Show pages 49–60

Group 5-6:

Upper Deck Floor Beam Station (STA) 580 NotesExisting Part NumberNameQTYPart Number / Specification

(c) (d)BACR15BA3B*Rivet4BACR15BA3D6C or BACR15BA4D*C

(e)-Chemical Conversion Coating4 OuncesType 2, Class A

(f)-Primer1/4 PintBMS 10-11, Type I

(f)-Sealant4 OuncesBMS 5-95, Class B

(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2

(a) Fabricate a new part. Refer to APPENDIX A.

(b) Discard the existing part.

(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.

(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.

(e) Refer to SOPM 20-43-03 for supplier data.

(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.

Group 1-4:

Upper Deck Floor Beam Station (STA) 600 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06821-9 or 65B06821-37 Upper Chord165B06821-9 or 65B06821-37

(a) (b)65B06821-3Reinforcement Angle L/H165B06821-3

(a) (b)65B06821-4Reinforcement Angle R/H165B06821-4

(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X

(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X

(c) (d)BACB30FN5*Bolt2BACB30NW6K4

(c) (d)BACB30FM5*Bolt4BACB30VT6K3

(c) (d)BACB30FM5*Bolt81BACB30VT6K4

(c) (d)BACB30FM5*Bolt33BACB30VT6K5

(c) (d)BACB30FM5*Bolt5BACB30VT6K6

(c) (d)BACB30FM6*Bolt7BACB30NX6K3X

(c) (d)BACB30FM6*Bolt10BACB30NX6K5X Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 61 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 1-4:

Upper Deck Floor Beam Station (STA) 600 NotesExisting Part NumberNameQTYPart Number / Specification

(c)-Collar19BACC30BH6

(c)-Collar124BACC30BL6

(c)-Collar28BACC30M6

(c)-Collar16BACC30M8

(c) (d)BACR15BB5D*Rivet136BACR15BB5D5C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet28BACR15BB5D6C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet4BACR15BB5D7C or BACR15BB6D*C

(c) (d)BACR15BA5D*Rivet1BACR15BA5D5C or BACR15BA6D*C

(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or BACR15BA7D*C

(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or BACR15BA4D*C

(e)-Chemical Conversion Coating4 OuncesType 2, Class A

(f)-Primer1/4 PintBMS 10-11, Type I

(f)-Sealant4 OuncesBMS 5-95, Class B

(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2

(a) Fabricate a new part. Refer to APPENDIX A.

(b) Discard the existing part.

(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.

(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.

(e) Refer to SOPM 20-43-03 for supplier data.

(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.

Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 62 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 5-6:

Upper Deck Floor Beam Station (STA) 600 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06821-27 or 65B26467-19 Upper Chord165B06821-27 or 65B26467-19

(a) (b)65B06821-30 or 65B26467-15 Reinforcement Angle L/H165B06821-30 or 65B26467-15

(a) (b)65B06821-31 or 65B26467-16 Reinforcement Angle R/H165B06821-31 or 65B26467-16

(c) (d)BACB30MY5K*Bolt11BACB30MY6K3

(c) (d)BACB30MY5K*Bolt82BACB30MY6K4

(c) (d)BACB30MY5K*Bolt17BACB30MY6K5

(c) (d)BACB30MY5K*Bolt2BACB30MY6K6

(c) (d)BACB30MY6K*Bolt8BACB30NX6K4X

(c) (d)BACB30MY6K*Bolt14BACB30NX6K5X

(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X

(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X

(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X

(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X

(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X

(c)-Collar22BACC30BH6

(c)-Collar146BACC30M6

(c)-Collar18BACC30M8

(c) (d)BACR15BB5D*Rivet129BACR15BB5D5C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet13BACR15BB5D6C or BACR15BB6D*C

(c) (d)BACR15BB6D*Rivet8BACR15BB6D6C or BACR15BB7D*C

(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or BACR15BA7D*C

(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or BACR15BA4D*C

(e)-Chemical Conversion Coating4 OuncesType 2, Class A

(f)-Primer1/4 PintBMS 10-11, Type I

(f)-Sealant4 OuncesBMS 5-95, Class B Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 63 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 5-6:

Upper Deck Floor Beam Station (STA) 600 NotesExisting Part NumberNameQTYPart Number / Specification

(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2

(a) Fabricate a new part. Refer to APPENDIX A.

(b) Discard the existing part.

(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.

(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.

(e) Refer to SOPM 20-43-03 for supplier data.

(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.

Group 1-4:

Upper Deck Floor Beam Station (STA) 620 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06822-3 or 65B06822-42 Upper Chord165B06822-3 or 65B06822-42

(a) (b)65B06822-9Reinforcement Angle L/H165B06822-9

(a) (b)65B06822-10Reinforcement Angle R/H165B06822-10

(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X

(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X

(c) (d)BACB30FN5*Bolt2BACB30NW6K4

(c) (d)BACB30FM5*Bolt6BACB30VT6K3

(c) (d)BACB30FM5*Bolt96BACB30VT6K4

(c) (d)BACB30FM5*Bolt19BACB30VT6K5

(c) (d)BACB30FM6*Bolt10BACB30NX6K3X

(c) (d)BACB30FM6*Bolt12BACB30NX6K5X

(c) (d)BACB30FM6*Bolt2BACB30NX6K9X

(c) (d)BACB30FN6*Bolt44BACB30NW6K6X

(c)-Collar122BACC30BL6

(c)-Collar24BACC30BH6

(c)-Collar46BACC30M6

(c)-Collar16BACC30M8 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 64 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 1-4:

Upper Deck Floor Beam Station (STA) 620 NotesExisting Part NumberNameQTYPart Number / Specification

(c) (d)BACR15BB5D*Rivet133BACR15BB5D5C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet27BACR15BB5D6C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or BACR15BB6D*C

(c) (d)MS20426D5Rivet2BACR15BA6D9C or BACR15BA7D*C

(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or BACR15BA4D*C

(e)-Chemical Conversion Coating4 OuncesType 2, Class A

(f)-Primer1/4 PintBMS 10-11, Type I

(f)-Sealant4 OuncesBMS 5-95, Class B

(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2

(a) Fabricate a new part. Refer to APPENDIX A.

(b) Discard the existing part.

(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.

(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.

(e) Refer to SOPM 20-43-03 for supplier data.

(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.

Group 5-6:

Upper Deck Floor Beam Station (STA) 620 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06822-30 or 65B26467-44 Upper Chord165B06822-30 or 65B26467-44

(a) (b)65B06822-33 or 65B26467-46 Reinforcement Angle L/H165B06822-33 or 65B26467-46

(a) (b)65B06822-34 or 65B26467-47 Reinforcement Angle R/H165B06822-34 or 65B26467-47

(c) (d)BACB30MY5K*Bolt82BACB30MY6K4 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 65 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 5-6:

Upper Deck Floor Beam Station (STA) 620 NotesExisting Part NumberNameQTYPart Number / Specification

(c) (d)BACB30MY5K*Bolt14BACB30MY6K5

(c) (d)BACB30MY6K*Bolt8BACB30NX6K4X

(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X

(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X

(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X

(c) (d)BACB30NX5K*Bolt4BACB30NX6K3

(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X

(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X

(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X

(c)-Collar24BACC30BH6

(c)-Collar130BACC30M6

(c)-Collar18BACC30M8

(c) (d)BACR15BB5D*Rivet148BACR15BB5D5C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet13BACR15BB5D6C or BACR15BB6D*C

(c) (d)BACR15BB6D*Rivet6BACR15BB6D6C or BACR15BB7D*C

(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or BACR15BA7D*C

(c) (d)BACR15BA3D*Rivet12BACR15BA3D6C or BACR15BA4D*C

(e)-Chemical Conversion Coating4 OuncesType 2, Class A

(f)-Primer1/4 PintBMS 10-11, Type I

(f)-Sealant4 OuncesBMS 5-95, Class B

(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2

(a) Fabricate a new part. Refer to APPENDIX A.

(b) Discard the existing part.

(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.

(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.

Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 66 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 5-6:

Upper Deck Floor Beam Station (STA) 620 NotesExisting Part NumberNameQTYPart Number / Specification

(e) Refer to SOPM 20-43-03 for supplier data.

(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.

