Service difficulty reports
1,773,593 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2025040802740Cover · looseSHIP 6716 EMERGENCY EXIT SIGN COVER LOOSE / LOCATIONS:608. CORRECTIVE ACTION: RESECURED ROW 25/26 COVER UNDER EXIT SIGN. (0897561)SDR DALA2025040802736Indicator · out of limitsSHIP 6710 PRESSURE INDICATOR OUT LIMITS (WHITE NEEDLE ON RED RANGE) ON EMERGENCY SCAPE SLIDE OF PASSENGER DOOR L4. CORRECTIVE ACTION: SLIDE EVAC. DOOR 4L WAS REMOVED AND SERVICEABLE SLIDE INSTALLED UNDER AMDS 2566-9001-4L (REF LOG 0891836). 0897674)SDR DALA2025040802735Stringer · corrodedSHIP 685 CORROSION ON STGR 26RH BTW STA 860 TO STA 840 AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00155: CORROSION LEVEL 2; STGR 26RH BTW STA 860 TO STA 840 AT FWD CARGO COMPARTMENT WAS REPAIRED PER B757-200 SRM 53-00-03-2R REPAIR 1. (0897658)SDR DALA2025040802734Fitting · corrodedSHIP 685 A.D.//A.A. DISCREPANCIES ON OPEN HOLES FROM LH ENG DRAG FTG CLAMP-UP AS FOLLOW: HOLE # 2 CORROSION AND SCRATCHES ON FITTING AND SKIN BTW 8-11 O CLOCK POSITION, HOLE # 3 CORROSION ON FITTING AND SKIN BTW 1-4 O CLOCK POSITION, HOLE # 4 CORROSION ON FITTSDR DALA2025040802733Drag Fitting · corrodedSHIP 685 A.D.//A.A. DISCREPANCIES ON OPEN HOLES FROM LH ENG DRAG FTG CLAMP-UP AS FOLLOW: HOLE # 11 CORROSION ON FITTING AND SKIN BTW 4-7 O CLOCK POSITION, HOLE # 12 CORROSION ON FITTING AND SKIN BTW 8-11 O CLOCK POSITION, HOLE # 13 CORROSION ON FITTING BTW 9- SDR DALA2025040802732Strap · crackedSHIP 6710 CRACK ON STABILIZER STRAPS (2 EAS) STA 365.25 AND BL 0 ALSO STA. 395 AND LBL 24 AT E&E BAY. CORRECTIVE ACTION: SUMMARY OF NRC 00304, STABILIZER STRAPS (2 EAS) STA 365.25 AND BL 0 ALSO STA. 395 AND LBL 24 AT E&E BAY WERE REPAIRED PER B757- 200 SRM 53-SDR DALA2025040802731Frame · crackedSHIP 685 AD / A.A. CRACK OF 0.187" LENGTH WAS FOUND ON RH FUSELAGE FRAME INNER-CHORD STA. 1640 LOCATED AT SECOND FASTENER BELOW INTERCOSTAL STRAP S-14. CORRECTIVE ACTION: SUMMARY OF NRC 00177: FUSELAGE MAIN FRAME STA 1640 RH WAS REPAIRED PER ER/A 591892-14AD RSDR DALA2025040802730Deck Plate · corrodedSHIP 6710 CORROSION PREVIUOS REPAIR ON DECK PLATE FROM STA 1705 TO 1720 RBL 15 TO LBL 15 AT PASSENGER CABIN. CORRECTIVE ACTION: SUMMARY OF NRC 00496 CORROSION LEVEL 2, PREVIUOS REPAIR ON DECK PLATE FROM STA 1705 TO 1720 RBL 15 TO LBL 15 AT PASSENGER CABIN WAS SDR DXTA2025040502954Switch · failedEMERG LIGHT SWITCH: EMER LIGHTS DO NOT COME ON WHEN SELECTING EMER SWITCH FROM OFF TO ON WITH BATTERY SWITCHES IN THE OFF POSITION. WE CHARGED THE BATTERIES FOR 30 MINS WITH THE SWITCH OFF AND THE LIGHTS WOULD STILL NOT COME ON.SDR AALA202504081002Light · inoperativeAIRCRAFT WAS NOT GROUNDED: SEAT 9C EMERGENCY EXIT LIGHT IS INOP. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR REXA2025040800402Battery Pack · no testDURING LINE CHECK FOUND SEVERAL FWD EMERG ENTRANCE LIGHTS INOP. TROUBLESHOT AND FOUND BATTERY PACK PS35 INOP. REMOVED & REPLACED BATTERY IAW AMM 33-51-17 PERFOMRED OPS TEST IAW AMM 33-51-17. OPS TEST GOOD.SDR AALA202504085401Skin · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN LEFT HAND HORIZONTAL STABILIZER LOWER SKIN LOCATED AT STABILIZER STA 129.50, 9 INCHES FROM FRONT SPAR. REPAIRED SKIN PER SRM 55-10-01-2R-11.SDR AALA202504086073Skin · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN LEFT HAND HORIZONTAL STABILIZER LOWER SKIN LOCATED AT STABILIZER STA 157.90, 16 INCHES FROM AFT SPAR. REPAIRED SKIN PER SRM 55-10-01-2R-11.SDR DALA2025040802718Frame Splice · damaged(LOG 0896413) DURING HCK AT QRO, WHILE PERFORMING REPETITIVE INSPECTIONS ER/A 475941-14 REV. D SECTION II AND SECTION III, ONE (1EA.) ELONGATED HOLE WAS FOUND AFFECTING THE UPPER FRAME REPAIR SPLICE AT STA 727G BETWEEN S-18L AND S-19L (SECTION II UPPER SPLICE SDR DALA2025040802717Battery Pack · inoperative(LOG 7180934) EMERGENCY LIGHTS FROM 11DEF TO 17DEF INOP. REMOVED AND REPLACED BATTERY PACK AT ROW 11DEF - REFERENCE B737 AMM 33-51. OPS CHECK GOOD.SDR UIEA2025032300377Retainer · corrodedCORROSION ON THE PLATE LOCATED IN THE FRAME UPPER PART (INNER STRUCTURE) WHICH IT IS SUPPORTING THE ACCESS PANEL 447BL, RIGHT ENGINE, AFT NACELLE STRUT FAIRINGS.(<P>PLATE OF THE ACCESS PANEL 447BL WAS REPLACED IAW SRM 51-10-02-0G-0 PAR 9 REV 52. NO FURTHER DESDR UIEA2025032300378Retainer · corrodedCORROSION ON THE PLATE LOCATED IN THE FRAME UPPER PART (INNER STRUCTURE) WHICH IT IS SUPPORTING THE ACCESS PANEL 447BR, RIGHT ENGINE, AFT NACELLE STRUT FAIRINGS.(<P>PLATE OF THE ACCESS PANEL 447BR WAS REPLACED IAW SRM 51-10-02-0G-0 PAR 9 REV 52. NO FURTHER DEFSDR UIEA2025032300379Skin · gougedGOUGE AT INTERIOR SKIN OF FWD CARGO DOOR LWR FWD FRAME, STA 494.(<P>REWORKED AND INSPECTED PER TRE6752058 (BOEING MESSAGE CMA-TLS-25-0024). NO FURTHER DEFECTS NOTED.</P>)SDR UIEA2025032700392Computer · leakingELEVATOR FEEL COMPUTER, WITH HYDRAULIC LEAK.(<P>ELEVATOR FEEL COMPUTER HYDRAULIC LINES WERE RE-TORQUED IAW AMM 27-31-19-424-015 REV. 144 22DEC24. TORQUE APPLIED 270 IN/LB AND 170 IN/LB, TORQUES WRENCH DATA S/N: 0422127314 D/D: 17SEP25 AND S/N: 1123126519 D/D: SDR UIEA2025040100423Skin · crackedLH SIDE, FORWARD ENTRY DOOR CUTOUT AFT LOWER CORNER, WAS FOUND CRACK INDICATION, ON OPEN HOLE # 4 POSITION 5 O'CLOCK AT SKIN AND 10 O'CLOCK POSITION BEAR STRAP.