Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2025060604343Battery Pack · inoperativeSHIP 9512 DURING SVC CHK FOUND ENERGENCY LIGHTS SEAT ROW 25 TO AFT OF CABIN INOP. T/S REF B717 SSM 33-51 REPLACED BATTERY PACK B5-231 REF B717 AMM 33-51. CHECKS GOOD (7262863)SDR CALA2025060605323Light · looseEMER LT 9F LOOSE RESECURED AFT FLOOR PROXIMITY LIGHT SEAT 9F. LIGHT TEST FAILED. DEFERRED AFT SEAT-MOUNTED PROXIMITY LIGHT AT SEAT 9F AS PER MEL 33514V. M PROC C/W. TOMC APPROVED DEFERRED AFT SEAT-MOUNTED PROXIMITY LIGHT AT SEAT 9F AS PER MEL 3351V. M PROC C/WSDR NACA2025060100001Warning Light · illuminatedLEFT PACK LIGHT ON AFTER ENGINE START. DEFERRED PER MEL 21-51-01-01 CAT C ON 6/1/2025. REMOVED AND REPLACED THE LH PACK ON/OFF SWITCH IAW CMM 21-51-19, OPS CHECK NORMAL IAW AMM 21-51-00.SDR DALA2025060504303Pin · fouledSHIP 3145 SLIDE DISARMING PIN ATTACHING LANYARD MISSING OR DAMAGED. CORRECTIVE ACTION: REPLACED PIN IAW IPC 25-62-01-37A. (1000039).SDR SWAA2025060577149Bulb · burnedFWD ENTRY AREA UPPER EMERGENCY LIGHT 1EA BURN BULB 2025-291369 <[01]. REPLACED FWD ENTRY AREA UPPER EMERGENCY LIGHT 1EA IAW B737-700 AMM 33-51-01-960-801. TEST IS OK; [02] REPLACED FWD ENTRY AREA UPPER EMERGENCY LIGHT 1EA IAW B737-700 AMM 33-51-01-960-801. SDR SWAA2025060577150Battery Pack · inoperativePAX CABIN BULLNOSE EMERGENCY LIGHTS INOP FROM 14CBA TO 23 CBA AND 22FED AT RH SIDE 2025-291366 <[01] PERFORMED BATTERY PACK DEEP-CYCLE PROCEDURE IAW B737-700 AMM 33-51-06-600-802. TEST IS OK.; [02] CORRECTED STEP 1. PERFORMED BATTERY PACK DEEP-CYCLE PROCEDURESDR SWAA2025060577151Battery Pack · inoperativeAFT GALLEY AREA EMERGENCY LIGHTS INOP AT SERVICE DOOR; G4 AND AFT LAV POSITIONS 2025-291367 <[01]. PERFORMED BATTERY PACK DEEP-CYCLE PROCEDURE IAW B737-700 AMM 33-51-06-600-802. TEST IS OK.; [02] CORRECTED STEP 1. PERFORMED BATTERY PACK DEEP-CYCLE PROCEDURE SDR SWIA2025065000001Acm · faultedLH PACK HI TEMP MSG POPPED UP AND DISAPPEARED FROM CAS CLIMBING THROUGH FL180. CA CHECKED ECS PAGE AND NOTICED LEFT PACK WAS NO LONGER BEING SUPPLIED 10TH STAGE BLEED AIR. WE LEVELED OFF CABIN ALT CAUTION MESSAGE POPPED UP AND CA NOTICED CABIN ALT SLOWLY CLIMBSDR AALA202506059401Gust Lock · inoperativeAIRCRAFT WAS GROUNDED: L1 DOOR GUST LOCK WILL NOT ENGAGE. **SUPPLEMENTAL REPORT FOR (AALA202506029401): INSTALLED AND RIGGED GUIDE ARM (AALA202506040273) AND ROLLER ASSEMBLY (AALA202506057208) ON L1 FORWARD ENTRY DOOR. PER AMM 52-11-21**(CLOSED).SDR AALA202506059485Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION AT