Copy · U.S. DOT/FAA - SB-DC10-28-252-01 · 83 pages

© The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2010-0384; AD 2010-20-14 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

Text

From the PDF’s text layer: layout, tables and figures are lost. The PDF is the document.

Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license
  FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256)
  WHERE p.file_sha256 = 'e55eabc8c7fe50acd15947be7d444b11ea89f23015cfa32913762d637f1aef7d'
  ORDER BY p.page"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

Show pages 61–72

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI UPPER MAINB1-610FUEL PUMP POWER TANK 1 TRANS UPPER MAINB1-620FUEL PUMP POWER TANK 3 AFT UPPER MAINB1-1248FUEL PUMP PWR L UPR UPPER MAINB1-1249FUEL PUMP PWR L LWR LOCATIONC/B NO.BUS 115 VAC GEN-3 UPPER MAINB1-612FUEL PUMP POWER TANK 1 AFT UPPER MAINB1-616FUEL PUMP POWER TANK 3 FWD UPPER MAINB1-756FUEL PUMP POWER TANK 2 TRANS UPPER MAINB1-1251FUEL PUMP PWR R LWR UPPER MAINB1-1646FUEL PUMP PWR R AFT 115 VAC R EMERGENCY OVERHEADB1-680FUEL PUMP TANK 2 LEFT AFT 28 VDC-1 UPPER MAINB1-450FUEL X-FEED CONT 1 UPPER MAINB1-451FUEL X-FEED VALVE LT 1 UPPER MAINB1-458L FUEL DUMP VALVE CONT UPPER MAINB1-498FWD PUMPS PRESS LOW LTS UPPER MAINB1-1246FUEL PUMP PRESS LOW LTS R AUX 28 VDC-2 UPPER MAINB1-452DUMP V IND & FUEL LOW LVL SHUTOFF UPPER MAINB1-453FUEL X-FEED CONT 2 UPPER MAINB1-454FUEL X-FEED VALVE LT 2 UPPER MAINB1-497R AFT PUMPS PRESS LOW LTS UPPER MAINB1-1247FUEL PUMP PRESS LOW LTS L AUX 28 VDC-3 UPPER MAINB1-455FUEL X-FEED CONT 3 UPPER MAINB1-456FUEL X-FEED VALVE LT 3 UPPER MAINB1-457R FUEL DUMP VALVE CONT Appendix R: DC-10-30 W/AFT TANK 3200 GALLONS - FUSE FUNCTIONAL TEST (SHEET 3 OF 9)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 73 of 83 BOEING SERVICE BULLETIN DC10-28-252

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI UPPER MAINB1-460FUEL TK OFF SCHEDULE LTS UPPER MAINB1-496L AFT PUMPS PRESS LOW LTS UPPER MAINB1-2004AFT AUX PUMP FUEL CONTROL Tank 1, 2, 3, UPPER AND AFT TestI-1 The following test should be done with empty tanks as fuse are installed. It is a continuity test and should be performed for each individual fuse. Following table gives the details of each test.

REMARKSPINSTERMINALTEST TYPEFUSE TO BE TESTED TANK 1 7 & 8S3-450LOOP CONTI- NUITY F1-176 - TANK 1 DUMP 1 & 2S3-450LOOP CONTI- NUITY F1-121 Tank 1 4000 lb 5 & 6S3-450LOOP CONTI- NUITY F1-120 Tank 1 6000 lb 1 & 2S3-366LOOP CONT

NOT FULL F1-119 TK 1 TIP 1 & 2S3-684LOOP CONTI- NUITY F1-735 L WING OVERFILL (VENT BOX) TANK 3 7 & 8S3-451LOOP CONTI- NUITY F1-178 - TANK 3 DUMP 1 & 2S3-451LOOP CONTI- NUITY F1-122 Tank 3 4000 lb 5 & 6S3-451LOOP CONTI- NUITY F1-123 Tank 3 6000 lb 1 & 2S3-452LOOP CONT

NOT FULL F1-124 TK 3 TIP 1 & 2S3-683LOOP CONTI- NUITY F1-734 R WING OVERFILL (VENT BOX) TANK 2 Appendix R: DC-10-30 W/AFT TANK 3200 GALLONS - FUSE FUNCTIONAL TEST (SHEET 4 OF 9)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 74 of 83 BOEING SERVICE BULLETIN DC10-28-252

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI 1 & 5S3-454LOOP CONTI- NUITY F1-177 TK 2 DUMP Optional 12 & CS3-454LOOP CONTI- NUITY F1-90 TK 2 40000 LB

UPPER AUX TANK 1 & GND S3-1186CONT TO GND ON EMPTY F1-1364 UPPER AUX 2 & 3S3-1186LOOP CONT

ON EMPTY F1-1376 UPPER AUX

REMARKSPINSTERMINALTEST TYPEFUSE TO BE TESTED

AFT AUX TANK S & RR5-4817LOOP CONT

W/PUMP OFF F1-972 V & UR5-4817LOOP CONT

W/PUMP OFF F1-973 OPTIONAL 1 - If the tank 2 is open this float switch circuit can be checked by moving the float of the float switch up and down and reading the circuit open/ground at S3-454 pin 2.

Job Close-up The test continues for Auxiliary Tanks.I-2 Bring the airplane to the following configuration: Tank 1, 2 & 3 minimum 12000 pounds, UPR tank 6000 pounds and LWR tank full with fuel.

I-2.1 Verify that auxiliary tank FUEL SCHED light, located on the flight engineer's panel is ON when the LWR tank is full. This verifies the F1-1359 and F1-1360 fuses.

Place the LWR Aux Fill valve switch on the Refueling Panel in CLOSE position.

Empty the LWR tank and fill the UPR tank as follows:

Transfer fuel from LWR Aux tank to UPR Aux tank as follows Verify the following C/Bs to be open

STATUSNUMBERNAME OPENB1-1248FUEL PUMP PWR L UPR OPENB1-1250FUEL PUMP PWR R UPR Appendix R: DC-10-30 W/AFT TANK 3200 GALLONS - FUSE FUNCTIONAL TEST (SHEET 5 OF 9)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 75 of 83 BOEING SERVICE BULLETIN DC10-28-252

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI Place L & R UPR & LWR pumps switches on the Flight Engineer panel to BOTH position. The "LWR Tank Press Lo" lights should be ON and then OFF and the "UPR Tank Press Lo" lights are steady ON. During the transfer verify that auxiliary tank FUEL SCHED light, located on the flight engineer's panel turns OFF. Continue fuel transfer from LWR to UPR Aux tank until the "LWR Tank Press Lo" light is ON steady.

Place L & R UPR & LWR AUX pumps switches on the Flight Engineer panel to OFF position and close the following C/Bs:

STATUSNUMBERNAME CLOSEDB1-1248FUEL PUMP PWR L UPR CLOSEDB1-1250FUEL PUMP PWR R UPR Use DC10 AMM 12-11-04 procedure - PRESSURE REFUELING - SERVICING AUTOMATIC PRESSURE REFUELING to fill the UPR AUX tank until completely full. LWR and AFT AUX tanks are empty.

Verify the position of the following C/Bs to be:I-3.2

STATUSNUMBERNAME OPENB1-1647FUEL PUMP POWER L AFT OPENB1-1645FUEL PUMP CONTROL L AFT AUX TANK OPENB1-1644FUEL PUMP CONTROL R AFT AUX TANK OPENB1-475GROUND REFUEL POWER OPENB1-474FUEL TANK FILL VALVE & BAT BUS

SENSING CLOSEDB1-2004AFT AUX FUEL PUMP CONTROL NOTE: Be sure that the fuel quantity in each main Tanks 1, 2, & 3 is over 11500 pounds.

Actuate the AFT AUX TANK LEFT PUMP switch on Flight Engineer panel to OVRD position.

Verify that auxiliary tank FUEL SCHED light, located on the Flight Engineer panel is ON. This verifies the fuses F1-1359 & -1381B.

