Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DXTA2025100705214G Switch · trippedREAR EMERGENCY LIGHTS WILL NOT SHUT OFF CORRECTIVE ACTION: VERIFIED DISCREPANCY. GAINED ACCESS TO #4 EMER BATTERY G-SWITCH. RESET G-SWITCH AND LIGHTS WENT OUT IMMEDIATELY. CHARGED BATTERIES PER TC-FLT-33-1001 EMERGENCY BATTERY TASK CARD. PERFORMED OPS CHECK ANSDR DXTA2025100705217Battery Pack · inoperativeEMERGENCY LIGHTS FAILED FIRST FLIGHT CHECK. BATTERIES OFF, EMER LTS IN ARM; NO EMERGENCY LIGHTE TURNED ON. WHEN SELECTOR PLACED TO ON HALF OF THE REQUIRED LIGHTS CAME ON. CORRECTIVE ACTION: TECHS ARRIVED TO AIRCRAFT AND FOUND THE OUTSIDE WING LIGHT INOP AND THSDR AALA202510079021Door · jammedAIRCRAFT WAS NOT GROUNDED: THE FLIGHT DECK DOOR IS JAMMED CLOSED AND WILL NOT OPEN. CYCLE ON AND OFF AIRCRAFT POWER. DOOR OPENED. OPERATIONAL CHECK NORMAL.SDR AALA202510076568Door · out of adjustAIRCRAFT WAS NOT GROUNDED: LAVATORY-D DOOR LOCK IS HARD TO OPERATE. REMOVED BI-FOLD DOOR OFF LAVATORY-D AND TIGHTEN BOTTOM MOLDING ON BI-FOLD DOOR. REINSTALLED BI-FOLD DOOR AND ADJUSTED DOOR TO HINGES. PER AMM 25-40-14. DOOR CLOSES SMOOTHLY ON ITS OWN, OPERATISDR AALA202510078673Door · jammedAIRCRAFT WAS NOT GROUNDED: LAVATORY-D DOOR JAMMED CLOSED. LUBED LAVATORY-D DOOR TRACK. OPERATIONAL CHECK GOOD.SDR AALA202510074870Door · looseAIRCRAFT WAS NOT GROUNDED: LAVATORY DOOR IS DIFFICULT TO OPEN AND CLOSE. TIGHTENED FORWARD LAVATORY DOOR HANDLE. PER 52-99-00.SDR AALA202510073467Sign · dislodgedAIRCRAFT WAS NOT GROUNDED: EXIT SIGN ON THE LEFT SIDE OF THE AFT GALLEY DISLODGE. RESECURED EXIT SIGN. PER AMM 25-00-00.SDR DALA2025100707295Bracket · damagedSHIP 3360 BRACKET ON FORWARD SIDE AT FRAME 37.1 HAS TOOLING DAMAGE. CORRECTIVE ACTION: REPAIRED PER ERA 627851-14 REV. ORIG. (1237970)SDR DALA2025100707284Seal · leakingAIRCRAFT 5047, AFT FA'S REPORT "DIRTY SOCK" ODOR STARTED APPROX 5 MIN BEFORE LANDING AND STAYED CONSTANT UNTI LEFT ENGINE SHUT DOWN AT GATE WHEN IT STARTED TO DISSIPATE. SMELL WAS CONCENTRATED IN AFT GALLEY. NO SMELL NOTED BY PILOT. REPLACED ENG 2 FRONT SEALSDR AALA202510079729Power Supply · no testAIRCRAFT IN BASE MAINTENANCE: DOOR 5R FWD BATTERY PACK FAILED 15 MIN TEST R+R EMERGENCY LIGHTING BATTERY PACK AT DOOR 5R FWD IAW AMM 33-51-06. OP CHK GOOD.SDR AALA202510072788Power Supply · no testAIRCRAFT WAS NOT GROUNDED: DOOR 5R AFT BATTERY PACK FAILED 15 MIN TEST. MAINTENANCE REPLACED EMERGENCY LIGHTING BATTERY PACK AT DOOR 5R AFT IAW AMM 33-51-06.SDR AALA202510077723Slide · dislodgedAIRCRAFT WAS NOT GROUNDED: FA REPORTS 1L DOOR DOES NOT CLOSE SMOOTHLY AND IS DIFFICULT TO ARM. MAINTENANCE FOUND SLIDE MATERIAL ATTACHED TO GIRT BAR FOLD TOUCHING A/C FLOOR. FIXED FOLD AND OPS CK 1L DOOR IAW AMM 52-10-00.SDR AALA202510070246Cover · out of alignmentAIRCRAFT WAS GROUNDED: DOOR-L EMERGENCY EXIT