duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'e7ea4072f7cbd235f92bce19b4a1fc1c0b57fa6f10145b6f9246408256fddf13' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'e7ea4072f7cbd235f92bce19b4a1fc1c0b57fa6f10145b6f9246408256fddf13' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
Honeywell
SERVICE BULLETIN 930-1006 Page Description Effectivity 13 Paragraph 3.B. (1)(a)5 . Added Paragraph. All 16 Paragraph 4.A. (1) . Added TSO Acronym in Table 4. All 23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 6 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006 Planning Information Effectivity
(1) This service bulletin is applicable to the RP-1 PN 930-1006-010/-012 SW MOD 1, 2.
B. Concurrent Requirements
(1) Not applicable.
C. Reason
(1) This conversion is to use update AGM software with hazard display.
D. Description
(1) A summary of the work necessary to do this conversion is given below:
(a) The new configuration file is loaded in to the RP-1.
NOTE: This is a configuration file change only. The RP-1 is not disassembled and the inspection seals are not broken.
NOTE: This conversion can be done at a shop location or at a customer location (in the aircraft).
E. Compliance
(1) This is a must to do conversion to be used on EASy IV configuration.
F. Approval
(1) This service bulletin has been reviewed by the Honeywell Radar Systems FAA TSO Specialist. The conversion information herein meets the requirement of TSO.
G. Manpower
(1) This conversion can be completed in the approximate times that follow:
(a) If this conversion is done at a customer location (in the aircraft):
• 0.5 hour for the labor to convert to the PN 930-1006-015.
NOTE: The time identified above does not include the time to get access to the RP-1 on the aircraft.
(b) If this conversion is done at a shop location:
• 0.5 hour for the labor to do the modification of the RP-1
• 2.0 more hours for the labor to do a test of the RP-1.
H. Weight and Balance
(1) None.
23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 7 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006 Electrical Load Data
(1) Not applicable.
Software Accomplishment Summary
(1) A software accomplishment summary has been completed to agree with the necessary conditions of RTCA document DO-178B, Software Considerations in Airborne Systems and Equipment Certification.
K. References
(1) To find, see, and download Honeywell Technical Publications, go to https://aerospace.honeywell.com.
(2) The document that follows is necessary to complete this conversion. Unless specified differently, you can use subsequent revisions.
• CMM, ATA Number 34-41-68 (Publication Number 012-0746-001), Revision 9 or Latest, RP-1 Radar Processor.
Other Publications Affected
(1) CMM, ATA Number 34-41-68 (Publication Number 012-0746-001), Revision 9 or Latest, RP-1 Radar Processor, will be revised because of this service bulletin.
(2) This service bulletin has no effect on the test procedure.
M. Interchangeability or Intermixability of Parts
(1) The operator must speak to the OEM about the interchangeability and intermixability of the RP-1 part numbers identified in this service bulletin.
23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 8 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006
2. Material Information Material - Price and Availability
(1) For available parts, supply times, necessary test documentation, applicable test material prices, and repair support information, go to:
https://aerospace.honeywell.com.
Registered users can enter their Honeywell ID and password. New users must register to create a Honeywell ID.
NOTE: To speak with Honeywell personnel:
Honeywell Aerospace Contact Team Telephone: 800-601-3099 (Toll Free U.S.A./Canada) Telephone: 602-365-3099 (International Direct)
(2) This conversion can be done at a Honeywell service center, Honeywell-authorized repair location or in the aircraft for the price given at the time of the order.
(3) Honeywell can supply the parts necessary to do this conversion. The price for parts will be given at the time of the order. When you make an order for parts, send a purchase order that refers to this service bulletin, ATA Number 930-1006-34-0240 (Publication Number D202202002219). The purchase order must include only the applicable parts specified in Table 2 of this service bulletin.
Industry Support Information
(1) Honeywell will give no reimbursement to do this conversion. The customer will receive an applicable invoice for the conversion of each RP-1 radar processor done at a Honeywell service center or Honeywell-authorized repair location.
C. Material Necessary for Each Component
(1) The parts identified in Table 2 are necessary to do this service bulletin.
Table 2. Operator-Purchased Material Instructions/ Keyword/ List Disposition New PN2, 3, 4 Nomenclature Old PN Qty Price' Codes 620-1974-154 Label, Part Number 620-1956-138/620-1974-136 1 F 718-1761-020 Configuration 718-1761-012 1 Features List File NOTES:
1. The list price is applicable to the parts that Honeywell has available at the time of the order. Refer to the Honeywell, Aerospace Contact Team (Paragraph 2.A.) for the applicable material prices, available parts, supply times, and minimum order quantities.
2. Refer to the Honeywell Aerospace Contact Team (Paragraph 2.A.) when you need data about available parts, supply times, or minimum order quantities.
3. Different supply-times are necessary to supply the parts. Honeywell Aerospace Contact Team (Paragraph 2.A.)
or your local Honeywell service center for schedules, applicable prices, and available parts.