LH AFT MLG DOOR ACTUATOR FITTING. MAINTENANCE REPLACED LH AFT MLG DOOR ACTUATOR FITTING IAW EA 365213.SDR AALA202506056993Cover · brokenAIRCRAFT WAS NOT GROUNDED: DOOR GETS CAUGHT WHEN OPENING FROM OUTSIDE. HAD TO PUSH DOOR OPEN FROM INSIDE 1L. MAINTENANCE INSPECTED AND FOUND L1 DOOR SLIDE COVER BROKEN AND CAUSING DOORTO JAM. REMOVED AND REPLACED SLIDE COVER IAW AMM 25-62-50.SDR U2RA2025060500016Fire Detector · false indicationIN CRUISE, FIRE MN DK AFT EICAS MESSAGE DISPLAYED INTERMITTANTLY - TROUBLESHOOTING IN PROGRESSSDR CALA2025060505289Window Frame · crackedFOR SSFR/ SDR PORPUSE ONLY IN REF/EA#5310-08195 REV B-OP-004-R/H SIDE#3 WINDOW FROM PREVENTATIVE MOD. (REF AAR N/R 9963945) FOR ESFR AND SDR REPORTING ONLY. COMPLETED WITH THE SDR UNITED FORM#46-0024 PAGE#1 TO PAGE#3 REF. AAR N/R:9963945 WORK ACCOMPLISHED BY:VSDR DXTA2025060403725Unknown · odorAFTER STARTING THE APU THE CABIN AND COCKPIT HAD A VERY STRONG ODOR OF WET SOCKS. ARRIVED AT THE AIRCRAFT AND APPLIED APU POWER, ALLOWING THE SYSTEMS TO FULLY BOOT UP. AFTER APPLYING APU BLEED, WE WERE ABLE TO CONFIRM THE REPORTED ODOR DISCREPANCY IN BOTH THSDR DXTA2025060403727Handle · bindingMAIN CABIN DOOR REQUIRES EXCESSIVE FORCE TO OPEN OR CLOSE. FROM THE CLOSED AND LOCKED POSITION, MOVING CABIN DOOR HANDLE TO THE OPEN POSITION IS MORE DIFFICULT THAN CLOSING. THE DOOR SHOWS 9 FLAGS CORRECTLY AND THE APPROPRIATE LIGHTS EXTINGUISH. PLEASE EVALUATSDR DXTA2025060403729Acm · failedAFTER LANDING DURING ROLL OUT WE SMELLED AN ODOR THAT SMELLED LIKE SMOKE & HAD A DIRTY SOCK SMELL. WE HAD VISIBLE SMOKE IN CABIN. APU WAS NOT ON AT THIS TIME. DURING TAXI WHILE APU WAS BEING STARTED RECEIVED AN AMBER PACK TEMP HIGH MSG. ARRIVED AIRCRAFT &SDR CALA2025060405272Smoke Detector · false activation4L LAV SMOKE DETCTOR WENT OFF THEN STOPPED NO SMOKE APPLY MEL 2613F THE ZMU WAS REPLACED, THE SMOKE DETECTOR TESTED GOOD AND NO FAULTS REPORTED ON THE CACP ALL TEST. REF LOG #5063824SDR CALA2025060405264Floorbeam · corrodedMAIN CABIN AFT WET AREA STA 986.5 BETWEEN LBL 43" TO RBL 10" FLOOR BEAM EXISTING REPAIR HAVE CORROSION. (REF AAR N/R 9963650) FOR ESFR ENTRY ONLY. ACOMPLISHED REPAIR AT FLOOR BEAM STA 986.5 BETWEEN LBL-43 TO RBL-10 IAW -EC/RA #5370-01176.SDR CALA2025060405246Girt Bar · unsecure1R GIRT BAR MATERIAL SAGGING ON GROUND RESECURED ZFOLD ON THE ESCAPE SLIDE PACK REF AMM 25-66-01SDR CALA2025060105153Panel · missingPDA 2 REF LP 5040261, #1 ENGINE PANEL 436BR MISSING UPON ARRIVAL. REF LP 5039727, GOING TO APPLY CDL 54D INSTALLED INBOARD ACCESS