Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2025051057887Cover · detachedSEAT 17A EMERGENCY EXIT LIGHT COVER FOR FLOOR LEVEL LIGHT IS DETACHED-COVER FOUND. GROUNDED - YES. REPLACED 17A EMERGENCY EXIT LIGHT COVER REF AMM 33-51-01, NO FURTHER DEFECTS NOTED.SDR ASAA2025051057849Track · lack of lubeFA REPORTS L1 DOOR IS DIFFICULT TO OPEN. GROUNDED - YES. CLEANED AND LUBRICATED GUIDE PLATE TRACK OF L1. OPS CHECK NORMAL REF AMM 52-11-00.SDR ASAA2025051057828Power Supply · inoperativeEMERGENCY LIGHTS ASSOCIATED WITH POWER SUPPLY M1670 ARE INOP. GROUNDED - YES. REMOVED AND REPLACED NEW POWER SUPPLY M1670 IAW B737 AMM 33-5106-960-806. TEST GOOD. (S/N 126432)SDR WX0A2025051232426Power Supply · no test(AIRCRAFT NOT GROUNDED) 4 EPSU FAILED OPS CHECK / REMOVED AND REPLACED EPSU BATTERY REF WO 520704"SDR WX0A2025051232421Oxygen Mask · broken(AIRCRAFT NOT GROUNDED) AFT CENTER GALLEY OXYGEN MASK ASSEMBLY BROKEN. / REMOVED AND REPLACED OXYGEN MODULE IN THE AFT GALLEY CEILING W/REF TO AMM 35-21-41-400-001-A, OPERATIONAL CHECK GOOD. THIS CLEARS MEL 35-21-01-E CAT B MDDR # 212183, INOP PLACARDS REMOVEDSDR DALA2025051203680Hinge Fitting · corrodedFRETTING CORROSION (UT) THICKNESS MEASUREMENT WAS ACCOMPLISHED PLATE RH OUTBD ON VERTICAL STABILIZER SPAR HINGE. FITTINGS WITH ORIGINAL THICKNESS =0.250" AND MINIMUM REMAINING THICKNESS IS 0.212" THEREFORE IT IS OUT LIMITS. SUMMARY OF NRC 00820: CORROSION LEVESDR GTIA2025051238915Unknown · odorFUME EVENT DURING CLIMBOUT , TAXI , AND DURING DESCENT. DURING CLIMBOUT RAN CHECKLIST TURNED PACK # 1 OFF SMELL WENT AWAY. DURING DESCENT SMELL CAME BACK AT 3200 FEET TURNED BOTH PACKS OFF AFTER RERUNNING CHECKLIST. DURING TAXI IN SMELL CAME BACK AFTER TROUBLESDR GTIA2025051238914Proximity Sensor · inoperativeF/CTL ANTI ICE STBY PITOT, LG SHOCK ABSORBER FAULT, AUTO FLT AP OFF, AUTO FLT A/THR OFF-ACCOMPLISHED INSPECTION OF NLG PROX SENSOR 25GA , NO DEFECTS NOTED.AND BITE OF LGCIU IAW AMM 32-31-73-200-002-A AND 32-69-00. . R/R NLG PROX SENSOR IAW 32-31-73. FAULT CSDR YENA2025051200471Sdac · faultedFLT#423, JFK-LAX. (ETOPS)' ( ECAM HYD PAGE INDICATIONS 7) PUMPS ).' REF TECH SUPPORT REQUEST CONT WITH TSM TASK 29-11-810-809-A. REMOVED AND REPLACED SDAC 1-1WV1- GREEN AND YELLOW INDICATION IN NORMAL CONDITION. SDAC INSTALATION IAW AMM 31-55-34-400-001-A. SDR GTIA2025051238913Unknown · odorFUME EVENT PLANE SMELLS BAD CLIMB AND DESCENT. DESCRIPTION OF ODOR/FUMES: PERSISTENT, DIRTY SOCKS SMELL. APPARENT CABIN SOURCE: UNKNOWN. FLIGHT DECK AND FWD CABIN. NO VISIBLE SMOKE/HAZE. NO MEDICAL ATTENTION REQUIRED.