ECAM ON CLIMB OUT. ASSOCIATED SLIDE ARM LIGHT ON EXIT DOOR. FOUND LT OVERWING SLIDE COVER FLAP PANEL NOT POSITIONED CORRECTLY. MAINTENANCE RESECURED LT OVERWING HATCH COVER FLAP PANEL. REFERENCED AMM52-21-11. ECAM ASDR AALA202510073582Diaphragm · leakingAIRCRAFT WAS GROUNDED: SEE MIC 1579853 & 1580595, CONTINUE REPLACEMENT OF R1 DOOR ASSIST CYLINDER DIAPGHRAGM STARTING AT STEP 4.B(15). REPLACEMENT OF DIAPHRAGM IN R1 DOOR ASSIST BOTTLE PREVIOUSLY ACCOMPLISHED AND SIGNED FOR, REFERENCE JOB CARD 26L00025010 STEPSDR FDEA202510061904Bottle · low pressureR1 DOOR EMERGENCY DAMPENER BELOW MIN NITROGEN CHARGE. AMM 52-10-14-03-02 SERVICED R1 DOOR EMERGENCY DAMPENER CYLINDER TO WITHIN LIMITS PER PLACARD AND AMM 52-10-14-03-02 STEP 3.D.(12) OKAY TO CONTINUE.SDR DALA2025100707281Door Frame · crackedSHIP 3151 CRACK FOUND AT FASTENER HOLES NR 7, A AND C, UPPER FUSELAGE, FRAME 16LT, DOUBLE JOGGLE AREA. COMPLIED WITH ER/A 628831-14AD. (1238454).SDR DALA2025100707280Door Frame · crackedFOUND CRACK AT FASTENER HOLES NR 7, A, C ON UPPER FUSELAGE, FRME 16LT, DOUBLE JOGGLE AREA. COMPLIED WITH ER/A 628831-14AD. (1238446).SDR DALA2025100707278Rod · corrodedCORROSION ON ACTUATING ROD OF FLAP INTERCONNECTING STRUT LH WING. REMOVED INTERCONNECTING STRUT LH WING IAW AMDS CARD 2750-1010-LT. (1237667).SDR DALA2025100707277Rod · corrodedCORROSION ON ACTUATING ROD OF FLAP INTERCONNECTING STRUT RT WING. REMOVED INTERCONNECTING STRUT RH WING IAW AMDS CARD 2750-1010-RT. (1237680).SDR DALA2025100707276Access Door · dentedFOUND DENT ON THE APU ACCESS DOOR LT SIDE OUTER SKIN. COMPLIED WITH ER/A 622362-14. (1237925).SDR QMLA2025100720100Blade · crackedCRACKED TAIL ROTOR BLADE, REPLACED TR HUB AND BLADE ASSY.SDR CALA2025100709748Shroud · brokenSEAT 26C HAS WIRES HANGING LOOSE FOUND EMERGENCY PATH LIGHT COVER HANGING, NO DAMAGE TO WIRES. REPLACED COVER FOR 26C AISLE PATH EMERGENCY LIGHT, AND VERIFIED EMERGENCY LIGHT OPS CHKS GOOD AT 26C.SDR CALA2025100709747Light · no testOPERATIONAL TEST - EMERGENCY ESCAPE PATH LIGHTING (EEL) SYSTEM PERFORM OPERATIONAL CHECK. CROSS AISLE EMERGENCY LIGHT ABOVE 23K INOP REMOVED AND REPLACED CROSS AISLE EMERGENCY LIGHT ABOVE SEAT 23K AND OPS CHECKED, GOOD AS PER AMM 33-51-05/201.SDR CALA2025100709746Battery Pack · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. EMERGENCY AISLE LIGHT NEAR SEAT 23 FED IS INOP. R & R BATTERY PACK, RIGHT AFT OVERWING SLIDE EMERGENCY LIGHT LAMP REPLACED, OPS CK GOOD, REF AMM TASK 33-51-04-960-801.SDR CALA2025100709745Battery Pack · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - EMERGENCY AISLE LIGHT NEAR SEAT 27 FED IS INOP. R & R BATTERY PACK, REMOVED AND REPLACED EMERGENCY AISLE LIGHT ASSY, REF AMM 33-51-03. OPS CK GOOD.SDR CALA2025100709744Power Supply · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. AFT RIGHT