLE EMERGENCY LIGHTS INOPERATIVE. FOUND POWER SUPPLY M1670 WITH BAD FUSE. R&R THE FUSE AND BATTERY PACK IAW AMM 33-51-06. OPS CHKD GOOD.SDR SWAA2026010958413Handle · brokenAFT ENTRY DOOR ASSIT HANDLE BROKEN. REPLACED THE AFT ENTRY DOOR ASSIST HANDLE IAW AMM 52-13-31.SDR DXTA2026010906467Unknown · smokeAFTER APU START WE SMELLED OIL AND SAW SLIGHT SMOKE IN CABIN. AFTER MOTORING ENGINE BEFORE START, SMOKE REAPPEARED A LITTLE MORE DENSE WITH SMELL AGAIN. MCC ELECTED TO PERFORM FINAL RUN WITH SITE REP PERFORMED 3 MIN APU RUN AND 3 MIN EACH IDEL ENGINE RUNS SDR DXTA2026010906468Air Data Module · faultedAT FL360 WE RECEIVED AMBER EFIS MISCOMPARE WITH AMBER ATL. THE RIGHT SIDE READ 200¿ LOWER THAN THE LT & STANDBY. WHEN SELECTING AIR DATA 1 PER THE CHECKLIST. RECEIVED FOLLOWING CYAN FAULTS: FLAPS FAULT, R ENG THRUST FAULT, L ENG THRUST FAULT, STAB TRIM FAUSDR F3LA202601090349Actuator · malfunctionedACFT WAS GROUNDED AS A RESULT OF THIS SDR REPORTABLE EVENT. REFERENCE LP 478558 ITEM #1 FLIGHT 1540. FLT/CTL FLAPS LOCKED ECAM WHEN SELECTING FLAPS 2 IN FLIGHT DURING ARRIVAL. ACFT GROUNDED. PERFORMED TSM 27-51-00-810-A REF LP478559 ITEM #1 FOUND BOTH LH ANDSDR QXEA2026010900007Power Unit · malfunctionedWHILE PERFORMING TASK CARD E175-33-50-01-720-801-A FOUND SIX EMERGENCY LIGHTS WENT OUT BEFORE 15 MINUTES. REPLACED THE ELPU BATTERY IAW AMM 33-50-01-000-802-A AND 33-50-01-400-802-A. LIGHTS WERE ON MORE THEN 15 MINUTES. TEST PASSED.SDR AALA202601093371Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE: R4 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-22-00.SDR AALA202601090019Handle · looseAIRCRAFT WAS NOT GROUNDED: DOOR 2R ARM/DISARM PLACARD ON LEVER IS LOOSE. MAINTENANCE TIGHTENED 2R ARM DISARM HANDLE.SDR AALA202601094987Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT FOR EMERGENCY POWER SUPPLY UNIT 12WL DISPLAYED DURING SYSTEM TEST. MAINTENANCE REPLACED BATTERY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38.SDR AALA202601099546Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: FORWARD RIGHT EMERGENCY EXIT DOOR 843 DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202601098488Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE: L4 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-22-00.SDR AALA202601091712Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: AFT RIGHT PASSENGER / CREW DOOR 842 DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202601092786Handle · looseAIRCRAFT WAS NOT GROUNDED: DOOR 3R ARM/DISARM PLACARD ON LEVER IS LOOSE. MAINTENANCE TIGHTENED 3R ARM DISARM HANDLE.SDR AALA202601095054Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: AFT LEFT EMERGENCY EXIT DOOR 834 DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR DXTA2026010906474Landing Gear · faultedGEAR SELECTION FROM DOWN TO UP IS DIFFICULT TO MOVE GETS STUCK IN POSITION. SAME WHEN SELECTING GEAR FROM UP TO DOWN