(<P>LH SIDE, FORWARD ENTRY DOOR CUTOUT AFT LOWER CORNER, ON OPEN HOLE # 4 POSITION 5 O'CLOCK AT SKINSDR UIEA2025040100424Skin · crackedRH SIDE, FORWARD SERVICE DOOR CUTOUT AFT LOWER CORNER, WAS FOUND CRACK INDICATION, ON OPEN HOLE # 4 POSITION 1 O'CLOCK AT SKIN APPROX.(<P>RH SIDE, FORWARD SERVICE DO OR CUTOUT AFT LOWER CORNER, ,ON OPEN HOLE # 4 POSITION 1 O'CLOCK AT SKIN CRACK WAS REPAIRED IASDR UIEA2025040100425Torsion Box · corrodedCORROSION ON TORSION BOX TOP SKIN BTW RBL 13.83 AND RBL 41.50, STGR 3 AT HORIZONTAL STABILIZER CENTER SECTION.(<P>ON TORSION BOX TOP SKIN BTW RBL 13.83 AND RBL 41.50, STGR 3 AT HORIZONTAL STABILIZER CENTER SECTION, CORROSION LEVEL 2 WAS REPAIRED IAW TRE6755083SDR UIEA2025040100426Fuel Cell · leakingFUEL LEAK AT LOWER SIDE AREA OF LT WING LWR REAR SPAR SPLICE FITTING.<BR>(<P>LOWER SIDE AREA OF LT WING LWR REAR SPAR SPLICE FUEL LEAK WAS REPAIRED AND TEST WAS SATISFACTORY IAW AMM 28-11-00-308-013 REV 144 22/DEC/24. NO FURTHER DEFECTS NOTED.</P>)SDR UIEA2025040300428Blocker Door · crackedENG. 1, RIGHT T/R BLOCKER DOOR NO. 9 WITH A CRACK.(<P>ENG. 1, RIGHT T/R BLOCKER DOOR NO. 9 WAS REPLACED IAW AMM TASK 78-31-14-404-008-H00. NO FURTHER DEFECTS NOTED.</P>)SDR UIEA2025040300429Apu · inoperativeAPU INOP (AUXILIARY POWER UNIT) ER OPERATIONS NOT ALLOWED (NOTIFY DISPATCH) R60).(<P>APU INOP (AUXILIARY POWER UNIT) ER OPERATIONS NOT ALLOWED (NOTIFY DISPATCH) R60) WAS REPLACED WITH TASK CARD 8027 A-49-999-00-01. NO FURTHER DEFECTS NOTED.</P>)SDR UIEA2025040300430Seal · brokenWING RH, BROKEN SEAL ON ACCESS PANELS 661 LB AND 661 CB.(<P>WING RH SEAL WAS REPLACED ON ACCESS PANEL 661LB, WING RH SEAL WAS REPLACED ON ACCESS PANEL 661CB IAW SRM 51-10-02-0G-0 PAR 9. NO FURTHER DEFECTS NOTED</P>)SDR UIEA2025040300431Metering Valve · leakingLH WHEEL WELL AREA FWD BULKHEAD LH BRAKE METERING VALVE ASSY WITH HYDRAULIC LEAK.(<P>LH BRAKE METERING VALVE ASSY WAS INSTALLED IAW 32-41-02-424-002-003. STEP D1 STEP D10 TORQUE APPLIED S/N 0422127314 DUE DATE 17SEP25, TORQUE APPLIED 85 IN LBS, 140 IN LB, 200 SDR UIEA2025040300432Pca · leakingRH WING, REAR SPAR, INBOARD AILERON, BOTH PCA´S WITH HYDRAULIC LEAK.(<P>AILERON PCAS (2 EAS) WERE REPLACED (SN: 1133 PN: 282800-1009 & SN: 1196 PN: 282800-1009). CHECKED FOR LEAKS & NO LEAK FOUND. ADJUSTMENT AND TESTS WERE SATISFACTORY. ALL WORKS IAW AMM 27-11SDR UIEA2025040400433Union · brokenRIGHT ENGINE STRUT 2 AFT NACELLE STRUT FAIRINGS IN ACCESS PANEL 447BL INTERNAL PART IN HYDRAULIC SHUT OFF VALVE WITH BROKEN CONNECTOR.