Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026040702221Wedge · debondedA.D. A.A. / DISBOND WAS FOUND OF 2.500 IN X 2.000 IN, ON LE SLAT 4 TRAILING EDGE WEDGE UPPER SURFACE AT OSS 337.5. IN REFERENCE TO TASK CARD 5740-01145-05D, JOB 223-0001, STEP 5. LE SLAT 4 TRAILING EDGE WEDGE UPPER SURFACE AT OSS 337.5. WAS REPAIRED PER B757-SDR ABXA20260406153Fire Warning · illuminatedDURING MAINTENANCE PRE-FLIGHT, EICAS FWD CARGO DET 2 MSG. MAINTENANCE DEFERRED PER B767 MEL 26-16-1-2, MAINTEMANCE PROCEDURES COMPLIED WITH, PLACARDS INSTALLED AND MBCB 04/16/2026, AIRCRAFT REMAINS ETOPS 180. A/C RETURNED TO SERVICE.SDR DALA2026040702212Seat Track · corroded"CORROSION" ON SEAT TRACK AT FR74, RBL24, WL 151. REMOVED DAMAGED SEAT TRACK IN PASSENGER COMPARTMENT FROM FR 61 TO FR 74 RBL 24 WL 151 AND REPLACED PER A220 ASRP BD500-AQ-J51- 42-20-00AAA-078A-A AND BOMBARDIER PL C01342701 REV-G. (LP# 1531193)SDR DALA2026040702208Oxygen Mask · unwanted deployCREW REST BUNK 2 AND BUNK 3 OXYGEN MASK PANEL OPEN AND DEPLOYED. REPLACED O2 MASK MODULES PER A330 AMM 35-21. OK FOR SERVICE. (1531390) AIRCRAFT WAS GROUNDED.SDR DALA2026040702205Seat Track · corrodedCORROSION FOUND ON SEAT TRACK -Y2462 FR37.5 AT FACTORY SPLICE LOCATION FWD END OF SEAT TRACK. REPLACED SEAT TRACK PER A330 SRM 51-42-11. (1531114) AIRCRAFT WAS GROUNDED.SDR DALA2026040702204Seat Track · corrodedCORROSION FOUND ON SEAT TRACK -Y2462 FR37.5 AT FACTORY SPLICE LOCATION AFT END OF SEAT TRACK. REPLACED SEAT TRACK PER A330 SRM 51-42-11. (1531111) AIRCRAFT WAS GROUNDED.SDR AALA202604074515Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: FLASHLIGHT AT DOOR 4R NOT WORKING. MAINTENANCE REPLACEMENT FLASHLIGHT BATTERY AT FLASHLIGHT DOOR 4R IAW AMM 25-64-00 CKD OK FOR SVC.SDR SIMA20260406001Light · inoperativeEMERGENCY PHOTOLUMINESCENT STRIP INDICATOR STRIP LIGHTS AT SEATS [23FD-21FD], [1FD-2FD], [1A-2A], AND ENTRANCE/GALLEY INOP RAR EMERGENCY PHOTOLUMINESCENT STRIP INDICATOR STRIP LIGHTS AT SEATS [23FD-21FD], [1FD-2FD], [1A-2A], AND ENTRANCE/GALLEY IAW ERJ 175 AMMSDR SIMA2026040600002Battery Pack · failedRH AFT EMERGENCY LIGHTING INOP. RAR RH AFT EMERGENCY LIGHTING POWER UNIT IAW AMM 33-50-01. OPC GOOD.SDR UIEA2026040600131Doubler · damagedDEVIATION - DURING PERFORM SB 4453A749 PART 12 L/H DOUBLER HAVE 1 EA EXISTING HOLE SHORT E/M AND FIGURE 27 NOT SHOW FL 49. ACCOMPISHED EI T2026A53M-507 REV 1 AND EI T2026A53M-530 REV 