Group 1-4:

Upper Deck Floor Beam Station (STA) 640 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06823-9 or 65B06823-36 Upper Chord165B06823-9 or 65B06823-36

(a) (b)65B06823-3Reinforcement Angle L/H165B06823-3

(a) (b)65B06823-4Reinforcement Angle R/H165B06823-4

(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X

(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X

(c) (d)BACB30FN5*Bolt2BACB30NW6K4X

(c) (d)BACB30FM5*Bolt6BACB30VT6K3

(c) (d)BACB30FM5*Bolt91BACB30VT6K4

(c) (d)BACB30FM5*Bolt19BACB30VT6K5

(c) (d)BACB30FM6*Bolt10BACB30NX6K3X

(c) (d)BACB30FM6*Bolt10BACB30NX6K5X

(c) (d)BACB30FM6*Bolt2BACB30NX6K9X

(c) (d)BACB30FN6*Bolt38BACB30NW6K6X

(c)-Collar22BACC30BH6

(c)-Collar116BACC30BL6

(c)-Collar40BACC30M6

(c)-Collar16BACC30M8

(c) (d)BACR15BB5D*Rivet136BACR15BB5D5C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet24BACR15BB5D6C or BACR15BB6D*C

(c) (d)BACR15CE5B*Rivet1BACR15GF5D6 or BACR15GF6D*

(c) (d)BACR15BA6D*Rivet4BACR15BA6D9C or BACR15BA7D*C Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 67 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 1-4:

Upper Deck Floor Beam Station (STA) 640 NotesExisting Part NumberNameQTYPart Number / Specification

(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or BACR15BA4D*C

(e)-Chemical Conversion Coating4 OuncesType 2, Class A

(f)-Primer1/4 PintBMS 10-11, Type I

(f)-Sealant4 OuncesBMS 5-95, Class B

(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2

(a) Fabricate a new part. Refer to APPENDIX A.

(b) Discard the existing part.

(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.

(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.

(e) Refer to SOPM 20-43-03 for supplier data.

(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.

Group 5-6:

Upper Deck Floor Beam Station (STA) 640 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06823-39 or 65B06823-31 Upper Chord165B06823-39 or 65B06823-31

(a) (b)65B06823-42 or 65B06823-3 Reinforcement Angle L/H165B06823-42 or 65B06823-3

(a) (b)65B06823-43 or 65B06823-4 Reinforcement Angle R/H165B06823-43 or 65B06823-4

(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X

(c) (d)BACB30MY5K*Bolt76BACB30NX5K4X

(c) (d)BACB30MY5K*Bolt16BACB30NX5K5X

(c) (d)BACB30MY6K*Bolt8BACB30NX6K4X

(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X

(c) (d)BACB30MY8K*Bolt2BACB30MY8K9X

(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X

(c) (d)BACB30NW6K*Bolt24BACB30NW6K6X Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 68 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 5-6:

Upper Deck Floor Beam Station (STA) 640 NotesExisting Part NumberNameQTYPart Number / Specification

(c)-Collar92BACC30BH5

(c)-Collar20BACC30BH6

(c)-Collar32BACC30M6

(c)-Collar18BACC30M8

(c) (d)BACR15BB5D*Rivet146BACR15BB5D5C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet14BACR15BB5D6C or BACR15BB6D*C

(c) (d)BACR15BB6D*Rivet6BACR15BB6D6C or BACR15BB7D*C

(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or BACR15BA7D*C

(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or BACR15BA4D*C

(e)-Chemical Conversion Coating4 OuncesType 2, Class A

(f)-Primer1/4 PintBMS 10-11, Type I

(f)-Sealant4 OuncesBMS 5-95, Class B

(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2

(a) Fabricate a new part. Refer to APPENDIX A.

(b) Discard the existing part.

(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.

(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.

(e) Refer to SOPM 20-43-03 for supplier data.

(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.

Group 1-4:

Upper Deck Floor Beam Station (STA) 660 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06824-9Upper Chord165B06824-9

(a) (b)65B06824-3Reinforcement Angle L/H165B06824-3 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 69 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 1-4:

Upper Deck Floor Beam Station (STA) 660 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06824-4Reinforcement Angle R/H165B06824-4

