Service difficulty reports
1,770,704 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026102119544Support Angle · crackedCRACKED SUPPORT ANGLE FOR RT WING ACCESS PANEL 651FB. REPLACED THE SUPPORT ANGLE IAW SRM 51-40-02, SRM 51-20-01, & DWG 115A2710, SHT 9, REV A.SDR SWAA2026102132055Support Angle · crackedCRACKED SUPPORT ANGLE, BS 500I, STRINGER 28R. REPLACED THE SUPPORT ANGLE & FASTENERS IAW SRM-51-40-02-0G-0, & DWG 143A7902, SHT 320, REV-.SDR AALA202610211333Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON UPPER FLANGE OF INTERCOSTAL STATION 986.5-1006 AT STATION 993.5 RIGHT BUTT LINE 32.5. MAINTENANCE INSTALLED THE INTERCOSTAL AT RIGHT BUTT LINE 32 STATION 986.5-1006 PER AARD 51-00-05-1 AND BOEING DRAWING 147A5700 SHEESDR SIMA20260918010Floor Support · corrodedAFT WET AREA FLOOR STRUCTURE - CORROSION ON BEAM AS MARKED FR 87 Y+11". (MAJOR REPAIR) (LEVEL 2 CORROSION) REMOVED AND REPLACED WITH NEW FLOOR STRUCTURE BEAM AT FR 87 Y+11" IAW EMB 175 SRM 51-40-08.SDR SIMA20260918011Seat Track · corrodedAFT WET AREA FLOOR STRUCTURE - CORROSION ON SEAT TRACK FR 84-85 Y-11". (MAJOR REPAIR) (LEVEL 2 CORROSION) PERFORMED CUTOUT WITH A FILLER AND DOUBLER REPAIR OF THE SEAT TRACK AT FR 84-85 Y-11" IAW SRM 53-23--10/REPAIR 01P AND NCR-EJ-53-228.SDR SWAA2026101948336Floor Panel · delaminatedFLOOR PANEL 241FF, UPPER SURFACE WAS DELAMINATED, OTBD CORNER 241FF. THE FLOOR PANEL WAS REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 8.A.1.SDR SWAA2026101968418Floor Panel · delaminated242DF FLOOR PANEL UPPER SURFACE WAS DELAMINATED, OTBD CORNER 242DF FLOOR PANEL UPPER SURFACE OTBD CORNER. REPLACED WITH A SERVICEABLE FLOOR PANEL IAW SRM 51-10-02-0G-0, PARA 8.A.1.SDR SIMA20260918003Floor Support · corrodedAFT WET AREA FLOOR STRUCTURE, CORROSION ON INTERCOSTAL . REMOVED AND REPLACED WITH NEW INTERCOSTAL AT FR 89-90Y+11" IAW EMB 175 SRM 51-40-08SDR SIMA20260918009Floor Support · corrodedAFT WET AREA FLOOR STRUCTURE - CORROSION ON PANEL SUPPORT, FR 84 Y+44"(LEVEL 2 CORROSION). REMOVED AND REPLACED WITH NEW FLOOR STRUCTURE PANEL SUPPORT AT FR 84 Y+44" IAW SRM 51-40-08.SDR SIMA20260918008Floorbeam · corrodedAFT WET AREA FLOOR STRUCTURE - CORROSION ON SPLICE FR 90 Y-11" AND Y-7" (LEVEL 2 CORROSION). REMOVED AND REPLACED SPLICE WITH NEW FROM STOCK PART ON AFT WET AREA FR 90 Y-11" AND Y-7" PER SRM 51-40-08.SDR SIMA20260918005Gusset · corrodedSSI# 53-23-005 AFT WET AREA FLOOR STRUCTURE - CORROSION ON SPLICE, FR 90 Y+24" (LEVEL 2 CORROSION). REMOVED AND REPLACED WITH NEW FLOOR STRUCTURE SPLICE AT FR 90 Y+24" IAW SRM 51-40-08SDR SIMA20260918007Shear Panel · corrodedAFT WET AREA FLOOR STRUCTURE. CORROSION ON SHEAR PANEL FR 87-88 Y+40" (LEVEL 2 CORROSION). REMOVED AND REPLACED WITH NEW SHEAR PANEL AT FR 87-88 Y+40" IAW EMB 175 SRM 51-40-08SDR SIMA20260918004Gusset · corrodedAFT WET AREA FLOOR STRUCTURE, CORROSION ON SPLICE FR 90 Y-11" (LEVEL 2 CORROSION). REMOVED AND REPLACED WITH NEW AFT WET AREA SPLICE AS MARKED AT FR 90 Y-11" IAW EMB 175 SRM 51-40-08.SDR SIMA20260918006Floor Support · corrodedAFT WET AREA FLOOR STRUCTURE - CORROSION ON SPLICE FR 89 Y+11" (LEVEL 2 CORROSION) REMOVED AND REPLACED WITH NEW SPLICE AS MARKED AT FR 89 Y+11" IAW EMB 175 SRM 51-40-08SDR REXA2026101601945Drag Angle · crackedDURING (ET) HFEC INSPECTION ON DRAG ANGLE IAW NRC 252, A CRACK WAS FOUND ON THE AFT DRAG ANGLE BTW 55.62% STR DATUM TO 