Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA202507304352Transmitter · faultedDURING ILS COUPLED APPROACH WITH FLAPS AT 35 AND VERIFIED BY CAPT AND F/O GREEN BOX, TOO LOW FLAPS WARNING WENT OFF TWICE CAUSING GO AROUND. REPLACED RT OTBD FLAP POSITION TRANSMITTER IAW MM 27-54-02-400-801.SDR DALA2025073005724Access Panel · corrodedSHIP 3146 RH WING FUEL TANK ACCESS PANEL FASTENER HOLES WITH CORROSION FROM RIB 13 TO RIB 27. CORRECTIVE ACTION: REPLACED FUEL TANK ACESS PANELS 640LB IAW A319 SRM 51-72-11-911-001. (1113837).SDR DALA2025073005723Access Panel · corrodedSHIP 3146 LH WING FUEL TANK ACCESS PANEL FASTENER HOLES WITH CORROSION FROM RIB13 TO RIB 27. CORRECTIVE ACTION: REPLACED FUEL TANK ACESS PANELS IAW A319 SRM 51-72-11-911-001. (1113824).SDR DALA2025073005721Line · unsecureSHIP 692 DOOR 1R WILL NOT ARM. FOUND MOORIMG LINE WRAPPED AROUND GIRT BAR, STOWED CORD PER B757 AMM 25-66-01, DOOR ARMS AND DIS ARMS NORMALLY.SDR UIEA2025072901053Elec Connector · damagedCONFIG WARNING AND FLAPS AFTER CLEAN UP. NOSE GEAR EXTENSION EXPERIENCED A LOUD BANG. SPD LIM MESSAGE NEXT TO 250 KNOTS ON SPEED TAPE WITH FLAPS UP. RESEATED PUSHED BACK ELEC CONNECTOR D1756 PIN 2 IAW SWPM 20-61-00, NO FURTHER DEFECTS NOTED.SDR DALA2025073005719Slide · no testSHIP 6704 LEFT OVERWING ESCAPE SLIDE FAILED TO DEPLOY PER AMDS 2566-2003- LT. REMOVED UNPRESSURIZED BOTTLE PER AMDS WORK CARD 2565-4646-LH. REMOVED OFF WING ESCAPE ACTUATOR AND INSTALLED OFF -WING ESCAPE SYSTEM ACTUATOR PER AMM 25-65-05. SLIDE REPLACED ON WC SDR YENA2025073000787Wire Harness · failedFLT#2220, LHR-JFK. (ETOPS) "UPON ARRIVAL MAINT STATUS MESSAGE ENG 1 FADEC ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 1)FAULT(S) INDICATED BY ENG (1 AND/OR 2) FADEC ); REMOVED AND REPLACED L ENG CONTROL WIRING HARNESS. SDR YENA2025073000786Wire Harness · faultedFLT#816, SFO-JFK. (ETOPS) STATUS II MX MESSAGE AC GEN ( CLASS II MX MSG - GPCU OR AC GEN); T/S PER TSM 24-22-00-810-832-A, UPON PERFORMING WIRING CHECKS FOUND RESISTANCE FLUCTUATING BETWEEN PINS 4000XU-B, PIN 3 AND GCU #2 BACKSHELL A-A13-B. ALL OTHER WIRING CHSDR DALA2025073005714Bracket · damagedSHIP 3416 TOOLING DAMAGE ON FITTING IB SIDE - FORWARD SIDE OF FRAME 62, STRINGER 3L. REPLACED BRACKET PER ERA 627461-14 REV A. (1113427)SDR DALA2025073005713Bracket · damagedSHIP 3416 REINFORCEMENT BRACKET DAMAGED. REPLACED BRACKET PER ERA 627461-14 REV A.SDR YENA2025073000783A/C Pack · odorFLT#311, BOS-ORD. ENVIRONMENTAL ODOR CAME BACK AT 10K WITH LEFT PACK ISOLATED ( AIR CONDITIONING PACK BOTH PACKS INOP ). OPENSDR YENA2025073000782Unknown · odorFLT#1786, PIT-BOS. DIRTY SOCK ODOR OCCURRED AFTER TAKEOFF. PERSISTED FOR 5 MINUTES. OCCURRED AGAIN DURING DESCENT BELOW 10,000 FT, PERSISTED FOR ABOUT 5 MINS. NOTICABLE IN FLIGHT DECK AND LESS NOTICABLE