POSITION. COMMUNICATED WITH ON FIELD MAINTENANCE MANGER FOR APPROVAL TO USE GPU INSIDE HANGAR. PERFORMED ARES DOWNLOAD AND SENT TO TEAM 680A SDR DXTA2026010906458Distribution Box · faultyIN FLIGHT WE GOT A CYAN R PROBE MON FAIL MESSAGE, WHICH THEN TRIGGERED THREE AMBER CAS MESSAGES: R AOA HEAT FAIL, PITOT 2 HT FAIL AND STBY PITOT HT FAIL. THIS ALL BEGAN WHEN THE HBMU 2 CIRCUIT BREAKER TRIPPED ON THE EMS-CDU. T/S SYSTEM, REMOVED SUSPECTED HBSDR DXTA2026010906459Generator · faultyWSHLD HEAT INOP R AMBER CAS MESSAGE POSTED DURING CLIMB OUT. RAN QRH. REPLACED AC GENERATOR SEALS IAW PW306D MM 72-60-01 REMOVED DEFECTIVE AC GEN AND INSTALLED OVERHAULED AC GENERATOR IAW CE680A MM 24-20-05 POST-MAINTENANCE CHECKS AND WINDSHIELD FUNCTIONAL CSDR CALA2026010912852Anti-Ice Valve · failedANTI ICE ENG L EICAS, LT ENG ANTI ICE VALVE DEACTIVATED IN OPEN POSITION WITH KIT WAITING FOR DEFERRAL. APPROVES MEL 3021T LT EAI VALVE DEACTIVATED OPEN WITH KIT DEFERRED EAI VALVE DEACTIVATED IN OPEN POSITION IAW AMM 30-00-00-040-809-001.SDR CALA2026010912837Pump · failedENGINE 1 SYS A HYD PRESSURE LIGHT ILLUMINATED. FOUND NR 1 ENG DRIVEN HYDRAULIC PUMP TO HAVE COMPLETE MECHANICAL FAILURE. REMOVED ENG 1 EDP IAW AMM 29-11-11-000-801-001. UP TO AND INCLUDING STEPS F. (10) (B). INSTALLED AND COMPLETED UP TO AND INCLUDING STEPSSDR CALA2026010912835Fuel Cap · missingFUEL CAP FOUND MISSING ITEM CREATED TO ACCOUNT PDA FUEL CAP CURRENTLY ON CDL REPLACED FUEL CAP IAW AMM 28-25-41-400-007-A.SDR DALA2026010900196Plug · disconnectedCAPTAIN'S OXYGEN MASK MICROPHONE INOPERATIVE. RECONNECTED MIC PLUG INSIDE O2 BOX. OPS CHECK GOOD. A/C OK FOR SERVICE. (LP: 8079624)SDR DALA2026010900195Switch · out of positionUPON INSTALLATION OF SLIDE ON STEP 13, OPERATIONAL TEST FAILED, ABORTED. R & R CAM PANEL AND PTP PANEL PERFORMED OPS TEST STILL SAYS TEST ABORTED. INSTALLED IAW AMM 23-73 NEEDS FURTHUR T/S. CONFIGURED COCKPIT SWITCHES PER TEST AND THE TEST PASSED IAW AMM SDR DALA2026010900208Plate · bentON DRAG UP SUPER TUG REPORTED L1 DOOR UPPER COVER PLATE BENT. INSPECTED L1 DOOR UPPER COVER PLATE IAW SRM 52-10-00-283 DIST EXTENDS BEYOND LIMITS. REWORRKED MINOR DAMAGE IAW SRM 51-73-00-801 OK FOR SVC. (LP: 7747095)SDR DALA2026010900205Support Angle · crackedCRACK SUPPORT ANGLE, HINGE ARM 1 ELEVATOR ON LT HORIZONTAL STAB. REPLACED SUPPORT ANGLE ON HINGE ARM 1 ELEVATOR IAW SRM 51-42-11, SRM 51-72- 11, DWG D55182701, ISSUE W, AMM 55-16-42-000-001-A, AND AMM 55-16-42-400-001-A, MEASUREMENT OF CRACK WAS 0.408IN.SDR DALA2026010900202Dummy Rail · corrodedCORROSION RAIL DUMMY Y503.2 AT FWD GALLEY AREA. REPLACED RAIL DUMMY Y503.2 FR12 TO FR16 LH AND FASTENERS AT FWD GALLEY AREA AS PER A319 SRM 51-72-11 AND DWG D53112825 AND DWG D53110984. TOOK MEASURES OF CORROSION ARE L:1.562 IN W:1.375 IN D:0.060 IN. (LP: 1SDR DALA2026010900201Seat Track · corrodedCORROSION SEAT TRACK -Y765 LOC. FR 20. REPLACED