duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'bb296ea55e6be421081a2726fe2bdb4004709894f5cd44cc6a0fc1ef92e80be4' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'bb296ea55e6be421081a2726fe2bdb4004709894f5cd44cc6a0fc1ef92e80be4' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO STA 908 SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.
FIGURE 43: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: May 06, 2019 737-53A1382 RB 217 of 227 REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT
REQUIREMENTS BULLETIN 737-53A1382
ALERT ALERT This Figure applies only to: Group 8.
STA 727 000] 2)
STA STA 908 727G
STA STA 1016 727 S-1 000000000000000000 - S-14R FRAME FWD
UPPER SKIN *LOWER SKIN
TYPICAL CRACK
STRINGER
TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851578 FIGURE 44: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 218 of 227
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727G TO STA 908 SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.
FIGURE 44: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: May 06, 2019 737-53A1382 RB 219 of 227 REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT
REQUIREMENTS BULLETIN 737-53A1382
ALERT ALERT This Figure applies only to: Group 9, Configuration 1.
STA 1016 STA 727 STA 847 27A
STA ISTA 1016 727
- S-1 0000000000000
- S-14R FRAME FWD
UPPER SKIN
LOWER SKIN
TYPICAL CRACK
STRINGER-
TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851579 FIGURE 45: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 220 of 227
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO STA 847 SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.
FIGURE 45: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: May 06, 2019 737-53A1382 RB 221 of 227 REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT
REQUIREMENTS BULLETIN 737-53A1382
ALERT ALERT This Figure applies only to: Group 10.
STA 1016 STA 727 STA 787
STA ISTA 1016 727
- S-1 0000000000000
- S-14R FRAME FWD
UPPER SKIN
LOWER SKIN
TYPICAL CRACK
STRINGER-
TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851580 FIGURE 46: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 Copyright © Unpublished 737-53A1382 RB Work - See page 1 for details. 222 of 227
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO STA 787 SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.
FIGURE 46: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: May 06, 2019 737-53A1382 RB 223 of 227 REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT
REQUIREMENTS BULLETIN 737-53A1382
ALERT ALERT This Figure applies only to: Group 10.
STA 1016 STA 727
STA STA 908 787 STA 1016
- S-1 0000090000000
- S-14R FRAME FWD
UPPER SKIN
LOWER SKIN
TYPICAL CRACK
STRINGER-
TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851581 FIGURE 47: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 737-53A1382 RB Copyright © Unpublished Work - See page 1 for details. 224 of 227
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 787 TO STA 908 SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.
FIGURE 47: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: May 06, 2019 737-53A1382 RB 225 of 227 REQUIREMENTS BULLETIN 737-53A1382
ALERTALERT
REQUIREMENTS BULLETIN 737-53A1382
ALERT ALERT This Figure applies only to: Group 11, Configuration 1.
STA 727
STA STA 847 727A STA 1016 000 0000000000000
- S-14R FRAME
UPPER SKIN *LOWER SKIN
TYPICAL CRACK STRINGER•
TYPICAL SKIN LAP SPLICE INSPECTION AREA 2851582 FIGURE 48: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 1 OF 2) Original Issue: May 06, 2019 Export Controlled ECCN: 9E991 Copyright © Unpublished 737-53A1382 RB Work - See page 1 for details. 226 of 227
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1S-14R, STA 727A TO STA 847 SKIN - LAP SPLICEInspect1
(a) Do the Open Hole - High Frequency Eddy Current (HFEC) inspection of the lower skin at all the lower fastener row holes for any crack in accordance with NDT Manual Part 6, 51-00-00, Procedure 16.
Holes may be oversized up to 0.032 inch diameter larger than the production hole size as needed to clean up hole for open hole HFEC inspection.
FIGURE 48: SECTION 46 - SKIN LAP SPLICE AT STRINGER S-14R - OPEN HOLE-HIGH FREQUENCY
EDDY CURRENT INSPECTION (SHEET 2 OF 2) Export Controlled ECCN: 9E991 Copyright © Unpublished Work - See page 1 for details.
Original Issue: May 06, 2019 737-53A1382 RB 227 of 227 REQUIREMENTS BULLETIN 737-53A1382