BUT STILL PRESENT IN CABIN. MODERATE ON FLT. DECK, MILD ISDR AALA202507306949Warning Light · illuminatedAIRCRAFT WAS GROUNDED: DOOR 3L SLIDE WILL NOT ARM. MAINTENANCE REPLACED THE 3L DOOR PROXIMITY SWITCH 6WN1 PER AMM 52-73-11 (AALA202507303731) AND REPLACED THE SLIDE ARMED INDICATOR LIGHT AT 3L DOOR PER AMM 52-73-21. (AALA202507306949) A SATISFACTORY OPERATIONASDR AALA202507305708Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202507304475Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202507300083Handle · looseAIRCRAFT WAS NOT GROUNDED: 2L EMERGENCY EXIT ARMING HANDLE IS LOOSE. MAINTENANCE SECURED YELLOW ARM HANDLE ON L2 EXIT DOOR PER AMM 52-21-11.SDR AALA202507300324Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R4 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00.SDR AALA202507303731Proximity Sensor · faultedAIRCRAFT WAS GROUNDED: DOOR 3L SLIDE WILL NOT ARM. MAINTENANCE REPLACED THE 3L DOOR PROXIMITY SWITCH 6WN1 PER AMM 52-73-11 (AALA202507303731) AND REPLACED THE SLIDE ARMED INDICATOR LIGHT AT 3L DOOR PER AMM 52-73-21. (AALA202507306949) A SATISFACTORY OPERATIONASDR AALA202507309961Bottle · no testAIRCRAFT IN BASE MAINTENANCE: PASSENGER / CREW DOOR 841 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER FAILS THE DAMPING FUNCTION TEST. REPLACED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-11-14.SDR CALA2025073007110None · noneBURNING PLASTIC ODOR WHEN BOARDING AIRPLANE. DETERMINED SCENT WAS FUMES FROM GROUND VEHICLES OUTSIDE DUE TO APU BACKDRAFT. AIRED OUT CABIN AND SCENT HAS CLEARED. OK TO CONTINUESDR CALA2025073007105Light · brokenSEAT 3F - AFT PROXIMITY LIGHT BROKEN. REMOVED AND REPLACED THE PROXIMITY LIGHT AT SEAT 3F AS REF IFM 25-25-89. ITEM GOOD FOR SERVICE.SDR CALA2025073007103Battery Pack · faultyEMERGENCY LIGHT BATTERY PACK M1672 FAILED CAPACITY CHECK.EMERGENCY LIGHTING SYSTEM FUNCTIONAL CHECK (INTERIOR AND EXTERIOR). REMOVED AND REPLACED BATTERY PACK IAW AMM 33-51-06-960-805. OPS CHECK GOOD.SDR CALA2025073007101Battery Pack · no testEMERGENCY LIGHTING SYSTEM OPS CHECK, FOUND FORWARD EXTERIOR OVERWING LIGHT AND 2 FORWARD INTERIOR CEILING LIGHTS INOPERATIVE. REPLACED BATTERY PACK IAW AMM 33-51-06. OPS CHECK GOOD.SDR CALA2025073007098Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M1673 FAILED CAPACITY CHECK. EMERGENCY LIGHTING SYSTEM FUNCTIONAL CHECK (INTERIOR AND EXTERIOR). REMOVED AND REPLACED IAW AMM 33-51-06-960-805. OPS CHECK GOOD.SDR CALA2025073007096Chiller · no discrepancyGALLEY CHILLER IS LOUD AND/OR VIBRATING A3 GALLEY CARRIER 406 OP'S CK'D CHILLER REF MM 25-33-97-700-801, OP'S CK NORMAL, DOES OPERATE LOUDER THAN THE FWD CHILLER BUT NO VISIBLE DEFECTS OR SMELLSSDR CALA2025073007076Battery Pack · no testSEVERAL EMERGENCY LIGHTS INOP. (REF AAR N/R 9986389) REMOVED & REPLACED BATTERY