AC 25-17A

Advisory circular · Transport Airplane Cabin Interiors Crashworthiness Handbook

Show pages 618–629
Page 630Open in PDF

614 Refer to AC 21-34, “Shoulder Harness-Safety Belt Installations” dated 9/7/83 for additional information.

823. AMENDMENT 25-51, Effective March 8, 1980.

a. Regulation.

(a) If there are means to indicate to the passengers when safety belts should be fastened. They must be installed to be operated from either pilot seat.

(b) The rated strength of safety belts may not be less than that required to withstand the ultimate load factors specified in § 25.561, considering the dimensional characteristics of the belt installation for the specific seat or berth arrangement.

(c) Each belt [and shoulder harness] must be attached so that no part of the anchorage can fail at a load lower than that which would result from the application of ultimate load factors equal to those specified in § 25.561, multiplied by a factor of

1.33. This factor must be used in stead of the fitting factor prescribed in § 25.625.

The forward load factor need not be applied to safety belts for berths.

(d) Each safety belt must be equipped with a metal to metal latching device.

b. Guidance. There is no additional guidance for this amendment. However, §§ 91.200 and 121.311(e) require that transport category airplanes are equipped with shoulder harnesses at each crewmember seat and flight attendant seat after March 6, 1980. (Refer to paragraphs 81b and 85b for related guidance.) (Amendment 25-51) Refer to AC 21-34, “Shoulder Harness-Safety Belt Installations” dated 9/7/83 for additional information.

824. AMENDMENT 25-72, Effective July 20, 1990.

The Section 25.1413 was relocated to Section 25.785 (i) at Amendment 25-72.

825 - 840. [RESERVED]

Page 631Open in PDF

615 SECTION 25.1415 DITCHING EQUIPMENT

841. REGULATION IN EFFECT AT ADOPTION OF PART 25.

a. Regulation.

(a) Ditching equipment used in airplanes to be certificated for ditching under § 25.801, and operated under the operating rules of this chapter, must meet the requirements of this section.

(b) Each life raft and each life preserver must be approved. In addition-

(l) Unless excess rafts of enough capacity are provided, the buoyancy and seating capacity beyond the rated capacity of the rafts must accommodate all occupants of the airplane in the event of a loss of one raft of the largest rated capacity; and

(2) Each raft must have a trailing line, and must have a static line designed to hold the raft near the airplane but to release it if the airplane becomes totally submerged.

(c) Approved survival equipment must be attached to each life raft.

(d) There must be an approved long-range signaling device for use in one life raft.

(e) For airplanes not certificated for ditching under § 25.801 and not having approved life preservers, there must be an approved flotation means for each occupant. This means must be within easy reach of each seated occupant and must be readily removable from the airplane.

b. Guidance.

(1) Paragraph (b). If a TSO-C70 liferaft is used, in order to be considered approved for use on transport category airplanes, the liferaft must be approved as a Type I liferaft per TSO- C70 (or later revision) or equivalent. (Amendment 25-0)

(2) Paragraph (b)(1). The determination of life raft requirements in this regard is based on the desired occupancy (crew and passengers), and the normal and overload ratings of the rafts. For a given desired occupancy, all occupants must be accommodated in the rafts without exceeding the normal capacity ratings of all the rafts combined. In addition, for that same desired occupancy, the loss of the largest rated raft is assumed. In that event, the same occupancy must be accommodated in the remaining rafts without exceeding the overload capacity ratings of all the remaining rafts combined. Therefore, the minimum number of life rafts is two since an airplane with only one life raft can not comply with this requirement.

(Amendment 25-0)

(3) Paragraph (b)(2). The trailing line is for tying rafts together. The following are quoted from the applicable TSOs. The trailing line is referred to as the heaving-trailing line.

(Amendment 25-0)

Page 632Open in PDF

(i) TSO-C12c. Paragraph 4.2.3 “HEAVING-TRAILING LINE.” At least one floating heaving trailing line not less than 75 feet in length and with a tensile strength of not less than 250 lbs containing a floatable device of suitable size and weight, shall be located on the main flotation tube(s) near the sea anchor attachment and shall be accessible from either side of the raft. (Amendment 25-0) (A) NOTE: This line is considered as being the trailing line required by CAR 4b.645(a) (Section 25.1415(b)(2) of the CFR).

(ii) TSO-C69a. Paragraph 4.9 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length and at least 250 lbs strength must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the slide/raft. (Amendment 25-0)

(iii) TSO-C70a. Paragraph 5.4 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length for Type I rafts and not less than 35 feet in length for Type II rafts, and at least 250 lbs strength, must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the raft. A heaving-trailing line must be accessible in any inflated position of a reversible life raft. (Amendment 25-0)

(4) Paragraph (b)(2). The static line is for keeping the life raft or slide/raft near the airplane for boarding after the unit is launched or disconnected from the girt. The following are quoted from the applicable TSOs. The static line is referred to as the mooring line. (Amendment 25-0)

(i) TSO-C12c. Paragraph 4.2.1 “RAFT MOORING LINE.” A suitable mooring line with a wet breaking strength of 450-550 lbs and with a minimum length of 20 feet shall be provided. One end shall be attached to the raft at the point of intersection of the tubes on the outer periphery of the raft with the rest of the line held flaked to the carrying case (Refer to 4.2.8 below). The strength of the attachment of the raft shall be in excess of the strength of the line.

(Amendment 25-0) (A) NOTE: This line is considered as being the static line required by CAR 4b.645(a) (Section 25.1415(b)(2) of the CFR).

(ii) TSO-C69a. Paragraph 4.10 “MOORING LINE.” A nonrotting mooring line at least 20 feet in length must be attached at one end to the slide/raft. The mooring line must be capable of keeping the slide/raft, loaded to maximum rated capacity, attached to a floating aircraft, and not endanger the slide/raft or cause the slide/raft to spill occupants if the aircraft sinks. The line may be equipped with a mechanical release linkage. The breaking strength of the line must be at least 500 lbs, or 40 times the rated capacity of the slide/raft, whichever is greater, but need not exceed 1,000 lbs. (Amendment 25-0)

Page 633Open in PDF

(iii) TSO-C70a. Paragraph 5.10 “MOORING LINE.” A nonrotting mooring line at least 20 feet in length must be attached at one end to one end of the raft, with the remainder of the line held flaked to the carrying case (Refer to 5.2). The mooring line must be capable of keeping the raft, loaded to maximum rated capacity, attached to a floating aircraft, and not endanger the raft or cause the raft to spill occupants if the aircraft sinks. The line may be equipped with a mechanical release linkage. The breaking strength of the line must be at least 500 lbs, or 40 times the rated capacity of the raft, whichever is greater, but need not exceed 1,000 lbs. (Amendment 25-0)

842. AMENDMENT 25-29, Effective October 21, 1971.

a. Regulation.

(a) Ditching equipment used in airplanes to be certificated for ditching under § 25.801, and operated under the operating rules of this chapter, must meet the requirements of this section.

(b) Each liferaft and each life preserver must be approved. In addition-

(1) Unless excess rafts of enough capacity are provided, the buoyancy and seating capacity beyond the rated capacity of the rafts must accommodate all occupants of the airplane in the event of a loss of one raft of the largest rated capacity; and

(2) Each raft must have a trailing line, and must have a static line designed to hold the raft near the airplane but to release it if the airplane becomes totally submerged.

(c) Approved survival equipment must be attached to each liferaft.

[(d) There must be a survival type emergency locator transmitter that meets the applicable requirements of § 37.200 of this chapter for use in one life raft.]

(e) For airplanes not certificated for ditching under § 25.801 and not having approved life preservers, there must be an approved flotation means for each occupant. This means must be within easy reach of each seated occupant and must be readily removable from the airplane.

b. Guidance.

(1) Paragraph (b). If a TSO-C70 liferaft is used, in order to be considered approved for use on transport category airplanes, the liferaft must be approved as a Type I liferaft per TSO- C70 (or later revision) or equivalent. (Amendment 25-0)

(2) Paragraph (b)(1). The determination of life raft requirements in this regard is based on the desired occupancy (crew and passengers), and the normal and overload ratings of the rafts. For a given desired occupancy, all occupants must be accommodated in the rafts without

Page 634Open in PDF

618 exceeding the normal capacity ratings of all the rafts combined. In addition, for that same desired occupancy, the loss of the largest rated raft is assumed. In that event, the same occupancy must be accommodated in the remaining rafts without exceeding the overload capacity ratings of all the remaining rafts combined. Therefore, the minimum number of life rafts is two since an airplane with only one life raft can not comply with this requirement.

(Amendment 25-0)

(3) Paragraph (b)(2). The trailing line is for tying rafts together. The following are quoted from the applicable TSOs. The trailing line is referred to as the heaving-trailing line.

(Amendment 25-0)

(i) TSO-C12c. Paragraph 4.2.3 “HEAVING-TRAILING LINE.” At least one floating heaving trailing line not less than 75 feet in length and with a tensile strength of not less than 250 lbs containing a floatable device of suitable size and weight, shall be located on the main flotation tube(s) near the sea anchor attachment and shall be accessible from either side of the raft. (Amendment 25-0) (A) NOTE: This line is considered as being the trailing line required by CAR 4b.645(a) (Section 25.1415(b)(2) of the CFR).

(ii) TSO-C69a. Paragraph 4.9 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length and at least 250 lbs strength must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the slide/raft. (Amendment 25-0)

(iii) TSO-C70a. Paragraph 5.4 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length for Type I rafts and not less than 35 feet in length for Type II rafts, and at least 250 lbs strength, must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the raft. A heaving-trailing line must be accessible in any inflated position of a reversible life raft. (Amendment 25-0)

(4) Paragraph (b)(2). The static line is for keeping the life raft or slide/raft near the airplane for boarding after the unit is launched or disconnected from the girt. The following are quoted from the applicable TSOs. The static line is referred to as the mooring line. (Amendment 25-0)

(i) TSO-C12c. Paragraph 4.2.1 “RAFT MOORING LINE.” A suitable mooring line with a wet breaking strength of 450-550 lbs and with a minimum length of 20 feet shall be provided. One end shall be attached to the raft at the point of intersection of the tubes on the

Page 635Open in PDF

619 outer periphery of the raft with the rest of the line held flaked to the carrying case (Refer to 4.2.8 below). The strength of the attachment of the raft shall be in excess of the strength of the line.

(Amendment 25-0) (A) NOTE: This line is considered as being the static line required by CAR 4b.645(a) (Section 25.1415(b)(2) of the CFR).

(ii) TSO-C69a. Paragraph 4.10 “MOORING LINE.” A nonrotting mooring line at least 20 feet in length must be attached at one end to the slide/raft. The mooring line must be capable of keeping the slide/raft, loaded to maximum rated capacity, attached to a floating aircraft, and not endanger the slide/raft or cause the slide/raft to spill occupants if the aircraft sinks. The line may be equipped with a mechanical release linkage. The breaking strength of the line must be at least 500 lbs, or 40 times the rated capacity of the slide/raft, whichever is greater, but need not exceed 1,000 lbs. (Amendment 25-0)

(iii) TSO-C70a. Paragraph 5.10 “MOORING LINE.” A nonrotting mooring line at least 20 feet in length must be attached at one end to one end of the raft, with the remainder of the line held flaked to the carrying case (Refer to 5.2). The mooring line must be capable of keeping the raft, loaded to maximum rated capacity, attached to a floating aircraft, and not endanger the raft or cause the raft to spill occupants if the aircraft sinks. The line may be equipped with a mechanical release linkage. The breaking strength of the line must be at least 500 lbs, or 40 times the rated capacity of the raft, whichever is greater, but need not exceed 1,000 lbs. (Amendment 25-0)

(5) Paragraph (d). Part 37 has been eliminated, therefore the standard the emergency locator transmitter (ELT) shall meet is TSO-C91. (Amendment 25-29)

843. AMENDMENT 25-52, Effective September 9, 1980.

a. Regulation.

(a) Ditching equipment used in airplanes to be certificated for ditching under § 25.801, and operated under the operating rules of this chapter, must meet the requirements of this section.

(b) Each liferaft and each life preserver must be approved. In addition-

(1) Unless excess rafts of enough capacity are provided, the buoyancy and seating capacity beyond the rated capacity of the rafts must accommodate all occupants of the airplane in the event of a loss of one raft of the largest rated capacity; and

(2) Each raft must have a trailing line, and must have a static line designed to hold the raft near the airplane but to release it if the airplane becomes totally submerged.

(c) Approved survival equipment must be attached to each liferaft.

Page 636Open in PDF

(d) There must be a survival type emergency locator transmitter that meets the applicable requirements of [TSO-C91] for use in one life raft.

(e) For airplanes not certificated for ditching under § 25.801 and not having approved life preservers, there must be an approved flotation means for each occupant. This means must be within easy reach of each seated occupant and must be readily removable from the airplane.

b. Guidance.

(1) Paragraph (b). If a TSO-C70 liferaft is used, in order to be considered approved for use on transport category airplanes, the liferaft must be approved as a Type I liferaft per TSO- C70 (or later revision) or equivalent. (Amendment 25-0)

(2) Paragraph (b)(1). The determination of life raft requirements in this regard is based on the desired occupancy (crew and passengers), and the normal and overload ratings of the rafts. For a given desired occupancy, all occupants must be accommodated in the rafts without exceeding the normal capacity ratings of all the rafts combined. In addition, for that same desired occupancy, the loss of the largest rated raft is assumed. In that event, the same occupancy must be accommodated in the remaining rafts without exceeding the overload capacity ratings of all the remaining rafts combined. Therefore, the minimum number of life rafts is two since an airplane with only one life raft can not comply with this requirement.

(Amendment 25-0)

(3) Paragraph (b)(2). The trailing line is for tying rafts together. The following are quoted from the applicable TSOs. The trailing line is referred to as the heaving-trailing line.

(Amendment 25-0)

(i) TSO-C12c. Paragraph 4.2.3 “HEAVING-TRAILING LINE.” At least one floating heaving trailing line not less than 75 feet in length and with a tensile strength of not less than 250 lbs containing a floatable device of suitable size and weight, shall be located on the main flotation tube(s) near the sea anchor attachment and shall be accessible from either side of the raft. (Amendment 25-0) (A) NOTE: This line is considered as being the trailing line required by CAR 4b.645(a) (Section 25.1415(b)(2) of the CFR).

(ii) TSO-C69a. Paragraph 4.9 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length and at least 250 lbs strength must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the slide/raft. (Amendment 25-0)

(iii) TSO-C70a. Paragraph 5.4 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length for Type I rafts and not less than 35

Page 637Open in PDF

621 feet in length for Type II rafts, and at least 250 lbs strength, must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the raft. A heaving-trailing line must be accessible in any inflated position of a reversible life raft. (Amendment 25-0)

(4) Paragraph (b)(2). The static line is for keeping the life raft or slide/raft near the airplane for boarding after the unit is launched or disconnected from the girt. The following are quoted from the applicable TSOs. The static line is referred to as the mooring line. (Amendment 25-0)

(i) TSO-C12c. Paragraph 4.2.1 “RAFT MOORING LINE.” A suitable mooring line with a wet breaking strength of 450-550 lbs and with a minimum length of 20 feet shall be provided. One end shall be attached to the raft at the point of intersection of the tubes on the outer periphery of the raft with the rest of the line held flaked to the carrying case (Refer to 4.2.8 below). The strength of the attachment of the raft shall be in excess of the strength of the line.

(Amendment 25-0) (A) NOTE: This line is considered as being the static line required by CAR 4b.645(a) (Section 25.1415(b)(2) of the CFR).

(ii) TSO-C69a. Paragraph 4.10 “MOORING LINE.” A nonrotting mooring line at least 20 feet in length must be attached at one end to the slide/raft. The mooring line must be capable of keeping the slide/raft, loaded to maximum rated capacity, attached to a floating aircraft, and not endanger the slide/raft or cause the slide/raft to spill occupants if the aircraft sinks. The line may be equipped with a mechanical release linkage. The breaking strength of the line must be at least 500 lbs, or 40 times the rated capacity of the slide/raft, whichever is greater, but need not exceed 1,000 lbs. (Amendment 25-0)

(iii) TSO-C70a. Paragraph 5.10 “MOORING LINE.” A nonrotting mooring line at least 20 feet in length must be attached at one end to one end of the raft, with the remainder of the line held flaked to the carrying case (Refer to 5.2). The mooring line must be capable of keeping the raft, loaded to maximum rated capacity, attached to a floating aircraft, and not endanger the raft or cause the raft to spill occupants if the aircraft sinks. The line may be equipped with a mechanical release linkage. The breaking strength of the line must be at least 500 lbs, or 40 times the rated capacity of the raft, whichever is greater, but need not exceed 1,000 lbs. (Amendment 25-0)

(5) Paragraph (c). Refer to AC 120-47, “Survival Equipment for Use in Overwater Operations,” dated 6/12/87. (Amendment 25-52)

(6) Paragraph (d). Note: an equivalent level of safety finding is required to use TSO- C91a equipment in lieu of TSO-C91 equipment to meet this regulation. (Amendment 25-52)

Page 638Open in PDF

844. AMENDMENT 25-72, Effective August 20, 1990.

a. Regulation.

[(a) Ditching equipment used in airplanes to be certificated for ditching under § 25.801, and required by the operating rules of this chapter, must meet the requirements of this section.]

(b) Each liferaft and each life preserver must be approved. In addition-

(1) Unless excess rafts of enough capacity are provided, the buoyancy and seating capacity beyond the rated capacity of the rafts must accommodate all occupants of the airplane in the event of a loss of one raft of the largest rated capacity; and

(2) Each raft must have a trailing line, and must have a static line designed to hold the raft near the airplane but to release it if the airplane becomes totally submerged.

(c) Approved survival equipment must be attached to each liferaft.

(d) There must be a survival type emergency locator transmitter that meets the applicable requirements of TSO-C91 for use in one life raft.

(e) For airplanes not certificated for ditching under § 25.801 and not having approved life preservers, there must be an approved flotation means for each occupant. This means must be within easy reach of each seated occupant and must be readily removable from the airplane.

b. Guidance.

(1) Paragraph (b). If a TSO-C70 liferaft is used, in order to be considered approved for use on transport category airplanes, the liferaft must be approved as a Type I liferaft per TSO- C70 (or later revision) or equivalent. (Amendment 25-0)

(2) Paragraph (b)(1). The determination of life raft requirements in this regard is based on the desired occupancy (crew and passengers), and the normal and overload ratings of the rafts. For a given desired occupancy, all occupants must be accommodated in the rafts without exceeding the normal capacity ratings of all the rafts combined. In addition, for that same desired occupancy, the loss of the largest rated raft is assumed. In that event, the same occupancy must be accommodated in the remaining rafts without exceeding the overload capacity ratings of all the remaining rafts combined. Therefore, the minimum number of life rafts is two since an airplane with only one life raft can not comply with this requirement.

(3) In order to be considered approved for use on transport category airplanes, the liferaft must be approved as a Type I liferaft per TSO-C70 (current version) or equivalent.

(Amendment 25-0)

Page 639Open in PDF

(4) Paragraph (b)(2). The trailing line is for tying rafts together. The following are quoted from the applicable TSOs. The trailing line is referred to as the heaving-trailing line.

(Amendment 25-0)

(i) TSO-C12c. Paragraph 4.2.3 “HEAVING-TRAILING LINE.” At least one floating heaving trailing line not less than 75 feet in length and with a tensile strength of not less than 250 lbs containing a floatable device of suitable size and weight, shall be located on the main flotation tube(s) near the sea anchor attachment and shall be accessible from either side of the raft. (Amendment 25-0) (A) NOTE: This line is considered as being the trailing line required by CAR 4b.645(a) (Section 25.1415(b)(2) of the CFR).

(ii) TSO-C69a. Paragraph 4.9 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length and at least 250 lbs strength must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the slide/raft. (Amendment 25-0)

(iii) TSO-C70a. Paragraph 5.4 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length for Type I rafts and not less than 35 feet in length for Type II rafts, and at least 250 lbs strength, must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the raft. A heaving-trailing line must be accessible in any inflated position of a reversible life raft. (Amendment 25-0)

(5) Paragraph (b)(2). The static line is for keeping the life raft or slide/raft near the airplane for boarding after the unit is launched or disconnected from the girt. The following are quoted from the applicable TSOs. The static line is referred to as the mooring line. (Amendment 25-0)

(i) TSO-C12c. Paragraph 4.2.1 “RAFT MOORING LINE.” A suitable mooring line with a wet breaking strength of 450-550 lbs and with a minimum length of 20 feet shall be provided. One end shall be attached to the raft at the point of intersection of the tubes on the outer periphery of the raft with the rest of the line held flaked to the carrying case (Refer to 4.2.8 below). The strength of the attachment of the raft shall be in excess of the strength of the line.

(Amendment 25-0) (A) NOTE: This line is considered as being the static line required by CAR 4b.645(a) (Section 25.1415(b)(2) of the CFR).

(ii) TSO-C69a. Paragraph 4.10 “MOORING LINE.” A nonrotting mooring line at least 20 feet in length must be attached at one end to the slide/raft. The mooring line must be capable of keeping the slide/raft, loaded to maximum rated capacity, attached to a floating aircraft, and not endanger the slide/raft or cause the slide/raft to spill occupants if the aircraft sinks. The line may be equipped with a mechanical release linkage. The breaking strength of

Page 640Open in PDF

624 the line must be at least 500 lbs, or 40 times the rated capacity of the slide/raft, whichever is greater, but need not exceed 1,000 lbs. (Amendment 25-0)

(iii) TSO-C70a. Paragraph 5.10 “MOORING LINE.” A nonrotting mooring line at least 20 feet in length must be attached at one end to one end of the raft, with the remainder of the line held flaked to the carrying case (Refer to 5.2). The mooring line must be capable of keeping the raft, loaded to maximum rated capacity, attached to a floating aircraft, and not endanger the raft or cause the raft to spill occupants if the aircraft sinks. The line may be equipped with a mechanical release linkage. The breaking strength of the line must be at least 500 lbs, or 40 times the rated capacity of the raft, whichever is greater, but need not exceed 1,000 lbs. (Amendment 25-0)

(6) Paragraph (c). Refer to AC 120-47, “Survival Equipment for Use in Overwater Operations,” dated 6/12/87. (Amendment 25-52)

(7) Paragraph (d). Note: an equivalent level of safety finding is required to use TSO- C91a equipment in lieu of TSO-C91 equipment to meet this regulation. (Amendment 25-52)

845. AMENDMENT 25-82, Effective June 21, 1994.

a. Regulation.

(a) Ditching equipment used in airplanes to be certificated for ditching under § 25.801, and required by the operating rules of this chapter, must meet the requirements of this section.

(b) Each life raft and each life preserver must be approved. In addition-

(1) Unless excess rafts of enough capacity are provided, the buoyancy and seating capacity beyond the rated capacity of the rafts must accommodate all occupants of the airplane in the event of a loss of one raft of the largest rated capacity; and

(2) Each raft must have a trailing line, and must have a static line designed to hold the raft near the airplane but to release it if the airplane becomes totally submerged.

(c) Approved survival equipment must be attached to each life raft.

[(d) There must be an approved survival type emergency locator transmitter for use in one life raft.]

(e) For airplanes not certificated for ditching under § 25.801 and not having approved life preservers, there must be an approved flotation means for each occupant. This means must be within easy reach of each seated occupant and must be readily removable from the airplane.

Page 641Open in PDF

b. Guidance.

(1) Paragraph (b). If a TSO-C70 liferaft is used, in order to be considered approved for use on transport category airplanes, the liferaft must be approved as a Type I liferaft per TSO- C70 (or later revision) or equivalent. (Amendment 25-0)

(2) Paragraph (b)(1). The determination of life raft requirements in this regard is based on the desired occupancy (crew and passengers), and the normal and overload ratings of the rafts. For a given desired occupancy, all occupants must be accommodated in the rafts without exceeding the normal capacity ratings of all the rafts combined. In addition, for that same desired occupancy, the loss of the largest rated raft is assumed. In that event, the same occupancy must be accommodated in the remaining rafts without exceeding the overload capacity ratings of all the remaining rafts combined. Therefore, the minimum number of life rafts is two since an airplane with only one life raft can not comply with this requirement.

(Amendment 25-0)

(3) Paragraph (b)(2). The trailing line is for tying rafts together. The following are quoted from the applicable TSOs. The trailing line is referred to as the heaving-trailing line.

(Amendment 25-0)

(i) TSO-C12c. Paragraph 4.2.3 “HEAVING-TRAILING LINE.” At least one floating heaving trailing line not less than 75 feet in length and with a tensile strength of not less than 250 lbs containing a floatable device of suitable size and weight, shall be located on the main flotation tube(s) near the sea anchor attachment and shall be accessible from either side of the raft. (Amendment 25-0) (A) NOTE: This line is considered as being the trailing line required by CAR 4b.645(a) (Section 25.1415(b)(2) of the CFR).

(ii) TSO-C69a. Paragraph 4.9 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length and at least 250 lbs strength must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the slide/raft. (Amendment 25-0)

(iii) TSO-C70a. Paragraph 5.4 “HEAVING-TRAILING LINE.” At least one floating heaving-trailing line not less than 75 feet in length for Type I rafts and not less than 35 feet in length for Type II rafts, and at least 250 lbs strength, must be located on the main flotation tube near the sea anchor attachment. The attach point of the line must withstand a pull of not less than 1.5 times the line rated strength without damage to the raft. A heaving-trailing line must be accessible in any inflated position of a reversible life raft. (Amendment 25-0)

(4) Paragraph (b)(2). The static line is for keeping the life raft or slide/raft near the airplane for boarding after the unit is launched or disconnected from the girt. The following are quoted from the applicable TSOs. The static line is referred to as the mooring line. (Amendment 25-0)