Actuate the AFT AUX TANK LEFT PUMP switch to OFF position. Verify that auxiliary tank FUEL SCHED light, located on the Flight Engineer's panel turns OFF.

Close the following C/Bs:

STATUSNUMBERNAME CLOSEDB1-1647FUEL PUMP PWR L AFT CLOSEDB1-1645FUEL PUMP CONTROL L AFT AUX TANK CLOSEDB1-1644FUEL PUMP CONTROL R AFT AUX TANK Appendix R: DC-10-30 W/AFT TANK 3200 GALLONS - FUSE FUNCTIONAL TEST (SHEET 6 OF 9)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 76 of 83 BOEING SERVICE BULLETIN DC10-28-252

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI CLOSEDB1-475GROUND REFUEL POWER CLOSEDB1-474FUEL TANK FILL VALVE & BAT BUS

SENSING CLOSEDB1-2004AFT AUX FUEL PUMP CONTROL Verify AFT AUX TANK BALLAST CONTROL SW located on the Flight Engineer Equipment panel is in the OFF position.

I-3.3 Transfer 3000 pounds fuel from UPR AUX tank to AFT AUX Tank and then 3000 pounds from Tank 2 to AFT AUX tank as follows:

Access and arm the Refueling Panel located in the right wing leading edge.

Open the AFT Aux fill valve placing AFT Aux Fill valve switch on the Refueling panel to OPEN position.

Place L & R UPR & LWR tank pump switches on the Flight Engineer panel to UPR position. Verify the AFT Aux Fill valve open light is ON. After 3000 pounds fuel was transferred shut off the pumps by placing the UPR pump switches on the Flight Engineer panel to OFF position. To read fuel quantity in any individual Aux tanks use the appropriate "AUX TANK QTY SEL" switch on the flight engineer (FE) panel.

Turn on Tank 2 transfer pump placing the pump switch on Flight Engineer panel to ON position.

Transfer approx. 3000 pounds fuel from Tank 2 to AFT tank and observe that auxiliary tank FUEL SCHED light, located on the FE panel turns ON. This verifies the fuses F1-1361 and -1363.

Place the AFT Aux tank fill valve switch to the CLOSE position. Observe AFT Aux Fill valve open light goes OFF. Turn off Tank 2 Transfer pump on the Flight Engineer panel.

Disarm the Refueling panel.

Transfer fuel from UPR tank to fill up tank 2 as follows:

Turn ON the UPR Aux transfer pumps by placing the L& R UPR & LWR tank pump switches located on Flight Engineer panel to UPR position. Place the Tank 2 fill valve switch on Flight Engineer panel to the OPEN position. Tank 2 fill valve light will be ON while the tank is filling then extinguishes when Tank 2 is completely full. Verify that the Aux Tank FUEL SCHED light goes OUT during this transfer.

Disarm the Tank 2 fill valve by placing its switch on Flight Engineer panel to CLOSE position.

Continue to transfer fuel from UPR Aux tank to Tanks 1 and 3 as follows:

Place Tank 1 & 3 fill valve switch to the OPEN position. Observe the Fill Valve Open light for each tank come ON. When each tank 1 & 3 reaches 19000 pounds place the appropriate Fill Valve switch to the CLOSE position. When tanks 1& 3 are at the correct level place the L & R UPR & LWR tank pumps switch to OFF position.

Access the Refueling Panel located in the right wing leading edge. Make sure all fill valve switches are in the CLOSE position then arm the refueling panel Transfer fuel from UPR Aux tank to fill the AFT Aux tank as follows:

Place the L & R UPR & LWR Tank pump switches to the UPR position.

Appendix R: DC-10-30 W/AFT TANK 3200 GALLONS - FUSE FUNCTIONAL TEST (SHEET 7 OF 9)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 77 of 83 BOEING SERVICE BULLETIN DC10-28-252

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI Place the AFT Aux tank fill valve switch on the Refueling panel to OPEN position and verify that the AFT Aux fill valve light is ON. Continue transferring fuel to AFT Aux until AFT Aux tank fuel quantity is above 10000 pounds but not above 12000 pounds and the UPR Aux quantity is less than 10000 pounds. Move the AFT Aux fill valve switch on the Refueling panel to the CLOSE position to disarm the valve. Turn OFF the UPR Aux pumps by placing the L & R UPR & LWR tank pump switches to the OFF position. Disarm the Refueling panel.