DOOR ON #1 ENG PYLON IN REF TO AMM 54-53-00 PARTS USED: 76-5453-3-0063,QTY :1SDR ASAA2025060158385Lens · brokenSEAT 16F LOWER, DIRECTIONAL EMERGENCY EXIT LIGHT SIGN COVER BROKE OFF. GROUNDED - YES. REPLACED LENS COVER AS REQUIRED. EMERGENCY LIGHT OPERATES NORMALLY.SDR DALA2025060304248Handle · bindingSHIP 5810 L1 DOOR WILL NOT OPEN. THE HANDLE MOVES 1/2 WAY THEN IT FEELS STUCK. CORRECTIVE ACTION: FOUND DIXIE CUP AT LOWER DOOR SILL BETWEEN DOOR AND SILL PLATE, REMOVED DEBRIS, OPS NORMAL PER B757AMM 52-11. (7524120)SDR SWAA2025060377055Holder · brokenFWD GALLEY EMERGENCY FLASHLIGHT HOLDER BROKEN <[01]. REPLACED BROKEN FLASHLIGHT HOLDER PER SRM 51-40-01 AND AMM 25-64-00.SDR SWAA2025060377259Megaphone · inoperativeAFT MEGAPHONE INOP <[01]. REMOVED AND REPLACED AFT MEGAPHONE PER AMM25-64-00.SDR SWAA2025060376794Cover · missing9C EMER LIGHT LENS COVER MISSING <[01]. OK TO CONTINUE PER MEL 33-15-02 SP1 SECURED WITH TAPE; [02] INSTALLED EMERGENCY LIGHT COVER AT SEAT 9C PER SIP.SDR DALA2025060304237Light · inoperativeSHIP 3272 DISC: ROW 14, 15, 16, 17 SEAT MOUNTED FLOOR EMERGENCY LIGHTS INOP. C/A: R/R EPSU 12WL BATTERY IAW 320 AMM 33-51. NO FIX. REINSTALLED ORIGINAL. SWAPPED EPSU 11WL AND 12WL IAW 320 AMM 33-51. NO FIX. FOUND BROKEN WIRE UNDER SEAT 14 DEF AFTER CANNON PLUGSDR FDEA202506010827Lamp · failedNOSE GEAR GREEN LIGHT ON FORWARD PANEL INOP RELAMPED NOSE LANDING GEAR DOWN INDICATING BULB PER AMM 33-11-17-2. OPS CHECK GOOD. A/C OK FOR SERVICE.SDR AALA202506036307Actuator · stuckAIRCRAFT WAS GROUNDED: FLIGHT CREW REPORTED THAT A CENTER LEFT FUEL TRANSFER FAULT ECAM MESSAGE DISPLAYED AND THAT THE CENTER LEFT TRANSFER PUMP DID NOT WORK IN EITHER AUTO OR MANUAL MODE. ON FUEL SD PAGE IT SHOWED AMBER XX FOR CENTER LEFT TRANSFER PUMP AT ALLSDR CALA2025060305231Skin · damaged(#3) FOUND LIGHTENING STRIKE BTW STA 178 AND STA 188. BTW LBL 40 AND BL 0.AFTE FURTHER INSPECTION, DAMAGE FOUND TO BE LESS THAN 10" AWAY FROM AN CUTOUT. REF SRM 53-00-01-2R-38. NOT APPLICABLE. PERFORMED DVI UNDER OF THE INTERNAL AND EXTERNAL SKIN AROUND THE THSDR CALA2025060305230Skin · corrodedEXT SKIN CORRODED AT THE AFT LWR CORNER OF THE LAVATORY WASTE PAN CUTOUT AT STA 867 BETWEEN STR 24L AND 25L. INTERIM REPAIR ACCOMPLISHED PER ECRA 5330-07536 PART 1. PER PART 2 NEED TO ACCOMPLISH A PERMANENT RPR TO THE SKIN AT STA 867 BEWTEEN S-24L AND S-25L IASDR CALA2025060305227Pump · unsecureHYD B SYS LO PR IN FLIGH T TURNED BLUE PUMP OFF FOUND EVIDENCE OF HYD LEAK IN LEFT WHEEL WELL AREA AND AFT BELLY - FOUND BLUE PUMP 2074GJ PRESSURE SWITCH EXTREMLY LOOSE AND NOT SAFETY WIRED. SECURED SWITCH REF AMM 29-12-17/401. NO LEAKS NOTEDSDR CALA2025060305226Check Valve · faultedHYD Y RSVR OVHT ECAM REPORTED BY FLIGHT CREW VIA ARINC TO DISPATCH, CREW C/W QRH AND SHUTOFF HYD Y ENG 2 PUMP. CREW REPORTED THAT THEY HAD NOT RUN THE YELLOW ELECTRIC PUMP. ONLY EDP WAS USED DURING OVERHEAT. OVER HEAT MSG WENT AWAY IN FLIGHT AFTER TURNING OFFSDR CALA2025060305224None · noneSEVERE TURB ON APPCH TO CYYC REF AMM 05-51-17. ACCOMPLISHED SEVERE TURBULENCE INSPECTION UP TO AND INCLUDING STEP F AND ALSO INCLUDING STEP J IN REFERENCE TO AMM 05-51-17-200-001-A NEED TO ACCOMPLISH STEP G,H, AND K. NO FAULTS FOUND. PER TASK 05-51-17-200-0SDR CALA2025060305223Shutoff Valve · faultedENG ANTI-ICE LIGHT ILLUMINATED IN FLIGHT SEE LOG PAGE 5050989. PRSOV AND INTERMEDIATE MANIFOLD PRESSURE SENSOR REMOVED AND REPLACED REF AMM 36-11-04-801 AND 36-11-05-400-801. TEST PASSED DUCT PRESS NEEDLES SPLIT 10-20 PSI DIFFERENCE ON GROUND AND IN C LIMB - RSDR CALA2025060305214Skin · cracked(SDR) (SUPPORT TASK) #1 ENG UPPER PYLON BULLNOSE FAIRING (GAP PA NEL) HAS CRACK. SFR REPORTING ONLY REPAIRED WING FIXED LE NOSE SKIN IAW B757-300 SRM 57-41-01. V950 914SDR CALA2025060305213Floor Support · corrodedCABIN L/H O/B FLOOR SUPPORT HAS CORROSIO N STA 1660-1680, LBL-57". SDR REPORTING ONLY REMOVED CORROSION 1-L=1.900" W=1.250" D=0.011",2-L=2.050" W=1.45 " D=0.024",3-L=2.030" W=1.285" D=0.027" AT L/H O/B FLOOR SUPPORT STA1660-1680 LBK 57"APPROX IAW B757-300 SRM SDR YENA2025060300559Structure · ground damageDAMAGE DUE TO TUG IMPACT. REPAIRED IAW EC A25-185-01, EC A25-185-02, EC A25-185-03, TD/81547580/079/2025#A, MESSAGE 81547580/076, ST2 SRM 53-21-12-300-007, TD/81547580/113/2025#ASDR YENA2025060300558Structure · ground damageDURING HEAVY MAINTENANCE FWD FR 29-34 & STR 41R – 34L DAMAGED DUE TO TUG IMPACT. REPAIRED IAW EC A25-185-01, EC A25-185-02, EC A25-185-03, TD/81547580/079/2025#A, MESSAGE 81547580/092 & 098, SRM 53-21-12-300-007, R53212454004 ISSUE, RI R53210020000 ISSUE ASDR UIEA2025060200717Battery · no testEMERGENCY ESCAPE RIGHT SQUIB TEST DOES NOT COME ON WITH TEST 2.(<P>REMOVED AND REPLACED OFF WING EMERGENCY ESCAPE SYSTEM BATTERY IAW AMM 25-65-17 AND AIPC 25-65-17-10A. NO FIX. FOUND CONNECTOR FOR SPOILER OVERRIDE ACTUATOR UNPLUGGED. RECONNECTED IAW SWPM 20-60SDR HALA20250602160Igniter · faultedETOPS - APU FAULT ON TAXI INTO GATE. APU AUTO SHUTDOWN. BITE TEST SHOWS CLASS 2 IGN PLUG/ IGN EXCITER MESSAGE, REMOVE AND REPLACE BOTH APU IGN PLUG PER AMM 