Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ABXA20251005257Frame · damagedDURING AIRCRAFT N764CK C4-CHECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE DISCOVERED AFT CARGO FRAME WEB AT STA 1395 RBL 5 DAMAGED ,BLENDED AND FOUND TO BE OUT OF LIMITS . ACCOMPLISHED REPAIR AT STA 1395 RBL5 ON FRAME WEB IAW ABX-REA-5360-65922-00 & FSDR ABXA20251005256Skin · damaged"DURING AIRCRAFT N764CK C4-CHECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE DISCOVERED FUSELAGE SKIN CORROSION UNDER STRINGER S-38L AT STA 1395 WHILE PERFORMING A STRINGER SPLICE. THE CORROSION WAS BLENDED IAW B767-300 SRM AND FOUND TO BE OUT OF LIMITS AND SDR ABXA20251005255Stringer · corrodedDURING AIRCRAFT N764CK C4-CHECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE DISCOVERED ,EVIDENCE OF CORROSION FOUND ON STRINGER 32 AT STA. 697 AND REPAIRED STRINGER 32R AT REPAIR STA 682 TO REPAIR STA 713 IAW B767-300 SRM 53-00-02 REPAIR 2..SDR ABXA20251005254Door Sill · corrodedDURING AIRCRAFT N764CK C4-CHECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE DISCOVERED CORROSION DAMAGE AT APPROXIMATELY STA 555 AND STA 610 ON THE OUTER CHORD OF THE FORWARD LOWER CARGO DOOR LOWER SILL. THE CORROSION WAS BLENDED IAW B767-300 SRM AND FOUND TSDR ABXA20251005253Door Sill · corrodedDURING AIRCRAFT N764CK C4-CHECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE DISCOVERED CORROSION DAMAGE AT APPROXIMATELY STA 555 AND STA 610 ON THE OUTER CHORD OF THE FORWARD LOWER CARGO DOOR LOWER SILL. THE CORROSION WAS BLENDED IAW B767-300 SRM AND FOUND TSDR FDEA202510051897Indicator · inoperativeR1 DOOR EVACUATION SLIDE REMOTE PRESSURE PRESS TO TEST INDICATING SYSTEM INOP. REPLACED BATTERIES. OPERATIONAL CHECK GOOD.SDR ABXA20251005252Web · corrodedDURING 4C IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE FOUND FWD CARGO COMPARTMENT R/H AT APPROX STA 610-544 RBL 36.70 WEB IN FRONT OF DOOR CORRODED TB76. FOUND TO BE OUT OF LIMITS . REMOVED AND REPLACED WEB FROM STA 610 - 544 RBL 36.70 IAW B767-300 SRM SDR HNAA2025100600678Wire · brokenROW 15-16 FLOOR PROXIMITY EMERGENCY LIGHTS WIRES BROKEN. REPAIRED THE WIRES IAW SWPM 20-21-00. OPS CHECK GOODSDR ABXA20251005251Skin · corrodedWHILE 764CK WAS UNDERGOING C 4 -CHECK IN OSC, CORROSION WAS FOUND ON THE INNER SURFACE OF THE INNER SKIN AT STA 1177 ALONG THE S-36L LAP JOINT. SEE FIGURE 1. THE CORROSION WAS REMOVED BY BLENDING AND THE BLEND WAS BEYOND THE ALLOWABLE LIMIT GIVEN IN B767 SRMSDR ABXA20251000525Structure · corrodedDURING C 4 IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE FOUND EVIDENCE OF CORROSION ON UPPER CHORD IN AFT CARGO COMPARTMENT AT BS 1373 RBL 8 JM-44..FOUND TO BE OUT OF LIMITS. ACCOMPLISHED