Verify the position of the following C/Bs to be:

POSITIONNUMBERNAME CLOSEDB1-475GROUND REFUEL POWER CLOSEDB1-474FUEL TANK FILL VALVE & BAT BUS

SENSING With Upper Aux Tank pump not running move Tank 1 & 3 fill valve switch to OPEN position and verify that they remain latched. This verifies fuse F1- 90 .

Move Tank 1 & 3 fill valve switch to Close position.

Verify the position of the following C/Bs to be:I-3.4

POSITIONNUMBERNAME OPENB1-1647FUEL PUMP POWER L AFT CLOSEDB1-1645FUEL PUMP CONTROL L AFT AUX TANK CLOSEDB1-1644FUEL PUMP CONTROL R AFT AUX TANK OPENB1-475GROUND REFUEL POWER OPENB1-474FUEL TANK FILL VALVE & BAT BUS

SENSING OPENB1-2004AFT AUX FUEL PUMP CONTROL Actuate the AFT AUX TANK LEFT PUMP switch to OVRD position. Verify that the auxiliary tank FUEL SCHED light, located on the flight engineer's panel is ON. This verifies the fuses F1-1358 and -1381A .

Actuate the AFT AUX TANK LEFT PUMP switch to OFF position. Verify that the auxiliary tank FUEL SCHED light, located on the Flight Engineer's panel turns OFF.

Transfer fuel to AFT AUX tank from UPR AUX tank and then from tanks 1 and 3 as follows:I-3.5 Appendix R: DC-10-30 W/AFT TANK 3200 GALLONS - FUSE FUNCTIONAL TEST (SHEET 8 OF 9)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 78 of 83 BOEING SERVICE BULLETIN DC10-28-252

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI Arm the refueling panel. Start the UPR tank pumps by placing the L & R UPR & LWR TANK PUMP switches located on Flight Engineer panel to UPR position. Place the AFT Aux tank fill valve switch on the Refueling panel to OPEN position and verify that the AFT Aux fill valve light is ON. Continue transferring fuel to AFT Aux tank until UPR tank fuel quantity is 6000 pounds. Stop the UPR pump by placing the L & R UPR & LWR TANK PUMP switches located on Flight Engineer panel to OFF position.

Turn Tank 1 and Tank 3 transfer pumps switches on the flight engineer panel ON to transfer from these tanks until AFT Aux tank is full (AFT AUX valve light on the Refueling panel turns OFF).

Verify that auxiliary tank FUEL SCHED light, located on the flight engineer's panel is ON. This verifies the fuses F1-1362 and -1359:

Place the AFT Aux tank fill valve switch to close position. Turn OFF tank 1 & 3 transfer pumps.

Open the following C/B

POSITIONNUMBERNAME UPPER MAINB1-460FUEL TK OFF SCHEDULE LTS FLT ENG UPPR MAIN CB PNLB1-1246FUEL PUMPS PRESS LOW LTS R AUX FLT ENG UPPR MAIN CB PNLB1-1247FUEL PUMPS PRESS LOW LTS L AUX Gain access to AFT AUX Transfer fuse F-1365 through the Center Cargo Compartment Door. Disconnect the connector P1-4817 and on the receptacle side measure the continuity between pins C & D. Continuity between these pins verifies fuse F1-1365.

Reconnect P1-4817 connector, remove tools and close the access door.

Transfer fuel from AFT Aux tank to UPR Aux tank until AFT Aux tank is empty as follows:

Arm Refueling panel. Actuate the L & R AFT TANK PUMP switches on the Flight Engineer panel to OVRD position. Place the UPR Aux fill valve switch on Refueling panel to OPEN position. Transfer fuel until AFT Aux tank is empty (AFT tank pump press low light steady ON). Stop L & R AFT tank pumps by placing the L & R AFT TANK PUMP switch in OFF position and close the UPR tank fill valve by placing UPR Aux fill valve switch to CLOSE position. Disarm the Refueling panel.