-AS PER TSM 05-50-00-810-831-A PERFOMED DECSDR DXTA2025051003427Battery · dischargedCABIN EMERG LIGHT: EMER LIGHTS COME ON FOR A SEC THEN GO OUT DURING PREFLIGHT TEST. CORRECTIVE ACTION: FOUND ALL 4 EMERGENCY LIGHT BATTERIES DISCHARGED. CHARGED BATTERIES AND PERFORMED EMERGENCY LIGHTS OPERATIONAL CHECK IAW CE 680A AMM 33-50-00. OPERATIONAL CHSDR DXTA2025051003434Light · no discrepancyDURING PREFLIGHT NO EMERGENCY LIGHTS CAME ON IN THE ARMED POSITION. IN THE ON POSITION THEY COME ON EXCEPT FOR THE EXIT LIGHTS TO THE LEFT AND RIGHT OF THE ENTRY DOOR AND THE FORWARD TOE KICK LIGHT UNDER SEAT DO NOT COME ON IN EITHER POSITION. CHARGING PROCESDR DXTA2025051003435Tee Fitting · leakingOXYGEN PRESSURE INDICATION: REPEAT WRITE UP. RETURNED TO AC THIS MORNING AFTER AOG OF 02 INDICATING SYSTEM LAST NIGHT. INITIAL INDICATION WAS 1700 PSI. INDICATION IN NOSE COMPARTMENT WAS IN THE GREEN ARC. AFTER AN 1.5 OF FLIGHT INDICATION IN THE COCKPIT EIS WASDR GTIA2025051238912Oil System · overservicedFA SMELL FOUL ODOR THROUGHT OUT THE CABIN-REF TSM 05-50-00-810-831-A. FOUND APU, ENG #1 AND ENG #2 OVERSERVICED. DRAINED ENG 1 AND 2 TO LIMITS IAW AMM 12-13-79. DRAINED APU TO LIMIT IAW AMM 49-90-00. PERFORMED ECS PROCEDURE IAW AMM 21-00-00. NO SMELL/ODOSDR GTIA2025051238911Megaphone · inoperativeFWD F/A MEGAPHONE KNOB MIA-R&R MEGAPHONE IAW AMM 25-63-00SDR GTIA2025051238910Blower · inoperativeBOTH PILOTS COULD DETECT AN ELECTRICAL SMELL INTERMITTENTLY IN THE COCKPIT. HEARD LOUD HUMMING AND SHORT SOUND OF FAN STRIKING SHROUD-FOUND RUMBLING NOISE IN THE COCPIT.PERFORMED TSM 21-26-00-810-837-A.R/R FAN BLEWER 20HQ OPS CHECK GOOD NO DEFECT NOTED A.A/C SDR AALA202505127049Circuit Breaker · trippedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS NOT DECLARED DUE TO: POTABLE WATER FRONT AND REAR INOPERATIVE. AIRCRAFT DIVERTED TO AND LANDED SAFELY AT CLT. FOUND CB D11, P6-4 PANEL. NO HISTORY FOUND, PER GPM 13-04-7. CLOSED CIRCUIT BREAKER AND OPERTIONAL CHECK GOOD.SDR AALA202505125483Circuit Breaker · trippedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS NOT DECLARED DUE TO: ALL LAVATORY CAN NOT BE FLUSH. AIRCRAFT DIVERTED TO AND LANDED SAFELY AT CLT. FOUND CIRCUIT BREAKER D11, P6-4 PANEL. NO HISTORY FOUND. PER GPM 13-04-7. CLOSED AND PERFORMED OPERTIONAL CHECK OF TOILETSDR AALA202505121155Switch · failedAIRCRAFT WAS NOT GROUNDED: LEFT MAIN TANK AFT FUEL PUMP STAYS PRESSURIZED WITH SWITCH IN THE OFF POSITION. REMOVED AND REPLACED S4 SWITCH, OPERTIONAL CHECK GOOD. PER FIM 28-22-00-810-803.SDR AALA202505129044Girt Bar · out of adjustAIRCRAFT WAS NOT GROUNDED: FORWARD SERVICE DOOR GIRT BAR LOOSE IN CLIP. ADJUSTED CLIP AND OPERTIONAL CHECK GOOD. PER AMM 25-66-01.SDR AALA202505123322Hinge · out of adjustAIRCRAFT WAS NOT GROUNDED: AFT LAVATORY-D DOOR DIFFICULT TO OPEN AND CLOSE. ADJUSTED LAVATORY-D DOOR HINGE, OPERTIONAL CHECK GOOD. PER CMM 25-40-58.SDR IPXA2025051219015Door Latch · brokenCAPTAIN SIDE ESCAPE ROPE DOOR ASSY LATCH BROKEN REMOVED AND REPLACED CAPTAIN SIDE ESCAPE ROPE DOOR ASSY AS REQUIRED.SDR IPXA2025051215997Evas Unit · no testCAPTAINS EVAS OPS CHECK FAILED. BLOWER DOES NOT RUN. REMOVED AND REPLACED CAPTAINS EVAS PER AMM 25-69-00. OPS CHECK GOOD.SDR AALA202505120133Oven · odorAIRCRAFT WAS NOT GROUNDED: NO 5 OVEN HAS A ELECTRICAL BURNING SMELL WHEN USED. MAINTENANCE REPLACED NO5 SINGLE OVEN AND OPS NOW AS PER NORM IAW CMM 25-36-30.SDR AALA202505122302Light · inoperativeAIRCRAFT WAS NOT GROUNDED: R2 EMERGENCY SLIDE LIGHT ASSEMBLY INOP. (OPEN)SDR AALA202505129229Elec Connector · disconnectedAIRCRAFT WAS NOT GROUNDED: DURING PS CHECK FOUND EMG EXIT LIGHTS INOP FROM ROW 26 THROUGH 40. MAINTENANCE FOUND PLUG DISCONECTED AND CONNECTED PLUG P1 AT SEAT 26. EPL OPS NORMALIAW AMM 33-51-00.SDR AALA202505121643Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY FWD BEARING MAIN DOOR AT LH MAIN LANDING GEAR. MAINTENANCE REPLACED AND DRILLED NEW HINGE FITTING ASSY LOCATED AT MAIN DOOR ON LH MAIN LANDING GEAR IAW AIRBUS CMM 52-81-18 AND A319 SRM51-44-11-801.SDR AALA202505120826Bearing · excess playAIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY FWD BEARING MAIN DOOR ON RH MAIN LANDING GEAR. MAINTENANCE REPLACED AND DRILLED NEW HINGE FITTING ASSY LOCATED AT MAIN DOOR ON RH MAIN LANDING GEAR IAW AIRBUS CMM 52-81-18 AND A319 SRM 51-44-11-801.SDR QXEA2025051200178O-Ring · leakingRIGHT INBOARD BRAKE TOP FASTENER LEAKING FLUID. FLUID SPRAYING FROM THE TOP OF FITTING. REMOVED FROM SERVICE. INSPECTED AND FOUND BLEEDER VALVE ADAPTER FITTING LEAKING. REMOVED BLEEDER VALVE ASSEMBLY IAW AMM 32-49-11-000-804-A. REPLACED ADAPTER O-RING WITH NEWSDR DALA2025051203671Angle · corrodedCORROSION ON CHORD ANGLE FROM STA 360 TO STA 291 BTW RBL 57 AT (FLOOR STRUCTURE) W1. CHORD ANGLE BTW STA 360 TO STA 251, RBL 57 AT (FLOOR STRUCTURE) W1 WAS REPLACED PER B737-800 SRM 51-40-02-0G PAR 