REPAIR OF UPPER CHORD AT BS 1373 RBL8 IAW B767-300 SRM 53-00-07 REPASDR ABXA20251005249Door Frame · crackedDURING C 4 CHECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE FOUND CRACK INDICATION FOUND DURING HFEC INSPECTION OF R1 LOWER DOOR CUTOUT. INDICATION IS LOCATED ON R1 DOOR CUTOUT ON AFT LOWER CORNER AS MARKED FOUND TO BE OUT OF LIMITS . ACCOMPLISHED REPAIR SDR ABXA20251005248Stringer · corrodedDURING C 4 CHECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE FOUND AFT CARGO COMPARTMENT HAS EVIDENCE OF CORROSION BETWEEN STATION 1351-1395 AT STRINGER L39. GB6.FOUND TO BE OUT OF LIMITS.ACCOMPLISHED REPAIR ON AFT CARGO STR39L AT REPAIR STA 1354 TO REPASDR ABXA20251005247Stringer · corrodedDURING C 4 CHECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE FOUND AFT LWR CARGO COMPARTMENT HAS EVIDENCE OF CORROSION AT STRINGER 39R AT STA 1307. GB5.FOUND TO BE OUT OF LIMITS REMOVED AND REPLACED AFT LWR CARGO STR39R AT FACTORY SPLICE STA 1219 TO FACTSDR ABXA20251005246Skin · delaminatedDURING C 4 CHECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE FOUND R/H HORZ STAB LOWER SKIN HAS AREA OF DELAMINATION AT AUX SPAR STA 243 JM-30.FOUND TO BE OUT OF LIMITS REMOVED AND REPLACED LOWER SKIN PANEL IAW B767-300 SRM 51-40-02.SDR ABXA20251005245Nut Plate · corrodedDURING C 4 CKECK IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE FOUND FWD CARGO AT APPROX STA 654+44 ON INNER CHORD NUT PLATE HAS EVIDENCE OF CORROSION TB56 FOUND TO BE OUT OF LIMITS AND ACCOMPLISHED REPAIR AT STA 654+44 ON INNER CHORD IAW B767-300 SRM 53-00SDR CALA2025100609662Battery · inoperativeWHEN PERFORMING EMERGENCY LIGHT TEST FROM COCKPIT OR F/A TEST SWITCH OVERHEAD EXIT LAMPS AT DOORS 1L & 1R FAIL TO ILLUMINATE. FAILURE OCCURS WHEN SYSTEM IS IN ARMED MODE, AND AC POWER IS REMOVED. ALSO FAILS WITH NO POWER, AND ON SELECTED ON EMERG LIGHT SWITCH.SDR CALA2025100609661Battery Pack · dischargedMAIN DECK R3 DOOR AFT EMERGENCY POWER SUPPLY M33401 BATTERY PACK FOUND POOR CONDITION. REPLACED M/D R3 DOOR AFT EMERGENCY POWE R SUPPLY M33401 BATTERY PACK AND PERFORMED NEW BATTERY PACK INST ALLATION TEST THE TEST RESULT NORMAL AS PER AMM 33-51-06-960-802 RESDR CALA2025100609617Power Supply · no testOPERATIONAL CHECK OF THE EMERGENCY POWER SUPPLY UNITS BY BITE-CHECK (PRE EA2500-03960 AND EA2500-08031, REFERENCE EC2500-04561 FOR A/C 871-884, 888-899, 901-950 ) JOB SET-UP - BITE CK FAILED R/H EPSU BATTERY MESSAGE. REPLACED R/H EPSU PER AMM 33-51-38-400-001.SDR CALA2025100609608A/C Pack · odorSTRONG SMELL AFTER PACK TRANSFER FROM ENG TO APU AFTER LDG IMAGE OF SMOKE/ODOR IN THE PLANE QUESTIONAIRE ACCOMPLISHED TASK 05-51-26-800-801 INITIAL INSPECTION WITH NO FINDINGS. NO