Job Close-up - remove all the tools and equipment from the work area. Make sure the area is clean.

Appendix R: DC-10-30 W/AFT TANK 3200 GALLONS - FUSE FUNCTIONAL TEST (SHEET 9 OF 9)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 79 of 83 BOEING SERVICE BULLETIN DC10-28-252

This Appendix applies only to: Group 6.

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI This test should be performed in the order shown below.

REFERENCES (AMM) Tasks:

DC-10 AMM 12-11-04, PRESSURE REFUELING - SERVICING AUTOMATIC PRESSURE REFU- ELING DC-10 AMM 12-11-05, DEFUELING - SERVICING This procedure should be used as necessary.

Depower the Fuse system or open the associated Circuit Breakers.

After fuse installation do a continuity test as shown in the table below.

Note: For some fuses check continuity between two pins, for others check continuity to ground.

Tank 1, 2, 3, CENTER WING, FWD AUX. and AFT AUX. TestI-1 The following test should be done with empty tanks as fuse are installed. It is a continuity test and should be performed for each individual fuse. Following table gives the details of each test.

REMARKSPINSTERMINALTEST TYPEFUSE TO BE TESTED TANK 1 7 & 8S3-450LOOP CONTI- NUITY F1-176 - TANK 1 DUMP 1 & 2S3-450LOOP CONTI- NUITY F1-121 Tank 1 4000 lb 5 & 6S3-450LOOP CONTI- NUITY F1-120 Tank 1 6000 lb 1 & 2S3-366LOOP CONT

NOT FULL F1-119 TK 1 TIP 1 & 2S3-684LOOP CONTI- NUITY F1-735 L WING OVERFILL (VENT BOX) TANK 3 7 & 8S3-451LOOP CONTI- NUITY F1-178 - TANK 3 DUMP 1 & 2S3-451LOOP CONTI- NUITY F1-122 Tank 3 4000 lb 5 & 6S3-451LOOP CONTI- NUITY F1-123 Tank 3 6000 lb Appendix S: DC-10-30F (KC-10A) - FUSE FUNCTIONAL TEST (SHEET 1 OF 2)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 80 of 83 BOEING SERVICE BULLETIN DC10-28-252

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI 1 & 2S3-452LOOP CONT

NOT FULL F1-124 TK 3 TIP 1 & 2S3-683LOOP CONTI- NUITY F1-734 R WING OVERFILL (VENT BOX)

REMARKSPINSTERMINALTEST TYPEFUSE TO BE TESTED TANK 2 1 & 5S3-454LOOP CONTI- NUITY F1-177 TK 2 DUMP Optional 12 & CS3-454LOOP CONTI- NUITY F1-90 TK 2 40000 LB

AFT AUX TANK 2 & 5S3-1110LOOP CONTI- NUITY F1-1327 AFT FUS LL

FWD AUX TANK 2 & 14S3-1277LOOP CONTI- NUITY F1-1277 FWD FUS LL 12 & 13S3-1109LOOP CONTI- NUITY F1-1293 FWD FUS INT OPTIONAL 1 - If the tank 2 is open this float switch circuit can be checked by moving the float of the float switch up and down and reading the circuit open/ground at S3-454 pin 2.

AERIAL REFUELING PUMP CONTROL FLOAT SWITCHESI-1 To perform this test minimum 7000 lbs fuel is necessary in the UPR Aux tank.I-1.1 After the correct amount of fuel Gain access to F1-1374 and F1-1328 fuses through Left and Right Main Landing Gear Wheel Wells.

Do the continuity test for the following fuses: F1-1374, -1328.

REMARKSPINSTERMINALTEST TYPEFUSE TO BE TESTED

CENTER WING TANKS 5 & 6S3-802LOOP CONTI- NUITY

CENTER WING FUEL TANK LOW LEVEL R, F1-1374 5 & 6S3-803LOOP CONT

ON EMPTY

CENTER WING FUEL TANK LOW LEVEL L, F1-1328 Job Close-up - remove all the tools and equipment from the work area. Make sure the area is clean.