4. AND 51-40-02-0G PAR 7.D.SDR DALA2025051203670Skin · corroded(LOG 0959151) SECONDARY FINDING CORROSION ON INTERNAL LOWER SKIN LOC BS390 AND STR 28L. COMPLIED WITH ER/A 625651-14 REV ORIGINAL.SDR DALA2025051203669Angle · corroded(LOG 0958988) CORROSION SUPPORT ZEE LOCATED BTW STA 727 TO STA 767 AND STR 25R AFT CARGO COMPARTMENT. REPLACED SUPPORT ZEE LOCATED BTW STA 727 TO STA 767 AND STR 25R AFT CARGO COMPARTMENT AS PER B737-800 SRM 51-40-02-0G, DWG 146A7502.SDR DALA2025051203675Skin · damagedSHIP 3407 TOOLING DAMAGE AT STR 7 RH. CORRECTIVE ACTION: REPAIRED PER PRI 626125 REV 0, REV 1 AND FINAL ER/A 626125-14 REV ORIG. (0958193)SDR JJBA20250512047Light · inoperativeEMERGENCY LIGHT UNDER FLIGHT DECK DOOR INOPERATIVE. REMOVED AND REPLACED EXIT SIGN. OPS CHECK SAT.SDR DALA2025051203657Sign · detachedSHIP 6712 EXIT SIGN AT 2R FELL DURING LANDING. CORRECTIVE ACTION: RESECURED EMERGENCY EXIT SIGN. OP CHECK GOOD. (5752518)SDR DALA2025051203656Handle · overrotatedSHIP 0694 -FCNT/DE- DUE TO TRAILING EDGE FLAP DISAGREE DUE TO FLAP HANDLE OVERSHOOT. CORRECTIVE ACTION: T/S PER FIM. RAN FLAPS. OPERATION NORMAL.SDR DALA2025051203655Placard · out of positionSHIP 6810 ENTRY DOOR ARMING LEVER HARD TO OPERATE / LOCATIONS:601. DISARMED PLACARD DOES NOT DISPLAY PROPERLY. CORRECTIVE ACTION: REAJUSTED PLACARD LOCATION AND READJUSTED ENTRY DOOR ARMING LEVEL @ LOCATION 601. CHK NML. REF B757 AMM 52-10. (0958166)SDR DALA2025051203653Track · fodSHIP 5640 2L DOOR WON'T CLOSE. CORRECTIVE ACTION: CLEANED TRACK OF DEBRIS REF B757 AMM 52-12. OPS CK GOOD. (6986542)SDR DALA2025051203651Actuator · damagedSHIP 5645 AT FL250, 40 MINUTES INTO THE FLIGHT, PACKS PRODUCED ONLY HOT AIR (MAX CABIN TEMP 77*F). COLD AIR AT 12,000 AND SMOKE ODOR AT 6,000. CORRECTIVE ACTION: T/S PER B757 FIM 21-00-01 PB301. FOUND LEFT PACK RAM AIR INLET DOOR ACTUATOR IS DAMAGED AND RAM AISDR FDEA202505100745Slide · failedRAMP PERSONNEL OPENED L1 AFTER DOORS WERE ARMED AND THE SLIDE FELL OUT OF THE DOOR WITHOUT INFLATING. L1 DOOR ASSIST BOTTLE BLOWN, SLIDE DID NOT DEPLOY. REPLACED THE L-1 EMERGENCY POWER RESERVOIR AND THE L1 SLIDE ASSYSDR FDEA202505100744Seat Track · damagedREF TO WRI 25-50/1414, MAIN DECK SEAT TRACK BEAM RBL11 BROKEN AT STA610 - STA632 REPAIRED THE BROKEN SEAT TRACK BEAM RBL11 AT STA610 - STA632 PER B767 SRM53-00-52-2R REPAIR 9 & EA: H-5310-T0383377 P1, TITLE: FUSELAGE - MAINFRAME - SECTION 43 MAIN DECK FLSDR UIEA2025051200598Beam · corrodedCORROSION - BEAM L/H WING L/E LOWER PNL FWD SUPPORT BEAM INNER FACE ILES 757.