PACKS AT POSITIONS M1672 & M1673 AS PER AMM 33-51-06-02. PERFORMED INSTALLATION TEST AS PER B737 AMM 33-51-06-02 (SUBTASK 33-51-06-710-004). TEST FOUND NORMAL, NO DEFECTS NOTED. RESDR JJBA20250730111Shear Tie · crackedZONE 231 FOUND CRACK AT FRAME #20 (STRINGER 3L - SHEAR CLIP). REMOVED AND REPLACED STRINGER 3L - SHEAR CLIP FITTING AT FRAME 20.SDR JJBA20250730110Door Sill · corrodedZONE 132, 232, AND 234 FOUND CORROSION AT THE RH SILL SERVICE DOOR AT FRAMES #20 AND #22 (LOWER BEAM AND SCREW HOLES UNDER FLOOR BOARD). REMOVED AND REPLACED RH SILL SERVICE DOOR LOWER FRAME BETWEEN FR20 AND 22.SDR N6WA2025072901Frame · corrodedCORROSION ON FRAME AT FS250 BETWEEN STRINGER 26LH AND STRINGER 26RH. PERFORMED REPAIR OF FRAME AT FS250 BETWEEN STRINGER 26LH AND STRINGER 26RH IAW EO #25-CRJ5-53-078.SDR SIMA20250729001Doubler · corrodedINNER REINFORCEMENT SKIN AT LAV SERVICE PANEL IS CORRODED. (LEVEL 2 CORROSION). REPAIRED IAW ERJ SRM 53-23-60.SDR SIMA20250729002Battery · inoperativeOVERHEAD EMERGENCY LIGHT ABOVE ROW 2/3 INOP R & R ELPU #2 IAW E175 AMM 33-50-01. OPC GOOD. MEL 33-08 RESTORED.SDR DALA2025072905706Warning Message · illuminatedSHIP 3245 - IFSD/DIV - AIRCRAFT DIVERTED TO BUF DUE TO NR 2 ENGINE COMPRESSOR VANE MESSAGE ALONG WITH EGT OVER LIMIT. ENGINE CHANGE REQUIRED DUE TO EGT LIMITS EXCEEDED.SDR FXGA07292025002Overheat Sensor · activatedTAIL COMPARTMENT TEMP HIGH ILLUMINATED, REPLACED R/H TAIL COMPARTMENT TEMP SENSOR IAW MD-80 AMM 36-20-02. OPERATIONAL CHECK GOODSDR FXGA07292025001Duct Clamp · leakingTAIL COMPARTMENT TEMP HIGH ILLUMINATED, FOUND #2 ENGINE BLEED AIR LEAK IN TAIL SECTION, REPLACED CLAMP IAW MD-80 AMM 20-10-11. GROUND RUN-UP OPERATIONAL CHECK GOOD.SDR IPXA2025072973177Battery Pack · not reportedCUSTOMER REQUEST REMOVE EMERGENCY LIGHT BATTERY 3 EA FOR SHOP TO PERFORM BATTERY FUNCTION TEST. OK TO WORKSDR DALA2025072905703Charger · inoperativeROW 23 - 26, ALL EMERGNCY EXIT LIGHTS INOPERATIVE DURING SVC CHECK CABIN WALKTHROUGH. REPLACED M11487 BATTERY PACK & CHARGER IAW AMM 33-51. OPS CHECK GOOD.SDR QXEA2025072900283Slide · dislodgedFLIGHT 9985. DURING BUSTLE REMOVAL EMERGENCY SLIDE SLID OUT OF ITS POSITION. PARTIAL SLIDE DEPLOYMENT. R2 DOOR EGRESS SLIDE HAS BEEN REMOVED. PLACED ON MEL 25-65-00. INSTALLED NEW EMERGENCY-EVACUATION SLIDE ASSY ON R2 DOOR REF AMM 25-65-01-400-801-A. THIS CSDR AALA202507294543Valve · leakingAIRCRAFT WAS GROUNDED: L2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE AT ZERO. MAINTENANCE TRIED TO SERVICE IT AND WOULD NOT HOLD PRESSURE, SUSPECT BAD SCHRADER VALVE. REPLACED SCHRADER VALVE AND SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDERSDR 2025FA0000531Piston · disintegratedSUPERIOR PISTON ASSY PART # SA640518 INSTALLED. WITHIN 40 HOURS OF INSTALLATION PISTON DISINTEGRATED RESULTING IN