Appendix S: DC-10-30F (KC-10A) - FUSE FUNCTIONAL TEST (SHEET 2 OF 2)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 81 of 83 BOEING SERVICE BULLETIN DC10-28-252

This Appendix applies only to: Group 7.

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI This test should be performed in the order shown below.

REFERENCES (AMM) Tasks:

DC-10 AMM 12-11-04, PRESSURE REFUELING - SERVICING AUTOMATIC PRESSURE REFU- ELING DC-10 AMM 12-11-05, DEFUELING - SERVICING This procedure should be used as necessary.

Depower the Fuse system or open the associated Circuit Breakers.

After fuse installation do a continuity test as shown in the table below.

Note: For some fuses check continuity between two pins, for others check continuity to ground.

Tank 1, 2, 3, and CENTER WING TestI-1 The following test should be done with empty tanks as fuse are installed. It is a continuity test and should be performed for each individual fuse. Following table gives the details of each test.

REMARKSPINSTERMINALTEST TYPEFUSE TO BE TESTED TANK 1 7 & 8S3-450LOOP CONTI- NUITY F1-176 - TANK 1 DUMP 1 & 2S3-450LOOP CONTI- NUITY F1-121 Tank 1 4000 lb 5 & 6S3-450LOOP CONTI- NUITY F1-120 Tank 1 6000 lb 1 & 2S3-366LOOP CONT

NOT FULL F1-119 TK 1 TIP 1 & 2S3-684LOOP CONTI- NUITY F1-735 L WING OVERFILL (VENT BOX) TANK 3 7 & 8S3-451LOOP CONTI- NUITY F1-178 - TANK 3 DUMP 1 & 2S3-451LOOP CONTI- NUITY F1-122 Tank 3 4000 lb 5 & 6S3-451LOOP CONTI- NUITY F1-123 Tank 3 6000 lb Appendix T: DC-10-30F (KDC-10) - FUSE FUNCTIONAL TEST (SHEET 1 OF 2)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 82 of 83 BOEING SERVICE BULLETIN DC10-28-252

RETURN-TO SERVICE TEST OF THE FUEL TANKS FLOAT SWITCHESI 1 & 2S3-452LOOP CONT

NOT FULL F1-124 TK 3 TIP 1 & 2S3-683LOOP CONTI- NUITY F1-734 R WING OVERFILL (VENT BOX) TANK 2 1 & 5S3-454LOOP CONTI- NUITY F1-177 TK 2 DUMP Optional 12 & CS3-454LOOP CONTI- NUITY F1-90 TK 2 40000 LB OPTIONAL 1 - If the tank 2 is open this float switch circuit can be checked by moving the float of the float switch up and down and reading the circuit open/ground at S3-454 pin 2.

AERIAL REFUELING PUMP CONTROL FLOAT SWITCHESI-1 To perform this test minimum 7000 lbs fuel is necessary in the UPR Aux tank.I-1.1 After the correct amount of fuel Gain access to F1-1374 and F1-1328 fuses through Left and Right Main Landing Gear Wheel Wells.

Do the continuity test for the following fuses: F1-1374, -1328.

REMARKSPINSTERMINALTEST TYPEFUSE TO BE TESTED

CENTER WING TANKS 5 & 6S3-802LOOP CONTI- NUITY

CENTER WING FUEL TANK LOW LEVEL R, F1-1374 5 & 6S3-803LOOP CONT

ON EMPTY

CENTER WING FUEL TANK LOW LEVEL L, F1-1328 Job Close-up - remove all the tools and equipment from the work area. Make sure the area is clean.

Appendix T: DC-10-30F (KDC-10) - FUSE FUNCTIONAL TEST (SHEET 2 OF 2)

BOEING PROPRIETARY - Copyright © Unpublished Work - See page 1 for details.

Original Issue: November 25, 2008 DC10-28-252Revision 1 January 06, 2010 83 of 83 BOEING SERVICE BULLETIN DC10-28-252