(<P>1. BLENDED OUT THE DAMAGE AREA IAW SRM 51-10-02-0G-0 REV 60. 2. PFM NDT INSP REFER TO JOB CARD ATTACHING SHEET 0473658. 3. MEASURED REWORK AREA D= 0.001", L= 0.7", W= 0.5", IT WASSDR UIEA2025051200599Beam · corrodedCORROSION - BEAM L/H WING OUTBD L/E LOWER PNL FWD SUPPORT BEAM INNER FACE OLES 1552.(<P>1. BLENDED OUT THE DAMAGE AREA IAW SRM 51-10-02-0G-0 REV 60. 2. PFM NDT INSP REFER TO JOB CARD ATTACHING SHEET 0473659. 3. MEASURED REWORK AREA D= 0.003", L= 0.5", W= 0.4",SDR UIEA2025051200600Beam · corrodedCORROSION - BEAM L/H WING OUTBD L/E LOWER PNL FWD SUPPORT BEAM INNER FACE OLES 1497.(<P>1. BLENDED OUT THE DAMAGE AREA IAW SRM 51-10-02-0G-0 REV 60. 2. PFM NDT INSP REFER TO JOB CARD ATTACHING SHEET 0473660. 3. MEASURED REWORK AREA D= 0.003", L= 0.45", W= 0.4"SDR UIEA2025051200601Battery Pack · inoperativeFOUND EMER LIGHT POWER PACK INOP, M14533, M14532, X317.(<P>1. REPLACED M14333, M14532, X317 BATTERIES AND LIGHT ASSY IAW AMM 33-51-04-902-001-001 & AMM 33-51-06-004-046. 2. PERFORMED LIGHT TEST AND THE RESULT WAS SATISFACTORY.</P>)SDR AALA202505120313Vapor Barrier · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER, LEFT MLG WHEEL WELL, AT STA 663.75, LBL 31.83. PREVIOUS REPAIR DISBONDED. REPAIRED VAPOR BARRIER PER AARD 57-10-10-9.SDR CALA2025051204617Fuse · blownFLOOR PROXIMITY EMERGENCY LIGHTS INOP ROWS 22-31. REPLACED BATTERY M1670 & M1672. POWER SUPPLY M1672 FUSES CHECK OK. REPLACED BATTERY M1672 POWER SUPPLY. NO HELP. REINSTALLED EQUIPMENT IN ORIGINAL LOCATIONS. REF WDM 33-51-22-3.1 REF SSM 33-51-21-104.1 & WDM 3SDR CALA2025051204616Guard · faultyEMER LIGHTS GUARD WHEN CLOSED TURNS LIGHT SWITCH TOGGLE TO OFF POSITION. FOUND SWITCH GUARD NOT PULLING SWITCH FROM OFF TO ARMED WHEN SELECTED DOWN REPLACED SWITCH GUARD OPS NORMALZ.PARTS USED: 25-3351-3-0021, QTY :1SDR CALA2025051204605Battery Pack · inoperativeEMERGENCY BATTERY PACK M1694 DOES NOT CHARGE. (REF: AAR NR 1000034040) REMOVED AND INSTALLED NEW POWER SUPPLY BATTERY PACK M1694 IAW B737 AMM 33-51-06-960-805 OP TEST GOOD (WORK ACCOMPLISHED BY V937546 AND AAR QC A-11 V931821) SDR IS COMPLIED WITH. SDR #1555SDR CALA2025051204604Battery Pack · inoperativeEMERGENCY BATTERY PACK M1672 DOES NOT CHARGE. (REF: AAR NR 1000034039) REMOVED AND INSTALLED NEW POWER SUPPLY BATTERY PACK M1672 IAW B737 AMM 33-51-06-960-805 OP TEST GOOD (WORK ACCOMPLISHED BY V937546 AND AAR QC A-14 V935540) REMOVED AND REPLACE POWER SUPPLY