23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 9 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006
4. The customer or local regulatory authority can make decisions about what to do with the used parts. Discard or erase the used software and do not use it again.
Table 3. Instructions/Disposition Codes Code Description Disposition Code F Discard the removed part and replace with a new part.
D. Material Necessary for Each Spare
(1) Same as Paragraph 2.C.
E. Reidentified Parts
(1) Not applicable.
F. Tooling - Price and Availability
(1) The equipment that is necessary to do this conversion is specified in the documents given in Paragraph 1.K. of this service bulletin.
23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 10 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006
3. Accomplishment Instructions A. General WARNING: TO AVOID INJURY TO PERSONNEL, BE AWARE THAT VOLTAGES ARE PRESENT IN THE UNIT AND IN THE TEST EQUIPMENT. VOLTAGES AS LOW AS 28 VOLTS CAN CAUSE SERIOUS INJURY UNDER SOME CONDITIONS. DO NOT BE MISLED BY THE TERM "LOW VOLTAGE."
WARNING: BEFORE YOU USE A MATERIAL, REFER TO THE MANUFACTURER'S MATERIAL SAFETY DATA SHEETS. SOME MATERIALS CAN BE DANGEROUS.
CAUTION: DO NOT USE A MATERIAL THAT IS NOT EQUIVALENT TO THE MATERIAL SPECIFIED BY HONEYWELL. A MATERIAL THAT IS NOT EQUIVALENT CAN
CAUSE DAMAGE TO THE EQUIPMENT AND CAN MAKE THE WARRANTY NOT APPLICABLE.
CAUTION: THE RP-1 CONTAINS ELECTROSTATIC DISCHARGE SENSITIVE ITEMS. USE INDUSTRY APPROVED PRECAUTIONS.
(1) Obey the precautions.
(2) Refer to the RP-1 CMM, ATA Number 34-41-68 (Publication Number 012-0746-001), for procedures and precautions. Use all CAUTIONS and WARNINGS. Refer to the IPL in the CMM for the location of the parts, unless specified differently.
(3) Keep all hardware for use in assembly unless specified differently.
(4) Obey standard established shop practices during conversion of the RP-1 unless specified differently.
(5) When the compact flash card is used for dataloading, the system automatically uploads the software from the card into system memory. When the flash card is detected the only functions that the RP-1 will perform are those of uploading software.
(6) This is a configuration file change only. The RP-1 is not disassembled and the inspection seals are not broken.
(7) This conversion can be done at a shop location or at a customer location (in the aircraft).
(8) Paragraph 3.B. (1) is applicable for the installation of this conversion in RP-1 units when the installation is performed on the aircraft.
(9) Paragraph 3.B. (2) is applicable for the installation of this conversion in RP-1 units when the installation is performed at a service center.
23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 11 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006 B. Procedure WARNING: MAKE SURE ALL PERSONNEL AND OBJECTS ARE AT A SAFE DISTANCE FROM THE ANTENNA DRIVE ASSEMBLY SCAN VOLUME.
NOTE: Complete the instructions in Paragraph 3.B. one time for each unit.
(1) Configuration File Load on the Aircraft
(a) Configuration Assembly Load 1 Make sure the RDR-4000 is not transmitting by verifying the radar is in "Standby".
Make sure no power is applied to the RP. Put the configuration feature software CF card, PN 718-1761-020, in the vertical slot under the right port cover. The right port cover is on the front panel of the RP. Refer to Figure 1.
DISPLAY / MODIFICATION
LEFT PORT DOTS LABEL COVER
- RIGHT PORT COVER
SW/VERSION DATABASE LABEL • SERIAL NUMBER LABEL
• PART NUMBER LABEL PNR 930-1003-RXX ICN-97896-0000382486-001-01 Figure 1. RP-1 Radar Processor, Front View Apply power to the RP.
4 The transfer process can take up to 2 minutes. This can change when the amount of data to be uploaded changes. The data load is complete when the LCD shows the message "Upload Successful". If "Upload Fail", or "Invalid Card" appear then return to Paragraph 3.B. (1)(a)1 in this section. If a proper load is not achevied after a few attempts send the RP to Honeywell for repair.
23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 12 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006 5 When the data load is complete, remove power from the RP-1 and extract the CF card.
(b) Data Load Check NOTE: The instructions in this paragraph use the RP-1 front panel display to make sure the software part numbers are correct. Refer to Figure 1 for the location of the RP-1 front panel display. During data load check, make sure the RDR-4000 is not transmitting by verifying the radar is in "Standby" mode.
1 Apply power to the RP.
Press the scroll button. Scroll to the word CONFIGURATION. Press Select to make a selection of the CONFIGURATION.
Press the scroll button. Scroll to the RP/IOP config. Press select for the RP/IOP config.
4 You will see the RP SER and PNR.
5 Press the scroll button until you see APP, the number should be one of PN 996-4061-504/-505/-506/-507.
Press the scroll button until you see DB, the number should be PN 996-1232-547.
Select NEXT to get to the RP/MP Config.