EMERGENCY SLIDE OVERWING LIGHT IS INOP. REMOVED & REPLACED EMERGANCY BATTERY AND POWER SUPPLY FOR M1671 REF AMM 33-51-06/201. OPS CHECK GOOD.SDR CALA2025100709743Battery Pack · inoperativeWHILE PERFORMING EPSU BITE REF AMM 33-51-00-710-001-A, RECIEVED A EPSU EMER R BATTERY MESSAGE REMOVED AND REPLACED THE RIGHT EMERGENCY EXIT EPSU BATTERY REF AMM 33-51-38/401. OPS CHECK GOOD, ALL INSTALL TESTS PASS WITH NO FAULT MESSAGES PRESENT.SDR CALA2025100709727Light Sys · malfunctionedINTERIOR EMERGENCY LIGHTS CAME ON FOR 3-5 MIN 6+30 INTO FLIGHT. NO DOOR LGHT OR ELECT ANOMOLY OPS CK EMERGENCY LIGHT NO FAULT NOTED IAW MM 33-51-00 COULD NOT DUPLICATE AT THIS TIME.SDR CALA2025100709726Lamp · no testOPERATIONAL TEST - EMERGENCY ESCAPE PATH LIGHTING (EEL) SYSTEM PERFORM OPERATIONAL CHECK - PATH LIGHT 6D DOESN'T WORK. REMOVED AND REPLACED LAMP ASSY REF 33-51-10-962-105, GOOD FOR SERVICE.SDR CALA2025100709725Power Supply · faultedREF W/C 23-3350-1-0001, DURING CHECK FOUND THAT THE PATH EMERGENCY LIGHTS FROM SEAT ROW 40 TO SEAT ROW 53 WILL NOT COME ON. REMOVED AND REPLACED POWER SUPPLY AND BATTERY REF AMM 33-51-06. OPS CHECK NORMAL.SDR CALA2025100709724Engine · odorDIRTY SOCK SMELL AT TAKEOFF POWER WENT AWAY CRUISE CAME BACK ON IDLE DESCENT NOTED DISCREPANCY ORDOR COCKPIT/FWD. CABIN . NOTED PREVIOUS STATION OVERNIGHT WORK #1 ENGINE WASH. SUSPECT RESIDUAL CONTAMINATION. PERFORM CONTAMINATION REMOVAL #1 AND #2 ENGINES AND SDR CALA2025100709723Unknown · vaporCHEMICAL FUME ODOR AND VISIBLE VAPOR IN WHEEL WELL TUNED ON PACKS AND HYD SYSTEM, UNABLE TO DUPLICATE. NO EVIDENCE OF VAPOR OR ODOR NOTED. REF AMM 05-51-00SDR CALA2025100709722Retainer · looseWHEN FA SHOWED UP DOOR 2L WAS PARTIALLY ARMED AND THE DOOR MIGHT HAVE BEEN OPENED FA FOUND 1/2 OF THE GIRT BAR FALLEN OFF OF RETAINER AND LYING ON THE FLOOR. INSPECTED SLIDE AND GIRT BAR RETAINER. ALL CKS OKAY REF AMM 25-66-01...SUSPECT BAR LOOSELY INSTALLED ISDR CALA2025100709721Slide · out of positionR1 EXIT SLIDE MATERIAL DRAGGING ON FLOOR. REPOSITIONED DOOR 1R. SLIDE LOWER MATERIAL AS REQUIRED, NO LONGER DRAGGING ON FLOOR. REFERENCE B737 AMM 25-64-00.SDR CALA2025100709720Slide · out of adjustDOOR 1L, WHEN ARMED GIRT BAR WILL NOT ENGAGE CORRECTLY. REMOVED SLIDE 1L AND REINSTALLED ORIGINAL SLIDE PER AMM 25-62-44-400-007-A. OPS CHECK GOOD. PERFORMED RII INSPECTION OF L1 SLIDE INSTALL PER GMM 09-25-05 RII INSPECTION OKSDR 2A6D20251006001Keelbeam · damagedA MIS-DRILLED HOLE WAS FOUND ON THE FORWARD LH KEEL BEAM (PN: 350A21-1350-20), AFT LH KEEL BEAM (PN: 350A21-1056- 20) AND FWD KNOT ASSEMBLY LH SPLICE (PN: 350A21-1071-20) LOCATED AT Y400 X 1296. TOOL MARK DAMAGE WAS ALSO DISCOVERED ON THE FWD KNOT ASSEMBLY LSDR GTIA2025100639118A/C Pack · odorFA IN AFT GALLEY CABIN REPORT STRONG DIRTY SOCKS SMELL ON DESCENT & LANDING FWD FA ALSO REPORTED