61.56% STGR DATUM (LT SIDE) AT VERTICAL STABILIZER TO FUSELAGE. THE AFT DRAG ANGLE WAS REPAIRED IAW SRM 55-31-00-201-001-A01.SDR REXA2026101601944Drag Angle · crackedCRACKED FWD DRAG ANGLE BTW 55.62% STR DATUM TO 61.56% STGR DATUM (LT SIDE) ON THE VERTICAL STABILIZER TO FUSELAGE. THE FWD DRAG ANGLE WAS REPAIRED IAW SRM 55-31-00-201-001-A01.SDR REXA2026101601943Drag Angle · crackedCRACKED AFT DRAG ANGLE BTWN 55.62% STR DATUM TO 61.56% STR DATUM ON THE VERTICAL STABILIZER TO FUSELAGE. THE AFT DRAG ANGLE WAS REPAIRED IAW SRM 55-31-00-201-001-A01.SDR IPXA2026101613332Panel · delaminatedMAJOR REPAIR, LOWER AFT APU PANEL BETWEEN BS 1963 TO 1992 IS DELAMINATED VERIFIED STEP 14 IS ACCOMPLISHED AND HEAT CON. TAP TEST. NO DISBONDS OR DELAMINATIONS NOTED. OKAY TO TREAT AND PRIME. REF GMM RII 04-02.SDR AALA202610148074Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORRODED INTERCOSTAL. REMOVAL AND REPLACEMENT INTERCOSTAL IAW BOEING DRAWING 147A5650 AND AARD 51-00-05-1.SDR SWAA2026101214235Access Panel · damagedELONGATED HOLES ON RT WING ACCESS PANEL 661BB. REPAIRED ACCESS PANEL 661BB IAW SRM 51-70-04-2R-10, REPAIR 10.SDR SWAA2026101210727Access Panel · elongatedELONGATED HOLES ON LT WING ACCESS PANEL 561CB TRAILING EDGE. REPAIRED THE ACCESS PANEL IAW SRM 51-70-04-2R-10, REPAIR 10.SDR SWAA2026101250031Access Panel · damagedELONGATED HOLES OF ACCESS PANEL 561AB ON LT WING. REPAIRED THE ACCESS PANEL IAW SRM 51-70-04-2R-9 REPAIR 9.SDR SWAA2026101213584Access Panel · damagedELONGATED HOLES ON ACCESS PANEL 661AB AT RT WING. REPAIRED THE ACCESS PANEL IAW SRM 51-70-04-2R-9, REPAIR 9.SDR SWAA2026101227866Access Panel · damagedELONGATED HOLES ON RT WING ACCESS PANEL 661CB. REPAIRED THE ACCESS PANEL IAW SRM 51-70-04-2R-9, REPAIR 9.SDR SWAA2026101233454Access Panel · damagedELONGATED HOLES ON ACCESS PANEL 561BB AT LT WING. REPAIRED ACCESS PANEL 561BB AT LT WING IAW SRM 51-70-04-2R-9, REPAIR 9.SDR CALA2026101220283Skin · crackedLEFT HORIZONTAL STAB LOWER SKIN, ONE CRACK SIGNAL NOTED AT HSS 129.50, INBD SIDE LOCATED TO 9.750 INCH APROX. FWD FROM AFT SPAR. CRACK LENGTH 0.750 INCH. PERFORMED REPAIR TO THE LT HORIZONTAL STAB LOWER SKIN IAW SRM 55-10-01-2R-11.SDR CALA2026101220280Gusset · crackedFRAME 66, STRINGER 14R, GUSSET PLATE MIDDLE HOLE IS VISIBLY ELONGATED IN GUSSET PLATE LAYER. THE GUSSET PLATE WAS R & R IAW SRM 53-41-12-300-018, FIGURE 1.SDR AALA202610093115Floorboard · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 231YF SHOWS SIGNS OF DELAMINATION. RECEIVED NEW MAIN CABIN FLOOR PANEL 231YF PN EBF1222-501 PER B737-NG-AIPC 53-21-00-42A.SDR AALA202610099372Floorboard · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241EF SHOWS SIGNS OF DELAMINATION. RECEIVED NEW MAIN CABIN FLOOR PANEL 241EF PN 144A5810-129 PER B737-NG-AIPC 53-21-00-42A.SDR AALA202610093866Angle · crackedAIRCRAFT IN BASE MAINTENANCE: LT CREASE ANGLE CRACKED AT STA 303 LBL 56. REMOVED AND REPLACED CREASE ANGLE IAW AARD 51-00-05 AND BOEING DWG# 141A8110 SHEET 8.SDR R61A2026100900300Stringer · corrodedCENTER FUSELAGE 3 STINGER20R HAS CORROSION AROUND 2 RIVET HEAD AT FRAME 88-89. PERFORMED PERMANENT REINFORCING REPAIR REF. ETD2026-170-016500 REV. BSDR R61A2026100900299Stringer · corrodedCENTER FUSELAGE 3 STINGER21R HAS CORROSION AROUND RIVET HEAD AT FRAME 89-90.PERFORMED PERMANENT REINFORCING REPAIR REF. ETD2026-170-016499 REV. BSDR