EXTREME VIBRATION. ENGINE WAS SHUTDOWN AND LANDING MADE IN FIELD WITHOUT INCIDENT.SDR DALA2025072905701Door Sill · corrodedAIRCRAFT AFT SERVICE DOOR SILL, BOLT HOLE #4 HAS CORROSION EMITTING FROM IT. (P)(M). SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0546:5360-2024/002 00539 REMOVED AND REPLACED FORWARD CORNER STRIKER REF A220 ASRP 52-42-21. (LP# 1112326)SDR DALA2025072905693Angle · damagedSHIP 3416 TOOLING DAMAGE ON CLIP LH FR62. CORRECTIVE ACTION: REPAIRED PER A330 SRM 53-11. (1112353)SDR DALA2025072905692Angle · damagedSHIP 3416 TOOLING DAMAGE ON CLIP FR62 RH. CORRECTIVE ACTION: REPAIRED PER A330 SRM 53-11. (1112350)SDR DALA2025072905689Frame · damagedSHIP 3416 RH FRAME 53.6 TOOLING MARK AND FASTENER DAMAGE ON VIASAT STAND OFF TO FRAME ATTACH POINT. CORRECTIVE ACTION: REPAIRED PER ERA 627776-14MT REV. ORIG. (1112688)SDR DALA2025072905685Structure · damagedSHIP 3114 FOUND LAMINATE DAMAGED IN FWD GALLEY. CORRECTIVE ACTION: REPLACED LAMINATE IN FWD GALLEY PER A319 AMM 25-31. (1112868).SDR FDEA202507291337Skin · damagedRH WING NO.8 SLAT OUTER SKIN FASTENER HOLE FOUND WORN OUT AT ISS 184. RH WING NO.8 SLAT OUTER SKIN AT ISS 184 WORN OF FASTENER HOLE REPAIRED AS PER B777 SRM 57-43-01-2R REPAIR 6 FIG 203 REV47.6 AND EA G-5750-T0384293 P1,TITLE:WING-FLIGHT SURFACES-RH WING #SDR QR9R2025072900001Thermocouple · failedENG PA DISC AND #2 FLI DEGRADED CAUTIONS ILLUMINATED DURING FLIGHT. TROUBLESHOOTING REVEALED #2 ENGINE TOT INDICATION FLUCTUATES FROM 25 TO 50 DEG ON BATTERY POWER. REMOVED AND REPLACED #2 ENGINE TOT BOX IAW 77-22-00-900-801-A01. MTF MOC COMPLETED IAW RFM, NO SDR X2ZR202607283587Drive Shaft · wornFUEL CONTROL UNIT P/N 897801-2, S/N: 2122481 WAS RECEIVED FOR PRECAUTIONARY SPLINE INSPECTIONS DUE TO CUSTOMER REPORTED ACCELERATED STUB SHAFT SPLINE WEAR. DISASSEMBLY AND INSPECTION REVEALED STUB DRIVE SHAFT P/N 3499-096 WITH ACCELERATED WEAR ON INTERNAL SPLISDR SWIA2025102000728Skin · corrodedMID. FUSELAGE SKIN UNDER FORWARD WING - TO - FUSELAGE FAIRING SEALANT BED HAS NUMEROUS AREAS OF CORROSION AROUND NUTPLATE HOLES. MARKED WITH TAPE. (C-CHECK RO 10/19/2025)REPAIRED FUSELAGE SKIN UNDER FORWARD WING TO FUSELAGE FAIRING SEALANT BED AROUND NUTPLATESDR SWIA2025F01374Panel · corrodedLANDING FOR PANEL 312DZ HAS POSSIBLE CORROSION WHERE THE PAINT IS REMOVED. (S/N#00521) (C-CHECK RO 09/24/2025)BLENDED OUT CORROSION LANDING FOR PANEL 312DZ AND RESTORED FINISH. FOUND WITHIN LIMITS. REF. REO 601R-53-61-8370 REV.-- ISSUED 2025-08-18.COMPLIED WISDR SWIA2025F01373Support Beam · chafedZIP TIE CHAFFING ON UPPER SURFACE OF ENGINE SUPPORT BEAM. (MARKED) ((S/N#00520) (C-CHECK RO 09/24/2025)BLENDED OUT CHAFE ON UPPER SURFACE OF THE ENGINE SUPPORT BEAM, AND RESTORED FINISH REWORKED AREA. COMPLIED TO ALL STEPS REF REO 601R-53-61-8366 REV -- DATE: