AC 120-39

Historical

Advisory circular · Hazards of Waste Water Ice Accumulation Separating from Aircraft in Flight

Approved
October 31, 1980
Last reviewed
October 25, 2024
This change
Canceled by Memo signed by Wesley L. Mooty for Lawrence Fields and Jacqueline A. Tonic for Derek M. Honda; dated 12/21/2023.
Family
AC 120-39 · 1 version
14 CFR parts
1

Guidance, not mandatory unless a rule or AD requires it. DRS record last changed November 22, 2025.

AC 120-39 DATE lO/31/80

ADVISORY CIRCULAR DEPAItTMENT OF TRANSPOI~TATION Federal Aviation Administration Washington, D.C.

Sz4 bject: HAZARDS OF WASTE WATER ICE ACCUMULATION SEPARATING FROM AIRCRAFT

IN FLIGHT 1 PURPOSE. This advisory circular is issued to emphasize the potential ha.zards to life and property due to lavatory fluid and potable water systems' ice accumulation and resultant separation from aircraft in flight.

2 BACKGROUND. Lavatory fluid and potable water systems' ice accumulation in flight may drop off of the aircraft, posing a hazard to ground persoi?nek%nd' ground property, and may damage the aircraft wing, empennage or engine.

Accordingly, this advisory circular is being issued to emphasize the need for proper maintenance of aircraft drainage systems.

a. Lavatory waste water drain system. The aircraft provide a means of collecting and holding the lavatory waste water until it is disposed of by ground personnel. These holding tanks incorporate pumps, filters, screens, drain valves and their associated equipment. Fach tank is serviced with approximately 2 l/2 gallons of water with a blue chemical deodorizer and disinfectant. This water is the initial flushing fluid used for the lavatories. To prevent leakage during flight, a primary seal is provided by incorporating "0" rings, rubber valve seats or gaskets in a manual valve that can only be operated on the ground. To back up-this valve should it leak, a secondary method of preventing leakage is by the use of a cap with an "0" ring to seal the drain port. Failure to provide an adequate maintenance programfor the drain valve and duct cap may cause "blue" ice to develop on the underside of the fuselage and subsequently to drop off as the aircraft descends into warm air.

b Potable waste water drainage system. Some aircraft drain the waste water&o the lavatory holding tanks,and other aircraft drain waste water overboard through drain masts. These drain masts are anti-iced by cabin warm air from the lavatory vents and/or by electrical heating elements. Proper Initiated by: AWS-330

AC 120-39 10/31/80 operation and maintenance of the drain masts should prevent ice accumulation.

CAULTON: Co NOT check the operational status of these heaters by the use of the hand, %-ZE heaters in the masts my reach temperatures of 175" F or higher.

3. RECOMMENDED ACTION. Each operator should initiate and accomplishl inspections and matenance of waste drain valves, caps, and heater systems to the extent necessary to ensure that these systems remain airwxthy and function as designed, to prevent ice build-up from leaking Mste water, and the resultant separation from the aircraft.

12M. C. Bear Director of Airworthiness bI _ r, Par 2