(c) (d)BACB30MY8C*Bolt12BACB30MY8K7X

(c) (d)BACB30MY8C*Bolt4BACB30MY8K8X

(c) (d)BACB30FN5*Bolt2BACB30NW6K4

(c) (d)BACB30FM5*Bolt6BACB30VT6K3

(c) (d)BACB30FM5*Bolt93BACB30VT6K4

(c) (d)BACB30FM5*Bolt17BACB30VT6K5

(c) (d)BACB30FM6*Bolt10BACB30NX6K3X

(c) (d)BACB30FM6*Bolt12BACB30NX6K5X

(c) (d)BACB30FM6*Bolt2BACB30NX6K7X

(c) (d)BACB30FN6*Bolt8BACB30NW6K4X

(c) (d)BACB30FN6*Bolt10BACB30NW6K5X

(c) (d)BACB30FN6*Bolt10BACB30NW6K6X

(c)-Collar24BACC30BH6

(c)-Collar116BACC30BL6

(c)-Collar30BACC30M6

(c)-Collar16BACC30M8

(c) (d)BACR15BB5D*Rivet141BACR15BB5D5C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet26BACR15BB5D6C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or BACR15BB6D*C

(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or BACR15BA7D*C

(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or BACR15BA4D*C

(e)-Chemical Conversion Coating4 OuncesType 2, Class A

(f)-Primer1/4 PintBMS 10-11, Type I

(f)-Sealant4 OuncesBMS 5-95, Class B

(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2

(a) Fabricate a new part. Refer to APPENDIX A.

Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 70 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 1-4:

Upper Deck Floor Beam Station (STA) 660 NotesExisting Part NumberNameQTYPart Number / Specification

(b) Discard the existing part.

(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.

(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.

(e) Refer to SOPM 20-43-03 for supplier data.

(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.

Group 5-6:

Upper Deck Floor Beam Station (STA) 660 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06824-49 or 65B26467-24 or 65B06824-45 Upper Chord165B06824-49 or 65B26467-24 or 65B06824-45

(a) (b)65B06824-3Reinforcement Angle L/H165B06824-3

(a) (b)65B06824-4Reinforcement Angle R/H165B06824-4

(a) (b) (g)65B06824-52 or 65B26467-22 Reinforcement Angle165B06824-52 or 65B26467-22

(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X

(c) (d)BACB30MY6K*Bolt20BACB30NX6K5X

(c) (d)BACB30MY6K*Bolt4BACB30NX6K6X

(c) (d)BACB30MY8K*Bolt2BACB30MY8K9X

(c) (d)BACB30MY5K*Bolt84BACB30MY6K4

(c) (d)BACB30MY5K*Bolt52BACB30MY6K5

(c) (d)BACB30MY5K*Bolt2BACB30MY6K6

(c) (d)BACB30NX6K*Bolt2BACB30NX6K5X

(c) (d)BACB30NW6K*Bolt6BACB30NW6K4X

(c) (d)BACB30NW6K*Bolt6BACB30NW6K5X

(c) (d)BACB30NW6K*Bolt10BACB30NW6K6X

(c)-Collar26BACC30BH6

(c)-Collar160BACC30M6

(c)-Collar16BACC30M8 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 71 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Group 5-6:

Upper Deck Floor Beam Station (STA) 660 NotesExisting Part NumberNameQTYPart Number / Specification

(c) (d)BACR15BB5D*Rivet143BACR15BB5D6C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet9BACR15BB5D7C or BACR15BB6D*C

(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or BACR15BB6D*C

(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or BACR15BB7D*C

(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or BACR15BA7D*C

(c) (d)BACR15BA3D*Rivet8BACR15BA3D6C or BACR15BA4D*C

(e)-Chemical Conversion Coating4 OuncesType 2, Class A

(f)-Primer1/4 PintBMS 10-11, Type I

(f)-Sealant4 OuncesBMS 5-95, Class B

(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II, Class 2

(a) Fabricate a new part. Refer to APPENDIX A.

(b) Discard the existing part.

(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.

(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to correct damage or misalignment. At locations where a larger than original rivet will be installed, verify grip length on installation.

(e) Refer to SOPM 20-43-03 for supplier data.

(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.

(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.

Group 1-4:

Upper Deck Floor Beam Station (STA) 680 NotesExisting Part NumberNameQTYPart Number / Specification

(a) (b)65B06825-13Upper Chord165B06825-13

(a) (b)65B06825-3Reinforcement Angle L/H165B06825-3

(a) (b)65B06825-4Reinforcement Angle R/H165B06825-4 Export Controlled ECCN: 9E991 - BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: June 22, 2012 747-53A2852 72 of 189 BOEING SERVICE BULLETIN 747-53A2852

ALERTALERT

Pages 73–84 of 189