THE SMELL NEAR LANDING. -PERFORMED TSM FOR CABIN ODOR IAW 05-50-00-810-831. IDENTIFIED PACK 2 AS POTENTIAL CAUSE OF EVENT. PERFORMED ECS DECON. LEVEL A REF AMM 21-SDR GTIA2025100639117Unknown · odorFA REPORTED FUME EVENT DURING APPROACH-PERFORMED TSM 05-50-00 FOR CAUSE OF ODOR/SMOKE , CHECKED ENGINES AND APU FOR PROPER SERVICING AND LEAKS. ALL LEVELS NORMAL , NO LEAKS NOTED . OPERATED BOTH PACKS WITH APU / ENGINES NO ODOR WAS NOTED .SDR DALA2025100607269Structure · damagedFOUND LAMINATE DAMAGED IN AFT GALLEY. REPLACED LAMINATE IN AFT GALLEY PER A319 AMM 25-31. (1237070).SDR DALA2025100607275Structure · delaminatedSHIP 3145 FOUND LAMINATE DAMAGED IN FWD GALLEY. CORRECTIVE ACTION: REPLACED LAMINATE PER A319 AMM 25-31. (1237068).SDR JR2R20251006311Bellcrank · chafedLEFT MAIN, NR 1 FLAP CARRIAGE ASSEMBLY, BELL CRANK ASSEMBLY. CHAFED OUT OF LIMITS. REPAIRED.SDR JR2R20251006312Bellcrank · chafedRIGHT MAIN, NR 1 FLAP CARRIAGE ASSEMBLY, BELL CRANK ASSEMBLY. CHAFED OUT OF LIMITS. REPAIRED.SDR F3LA202510060310Battery Pack · no testAIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING OPC FOUND EPSU BATTERY 12WL INOP REPLACEMENT REQUIRED IAW AMM 33-51-38-400-002-A REV 103. REPLACED EPSU BATTERY 12WL IAW AMM 33-51-38-400-002-A REV 103.SDR F3LA202510060309Battery Pack · no testREFERENCE LTPR NR5001428759-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. EPSU BATTERY 11WL WAS REMOVED IAW AMM 33-51-38-400-002-A REV 103. REPLACED EPSU BATTERY 11WL IAW AMM 33-51-38-400-002-A REV.103.SDR YENA2025100300997Seal · damagedFLT#1926, LGW-BOS. (ETOPS) "FOUND FUEL PUMP DRIVE OIL SEAL TO BE DAMAGED; REMOVED AND REPLACED FUEL PUMP OIL SEAL IAW ENGINE MAINTENANCE MANUAL 72-61-01-02A-920A-D."SDR JR2R2025100600268Bellcrank · chafedR/H MAIN, #1 FLAP CARRIAGE ASSEMBLY, BELL CRANK ASSEMBLY. CHAFED OUT OF LIMITS. REPAIREDSDR EE4Y2025100623293Inlet · dentedDURING THE STRUCTURAL INSPECTION, IT WAS FOUND P/N 341-1010-511A, S/N 1395001, AIR INLET MODULE WITH SEVERAL DENTS ON THE INNER BARREL UPPER AND LOWER ACOUSTIC PANELS. THE DENTS WERE EVALUATED AS PER SRM 71-61-01/AD53. MOST OF THE DENTS ARE BEYOND THE LIMITS FSDR EE4Y2025100623292Inlet · dentedDURING THE STRUCTURAL INSPECTION, IT WAS FOUND P/N 341-1010-509F, S/N 1192001, AIR INLET MODULE WITH SEVERAL DENTS ON THE INNER BARREL UPPER AND LOWER ACOUSTIC PANEL. THE DENTS WERE EVALUATED AS PER REF. SRM 71-61-01/AD53. MOST OF THEM ARE BEYOND THE LIMITS FOSDR IXXA20251006002Floorbeam · crackedBULK CARGO FLOOR SUPPORT BEAM CRACKED @ STA1480, RBL14SDR EE4Y2025100623291Skin · damagedAZORRA REPORTS THAT DURING THE STRUCTURE INSPECTION, WE FOUND THE CENTER FUSELAGE I – AT FR31+380MM, S-26R+30MM EXTERNAL SKIN WITH LIGHTNING STRIKE. THE DAMAGE WAS REMOVED BY DRILLING A HOLE (Ø4.0MM). THIS CONDITION WAS REPORTED AND REPAIRED IAW ETD2025-190-92