R61A2026100900298Stringer · corrodedCENTER FUSELAGE 3 STINGER23R HAS CORROSION AROUND RIVET HEAD AT FRAME 89-90.PERFORMED PERMANENT REINFORCING REPAIR AT CENTER FUSELAGE 3 STINGER 23R FRAME 89-90 REF. ETD2026-170-016498 REV. CSDR R61A2026100900297Stringer · corrodedCENTER FUSELAGE 3 STINGER23L HAS CORROSION AROUND RIVET HEAD AT FRAME 89-90.REMOVED SECTION OF STRINGER 23L FR83-F90 IAW ETD2026-170-016497 AND REPLACED SECTION OF STRINGERS 23L FR83-FR90 IAW SRIIM TASK ETD2026-016497SDR SWAA2026100509439Skin · damagedAPU COWL DOOR CUTOUT SKIN AT AFT HINGE IS DAMAGED. REPAIRED APU COWL DOOR CUTOUT SKIN AT AFT HINGE IAW SRM 53-80-01-2R-1.SDR AALA202610057121Floor Panel · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK ON ACCESS PANEL 162BF AT AFT CARGO COMPARTMENT. REPAIRED ACCESS PANEL 162BF AT AFT CARGO COMPARTMENT IAW SRM 53-00-50-2R, PROCEDURE 1, REPAIR 1.SDR MASA20261001225Door · corrodedDURING HEAVY CHECK, CFLLL, INSPECTIONS OF AFT EXTERNAL SKIN, CORRODED WASTE ACCESS DOOR BETWEEN FR 88 & 89, STR 25R, EXTERNAL, R & R WITH NEW, IAW AMM 20-10-01. TABLE 202. NRG 4502700-8000-004, REV 103.SDR AALA202610013678Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241SF SHOWS SIGNS OF DELAMINATION. REMOVED AND REPLACED MAIN CABIN FLOOR PANEL 241SF IAW AMM 53-21-00.SDR AALA202610019242Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241LF SHOWS SIGNS OF DELAMINATION. REMOVED AND REPLACED MAIN CABIN FLOOR PANEL 241LF IAW AMM 53-21-00.SDR AALA202610010654Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 242PF SHOWS SIGNS OF DELAMINATION. REMOVED AND REPLACED MAIN CABIN FLOOR PANEL 242PF IAW AMM 53-21-00.SDR AALA202610017448Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241UF SHOWS SIGNS OF DELAMINATION. REMOVED AND REPLACED MAIN CABIN FLOOR PANEL 241UF IAW AMM 53-21-00.SDR AALA202609300271Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241GF SHOWS SIGNS OF DELAMINATION. REMOVED AND REPLACED MAIN CABIN FLOOR PANEL 241GF IAW B-737 NG AMM 53-21-00.SDR AALA202609302376Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 241BF SHOWS SIGNS OF DELAMINATION. INSTALLED NEW MAIN CABIN FLOOR PANEL IAW B737-NG-AIPC 53-21-00-42A.SDR SWAA2026092992719Access Panel · damagedRIGHT STABILIZER ACCESS PANEL 344EB, HAD ELONGATED HOLES & DAMAGE. THE ACCESS PANEL 344EB WAS REPLACED IAW AMM 27-31-11.SDR SWAA2026092980670Access Panel · damagedRIGHT HORIZONTAL STAB ACCESS PANEL 344BB HAD ELONGATED HOLES & DAMAGE. REPLACED THE ACCESS PANEL IAW SRM 51-10-02.SDR SWAA2026092973622Access Panel · elongatedACCESS PANEL 344FB, RT STABILIZER HAD ELONGATED HOLES & DAMAGE. REPLACED THE PANEL 344FB IAW AMM 27-31-11. C/W STEPS 2-6.SDR SWAA2026092933747Access Panel · damagedPANEL 344AT, RT STABILIZER HAD ELONGATED HOLES & DAMAGE. THE PANEL 344AT WAS REPLACED IAW AMM 27-31-11. C/W STEPS 3-7.SDR SWAA2026092956055Panel · damagedPANEL 344DB, ON THE RT STABILIZER HAD ELONGATED HOLES & DAMAGE. PANEL 344DB WAS REPLACED IAW AMM 27-31-11. C/W STEPS 2-6.SDR SWAA2026092955969Panel · damagedPANEL 344AB, RT STABILIZER HAD ELONGATED HOLES & DAMAGE. THE PANEL WAS REPLACED IAW AMM 27-31-11. C/W STEPS 2-6 REF. TTG8Q01E2EPQ OPERATIONAL TESTS ACCOMPLISHMENT.SDR CALA2026092819931Angle · corrodedAPU BAY L/H CUTOUT FWD TWO BRACKETS WITH CORROSION. REMOVED AND REPLACED APU BAY LT CUTOUT ANGLE IAW SRM 51-40-02-0G -0 PAR. 4 AND 7 AND DWG 148A8600, REV A.