1.. JOB COMPLETED.SDR UIEA2026040600132Fitting · damagedDEVIATION - DURING PERFORM SB 4453B761 PART 1-2, R/H UPPER SPLICE FITTING EXISTING HOLE IS 0.341". ACCOMPLISHED EI T2026A53M-528 REV 1 AND EI ATTACHED TO W/O 12176703 (727). JOB COMPLETED.SDR UIEA2026040600133Fitting · crackedCRACKED DURING PERFORM SB 4453B761 PART 1-2, RT UPPER SPLICE FITTING HAVE 1 HOLE CRACK. ACCOMPLISHED EI T2026A53M-528 REV 1, AND DWG 65B02705, SH 4 REV D, SH 6 REV C, AND DWG 65B02509 SH 3 REV R. JOB COMPLETED.SDR UIEA2026040600134Seat Track · crackedCRACKED M/D SUBSTITUTE SEAT TRACK AT BS 1480, LBL 75.92. REMOVED AFFECTED FASTENERS TO GET ACCESS IAW SRM 51-40-02-0G-0 REV 106. REPAIR DAMAGE AREA IAW W/S 60149 (SRM 53-00-52-2R-13 REV 106) INSTALLED FASTENERS IAW SRM 51-40-02-0G-0 REV 106 AND DWG 65B38751SDR UIEA2026040600135Seat Track · crackedCRACKED M/D SEAT TRACK AT BS 1500, LBL 98.58. REMOVED DAMAGED PARTS IAW SRM 51-40-02-0G-0 REV 106. ACCOMPLISHED WORK SHEET 60150 AND EI T2026A53M-562 REV 1 AND DWG 65B38751 SH 62 REV A, SH 62 REV - AND DWG 144U0802 SH3 REV B AND SRM 53-00-57-2R-6 REV 106. SDR UIEA2026040600136Skin · corrodedCORRODED SKIN, LT MLG FWD BULKHEAD AT CENTER WING TANK JETTISON PUMP, LEFT M224, BONDING JUMPER ATTACHED. ACCOMPLISHED THE EI T2026A57M-398 REV 5. CONDITION CHECK NORMAL AND JOB COMPLETED.SDR UIEA2026040600137Skin · corrodedCORRODED SKIN, RT MLG FWD BULKHEAD AT CENTER WING TANK JETTISON PUMP, LEFT M225, BONDING JUMPER ATTACHED. REPAIR THE CORROSION AREA IAW EI T2026A57M-397 REV 3 SEQUENCE D. ACCOMPLISHED EI T2026A57M-397 REV 4. CONDITION CHECK NORMAL AND JOB COMPLETED.SDR UIEA2026040600139Channel · crackedCRACKED CHANNEL, FOUND MAIN ENTRY DOOR 1 UPPER MAIN SILL NEAR STA 460 S16L. REMOVED DAMAGED PARTS IAW SRM 51-40-02-0G-0 REV 106. FABRICATED NEW PARTS IAW EI T2026A53M-582 REV 0. INSTALLED FABRICATED PARTS IAW SRM 51-40-02-0G-0 REV 106, AND DWG 65B01916 SH SDR UIEA2026040600140Frame · crackedCRACKED FRAME AND CHANNEL, BS 820 S9-10R. REMOVED AFFECTED FASTENERS IAW SRM 51-40-02-0G-0 REV 106. REPAIRED DAMAGE AREA IAW W/S 60165 AND SRM 53-20-07-2R-2 REV 106. INSTALL FASTENERS IAW SRM 51-40-02-0G-0 REV 106 AND DWG 142U1312 SHEET 215 REV B AND DWG 1SDR UIEA2026040600141Tension Tie · crackedCRACKED TENSION TIE, STA 820 S9-10R. REMOVED AFFECTED FASTENERS TO GET ACCESS IAW SRM 51-40-02-0G-0 REV 106. REPAIRED DAMAGE AREA IAW W/S 60174 AND W/S 60169 AND DWG 142U1923 SHEET 