FURTHER ACTION REQUIRED AIRCRAFT IS OK FOR SERVICE.SDR ABXA20251005244Structure · crackedDURING C4 CHECK .IN OSCODA MICHIGAN (OSC), KALITTA MAINTENANCE FOUND CRACK WITH EDDY CURRENT INSPECTION AS MARKED ON INNER CHORED STA 903.5, LBL89. REPAIRED IAW ABX-EA-5300-0051 .REFERENCE W.O. 976402921 FOR CORRECTIVE ACTION.SDR DALA2025100607235Sensor · faultedMISC/DE - DUE TO F/CTL FLAPS LOCKED ECAM WARNING AFTER SELECTING FLAPS 2. REPLACED SFCC 2. AS PRECAUTION REPLACED FLAP/SLAT COMMAND SENSOR UNIT, AND FLAP CONTROL UNIT ASSY. OPS CHECK GOOD. (LP: 7598196)SDR QMLA2025100620099Ics Box · faultedHEAVY STATIC IN ICS SYSTEM. PROBLEM OCCURRED APPROXIMATELY 10-12 MINUTES IN FLIGHT AND THEN DISAPPEARED. INSPECTED AUDIO CONTROLLER/INTERCOM HARNESS AND PINS, COULD NOT DUPLICATE. THIS AIRCRAFT HAS BEEN RETURNED TO REVENUE SERVICE, REF # MEC-016217SDR AALA202510063802Vapor Barrier · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER IN RIGHT HAND WHEEL WELL AT STA 663, RBL 34. REPAIRED VAPOR BARRIER PER AARD 57-10-10-9 AND SRM 57-10-10-2R-2.SDR 2025FA0000680Pump · malfunctionedCREW REPORT - N927CA SN 279 DEPARTED KPHL TO KBCT. ENROUTE TO KBCT THE PILOT IDENTIFIED A HYDRAULIC PUMP FAIL ON THE B SYSTEM. THE CREW PERFORMED CHECK LIST. THE CREW CONTINUED ON THE FLIGHT PATH AND THIRTY TO FORTY MINUTES LATER, THEY LOST ALL FLUID IN THE BSDR IXXA20251005007Stringer · corrodedFUSELAGE STRINGER 37L CORROSION STA 742SDR IXXA20251005006Skin · dentedDENT IN FUSELAGE SKIN BETWEEN 1562 AND 1582,STR 15L - 16L.SDR IXXA20251005005Skin · dentedRIGHT FUSELAGE SKIN DENTED AT STA 1582-1605 STR 16R.SDR JR2R20251005208Shear Panel · corrodedRH SHEAR PANEL BETWEEN FR87 AND 88 AND RBL10 TO RBL 24 IS CORRODED OUT OF LIMITS. REPLACEDSDR JR2R20251005302Shear Panel · corrodedCENTER SHEAR PANEL BETWEEN FR87 AND 88 AND LBL10 TO RBL 10 IS CORRODED OUT OF LIMITS. REPLACEDSDR JR2R20251005209Floor Support · corrodedRIGHT LONG BEAM AT RBL10 IS CORRODED BETWEEN FRAMES 86 AND 87. OUT OF LIMITS. REPLACEDSDR JR2R20251005210Floorbeam · corrodedRH FLOORBEAM UPPER STRAP AT RBL 10 BETWEEN FR85-FR86 IS CORRODED OUT OF LIMITS. REPLACEDSDR JR2R20251005242Floor Splice · corrodedFLOOR SPLICE, DOUBLER AT FR89, RBL10, IS CORRODED. OUT OF LIMITS. REPLACEDSDR JR2R20251005244Support Angle · crackedFLOORBOARD SUPPORT ANGLE AT FRAME 86, RBL24 IS CRACKED. REPLACED.SDR JR2R20251005240Gusset · corrodedGUSSET, TEXAS DOUBLER AT FR90, RBL 24 IS CORRODED OUT OF LIMTS. REPLACEDSDR JR2R20251005243Support Angle · corrodedINTERCOSTAL SUPPORT ANGLE AT FR89 TO FR90, RBL 10 IS CORRODED OUT OF LIMITS. REPLACEDSDR IXXA20251005004Web · corrodedSTA 522 RBL5 CORROSION AROUND GROUND STUD AND WEB.SDR IXXA20251005003Stiffener · bentALC FLOORBEAM WEB BULKHEAD VERTICAL STIFFNER STA 1461 RBL 9, RBL 15 IS BENT.SDR IXXA20251005002Bulkhead Web · bentALC FLOORBEAM WEB BULKHEAD VERICAL STIFFNER STA 1439 RBL15 AND RBL9 IS BENTSDR IXXA20251005001Shear Tie · corrodedFLC SHEAR TIE AT BS 742 STR 37L-38L CORRODEDSDR JR2R20251005248Seal Rest · corrodedFWD CARGO DOOR CUTOUT, LOWER AFT SEAL REST IS CORRODED OUT OF LIMITS. REPLACEDSDR JR2R20251005912Mount Bracket · crackedLOWER WEATHER RADAR SERVO MOUNT BRACKET CRACKED AT RH ATTACH CLIP. REPLACEDSDR JR2R20251005970Sill Drain · corrodedUPPER WEATHER RADAR SERVO MOUNT BRACKET CRACKED AT RH ATTACH CLIP. REPLACEDSDR JR2R20251005241Sill Drain · corrodedRIGHT MOP SILL BETWEEN FR88-FR90, AT RBL 36 IS CORRODED OUT OF LIMTS. REPLACEDSDR VNAA202601170001Skin · dentedSEVERAL DENTS ON EXTERNAL FUSELAGE SKIN BTW FS 1015.00 TO FS 1031.00 BTW STGR 20 LH TO STGR 23 LH. SEVERAL DENTS ON EXTERNAL FUSELAGE SKIN BTW FS 1015.00 TO FS 1031.00 BTW STGR 20 LH TO STGR 23 LH WERE REPAIRED PER REO 670-51-00-085 REV - A AND REO 690-53-61SDR ASAA2025100463649Battery Pack · inoperativeEMERGENCY LIGHTS LH OVERWING INOP. GROUNDED - YES. REPLACED EMERGENCY LIGHT BATTERY & FIXED TERMINAL LUGS FOR EMERGENCY LIGHT CONTROLS IAW B737-800 AMM 33-51-06-960-805 & SWPM 20-30-11 OPS CKS GOOD IAW B737-800 AMM 33-51-00-710-801WO: 2012268REFERENCE_TASK_CARSDR SCNA20251020392SBulb · inoperativeDURING OPERATIONAL CHECK OF THE EMERGENCY LIGHTS, FWD CEILING EMERG LIGHT DONT TURN ON. EMERGENCY LIGHTS, FWD CEILING EMERG LIGHT BULB WAS REPLACED PER B737-800 AMM. 33-51-03-960-801.SDR SWIA202512261004Drag Angle · crackedLEFT FWD VERTICAL STAB DRAG ANGLE CRACKED. PERFORMED REPAIR ON LT FWD VERTICAL STAB DRAG ANGLE IAW SRM 55-31-00-201-001-A01. COMPLIED WITH ALL STEPS OF TASK CARD 51-900-1002-SKY.SDR SWIA202512221004Frame · crackedCRACK IN FLANGE AT FS589 STR26R-25R INBOARD MOST FASTENER FORMED DURING INSTALLATION OF RIVETS. (C-CHECK RO 12/19/2025)PERFORMED REPAIR TO FS589.00 FRAME SECTOR LOWER FLANGE BETWEEN STR25R-STR26R WITH REFERENCE TO REO 601R-53-61-8396 REV "--" DATED 2025-10-17SDR SWIA202512190004Mount Bracket · damagedUPON INSTALLATION OF THE A/C POWER RECEPTACLE BRACKET MOUNT FOUND 1 EA FASTENER HOLE TO BE ELONGATED ON AFT O/B SIDE IN CORNER MARKED WITH RED TAPE. REPAIRED A/C POWER RECEPTACLE BRACKET MOUNT IAW MHIRJ REO 601R-53-11-4026 REV -. COMPLETED SKYCARD 51-900-100SDR SWIA2025121200004Floorbeam · corrodedSIGNS OF CORROSION NOTED AT FLOORBEAM FS280 RBL12. R & R THE FLOORBEAM IAW SRM 53-00-00, AMM 20-70-00, SRM 51-42-06, SRM 51-42-21, SRM 51-42-13, SRM 53-11-10, SRM 51-24-21, SRM 51-40-11, SRM 51-21-11, SRM 51-25-06, AND SRM 51-25-16. PERFORMED NDT INSPECTION,