(<P>CONNECTOR OF HYDRAULIC SHUTOFF VALVE AND BACKSHELL WERE REPLACED (PN: BACC63BW14SC5S & PN: BACC10HV14) INSTALLATION TEST WSDR UIEA2025040400434Pbe · leakingWING LH, INBOARD AILERON, BOTH PCA'S WITH LEAK.(<P>BOTH PCA'S, WERE REPLACED, ADJUSTED AND TESTED. (SN: 0683 PN: 282800-1011 & SN: 280 PN: 282800-1007) TEST WAS SATISFACTORY AND NO LEAK FOUND. ALL WORK IAW AMM: 27-11-48-022-003, AMM 27-11-48-422-040 AND 27-11-SDR UIEA2025040400436Fuse · leakingHYDRAULIC LEAK AT RH ANTISKID MODULE FUSE.(<P>IN RH ANTISKID MODULE FUSE WAS REPLACED IAW AMM 32-42-02-404-014, CHECK FOR LEAK, NO LEAK FOUND, OPERATION OF BRAKES WAS SATISFACTORY, IAW AMM 32-42-03-404-033.</P>)SDR UIEA2025040400437Seal · brokenLH WING ACCESS PANEL 561BB WITH BOTH BULB SEAL BROKEN.(<P>BROKEN SEAL REPLACED AND CORRECTLY INSTALLED PER SRM 51-10-02-0G-0 PARA 9 REV 51. NO FURTHER DEFECTS NOTED.</P>)SDR UIEA2025040400439Pad · brokenLEFT WING LOWER SURFACE AREA MIDBODY INTEGRAL JACK PAD BROKEN.(<P>LEFT WING LOWER SURFACE AREA MIDBODY INTEGRAL JACK PAD WAS REPLACED IAW AMM 57-54-06-914-002 REV 144 DATE 22DEC24. NO FURTHER DEFECT NOTED.</P>)SDR UIEA2025040400440Proximity Sensor · damagedBROKEN TAG WASHER SUPPORT ON INBOARD AUX TRACK AT SLAT NO. 9.(<P>LEADING EDGE SENSOR SWITCH ON INBOARD AUX TRACK AT SLAT NO. 9 WAS REPLACED IAW AMM 27-88-01-902-001 REV 144 22DEC24. NO FURTHER DEFECTS NOTED.</P>)SDR UIEA2025040400441Cover · dentedDURING RAM AIR TURBINE DEPLOYMENT TEST BY TASK CARD 8017-0101, FOUND A DENT ON RAM AIR TURBINE COVER SURFACE; IT WAS EVALUATED AND FOUND OUT OF LIMITS. L= 2.400 IN, W= 1.100 IN, D= 0.075 IN.(<P>N/R 00278 THE COVER WAS REMOVED FROM THE RAM AIR TURBINE IAW CMM 2SDR UIEA2025040400442Skin · dentedVERTICAL STABILIZER LH PANEL ASSEMBLY OUTER SKIN WITH DENT.(<P>DENT ON VERTICAL STABILIZER, LH PANEL ASSEMBLY, OUTER SKIN, WAS EVALUATED AND FOUND WITHIN ALLOWABLE DAMAGE LIMITS I.A.W. SRM 55-30-01-1A-1 AD.1 FIG. 101, DETAIL III. REV. 52 15APR25. DENT DOT 9025SDR UIEA2025040400443Skin · debondedLH VERTICAL STABILIZER SKIN PANEL BTW FSS 270.784 TO FSS 118.75 PANEL WITH DISBONDED.(<P>LH VERTICAL STABILIZER SKIN PANEL WAS REPLACED IAW SRM 51-10-02-0G-0 PAR 9 REV 52 15-APR-25. NO FURTHER DEFECTS NOTED.