46 REV D. INSTALL FASTENERS IAW SRM 51-40-02-0G-0 REV 106 AND DWG 142U1023 SDR UIEA2026040600142Frame · crackedCRACKED FRAME, BS 840 S-9-10R. REMOVED AFFECTED FASTENERS TO GET ACCESS IAW SRM 51-40-02-0G-0 REV 106. PERFORMED EI T2026A53M-586 REV 0. INSTALLED FASTENERS IAW SRM 51-40-02-0G-0 REV 106 AND DWG 142V0840 SHEET 106 REV -. ACCOMPLISHED EI T2026A53M-586 REV 1SDR UIEA2026040700145Frame · crackedCRACKED FRAME, BS 860, S9 -10R. REMOVED AFFECTED FASTENERS TO GET ACCESS IAW SRM 51-40-02-0G-0 REV 106. PERFORMED EI T2026A53M-590 REV 0. INSTALLED FASTENERS IAW SRM 51-40-02-0G-0 REV 106 AND DWG 142U0860 SHEET 106 REV -. ACCOMPLISHED EI T2026A53M-590 REV SDR UIEA2026040700147Retainer · corrodedCORRODED RETAINER, RT WLG W/W UNDERWING REAR SPAR FAIRING AND VAPOR BARRIER CORNER AREA SEAL. REMOVE DAMAGED PART IAW SRM 51-40-02-0G-0 REV 106. INSTALL NEW PART IAW SRM 51-40-02G-0 REV 106 AND DWG 65B11631 SH 2 REV J. JOB COMPLETED AND CONDITION CHECK NORMSDR UIEA2026040700148Bracket · corrodedFOUND NR 1 PACK BRACKET CORROSION AT #1 COMPRESSOR BYPASS VALVE OUTBD SIDE AT STA 1028.86 LBL 57.7. REMOVED DAMAGED PARTS IAW SRM 51-40-02-0G-0 REV 106. 2. INSTALL NEW PARTS IAW SRM 51-40-02-0G-0 106 AND BOEING DWG 65B10538 SHEET 14 REV B. 3.SDR SCNA20260407150Temp Strip · failedFWD LAV TEMERATURE STRIP WAS DARK ON 200 F CIRCLE . INSPECTED FWD LAV NO EVIDENCE OF FIRE, R & R TEMPETURE STRIP IAW AMM 26-24-01 .SDR SWAA2026040786757Charger · inoperativeFOUND RH FWD OWE (EXTERIOR) LAMP INOP<[01] REPLACED BOTH EMER CHARGER ASSY (M1676) AND BATTERY PACK WITH NEW; ALL EMER LIGHTS OPS CHECK GOOD. WORK DONE PER 33-51-06.;[02] REPLACED BOTH EMER CHARGER ASSY (M1676) AND BATTERY PACK WITH NEW; ALL EMER LIGHTS OPS CHSDR SWAA2026040787174Battery Pack · inoperativeFOUND RH FWD OWE (EXTERIOR) LAMP INOP<[01] REPLACED BOTH EMER CHARGER ASSY (M1676) AND BATTERY PACK WITH NEW; ALL EMER LIGHTS OPS CHECK GOOD. WORK DONE PER 33-51-06.;[02] REPLACED BOTH EMER CHARGER ASSY (M1676) AND BATTERY PACK WITH NEW; ALL EMER LIGHTS OPS CHSDR SWAA2026040786870Light · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED LT AFT EMERGENCY EXIT WINDOW LIGHT IAW AMM 33-21-00. OPS CHECK OK.SDR SWAA2026040786777Circuit Breaker · incorrectON SHORT FINAL; FLAPS SELECTED TO 5 WITH NO FLAP MOVEMENT. RAN QRH AND ALTN FLAPS USED FOR LANDING. FOUND C/B P6-2 A12 POPPED. RESET C/B AND C/B STAYS IN.