Press the scroll button until you see APP, the number should be one of PN 996-4061-504/-505/-506/-507.
Press the scroll button until you see DB, the number should be PN 996-0175-502.
10 Press the scroll button until you see CFG, this number should be PN 996-4061-707.
11 Select NEXT to get to the TR.
12 Press the scroll button until you see APP, the number should be one of PN 996-4061-504/-505/-506/-507.
13 Select NEXT to get to the DA.
14 Press the scroll button until you see APP, the number should be one of PN 996-4061-504/-505/-506/-507.
(c) Replacement of Label 1 Remove the power from all of the equipment.
Replace part number label with PN 620-1974-154 for PN 930-1006-015.
23 Mar 2022 930-1006-34-0724013 Revision 1, 1 Nov 2022 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006
(2) Configuration File Load at a Service Center
(a) Configuration Assembly Load 1 Make sure no power is applied to the RP. Put the configuration feature software CF card, refer to Table 2 the CF card part number, in the vertical slot under the right port cover. The right port cover is on the 2 Apply power to the RP.
3 The transfer process can take up to 2 minutes. This can change when the amount of data to be uploaded changes. The data load is complete when the LCD shows the message "Upload Successful", "Upload Fail", or "Invalid Card". Any other text means that the transfer is still in work.
(b) Data Load Check NOTE: The instructions in this paragraph use the RP-1 front panel display to make sure the software part numbers are correct. Refer to Figure 1 for the location of the RP-1 front panel display.
1 Apply power to the RP-1.
Press the scroll button. Scroll to the word CONFIGURATION. Press Select to make a selection of the CONFIGURATION.
Press the scroll button. Scroll to the RP/IOP. Select the RP/OP.
Press the select button to see the IOP part numbers.
5 Scroll through the part numbers.
Scroll to the line that starts with APP.
Make sure the part number on this line is one of the SW PN 996-4061-504/-505/-506/-507.
Scroll to the line that starts with DB.
9 Make sure the part number on this line is PN 996-1232-547.
10 Select NEXT to get to the RP/MP.
11 Scroll to the line that starts with APP.
12 Make sure the part number on this line is one of the SW PN 996-4061-504/-505/-506/-507.
13 Scroll to the line that starts with DB.
14 Make sure the part number on this line is PN 996-0175-502.
15 Scroll to the line that starts with CFG, this number should be PN 996-4061-707.
NOTE: If the RP-1 does not have the correct part numbers as verified in this section, go to the applicable section and repeat the instructions to upload the correct software.
23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 14 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006
(c) Replacement of Label 1 Remove the power from all of the equipment.
Replace part number label with PN 620-1974-154 for PN 930-1006-015.
C. Test
(1) Do a test of the RP-1. Refer to the instructions in the TESTING AND FAULT ISOLATION section of the CMM 34-41-68.
23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 15 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006
4. Appendix A. Appendix A, Acronyms and Abbreviations
(1) Refer to Table 4 for a list of the acronyms and abbreviations used in this service bulletin.
Table 4. Acronyms and Abbreviations Term Full Term ATA Air Transport Association CAGE Commercial and Government Entity CF Compact Flash CFG Configuration CFR Code of Federal Regulations CMM Component Maintenance Manual DA Drive Assembly ECCN Export Control Classification Number FAA Federal Aviation Administration HCS Hazard Communication Standard NID Identification Inc. Incorporated IPL Illustrated Parts List LCD Liquid Crystal Display LRU Line Replaceable Unit MOD Modification OEM Original Equipment Manufacturer OSHA Occupational Safety and Health Administration PMA Parts Manufacturer Approval PN Part Number PNR Part Number Qty Quantity RP Radar Processor RTCA Radio Technical Commission for Aeronautics SER Serial SW Software TR Transmitter Receiver TSO Technical Standard Order 23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 16 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.
Honeywell
SERVICE BULLETIN 930-1006 Appendix B, Customer Support Service Report
(1) If the modification given in this service bulletin is done at a location other than a Honeywell service center, complete the CSSR.
LRU/SRU Model/Nomenclature: RP-1 radar processor * LRU/SRU Part No.
(Before modification):
* LRU/SRU Part No.
(After modification):
* LRU/SRU Serial Number:
* Hardware/Software MOD Level (Before modification):
* Hardware/Software MOD Level (After modification):
Aircraft Type, Serial Number, Tail Number:
* End User Company Name:
Company Address:
* Service Provider Person to Contact:
Company Name:
Company Address:
Company Phone No.:
Date of modification:
* Required Information Fields Honeywell Internal Use Only SAR Number.: QDS Customer Number.:
Honeywell Mail or Fax Aerospace Electronic Systems Attn: Order Management Completed Form to:
P.O. Box 21111 Phoenix, AZ 85036-1111 FAX: 1-602-822-7272 23 Mar 2022 930-1006-34-0240 Revision 1, 1 Nov 2022 Page 17 Publication Number D202202002219 © Honeywell International Inc. Do not copy without express permission of Honeywell.