</P>)SDR UIEA2025040400444Pump · faultedLH WING THE FUEL BOOST PUMP LH FWD, TEST OPERATIONAL NOT SATISFACTORY. LT FWD BOOST PUMP LIGHT IN PANEL "P5" WAS INSTALLED CORRECTLY. IAW SWPM 20-84, REV 88, DATE 15-FEB-2025. TEST RESULT SATISFACTORY.SDR JJBA20250408037Muffler · splitSMELLED SMOKE IN COCKPIT ON TAKE OFF. NO EICAS MESSAGES. ON TAKEOFF NOTICED THE SMELL OF SMOKE. APU BLEED WAS ON. BOTH PACKS WERE ON. #1 AND #2 ENGINES BLEEDS OFF. INITIAL SMELL WAS LIKE A SANDWICH OR FOOD THEM SMELL TURNED TO ELECTRICAL. NO VISIBLE SMOKE. FLASDR COEA2025040801738Exhaust Duct · crackedWO 266635 NR 10 MINOR REPAIR/DISCREPANCY: #2 ENGINE INBOARD EXHAUST CRACKED. CORRECTIVE ACTION: INSTALLED A SERVICEABLE #2 ENGINE INBOARD EXHAUST IAW C408 MM 78-10-05.SDR CALA2025040803643Megaphone · faultedDOOR SEAL NOISE FROM 1L TALKED TO CREW FOUND NOISE WAS NOT FROM DOOR BUT FROM MEGAPHONE. MEGAPHONE WAS GOING OFF AND NOT SHUTTING OFF. REPLACED MEGAPHONE PER AMM 25-64-00. NEW MEGAPHONE OPERATED NORMALLY ON GROUND.SDR CALA2025040803637Fuel Cap · missingPDA 2 FUELING VENDOR REPORTS FUEL CAP MISSING ON ARRIVAL FUELER FOUND FUEL CAP MISSING. PERFORMED GVI, NO DEFECTS NOTEDSDR CALA2025040803636Slide · unsecureDOOR 1L NEEDS EMERGENY SLIDE MATERIAL RESTOWED. RESTOWED DOOR L1 SLIDE Z FOLD I.A.W AMM 25-66-01-409-804. A/C OK FOR SERVICE.SDR CALA2025040803632Girt Bar · unsecurePOTENTIAL ESCAPE SLIDE ISSUE. EXCESSIVE MATERIAL SHOWING ATTACH ED TO GIRT BAR. DOOR 1R. SECURED EXCESSIVE MATERIAL ON GIRT BARSDR CALA2025040803631Slide · no discrepancy2R DOOR SLIDE PRESS NEEDLE IN RED. VISUALLY INSPECTED 2R DOOR SLIDE NEEDLE IS WITHIN THE GREEN PARAMETERS OF THE PRESSURE GAGE AND IS WITHIN LIMITS WITH REF TO AMM 25-66-01-200-801 ESCAPE SLIDE PACK INFLATION CYLINDER CHECK.SDR CALA2025040803630Oven · inoperativeOVEN 105 R11 INOP REQUEST DEFERRAL OF OVEN 105, NO POWER TO OVEN, CB PULLED AND COLLARED NOC DESK: 319 NAME: DATE: 05-APR-25- OK TO APPLY MEL 2522AD...TOMC SMITH OVEN 105 PLACED ON DEFERRAL WRONG OVEN WAS SENT TO STATION ADDED MATERIAL LIST PART NIS RR OVEN SDR CALA2025040803629Girt Bar · unsecureR1 DOOR SLIDE HAS EXCESS MATERIAL HANGING DOWN LOW BELOW THE DO OR SECURED R1 GIRT NO DEFECTS NOTED AT THIS TIME REF AMM TASK 25-66-01-200-802SDR CALA2025040803628Proximity Sensor · faultedDOOR AFT CARGO IND STATUS PERFORMED FIM 52-37 TASK 807. REPLACED CLOSED PROXIMITY SENSOR S52045. TEST PASSED.SDR CALA2025040803627Girt Bar · detachedL1 DOOR JAM JETBRIDGE WAS POSITION HIGHER THAN USUAL, LEFT SIDE OF GIRT BAR CAME OFF, RESECURED GIRT BAR DOOR WAS FOUND OPERATIONAL. NO JAMS REF AMM 52-11-00SDR DALA2025040802702Frame · corrodedCORROSION ON FRAME STA Y=870 L29L TO L29R. ORIGINAL THICKNESS IS 0.063IN AND MINIMUM REMAINING THICKNESS IS 0.029IN THEREFORE AREA IS OUT OF LIMITS PER B717-200 SRM 53-00-00-1A PAR 4C (2) FIG 103. SUMMARY OF NRC 00663: CORROSION LEVEL 2. FRAME STA Y=870 L29L T