<[01] FOUND C/B C213 (FC TE FLAP POS/SKEW SNSR & IND LEFT) AT P6-2 A12 TO BE IN AND REMAINS IN. FOUND MAINSDR CALA2026040715163Bulb · inoperativeR2 DOOR EXTERIOR SLIDE EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS IN THE EMERGENCY EXTERIOR SLIDE LIGHT IAW 33-51-06. OPS CHECKED GOOD.SDR CALA2026040715162Frame · crackedRIGHT FR 20 DOUBLE JOGGLE LOWER AREA HOLE 12 HAD A CRACK INDICATION IN FRAME LAYER AT 6 O`CLOCK DIRECTION, 25% S.H. REPAIRED HOLE 12 AND ASSOCIATED HOLE 11 AT FR 20 RH LOWER DOUBLE JOGGLE AREA IAW SRM 53-11-12-300-012, REPAIR CATEGORY B.SDR CALA2026040715161Frame · crackedLEFT FR 20 DOUBLE JOGGLE UPPER AREA HOLE 6 HAD A CRACK INDICATION IN FRAME LAYER A 2 O`CLOCK DIRECTION, 60% S.H. REPAIRED HOLE 6 & ASSOCIATED HOLE 5 AT FR 20 LT UPPER DOUBLE JOGGLE AREA IAW SRM 53-11-12-300-012, CATEGORY B.SDR CALA2026040715160Frame · crackedLEFT FR 20 DOUBLE JOGGLE UPPER AREA HOLE A HAD A CRACK INDICATION IN FRAME LAYER AT 2 O`CLOCK DIRECTION, 70% S.H. REPAIRED HOLE A AT FR 20 LT UPPER DOUBLE JOGGLE AREA IAW SRM 53-11-12-300-012, CATEGORY B REPAIR.SDR CALA2026040715159Frame · crackedLEFT FR 20 DOUBLE JOGGLE UPPER AREA HOLE B HAS CRACK INDICATION IN FRAME LAYER AT 2 O`CLOCK DIRECTION, 100% S.H. REPAIRED HOLE B AT FR 20 LT UPPER DOUBLE JOGGLE AREA IAW SRM 53-11-12-300-012, CATEGORY B REPAIR.SDR CALA2026040715158Frame · crackedLEFT FR 20 DOUBLE JOGGLE UPPER AREA HOLE D HAS A CRACK INDICATION IN THE FRAME LAYER AT THE 2 O`CLOCK DIRECTION, 60% S.H. REPAIRED HOLE D & ASSOCIATED HOLE C AT FR 20 LEFT, UPPER DOUBLE JOGGLE AREA IAW SRM 53-11-12-300-012, CATEGORY B REPAIRSDR CALA2026040715150Bracket · crackedPANEL 195BL MOUNTING BRACKET AT WS 589.5 FOUND BROKEN. REMOVED TWO TENSION HILOK COLLARS AND REMOVED BROKEN BRACKET FROM WING. INSTALLED PANEL MOUNTING BRACKET IAW SRM 51-40-02.SDR CALA2026040715149Skin · crackedDURING GVI OF THE SKIN AROUND THE DOOR CUTOUT LOWER CORNERS (STEP2), FINDING A REPAIR IN EXTERNAL SURFACE. . WORKED IAW EC/RA #5330-07731 AND EA 757-5330-13-A4329, REV-.SDR CALA2026040715148Battery Pack · inoperativeRIGHT AFT EXTERIOR OVERWING LIGHT INOPERATIVE, AND LENS CRACKED. RELAMPED WITH NEW BULB, NO HELP. HUNG NEW LIGHT MODULE ASSY, NO HELP. REMOVED DADO PANELS AT SEAT 22 DEF TO CHECK CONNECTOR D12018 AND FOUND CONNECTOR MATED IAW WDM 33-51-13, REPLACED THE RT SDR CALA2026040715147Battery Pack · no testEMERGENCY LIGHTS INOPERATIVE. BATTERY PACK M02816 NOT TESTING PROPERLY. REPLACED