THE SEAT TRACK IAW SRM 51-42-11, SRM 51-72-11, DWG D53110984, ISSUE: C00, DWG D53110920, ISSUE: E00, AND DWG D53112812, ISSUE: E00, MEASUREMENT OF CORROSION: L= 2.790 IN W=1.198 IN D=0.061 IN. (LP: 1389294)SDR DALA2026010900200Floor Support · corrodedCORROSION FLOOR SUPPORT -Y1292, FR 18 - 20. REPLACED THE FLOOR SUPPORT AND FASTENERS IAW SRM 51-42-11, SRM 51-72-11 , DWG D53110984, DWG D53110920, DWG D53112812. AND IAW ESPM 20-33-41. MEASUREMENT OF CORROSION: P.1 L= 1.184 IN W= 0.787 IN D= 0.026 IN P.2 LSDR DALA2026010900199Seat Track · corrodedCORRODED SEAT TRACK +Y765 AT FR66. REPLACED THE SEAT TRACK AND FASTENERS IAW SRM 51-42-11, SRM 51-72 -11, AND DWG 10N01048, ISSUE: F. MEASUREMENT OF CORROSION: L= 2.187 INCHES, W= 0.504 INCHES, D= 0.032 INCHES. (LP: 1389196)SDR DALA2026010900198Seat Track · corrodedCORROSION SEAT TRACK +Y1162.5 LOC. FR 68 TO FR 69 LH SIDE AT AFT GAL LEY AREA. REPLACED SEAT TRACK IAW SRM 51-42-11, SRM 51-72 11, AND DWG: D53474180, ISSUE AA, DWG: D53472780, ISSUE K, DWG: D53474250, ISSUE V, DWG: D53472088, ISSUE H, AND DWG D53478309, ISSSDR DALA2026010900197Shear Web · corrodedAFT FUSELAGE INTERNAL FLOOR STRUCTURE BETWEEN FR 69 AND FR 70 AT STGR 23R, WEB WITH CORROSION. REPLACED SHEAR PLATE IAW SRM 53-41 -17-01A, FIGURE 001, ITEM 310-A REV 155 AND INSTALLED IAW DWG D534 74180, ISSUE U, SHEET 6. (LP: 1388591)SDR SCNA20260109018Guard · brokenEMERHENCY EXIT LIGHT SWITCH ON P5 PANEL BLACK GUARD BROKEN. SWITCH IS NOT CLOSING, PART NUMBER NOT ASSIGNED TO THIS ACFT. IPC SAYS IT IS. INSTALLED PART NUMBER B9985-1.SDR CALA2026010812808Computer · faultedFEEL DIFF PRESS LIGHT LIGHT ON FEEL DIFF LIGHT ON INFLIGHT WHEN PITCH CHANGES LOCKED LP DUE TO HISTORY. UNLOCKED BY TOMC PERFORMED FIM 27-31 TASK 815. FROM "FAULT ISOLATION PROCEDURE C" (STEP H) TO H(4). ALL CHECKS PASS, NO LEAKS. DUE TO PREVIOUS WRITE UP THATSDR CALA2026010812807Governor · faultedRIGHT ENGINE WOULD NOT GO TO TAKEOFF THRUST WITH AUTO THROTTLE ENGAGED, REMOVED NR 2 ENGINE (PHASE 2) FUEL FLOW GOVERNOR MFG PART NR 8062-551 IAW AMM 73-21-01-004-001-R04. PREPPING INSTALLATION OF NEW FFG WITH SAME MFG PART NR 8062-551 REF IPC 73-21-01-01. QCSDR CALA2026010812791Lens · brokenEMERGENCY LIGHTS OPERATIONAL CHECK, ROW 11, SEAT C, PROXIMITY LIGHT NEEDS TO BE SECURED OR REPLACED. REPLACED BROKEN LENS CAP AND SECURED. OPS CKD OK.SDR CALA2026010712790Lamp · inoperativeROW 20 ABC. AFT RED EMERGENCY PATH LIGHT IS INOPERATIVE. RELAMPED FLOOR PROXIMITY LIGHT PER AMM TASK 33-51-11-960-802. SYSTEM TESTED GOOD.SDR AALA202601080598Door · stickingAIRCRAFT WAS NOT GROUNDED: LAVATORY-D GETS STUCK IN CLOSED POSITION. (OPEN).SDR AALA202601088647Girt Bar · out of adjustAIRCRAFT WAS NOT GROUNDED: L4 DOOR EMERGENCY SLIDE GIRT BAR DIFFICULT TO LOCK IN PLACE. ADJUSTED L4 DOOR GIRT BAR SLIDE. PER AMM 25-66-00-0.SDR AALA202601083566Bracket · out of adjustAIRCRAFT WAS NOT GROUNDED: FORWARD SERVICE DOOR GIRT BAR BRACKET LOOSE. ADJUSTED GIRT BAR BRACKET. PER AMM 25-66-02.SDR SWAA2026010859138Engine · damagedAFTER TAKE OFF AT ABOUT 800 FEET BIRD STRIKE NR 1 ENGINE SMELLED IN THE CABIN / FLIGHT DECK. NR 1 ENGINE 100 DEGREES HOTTER, REF LOG PAGE 2953324 FOR ACCOMPLISHMENT OF BIRD STRIKE CONDITIONAL INSPECTION. PERFORMED MT 772-00-00, BIRD STRIKE VISUAL INSPECTION SDR DALA2026010800190Trigger · stuckDECLARED AN EMERGENCY AND PERFORMED A GO AROUND INTO BHM DUE TO LANDING GEAR DISAGREE INDICATION. FOUND GEAR RELEASE TRIGGER STUCK FULL AFT. CLEANED TRIGGER MECHANISM AND RESET. SUBSEQUENTLY REPLACED GEAR HANDLE MODULE. OPS NORMAL. (LP 7945232, 1389060)SDR SWIA202601080006Skin · damagedDURING LIGHTNING STRIKE INSPECTION FOUND 1 BURNED RIVET ON FR24 1ST RIVET BELOW STR22L. BURN DAMAGE IS 3/8 L X 3/8 W X 0.073 D AND OUT OF LIMITS PER SRM 53-00-00 REPAIR 03.DAMAGE IS OUT OF LIMITS AND THE STRUCTURALLY SIGNIFICANT ITEM IS CLISSIFIED AS A MAJOR RSDR GTIA2026010839242Fan · inoperativeSMOKE IN COCKPIT STARTING N 25,000-PERFORMED TSM 05-50-00-810-831-A. AIRCRAFT CATEGORIZED AS TYPE 9 AQE. TROUBLESHOT AND FOUND L RECIRC FAN 15HG CAUSE OF AQE BURNING ELECTRICAL ODOR IAW TSM TSM 05-50-00-810-831-A AND AMM 21-21-51. SEE LP 6004369-2 FOR LT RECIRSDR GTIA2026010839241Unknown · odorSMELLED ODOR ON TAKE OFF AND LANDING -FOUND EVIDENCE OF HYDRAULIC FLUID LEAKING FROM YELLOW SYSTEM HP MANIFOLD BAY INTO APU AIR INLET. REPLACED PACKINGS ON YELLOW SYSTEM HP MANIFOLD IAW AMM 29-13-14. OPS/LEAK CHECK GOOD. PERFORMED DECONTAMINATION OF ECS SYSTEMSDR DALA2026010800162Skin · damagedPREVIOUSLY ACCOMPLISHED FUSELAGE SKIN REPAIR FS 760 - 780 BETWEEN STR 14L - 16L FASTENERS DRILLED INTO CHEM MILL EDGE. AREA WAS INSPECTED ON AMDS 2020-2466. CORRECTIVE ACTION: REMOVED AND INSTALLED NEW REPAIR AT STA 760-780 BETWEEN STR 14L- 16L IAW B757-200 SRSDR GTIA2026010839240Battery · inoperativeAFT FA FLASHLIGHT INOPERATIVE. R & R FA FLASHLIGHT BATTERY IAW CMM 25-60-13SDR AALA202601085541Bottle · reads lowAIRCRAFT WAS NOT GROUNDED: R1 DOOR EMERGENCY CYLINDER/ACCUMULATOR REQUIRE SERVICING. MAINTENANCE SERVICED R1 DOOR EMERGENCY CYLINDER/ACCUMULATOR PER AMM 52-10-00.SDR AALA202601084827Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L2 DOOR EMERGENCY CYLINDER/ACCUMULATOR REQUIRE SERVICING. MAINTENANCE SERVICED L2 DOOR EMERGENCY CYLINDER/ACCUMULATOR PER AMM 52-10-00.SDR AALA202601088358Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L1 DOOR EMERGENCY CYLINDER/ACCUMULATOR REQUIRE SERVICING. MAINTENANCE SERVICED L1 DOOR EMERGENCY CYLINDER/ACCUMULATOR PER AMM 52-10-00.SDR F3LA202601080347Actuator · faultedACFT WAS GROUNDED AS A RESULT OF THIS SDR REPORTABLE EVENT.REF LP 478558 ITEM #1. FLT/CTL FLAPS LOCKED ECAM WHEN SELECTING FLAPS 2 IN FLIGHT DURING ARRIVAL. ACFT GROUNDED. PERFORMED TSM 27-51-00-810-A REF LP478559 #1 FOUND BOTH LH AND RH #1 FLAP ACTUATORS FU