49-41-41/201 & OPS CHECK GOOD, CYCLED 4 TIMES WITH NO DEFECTS NOTED, BITE TEST OK, NO MESSAGES DISPLAYEDSDR DXTA2025060203717Oxygen Mask · unwanted deployMX LEFT THE PASSENGER OXYGEN KNOB TO OFF. WHEN I ROTATED THE PASS OXY KNOB TO AUTO ALL THE MASKS DEPLOYED. REPACKED PASSENGER OXYGEN MASK WORK DONE REF. CESSNA CE-680 AMM 35-20-00. NO FURTHER DEFECTS NOTED. VERIFIED OXYGEN LEVEL IS STILL GOOD.SDR DXTA2025060203726Battery Pack · inoperativeTHE EMERGENCY LIGHTS ASSOCIATED WITH THE #4 BATTERY PACK ARE NOT WORKING, EVEN AFTER TWO 30 MIN CHARGE CYCLES PER THE QRH. LIGHTS AFFECTED ARE AFT BULKHEAD EXIT, THE EXIT LIGHT ON FRONT PANEL OF LAV SEAT, & THE UNDER FLOOR LIGHTING IN FRONT OF LAV SEAT. THE SDR GTIA2025060238939A/C Pack · odorFUME EVENT DESCENDING ON ARRIVAL THROUGH 14,000FT. RAN ELIMINATION OF ODOR/FUMES PROCEDURE AND ISSUE DISSIPATED AFTER PACK 1 WAS SELECTED OFF--SDR GTIA2025060238938Knob · missingMEGA PHONE BROKEN VOLUME KNOB MISSING ( MEGAPHONES )-R+R FWD MEGAPHONE ,TEST OK IAW AMM 25-60-00,THIS CLEARS DIM # 3373003-1.MOC NOTIFIED PLACARD REMOVED.SDR SWIA20250601Oxygen Mask · deployedPAX OXY DEPLOYED. DEFERRED ALL PASSENGER O2 MASKS IN CABIN INCLUDING FA AFTER BEING DISCHARGED IN FLIGHT PER 35-20-1A. NO MX REQUIRED. (FA MASK IS USED AND STOWED FOR ACCESS TO FLIGHT DECK). PLACARD INSTALLEDSDR GTIA2025060238937Power Supply · inoperativeDURING BITE TEST OF EMERGENCY POWER SUPPLY UNITS WAS FOUND FAULT EPSU 10WL-REMOVED AND REPLACED EPSU IOWL I.A.W AMM 33-51-38-000-001-A AND AMM 33-51-38-400-001-ASDR GTIA2025060238935Pump · inoperativeHYD G RSVR LO LVL HYD G ENG 1 PUMP LO PR. FAULT LIGHT ON BOTH PTU AND ENG 1 PUMP. ALL HYDRAULIC INDICATIONS PRESS AND QTY NORMAL. -PERFORMED TSM 29-11-00-810-805-A SYST PRESS SW 1151GM CONTINUITY CHECKS GOOD. CONTINUITY CHECK BETWEEN 1151GM AND FWC'S (1+2) GOOSDR SWAA2025060277070Sensor · inoperativeAIRCRAFT HAD ABRUPT UNCOMMANDED ROLL EVENT AT 39000FT .78 MACH AFTER RECOVERY LH TRAILING EDGE FLAPS INDICATED .5 DEGREE DEPLOYED A/C LANDED UNEVENTFULLY WITH FLAPS UP. BRAKE COOLING WAS PERFORMED AND AN EMERGENCY WAS DECLARED <[01]. OK TO CONTINUE PER MX NOTSDR GTIA2025060238936Slide · faultyREPLACE SLIDE RAFT PASSENGER CREW DOOR 831 FWD GALLEY ARE I.A.W. TSM 25*-62-000-810-811-A DUE TO INTERNAL LIGHT FAULT -REPLACED SLIDE RAFT PASSENGER CREW DOOR 831 AT FWD GALLEY AREA I.A.W. AMM 25-62-44-400-007.SDR AALA202506020258Door · bindingAIRCRAFT WAS NOT GROUNDED: LAVATORY-D DOOR JAMMED CLOSED. LUBED LAVATORY-E DOOR, PER AMM 52-51-14. OPERTIONAL CHECK NORMAL.