BATTERY PACK REF AMM 33-51-06-960-805. OPS CHECKED SAT.SDR CALA2026040715132Battery · no testCIDS EMERGENCY LIGHT SYSTEMS TEST FAILED. FAULT LIGHT EPSU BATTERY AFT L. 33-51-38 REPLACED EPSU BATTERY AFT L 13WL PER AMM 33-51-38-400-002-A. BITE TEST OP CHECKS GOOD.SDR DALA2026040702203Cooling Fan · leakingFUMES - DESCENDING AT FL140 UNTIL LANDING, CREW REPORTED DIRTY SOCK ODOR. DECLARED EMERGENCY AND DONNED OXYGEN MASKS. APU WAS ON MEL FROM PRIOR EVENT IN YYZ. FOUND APU COOLING FAN AND FCU LEAKING OIL. REPLACED COOLING FAN AND FCU. INLET DOOR CONTAMINATED WITSDR MASA2026032500013Battery · no testMEGAPHONE DEAD NOT TESTING. R & R MEGAPHONE BATTORIESSDR 2026FA0000257Attach Bolt · shearedEXPERIENCED A RIGHT MAIN GEAR COLLAPSE DURING LANDING ROLLOUT. FURTHER EXAMINATION OF THE COLLAPSE IDENTIFIED A BOLT AND THE BELLCRANK HAVING SHEARED/BROKEN.SDR DALA2026040602189Door · fodL2 DOOR WONT LATCH CLOSED, (WILL NOT ARM). CLEANED FOD AND OPS CHECKED GOOD. (7966150) AIRCRAFT WAS GROUNDED.SDR DALA2026040602183Power Supply · no testCABIN L2 DOOR, EPSU TEST FAILED. REPLACED CABIN L2 DOOR, EPSU IAW AMM 33-51-38. OK FOR SERVICE. (1530876) AIRCRAFT WAS GROUNDED.SDR GTIA2026040639340Unknown · odorDURING DESCENT FA REPORTS ROW 40 INTERMITENT ODOR OF BURNED WIRES OR ELECTRICAL BURNING. NO SMOKE PRESENT. FOLLOW TSM 05-50-00-810-831-A ID AS LEVEL A, TYPE 10 INSP AFT CABIN FOR BURNT BALLAST AND OTHER ITEMS THAT CAN CAUSE THE ODOR. COULD NOT DUPLICATE THE SDR 2026FA0000255Truss · brokenAIRCRAFT LANDED AND NOSE GEAR COLLAPSED ON ROLLOUT. NOSE TRUSS BROKEN CAUSED THE GEAR TO COLLAPSE.SDR IXXA2026040600001Support Angle · corrodedCORROSION ON SUPPORT ANGLE IN LWW FOR STRUT DOOR CUTOUTSDR QR9R2026040600002Rotor Head · out of limitsTHE LAMINATED PILE ASSEMBLY WAS RECEIVED FROM SUPPLY WITH A GAP EXCESS OF .0078".SDR WX0A2026040632777Unknown · odor(AIRCRAFT NOT GROUNDED) FA'S REPORT FOUL ODOR/DIRTY SOCK SMELL IN FWD AND AFT CABIN DURING DESCENT. / PERFORMED A32X-21-000-001 WITH APU BLEED AS SOURCE UNABLE TO DUPLICATE SMELL. TRACKING UNDER M313 # 229609, WITHIN 5 DAYS, PERFORM TASK CARD A32X-21-000-002. SDR YENA2026040600375Outflow Valve · failedFLT 1207, FLL-LAS. AN EMERGENCY WAS DECLARED, AIRCRAFT RETURNED TO FLL, VENT SKIN VALVE FAULT AFTER TAKE OFF COMPLETED ECAM ACTIONS WOULDN'T RESET, RETURNED TO FLL, PERFORMED AN OVERWEIGHT LANDING 4600 LBS OVER TOUCHDOWN AT 300 FT/MIN, REMOVED AND REPLACED